首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A method for adapting widely used CE conditions for the separation of fluorescently labeled carbohydrates to permit online ESI‐MS detection is presented. Reverse polarity separations were performed in bare fused‐silica capillaries with an acidic BGE. Under these conditions, negatively charged 8‐aminopyrene 1,3,6‐trisulfonate‐labeled carbohydrates migrate forward against the EOF, which is towards the capillary inlet. Therefore, the CE‐MS interface must simultaneously back‐fill the capillary, in order to maintain the CE circuit, and provide a stable forward flow at the sprayer tip to support the electrospray process. This was achieved using a junction‐at‐the‐tip interface, which provides a flow of solution to the junction formed by the capillary terminus and the inner wall of the emitter needle tip. Because the flow rate required for this arrangement is much less than in conventional sheath flow interfaces, dilution of the analytes is minimized. Optimized separation conditions permit baseline resolution of glucose oligomers containing up to 15 glucose units, while longer oligomers, up to 33 glucose units, were observed as resolved peaks in the negative ion mode mass spectrum.  相似文献   

2.
Electrospray ionization performs best with volatile buffers. However, generally the best separation performance for capillary electrophoresis (CE) is achieved with non‐volatile buffers. Hyphenation of CE with mass spectrometry (MS) utilizing atmospheric pressure photoionization (APPI) enables use of a wider range of separation buffers without compromising detection sensitivity. As APPI is considered to be mass flow sensitive, the use of a larger inner diameter separation capillary (75 µm) allows larger volumes to be injected, without decreased separation performance, thus providing improved sensitivity (approx. a factor of 10), compared to the use of a 25 µm capillary. However, nebulizing gas flow and position of capillary tip in the sprayer have to be carefully optimized to prevent excessive band broadening. Further improvement in sensitivity (approx. a factor of 2) was obtained by decreasing the distance between the sprayer and ionization region, indicating that a specially designed CE/APPI‐MS interface for low flow rates will be favourable. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
建立了高效毛细管电泳-电喷雾飞行时间质谱联用(HPCE-ESI-TOF/MS)快速定性分析黄连中生物碱类化合物的分析方法. 使用未涂层石英毛细管, 以50 mmol/L乙酸铵-0.5%甲醇溶液(用氨水调至pH=7.2)作为运行缓冲液, 分离电压为25 kV; 鞘液组成为50%甲醇-49.5%水-0.5%乙酸, 鞘液流速为4 μL/min; 质谱选用正离子模式, 碰撞电压(Fragmentor)为100 V. 结果表明, 通过各色谱峰紫外光谱和质谱测得精确分子量结果, 结合文献, 对黄连中7种生物碱进行了鉴定. 表明本方法简便、快速, 是黄连中生物碱类化合物快速分离、鉴别的有效方法.  相似文献   

4.
We introduce continuous‐flow field desorption (FD) for improved spectral quality, higher sample throughput, and simpler interface to sample handlers and chromatographic equipment. A recently developed commercial FD probe with integral fused‐silica capillary allows sample dosing in situ, without probe removal and reinsertion. A stable FD‐generated ion current can be sustained for longer than an hour by continuous deposition of analyte solution on the FD emitter heated and at high voltage. Continuous‐flow FD allows ensemble averaging of up to 100 Fourier transform ion cyclotron resonance (FT‐ICR) mass spectra, in contrast to the traditional emitter dosing technique. Continuous‐flow FD is amenable to interface with liquid chromatography (LC) and/or automated sample injectors. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

5.
We report a capillary isoelectric focusing system based on a sequential injection method for simplified chemical mobilization. This system was coupled to an ion trap mass spectrometer with an electrokinetically pumped nanoelectrospray interface. The nanoelectrospray emitter employed an acidic sheath electrolyte. To simplify focusing and mobilization, a plug of ammonium hydroxide was first injected into the capillary, followed by a section of mixed sample and ampholyte. During focusing, the NH3H2O section worked as catholyte. As focusing progressed, the NH3H2O section was titrated to lower pH by the acidic sheath electrolyte. Chemical mobilization started automatically once the ammonium hydroxide was consumed by the acidic sheath flow electrolyte, which then acted as the mobilization solution. In this report, the lengths of the NH3H2O section and sample were optimized. With a 1 m long capillary, a relative short plug of the NH3H2O section (3 cm) produced both fast migration and reasonable separation resolution. The simplified capillary isoelectric focusing mass spectrometry system produced base peak intensity relative standard deviation of 8.5% and migration time relative standard deviation ≤0.6% for myoglobin and cytochrome C in triplicate runs.  相似文献   

