首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
In stable isotope ratio mass spectrometry (IRMS), the stable isotopic composition of samples is measured relative to the isotopic composition of a working gas. This measured isotopic composition must be converted and reported on the respective international stable isotope reference scale for the accurate interlaboratory comparison of results. This data conversion procedure, commonly called normalization, is the first set of calculations done by the users. In this paper, we present a discussion and mathematical formulation of several existing routinely used normalization procedures. These conversion procedures include: single-point anchoring (versus working gas and certified reference standard), modified single-point normalization, linear shift between the measured and the true isotopic composition of two certified reference standards, two-point and multi-point linear normalization methods. Mathematically, the modified single-point, two-point, and multi-point normalization methods are essentially the same. By utilizing laboratory analytical data, the accuracy of the various normalization methods (given by the difference between the true and the normalized isotopic composition) has been compared. Our computations suggest that single-point anchoring produces normalization errors that exceed the maximum total uncertainties (e.g. 0.1 per thousand for delta(13)C) often reported in the literature, and, therefore, that it must not be used for routinely anchoring stable isotope measurement results to the appropriate international scales. However, any normalization method using two or more certified reference standards produces a smaller normalization error provided that the isotopic composition of the standards brackets the isotopic composition of unknown samples.  相似文献   

2.
The uncertainties of stable isotope results depend not only on the technical aspects of measurements, but also on how raw data are normalized to one of the international isotope scales. The inconsistency in the normalization methods used and in the selection of standards may lead to substantial differences in the results obtained. Therefore, unification of the data processing protocols employed is highly desirable. The best performing methods are two-point or multipoint normalization methods based on linear regression. Linear regression is most robust when based on standards that cover the entire range of δ values typically observed in nature, regardless of the δ values of the samples analysed. The uncertainty can be reduced by 50 % if measurements of two different standards are performed four times, or measurements of four standards are performed twice, with each batch of samples. Chemical matrix matching between standards and samples seems to be critical for δ 18O of nitrate or δ 2H of hair samples (thermal conversion/elemental analyser), for example; however, it is not necessarily always critical for all types of samples and techniques (e.g. not for most δ 15N and δ 13C elemental analyser analyses). To ensure that all published data can be recalculated, if δ values of standards or the isotope scales are to be updated, the details of the normalization technique and the δ values of the standards used should always be clearly reported.  相似文献   

3.
Comparative equilibration has been proposed as a methodological approach for determining the hydrogen isotopic composition (δD) of non‐exchangeable hydrogen in complex organic materials, from feathers to blood and soils. This method depends on using homogenized standards that have been previously calibrated for their δD values of non‐exchangeable H, that are compositionally similar to unknown samples, and that span an appropriate isotopic range. Currently no certified organic reference materials with exchangeable H exist, and so isotope laboratories have been required to develop provisional internal calibration standards, such as the keratin standards currently used in animal migration studies. Unfortunately, the isotope ratios of some samples fall outside the range of keratin standards currently used for comparative equilibration. Here we tested a set of five homogenized keratin powders as well as feathers from Painted Buntings and Dark‐eyed Juncos to determine the effects of extrapolating comparative equilibration normalization equations outside the isotopic range of keratin standards. We found that (1) comparative equilibration gave precise results within the range of the calibration standards; (2) linear extrapolation of normalization equations produced accurate δD results to ~40‰ outside the range of the keratins standards used (?187 to ?108); and (3) for both homogenized keratin powders and heterogeneous unknown samples there was no difference in variance between samples within and outside the range of keratin standards. This suggested that comparative equilibration is a robust and practical method for determining the δD of complex organic matrices, although caution is required for samples that fall far outside the calibration range. