1.
The δ2HVSMOW–SLAP value of total hydrogen of the international measurement standard NBS 22 oil was determined by a new method of sealing water in silver tubes for use in a thermal conversion elemental analysis (TC/EA) reduction unit. The isotopic fractionation of water due to evaporation is virtually non‐existent in this silver‐tube method. A new value for the δ2HVSMOW–SLAP of NBS 22 oil, calibrated with isotopic reference waters, was determined to be ?116.9 ± 0.8‰ (1σ and n = 31). Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

2.
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the δ values of these reference materials should bracket the isotopic range of samples with unknown δ values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW‐SLAP) and carbonates (NBS 19 and L‐SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA‐IRMS). At present only L‐glutamic acids USGS40 and USGS41 satisfy these requirements for δ13C and δ15N, with the limitation that L‐glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on‐line (i.e. continuous flow) hydrogen reductive gas chromatography‐isotope ratio mass‐spectrometry (GC‐IRMS), (ii) five nicotines for oxidative C, N gas chromatography‐combustion‐isotope ratio mass‐spectrometry (GC‐C‐IRMS, or GC‐IRMS), and (iii) also three acetanilide and three urea reference materials for on‐line oxidative EA‐IRMS for C and N. Isotopic off‐line calibration against international stable isotope measurement standards at Indiana University adhered to the ‘principle of identical treatment’. The new reference materials cover the following isotopic ranges: δ2Hnicotine ?162 to ?45‰, δ13Cnicotine ?30.05 to +7.72‰, δ15Nnicotine ?6.03 to +33.62‰; δ15Nacetanilide +1.18 to +40.57‰; δ13Curea ?34.13 to +11.71‰, δ15Nurea +0.26 to +40.61‰ (recommended δ values refer to calibration with NBS 19, L‐SVEC, IAEA‐N‐1, and IAEA‐N‐2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC‐IRMS that are available with different δ15N values. Comparative δ13C and δ15N on‐line EA‐IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA‐IRMS reference materials. Published in 2009 by John Wiley & Sons, Ltd.  相似文献   

3.
A method for online simultaneous δ2H and δ18O analysis in water by high‐temperature conversion is presented. Water is injected by using a syringe into a high‐temperature carbon reactor and converted into H2 and CO, which are separated by gas chromatography (GC) and carried by helium to the isotope ratio mass spectrometer for hydrogen and oxygen isotope analysis. A series of experiments was conducted to evaluate several issues such as sample size, temperature and memory effects. The δ2H and δ18O values in multiple water standards changed consistently as the reactor temperature increased from 1150 to 1480°C. The δ18O in water can be measured at a lower temperature (e.g. 1150°C) although the precision was relatively poor at temperatures <1300°C. Memory effects exist for δ2H and δ18O between two waters, and can be reduced (to <1%) with proper measures. The injection of different amounts of water may affect the isotope ratio results. For example, in contrast to small injections (100 nL or less) from small syringes (e.g. 1.2 µL), large injections (1 µL or more) from larger syringes (e.g. 10 µL) with dilution produced asymmetric peaks and shifts of isotope ratios, e.g. 4‰ for δ2H and 0.4‰ for δ18O, probably resulting from isotope fractionation during dilution via the ConFlo interface. This method can be used to analyze nanoliter samples of water (e.g. 30 nL) with good precision of 0.5‰ for δ2H and 0.1‰ for δ18O. This is important for geosciences; for instance, fluid inclusions in ancient minerals may be analyzed for δ2H and δ18O to help understand the formation environments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high‐temperature conversion techniques (HTC) a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:
Reference material δ18O and estimated combined uncertainty c
IAEA‐602 benzoic acid +71.28 ± 0.36‰
USGS35 sodium nitrate +56.81 ± 0.31‰
IAEA‐NO‐3 potassium nitrate +25.32 ± 0.29‰
IAEA‐601 benzoic acid +23.14 ± 0.19‰
IAEA‐SO‐5 barium sulfate +12.13 ± 0.33‰
NBS 127 barium sulfate +8.59 ± 0.26‰
VSMOW2 water 0‰
IAEA‐600 caffeine ?3.48 ± 0.53‰
IAEA‐SO‐6 barium sulfate ?11.35 ± 0.31‰
USGS34 potassium nitrate ?27.78 ± 0.37‰
SLAP water ?55.5‰
The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3‐fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen‐isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA‐NO‐3, and USGS35), sulfates (IAEA‐SO‐5, IAEA‐SO‐6, and NBS 127), or organic material (IAEA‐601 benzoic acid, IAEA‐602 benzoic acid, and IAEA‐600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary. The high‐temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well‐established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Isotope ratio monitoring gas chromatography‐mass spectrometry of the 2H/1H ratio by pyrolysis isotope ratio mass spectrometry (P‐IRMS) was used to analyze benzaldehyde originating from various sources. Based on the δ2HSMOW value of an authentic reference sample determined with an elemental analyzer (EA), the range of reproducibility and linearity was checked. Correct (EA related) and reproducible data were obtained for sample amounts >0.6 μg benzaldehyde (on column). In another series of experiments, the influence of sample preparation, i. e. simultaneous distillation‐extraction (SDE) was found to be negligible. The following ranges of δ2HSMOW values were determined for benzaldehyde using five types of samples, i. e. (i) synthetic (δ2HSMOW –78 to –85‰, ex benzal chloride; +420 to +668‰, ex toluene) and ‘natural’ (including ‘ex‐cassia’) references (δ2HSMOW –83 to –144‰); (ii) bitter almond oils (δ2HSMOW –113 to –148‰); (iii) fruits (δ2HSMOW –111 to –146‰); (iv) kernels (δ2HSMOW –115 to –188‰); and (v) leaves (δ2HSMOW –165 to –189‰).  相似文献   