6.
Continuous flow infrared matrix‐assisted laser desorption electrospray ionization (CF IR MALDESI) mass spectrometry was demonstrated for the on‐line analysis of liquid samples. Samples in aqueous solution were flowed through a 50 µm i.d. fused‐silica capillary at a flow rate of 1–6 µL/min. As analyte aqueous solution flowed through the capillary, a liquid sample bead formed at the capillary tip. A pulsed infrared optical parametric oscillator (OPO) laser with wavelength of 2.94 µm and a 20 Hz repetition rate was focused onto the capillary tip for sample desorption and ablation. The plume of ejected sample was entrained in an electrospray to form ions by MALDESI. The resulting ions were sampled into an ion trap mass spectrometer for analysis. Using CF IR MALDESI, several chemical and biochemical reactions were monitored on‐line: the chelation of 1,10‐phenanthroline with iron(II), insulin denaturation with 1,4‐dithiothreitol, and tryptic digestion of cytochrome c. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
Chen YR  Tseng MC  Her GR 《Electrophoresis》2005,26(7-8):1376-1382
A low-flow electrophoresis-mass spectrometry (CE-MS) interface has been developed for interfacing capillary zone electrophoresis (CZE) with electrospray- ionization-mass spectrometry (ESI-MS). The interface consists of two parallel capillary columns (a separation column and a makeup column), and an emitter with a dual beveled edge. While maintaining a relatively low optimum flow rate, the dual-beveled-edge ESI emitter allows the use of a tip with larger orifice. Therefore, this interface is less prone to column blocking in comparison with a flat tip. Primarily attributed to low sample dilution and smaller initial droplet, the interface showed better sensitivity than a conventional sheath liquid interface. Furthermore, the interface was found to be more resistant to the presence of nonvolatile salts. By using 40 mM borate and 20 mM alpha-cyclodextrin (alpha-CD) as the running buffer, four major forms of gangliosides were detected by CE-MS.  相似文献   

8.
Tseng MC  Chen YR  Her GR 《Electrophoresis》2004,25(13):2084-2089
A simple and durable sheath liquid interface for capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) has been developed. This interface utilized a beveled tip emitter and was found to be more sensitive than the conventional sheath liquid interface. The use of a beveled tip reduces the optimal flow rate and therefore decreases sample dilution. The interface utilized a 380 microm inner diameter and 400 microm outer diameter beveled tapered tip. Because of the large inner diameter and outer diameter of the tip, the interface is robust and can be easily implemented. The performance of this interface for CZE-ESI-MS and micelle electrokinetic capillary electrophoresis-electrospray-mass spectrometry, as demonstrated by the analysis of synthetic drugs and triazine mixtures, was significantly better than results obtained using a conventional sheath liquid interface.  相似文献   

9.
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 microm, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate.  相似文献   

10.
The high‐sensitive detection of explosives is of great importance for social security and safety. In this work, the ion source for atmospheric pressure chemical ionization/mass spectrometry using alternating current corona discharge was newly designed for the analysis of explosives. An electromolded fine capillary with 115 µm inner diameter and 12 mm long was used for the inlet of the mass spectrometer. The flow rate of air through this capillary was 41 ml/min. Stable corona discharge could be maintained with the position of the discharge needle tip as close as 1 mm to the inlet capillary without causing the arc discharge. Explosives dissolved in 0.5 µl methanol were injected to the ion source. The limits of detection for five explosives with 50 pg or lower were achieved. In the ion/molecule reactions of trinitrotoluene (TNT), the discharge products of NOx? (x = 2,3), O3 and HNO3 originating from plasma‐excited air were suggested to contribute to the formation of [TNT ? H]? (m/z 226), [TNT ? NO]? (m/z 197) and [TNT ? NO + HNO3]? (m/z 260), respectively. Formation processes of these ions were traced by density functional theory calculations. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
Arrays of chemically etched emitters with individualized sheath gas capillaries were developed to enhance electrospray ionization (ESI) efficiency at subambient pressures. By incorporating the new emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, both ionization efficiency and ion transmission efficiency were significantly increased, providing enhanced sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses of conventional ESI-mass spectrometry (MS) interfaces by placing the emitter in the first reduced pressure region of the instrument. The new ESI emitter array design developed in this study allows individualized sheath gas around each emitter in the array making it possible to generate an array of uniform and stable electrosprays in the subambient pressure (10 to 30 Torr) environment for the first time. The utility of the new emitter arrays was demonstrated by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared under different ESI source and interface configurations including a standard atmospheric pressure single ESI emitter/heated capillary, single emitter/SPIN and multi-emitter/SPIN configurations using an equimolar solution of nine peptides. The highest instrument sensitivity was observed using the multi-emitter/SPIN configuration in which the sensitivity increased with the number of emitters in the array. Over an order of magnitude MS sensitivity improvement was achieved using multi-emitter/SPIN compared with using the standard atmospheric pressure single ESI emitter/heated capillary interface. Graphical Abstract
?  相似文献   