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the δ values of these reference materials should bracket the isotopic range of samples with unknown δ values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW‐SLAP) and carbonates (NBS 19 and L‐SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA‐IRMS). At present only L‐glutamic acids USGS40 and USGS41 satisfy these requirements for δ13C and δ15N, with the limitation that L‐glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on‐line (i.e. continuous flow) hydrogen reductive gas chromatography‐isotope ratio mass‐spectrometry (GC‐IRMS), (ii) five nicotines for oxidative C, N gas chromatography‐combustion‐isotope ratio mass‐spectrometry (GC‐C‐IRMS, or GC‐IRMS), and (iii) also three acetanilide and three urea reference materials for on‐line oxidative EA‐IRMS for C and N. Isotopic off‐line calibration against international stable isotope measurement standards at Indiana University adhered to the ‘principle of identical treatment’. The new reference materials cover the following isotopic ranges: δ2Hnicotine ?162 to ?45‰, δ13Cnicotine ?30.05 to +7.72‰, δ15Nnicotine ?6.03 to +33.62‰; δ15Nacetanilide +1.18 to +40.57‰; δ13Curea ?34.13 to +11.71‰, δ15Nurea +0.26 to +40.61‰ (recommended δ values refer to calibration with NBS 19, L‐SVEC, IAEA‐N‐1, and IAEA‐N‐2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC‐IRMS that are available with different δ15N values. Comparative δ13C and δ15N on‐line EA‐IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA‐IRMS reference materials. Published in 2009 by John Wiley & Sons, Ltd.  相似文献   

5.
Amino sugars in soils have been used as markers of microbial necromass and to determine the relative contribution of bacterial and fungal residues to soil organic matter. However, little is known about the dynamics of amino sugars in soil. This is partly because of a lack of adequate techniques to determine ‘turnover rates’ of amino sugars in soil. We conducted an incubation experiment where 13C‐labeled organic substrates of different quality were added to a sandy soil. The objectives were to evaluate the applicability of compound‐specific stable isotope analysis via gas chromatography‐combustion‐isotope ratio mass spectrometry (GC‐C‐IRMS) for the determination of 13C amino sugars and to demonstrate amino sugar dynamics in soil. We found total analytical errors between 0.8 and 2.6‰ for the δ13C‐values of the soil amino sugars as a result of the required δ13C‐corrections for isotopic alterations due to derivatization, isotopic fractionation and analytical conditions. Furthermore, the δ13C‐values of internal standards in samples determined via GC‐C‐IRMS deviated considerably from the δ13C‐values of the pure compounds determined via elemental analyzer IRMS (with a variation of 9 to 10‰ between the first and third quartile among all samples). This questions the applicability of GC‐C‐IRMS for soil amino sugar analysis. Liquid chromatography‐combustion‐IRMS (LC‐C‐IRMS) might be a promising alternative since derivatization, one of the main sources of error when using GC‐C‐IRMS, is eliminated from the procedure. The high 13C‐enrichment of the substrate allowed for the detection of very high 13C‐labels in soil amino sugars after 1 week of incubation, while no significant differences in amino sugar concentrations over time and across treatments were observed. This suggests steady‐state conditions upon substrate addition, i.e. amino sugar formation equalled amino sugar decomposition. Furthermore, higher quality substrates seemed to favor the production of fungal‐derived amino sugars. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Conventional simultaneous CNS stable isotope abundance measurements of solid samples usually require high sample amounts, up to 1 mg carbon, to achieve exact analytical results. This rarely used application is often impaired by high C:S element ratios when organic samples are analyzed and problems such as incomplete conversion into sulphur dioxide occur during analysis. We introduce, as a technical innovation, a high sensitivity elemental analyzer coupled to a conventional isotope ratio mass spectrometer, with which CNS‐stable isotope ratios can be determined simultaneously in samples with low carbon content (<40 µg C corresponding to ~100 µg dry weight). The system includes downsized reactors, a temperature program‐controlled gas chromatography (GC) column and a cryogenic trap to collect small amounts of sulphur dioxide. This modified application allows for highly sensitive measurements in a fully automated operation with standard deviations better than ±0.47‰ for δ15N and δ34S and ±0.12‰ for δ13C (n = 127). Samples collected from one sampling site in a Baltic fjord within a short time period were measured with the new system to get a first impression of triple stable isotope signatures. The results confirm the potential of using δ34S as a stable isotope tracer in combination with δ15N and δ13C measurements to improve discrimination of food sources in aquatic food webs. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
An inter‐laboratory exercise was carried out by a consortium of five European laboratories to establish a set of compounds, suitable for calibrating gas chromatography/combustion/isotope ratio mass spectrometry (GC‐C‐IRMS) devices, to be used as isotopic reference materials for hydrogen, carbon, nitrogen and oxygen stable isotope measurements. The set of compounds was chosen with the aim of developing a mixture of reference materials to be used in analytical protocols to check for food and beverage authentication. The exercise was organized in several steps to achieve the certification level: the first step consisted of the a priori selection of chemical compounds on the basis of the scientific literature and successive GC tests to set the analytical conditions for each single compound and the mixture. After elimination of the compounds that turned out to be unsuitable in a multi‐compound mixture, some additional oxygen‐ and nitrogen‐containing substances were added to complete the range of calibration isotopes. The results of δ13C determinations for the entire set of reference compounds have previously been published, while the δD and δ18O determinations were unsuccessful and after statistical analysis of the data the results did not reach the level required for certification. In the present paper we present the results of an inter‐laboratory exercise to identify and test the set of nitrogen‐containing compounds present in the mixture developed for use as reference materials for the validation of GC‐C‐IRMS analyses in individual laboratories. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
An online method using continuous flow isotope ratio mass spectrometry (CF‐IRMS) interfaced with a Gasbench II device was established to analyze carbon and oxygen isotopic compositions and to estimate the content of minor amounts of carbonate in silicate rocks. The mixtures of standard materials and high‐purity quartz are firstly used to calibrate different quantities of carbonate in silicates. The results suggest that the accuracy and precision of the online analysis are both better than those obtained using an offline method. There is a positive correlation between the carbonate weight and the Mass44 ion beam intensity (or peak area). When the weight of carbonate in the mixtures is greater than 70 µg (equal to ~1800 mV Mass44 ion beam intensity), the δ13C and δ18O values of samples usually have accuracy and precision of ±0.1‰ and ±0.2‰ (1σ), respectively. If the weight is less than 70 µg, some limitations (e.g., not perfectly linear) are encountered that significantly reduce the accuracy and precision. The measured δ18O values are systematically lower than the true values by ?0.3 to ?0.7‰; the lower the carbonate content, the lower the measured δ18O value. For samples with lower carbonate content, the required phosphoric acid doses are higher and more oxygen isotope exchanges with the water in the phosphoric acid. To guarantee accurate results with high precision, multiple analyses of in‐house standards and an artificial MERCK sample with δ13C values from ?35.58 to 1.61‰ and δ18O from 6.04 to 18.96‰ were analyzed simultaneously with the unknown sample. This enables correction of the measured raw data for the natural sample based on multiple‐point normalization. The results indicate that the method can be successfully applied to a range of natural rocks. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
Conventional chemical profiling of methylamphetamine has been used for many years to determine the synthetic route employed and where possible to identify the precursor chemicals used. In this study stable isotope ratio analysis was investigated as a means of determining the origin of the methylamphetamine precursors, ephedrine and pseudoephedrine. Ephedrine and pseudoephedrine may be prepared industrially by several routes. Results are presented for the stable isotope ratios of carbon (δ13C), nitrogen (δ15N) and hydrogen (δ2H) measured in methylamphetamine samples synthesized from ephedrine and pseudoephedrine of known provenance. It is clear from the results that measurement of the δ13C, δ15N and δ2H stable isotope ratios by elemental analyzer/thermal conversion isotope ratio mass spectrometry (EA/TC‐IRMS) in high‐purity methylamphetamine samples will allow determination of the synthetic source of the ephedrine or pseudoephedrine precursor as being either of a natural, semi‐synthetic, or fully synthetic origin. Copyright © 2009 Commonwealth of Australia. Published by John Wiley & Sons, Ltd.  相似文献   

10.