12.
CE hyphenated to ESI-MS (CE-ESI-MS) is a well-established technique to analyze charged analytes in complex samples. Although various interfaces for CE-MS coupling are commercially available, the development of alternatives which combine sensitivity, simplicity, and robustness remains a topic of research. In this work, a nanoflow sheath liquid CE-MS interface with two movable capillaries inside a glass emitter is described. The setup enables a separation mode and a conditioning mode to guide the separation capillary effluent either into the electrospray or to the waste, respectively. This enables to exclude parts of the analysis from MS detection and unwanted matrix components reaching the mass spectrometer, comparable to divert valves in LC-MS coupling. Also, this function improves the overall robustness of the system by reduction of particles blocking the emitter. Preconditioning with electrospray interfering substances and even the application of coating materials for every analysis is enabled, even while the separation capillary is built into the interface with running electrospray. The functionality is demonstrated by analyses of heavy matrix bioreactor samples. Overall, this innovation offers a more convenient installation of the interface, improved handling with an extended lifetime of the emitter tips and additional functions compared to previous approaches, while keeping the higher sensitivity of nanoflow CE-MS-coupling.  相似文献   

13.
An optimised capillary electrophoresis-electrospray mass spectrometric method is presented for the identification and determination of diazepam and its metabolites N'-desmethyldiazepam, oxazepam and temazepam. By investigating constituent parts of the capillary electrophoresis-electrospray mass spectrometric interface and optimising their function, a relatively fast and reproducible method is described for the identification and determination of selected 1,4-benzodiazepines. Optimisation of sheath and auxiliary gas flows, capillary tip tapering, capillary tip positioning, sheath liquid composition and flow rate and pressure application during the separation step have led to acceptable relative standard deviation (RSD) values for migration time and peak area, correlation coefficients and limits of detection. This has been achieved as a result of stabilising the electrospray current prior to analysis, a procedure that takes a matter of minutes when using the method described. Sequential product ion fragmentation (MS(n)) characterisation of 15 1,4-benzodiazepines is also presented and mechanisms for the observed fragmentation patterns proposed.  相似文献   

14.
The hyphenation of capillary electrophoresis with high-resolution mass spectrometry, such as Orbitrap MS, is of broad interest for the unambiguous and exceptionally sensitive identification of compounds. However, the coupling of these techniques requires a robust ionization interface that does not influence the stability of the separation voltage while coping with oxidation of the emitter tip at large ionization voltages. Herein, we present the design of a sheath-flow CE-ESI-MS interface which combines a robust and easy to operate set-up with high-resolution Orbitrap MS detection. The sheath liquid interface is equipped with a gold coated electrospray emitter which increases the stability and overall lifetime of the system. For the characterization of the interface, the spray stability and durability were investigated in dependence of the sheath-flow rate, electrospray voltage, and additional gold coating. The optimized conditions were applied to a separation of angiotensin II and neurotensin resulting in LODs of 2.4 and 3.5 ng/mL.  相似文献   