An analytical line for stable isotope analyses of water recovered from fluid inclusions in minerals was built and successfully tested. The line is based on the principle of continuous‐flow analysis of water via high‐temperature reduction on glassy carbon. It includes a custom‐designed set of high‐efficiency crushers and a cryo‐focusing cell. This paper provides details of the line design and discusses strategies for line conditioning and mitigation of memory effects. The line allows measurements of hydrogen and oxygen isotopes during a single acquisition. The precision of the analyses depends on the amount of water released from the inclusions. The best results are obtained for samples containing at least 0.1–0.2 µL (0.06–0.11 µmol) H2O. For such samples precision is better than 1.5‰ for δD and 0.5‰ for δ18O (1σ). Smaller amounts of water can be measured but at lower precision. Analyses of modern calcite formed under stable conditions in a deep cave allowed assessment of the accuracy of the analyses. The δD values measured in fluid inclusions of this working standard match the δD value of the parent water, and the oxygen isotope values agree within ca. 0.5‰. This indicates that fluid inclusions trapped in calcite at near‐ambient temperatures (e.g. speleothems and low‐temperatures phreatic calcite) faithfully preserve the original isotopic composition of the parent waters. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Stable oxygen isotope compositions (δ18O values) of two commercial and one synthesized silver orthophosphate reagents have been determined on the VSMOW scale. The analyses were carried out in three different laboratories: lab (1) applying off‐line oxygen extraction in the form of CO2 which was analyzed on a dual inlet and triple collector isotope ratio mass spectrometer, while labs (2) and (3) employed an isotope ratio mass spectrometer coupled to a high‐temperature conversion/elemental analyzer (TC/EA) where Ag3PO4 samples were analyzed as CO in continuous flow mode. The δ18O values for the proposed new comparison materials were linked to the generally accepted δ18O values for Vennemann's TU‐1 and TU‐2 standards as well as for Ag3PO4 extracted from NBS120c. The weighted average δ18OVSMOW values for the new comparison materials UMCS‐1, UMCS‐2 and AGPO‐SCRI were determined to be + 32.60 (± 0.12), + 19.40 (± 0.12) and + 14.58 (± 0.13)‰, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
Hydrogen (δ2H) and oxygen (δ18O) stable isotope analysis is useful when tracing the origin of water in beverages, but traditional analytical techniques are limited to pure or extracted waters. We measured the isotopic composition of extracted beverage water using both isotope ratio infrared spectroscopy (IRIS; specifically, wavelength‐scanned cavity ring‐down spectroscopy) and isotope ratio mass spectrometry (IRMS). We also analyzed beer, sodas, juices, and milk ‘as is’ using IRIS. For IRIS analysis, four sequential injections of each sample were measured and data were corrected for sample‐to‐sample memory using injections (a) 1‐4, (b) 2‐4, and (c) 3‐4. The variation between δ2H and δ18O values calculated using the three correction methods was larger for unextracted (i.e., complex) beverages than for waters. The memory correction was smallest when using injections 3‐4. Beverage water δ2H and δ18O values generally fit the Global Meteoric Water Line, with the exception of water from fruit juices. The beverage water stable isotope ratios measured using IRIS agreed well with the IRMS data and fit 1:1 lines, with the exception of sodas and juices (δ2H values) and beers (δ18O values). The δ2H and δ18O values of waters extracted from beer, soda, juice, and milk were correlated with complex beverage δ2H and δ18O values (r = 0.998 and 0.997, respectively) and generally fit 1:1 lines. We conclude that it is possible to analyze complex beverages, without water extraction, using IRIS although caution is needed when analyzing beverages containing sugars, which can clog the syringe and increase memory, or alcohol, a known spectral interference. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Stable isotope ratios of individual plant components have become a valuable tool for the determination of the geographical origin and authenticity of foodstuff. A recently published method with considerable potential in this context is the measurement of the deuterium/hydrogen (D/H) isotope ratios of plant matter methoxyl groups. The method entailed cleavage of methyl ethers or esters with hydriodic acid (HI) to form gaseous methyl iodide (CH3I) and then measurement of the δ2H value of this gas. Here, as a follow up to a previous study, we describe a method for the rapid and precise δ13C analysis of plant matter methoxyl groups using gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Conditions for sample preparation were investigated for isotope discrimination effects, the GC conditions optimized, the reproducibility of the measurement of standards undertaken, and the precision of the method defined. The reproducibility of the δ13C value determined for a CH3I standard on 20 consecutive measurements was found to be 0.17‰. The method was also tested on four methoxyl‐rich plant components: vanillin, lignin, wood and pectin. The analytical precision obtained, expressed as the average standard deviation, for these compounds was found to be better than 0.13‰. The described procedure which is simple and rapid, allowing preparation and analysis of a sample within 1 h, produces accurate and reproducible isotopic measurements. We suggest that this validated δ13C method when employed together with the recently published δ2H method for two‐dimensional stable isotope studies of organic matter containing methoxyl groups will be of considerable value, e.g. for proving the authenticity of foodstuff. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Analytical details for 13C and 18O isotope analyses of atmospheric CO2 in large air samples are given. The large air samples of nominally 300 L were collected during the passenger aircraft‐based atmospheric chemistry research project CARIBIC and analyzed for a large number of trace gases and isotopic composition. In the laboratory, an ultra‐pure and high efficiency extraction system and high‐quality isotope ratio mass spectrometry were used. Because direct comparison with other laboratories was practically impossible, the extraction and measurement procedures were tested in considerable detail. Extracted CO2 was measured twice vs. two different working reference CO2 gases of different isotopic composition. The two data sets agree well and their distributions can be used to evaluate analytical errors due to isotope measurement, ion corrections, internal calibration consistency, etc. The calibration itself is based on NBS‐19 and also verified using isotope analyses on pure CO2 gases (NIST Reference Materials (RMs) and NARCIS CO2 gases). The major problem encountered could be attributed to CO2‐water exchange in the air sampling cylinders. This exchange decreased over the years. To exclude artefacts due to such isotopic exchange, the data were filtered to reject negative δ18O(CO2) values. Examples of the results are given. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
In order to generate a reliable and long‐lasting stable isotope ratio standard for CO2 in samples of clean air, CO2 is liberated from well‐characterized carbonate material and mixed with CO2‐free air. For this purpose a dedicated acid reaction and air mixing system (ARAMIS) was designed. In the system, CO2 is generated by a conventional acid digestion of powdered carbonate. Evolved CO2 gas is mixed and equilibrated with a prefabricated gas comprised of N2, O2, Ar, and N2O at close to ambient air concentrations. Distribution into glass flasks is made stepwise in a highly controlled fashion. The isotopic composition, established on automated extraction/measurement systems, varied within very small margins of error appropriate for high‐precision air‐CO2 work (about ±0.015‰ for δ13C and ±0.025‰ for δ18O). To establish a valid δ18O relation to the VPDB scale, the temperature dependence of the reaction between 25 and 47°C has been determined with a high level of precision. Using identical procedures, CO2‐in‐air mixtures were generated from a selection of reference materials; (1) the material defining the VPDB isotope scale (NBS 19, δ13C = +1.95‰ and δ18O = ?2.2‰ exactly); (2) a local calcite similar in isotopic composition to NBS 19 (‘MAR‐J1’, δ13C = +1.97‰ and δ18O = ?2.02‰), and (3) a natural calcite with isotopic compositions closer to atmospheric values (‘OMC‐J1’, δ13C = ?4.24‰ and δ18O = ?8.71‰). To quantitatively control the extent of isotope‐scale contraction in the system during mass spectrometric measurement other available international and local carbonate reference materials (L‐SVEC, IAEA‐CO‐1, IAEA‐CO‐8, CAL‐1 and CAL‐2) were also processed. As a further control pure CO2 reference gases (Narcis I and II, NIST‐RM 8563, GS19 and GS20) were mixed with CO2‐free synthetic air. Independently, the pure CO2 gases were measured on the dual inlet systems of the same mass spectrometers. The isotopic record of a large number of independent batches prepared over the course of several months is presented. In addition, the relationship with other implementations of the VPDB‐scale for CO2‐in‐air (e.g. CG‐99, based on calibration of pure CO2 gas) has been carefully established. The systematic high‐precision comparison of secondary carbonate and CO2 reference materials covering a wide range in isotopic composition