15.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

16.
Although being an atmospheric pressure ion source, electrospray ionization (ESI) has rarely been used directly for ambient imaging mass spectrometry because the sample has to be introduced as liquid solution through the capillary. Instead of capillary, probe electrospray ionization (PESI), which has been developed recently, uses a solid needle as the sampling probe, as well as the electrospray emitter, and has been applied not only for liquid solutions but also for the direct sampling on wet samples. Biological tissues are composed of cells that contain 70–90% water, and when the surface is probed by the needle tip, the biological fluid adhering to the needle can be electrosprayed directly or assisted by additional solvent added onto the needle surface. Here, we demonstrate ambient imaging mass spectrometry of mouse brain section using PESI, incorporated with an auxiliary heated capillary sprayer. The solvent vapor generated from the sprayer condensed on the needle tip, re‐dissolving the adhered sample, and at the same time, providing an indirect means for needle cleaning. The histological sections were prepared by fixation using paraformaldehyde, and the spatial analysis was automated by maintaining an equal sampling depth into the sample in addition to raster scan. Phospholipids and galactosylceramides were readily detected from the mouse brain section in the positive ion mode, and were mapped with 60 µm lateral resolution to form mass spectrometric images. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A simple, specific and sensitive LC‐MS/MS method was developed and validated for the determination of mesalazine in beagle dog plasma. The plasma samples were prepared by protein precipitation, then the separation of the analyte was achieved on a Waters Spherisorb C6 column (150 × 4.6 mm, 5 µm) with a mobile phase consisting of 0.2% formic acid in water–methanol (20:80, v/v). The flow rate was set at 1.0 mL/min with a split ratio of 3:2. Mass spectrometric detection was achieved by a triple‐quadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. Quantitation was performed using selected reaction monitoring of precursor–product ion transitions at m/z 154 → m/z 108 for mesalazine and m/z 285 → m/z 193 for diazepam (internal standard). The linear calibration curve of mesalazine was obtained over the concentration range 50–30,000 ng/mL. The matrix effect of mesalazine was within ±9.8%. The intra‐ and inter‐day precisions were <7.9% and the accuracy (relative error) was within ±3.5%. The validated method was successfully applied to investigate the pharmacokinetics of mesalazine in healthy beagle dogs after rectal administration of mesalazine suppository. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid and sensitive LC‐MS/MS method was developed for the determination of linarin in small‐volume rat plasma and tissue sample. Sample preparation was employed by the combination of protein precipitation (PPT) and liquid–liquid extraction (LLE) to allow measurement over a 5‐order‐of‐magnitude concentration range. Fast chromatographic separation was achieved on a Hypersil Gold column (100 × 2.1 mm i.d., 5 µm). Mass spectrometric detection was achieved using a triple‐quadrupole mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. Quantification was performed using selected reaction monitoring of precursor‐product ion transitions at m/z 593 → 285 for linarin and m/z 447 → 271 for baicalin (internal standard). The total run time was only 2.8 min per sample. The calibration curves were linear over the concentration range of 0.4–200 µg/mL for PPT and 0.001–1.0 µg/mL for LLE. A lower limit of quantification of 1.0 ng/mL was achieved using only 20 μL of plasma or tissue homogenate. The intra‐ and inter‐day precisions in all samples were ≤14.7%, while the accuracy was within ±5.2% of nominal values. The validated method has been successfully applied to pharmacokinetic and tissue distribution study of linarin. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A new electrospray source design is introduced by having an extractor electrode placed at 1 to 2 mm behind the emitter tip. The extractor was integrated into the sprayer body as a single device. An insulating tube was used to isolate the emitter from the extractor and to deliver the sheath gas for the electrospray. The electric field strength at the emitter was primarily determined by the relative position and the potential between the needle and the extractor; therefore, the spraying condition was insusceptible to the change of sprayer position or orientation with respect to the ion sampling inlet. Such design allowed the use of much lower operating voltage and facilitated the optimization of sprayer position by keeping the electric field parameter constant. Using an emitter capillary of 150 and 310 μm in inner and outer diameters, strong ion signal could still be acquired with 2‐kV emitter potential even if the distance between the emitter and ion inlet was extended to >70 mm. Charge reduction of protein ions using 2 extractor‐based electrosprays of opposite emitter polarities was also demonstrated.  相似文献   

20.
Recently, the vacuum electrospray droplet impact (V‐EDI) was developed as a cluster ion beam source in our laboratory. To attain the ion beam stability and compact design of the ion source, a silica nano‐capillary with 15 µm i.d. was used as the emitter of the beam. It was found that stable electrospray was generated from the capillary tip without the use of laser heating when aqueous solution of 20% ethanol was used. The m/z distribution of electrospray droplets was measured by pulsing the primary beam. By assuming that the charged droplets contain 50% of the excess charges defined by the Rayleigh limit equation, the average mass, and charge of the droplets generated by the present V‐EDI are estimated as 2.5 × 108 u and + 625 charges, respectively, i.e. [(H2O)14,000,000 + 625H]625+. By chopping the primary cluster beam, clusters composed of smaller m/z clusters (group 1: G1, [(H2O)46,000 + 36H]36+) and those of larger m/z clusters (group 2: G2, [(H2O)560,000 + 125H]125+) were generated. Surface analysis for polyimide (PI) film by X‐ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) was made using G1, G2, and non‐selected cluster beams. No selective etching was observed when G1, G2, and non‐selected beams were used. However, larger surface roughening was observed when smaller size cluster beams were used. This suggests that larger size clusters cure the surface damage caused by the smaller ones. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号