revealed that assigned δ‐values may be (slightly) in error. Measurements in this work deviate systematically from assigned values, roughly scaling with isotopic distance from NBS 19. This finding indicates that a scale contraction effect could have biased the consensus results. The observation also underlines the importance of cross‐contamination errors for high‐precision isotope ratio measurements. As a result of the experiments, a new standard reference material (SRM), which consists of two 5‐L glass flasks containing air at 1.6 bar and the CO2 evolved from two different carbonate materials, is available for distribution. These ‘J‐RAS’ SRM flasks (‘Jena‐Reference Air Set’) are designed to serve as a high‐precision link to VPDB for improving inter‐laboratory comparability. a Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

16.
Carbon isotope analysis by bulk elemental analysis coupled with isotope ratio mass spectrometry has been the mainstay of δ13C analyses both at natural abundance and in tracer studies. More recently, compound‐specific isotope analysis (CSIA) has become established, whereby organic constituents are separated online by gas or liquid chromatography before oxidation and analysis of CO2 for constituent δ13C. Theoretically, there should be concordance between bulk δ13C measurements and carbon‐weighted δ13C measurements of carbon‐containing constituents. To test the concordance between the bulk and CSIA, fish oil was chosen because the majority of carbon in fish oil is in the triacylglycerol form and ~95% of this carbon is amenable to CSIA in the form of fatty acids. Bulk isotope analysis was carried out on aliquots of oil extracted from 55 fish samples and δ13C values were obtained. Free fatty acids (FFAs) were produced from the oil samples by saponification and derivatised to fatty acid methyl esters (FAMEs) for CSIA by gas chromatography/combustion/isotope ratio mass spectrometry. A known amount of an internal standard (C15:0 FAME) was added to allow analyte quantitation. This internal standard was also isotopically calibrated in both its FFA (δ13C = ?34.30‰) and FAME (δ13C = ?34.94‰) form. This allowed reporting of FFA δ13C from measured FAME δ13C values. The bulk δ13C was reconstructed from CSIA data based on each FFA δ13C and the relative amount of CO2 produced by each analyte. The measured bulk mean δ13C (SD) was ?23.75‰ (1.57‰) compared with the reconstructed bulk mean δ13C of ?23.76 (1.44‰) from CSIA and was not significantly different. Further analysis of the data by the Bland‐Altman method did not show particular bias in the data relative to the magnitude of the measurement. Good agreement between the methods was observed with the mean difference between methods (range) of 0.01‰ (?1.50 to 1.30). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
We report a novel method for the chromatographic separation and measurement of stable carbon isotope ratios (δ13C) of individual amino acids in hair proteins and bone collagen using the LC‐IsoLink system, which interfaces liquid chromatography (LC) with isotope ratio mass spectrometry (IRMS). This paper provides baseline separation of 15 and 13 of the 18 amino acids in bone collagen and hair proteins, respectively. We also describe an approach to analysing small hair samples for compound‐specific analysis of segmental hair sections. The LC/IRMS method is applied in a historical context by the δ13C analysis of hair proteins and bone collagen recovered from six individuals from Uummannaq in Greenland. The analysis of hair and bone amino acids from the same individual, compared for the first time in this study, is of importance in palaeodietary reconstruction. If hair proteins can be used as a proxy for bone collagen at the amino acid level, this validates compound‐specific isotope studies using hair as a model for palaeodietary reconstruction. Our results suggest that a small offset observed in the bulk δ13C values of the hair and bone samples may be attributed to two factors: (i) amino acid compositional differences between hair and bone proteins, and (ii) differential turnover rates of the tissues and the amino acid pools contributing to their synthesis. This application proposes that hair may be a useful complementary or alternative source of compound‐specific paleodietary information. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ 15N by elemental analysis (EA)–isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ 15N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH4NO3) and potassium nitrate (KNO3) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2—two ammonium sulphates [(NH4)2SO4]—and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V2O5) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ 15N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards.
Figure
Control chart of the δ 15N value of IAEA-N1, IAEA-NO-3 and NH4NO3 analysed a) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 18 s/20 s), b) with oxygen injection (analytical cycle 70 s, oxygen for 60 s, sample start and stop at 0 s/2 s and 5 s/7 s), c) without oxygen injection (analytical cycle 70 s, sample start and stop at 18 s/20 s).  相似文献   

19.
The chemical signals in the sequential layers of fish otoliths have the potential to provide fisheries biologists with temporal and spatial details of migration which are difficult to obtain without expensive tracking methods. Signal resolution depends, however, on the extraction technique used. We compared the use of mechanical micromilling and continuous flow isotope ratio mass spectrometry (CF‐IRMS) methods with secondary ion mass spectrometry (SIMS) to obtain δ18O profiles from otoliths of wild Atlantic salmon (Salmo salar) and used these to corroborate the time of freshwater emigration of the juvenile with macroscopic patterns within the otolith. Both techniques showed the transition occurring at the same visible feature on the otolith, allowing future analyses to easily identify the juvenile (freshwater) versus adult (marine) life‐stages. However, SIMS showed a rapid and abrupt transition whereas micromilling provided a less distinct signal. The number of samples that could be obtained per unit area sampled using SIMS was 2 to 3 times greater than that when using micromilling/CF‐IRMS although the δ18O values and analytical precisions (~0.2‰) of the two methods were comparable. In addition, SIMS δ18O results were used to compare otolith aragonite values with predicted values calculated using various isotope fractionation equations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
Gas chromatography‐combustion‐isotope ratio mass spectrometry (GC‐C‐IRMS) is increasingly applied to food and metabolic studies for stable isotope analysis (δ13C), with the quantification of analyte concentration often obtained via a second alternative method. We describe a rapid direct transesterification of triacylglycerides (TAGs) for fatty acid methyl ester (FAME) analysis by GC‐C‐IRMS demonstrating robust simultaneous quantification of amount of analyte (mean r2 = 0.99, accuracy ±2% for 37 FAMEs) and δ13C (±0.13‰) in a single analytical run. The maximum FAME yield and optimal δ13C values are obtained by derivatizing with 10% (v/v) acetyl chloride in methanol for 1 h, while lower levels of acetyl chloride and shorter reaction times skewed the δ13C values by as much as 0.80‰. A Bland‐Altman evaluation of the GC‐C‐IRMS measurements resulted in excellent agreement for pure oils (±0.08‰) and oils extracted from French fries (±0.49‰), demonstrating reliable simultaneous quantification of FAME concentration and δ13C values. Thus, we conclude that for studies requiring both the quantification of analyte and δ13C data, such as authentication or metabolic flux studies, GC‐C‐IRMS can be used as the sole analytical method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号