6.
A Delta Plus XL continuous flow gas chromatography/high‐temperature conversion‐isotope ratio mass spectrometer system (GC‐TC‐IRMS) with a liquid nitrogen trap installed at the end of the micropyrolysis oven was used to measure hydrogen isotope (δ2H) values of 1,2‐dichloroethane (1,2‐DCA). The 1,2‐DCA δ2H values were within uncertainty of the δ2H value for the same 1,2‐DCA analyzed using off‐line sample preparation and conventional dual inlet mass spectrometry, verifying that this system can accurately measure 1,2‐DCA δ2H values. After 71 reproducible and accurate 1,2‐DCA δ2H measurements had been obtained, the standard deviation on the mean of the cumulative 1,2‐DCA δ2H measurements was greater than ±5‰. The cumulative load of chlorine at this point was ~5.5 × 10?6 moles, which may be the limit to the quantity of chlorine that can be input before the reproducibility of 1,2‐DCA δ2H measurements is compromised. This study is the first to our knowledge to demonstrate a method for obtaining accurate and reproducible compound‐specific δ2H values for chlorinated hydrocarbons at dissolved concentrations typical of field conditions. Paired δ2H and δ13C values suggest that dual parameter isotopic measurements can distinguish between different contaminant sources, as well as providing additional constraints on degradation pathways and contaminant remediation. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
The 18O and 2H of water vapor serve as powerful tracers of hydrological processes. The typical method for determining water vapor δ18O and δ2H involves cryogenic trapping and isotope ratio mass spectrometry. Even with recent technical advances, these methods cannot resolve vapor composition at high temporal resolutions. In recent years, a few groups have developed continuous laser absorption spectroscopy (LAS) approaches for measuring δ18O and δ2H which achieve accuracy levels similar to those of lab‐based mass spectrometry methods. Unfortunately, most LAS systems need cryogenic cooling and constant calibration to a reference gas, and have substantial power requirements, making them unsuitable for long‐term field deployment at remote field sites. A new method called Off‐Axis Integrated Cavity Output Spectroscopy (OA‐ICOS) has been developed which requires extremely low‐energy consumption and neither reference gas nor cryogenic cooling. In this report, we develop a relatively simple pumping system coupled to a dew point generator to calibrate an ICOS‐based instrument (Los Gatos Research Water Vapor Isotope Analyzer (WVIA) DLT‐100) under various pressures using liquid water with known isotopic signatures. Results show that the WVIA can be successfully calibrated using this customized system for different pressure settings, which ensure that this instrument can be combined with other gas‐sampling systems. The precisions of this instrument and the associated calibration method can reach ~0.08‰ for δ18O and ~0.4‰ for δ2H. Compared with conventional mass spectrometry and other LAS‐based methods, the OA‐ICOS technique provides a promising alternative tool for continuous water vapor isotopic measurements in field deployments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Stable isotopes of water have been previously used in catchment studies to separate rain‐event water from pre‐event groundwater. However, there are a lack of studies at the smaller scale looking at the separation of event water from pre‐event water. This is particularly relevant for heavy clay soil systems through which the movement of water is uncertain but is thought to be rainwater‐dominated. The data presented here were collected at a rural site in the south‐west of England. The historic rainfall at the site was isotopically varied but similar to the global meteoric water line, with annual weighted means of ?37‰ for δ2H and ?5.7‰ for δ18O and with no seasonal variation. Drainage was sampled from the inter‐flow (surface runoff + lateral through‐flow) and drain‐flow (55 cm deep mole drains) pathways of two 1 ha lysimeters during two rainfall events, which had δ2H values of ?68‰ and ?92‰, respectively. The δ2H values of the lysimeter drainage water suggest that there was no contribution of event water during the first, small discharge (Q) event; however, the second larger event did show isotopic variation in δ2H values negatively related to Q indicating that rainwater was contributing to Q. A hydrograph separation indicated that only 49–58% of the inter‐flow and 18–25% of the drain‐flow consisted of event water. This was surprising given that these soil types are considered retentive of soil water. More work is needed on heavy clay soils to understand better the nature of water movement from these systems. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
An analytical line for stable isotope analyses of water recovered from fluid inclusions in minerals was built and successfully tested. The line is based on the principle of continuous‐flow analysis of water via high‐temperature reduction on glassy carbon. It includes a custom‐designed set of high‐efficiency crushers and a cryo‐focusing cell. This paper provides details of the line design and discusses strategies for line conditioning and mitigation of memory effects. The line allows measurements of hydrogen and oxygen isotopes during a single acquisition. The precision of the analyses depends on the amount of water released from the inclusions. The best results are obtained for samples containing at least 0.1–0.2 µL (0.06–0.11 µmol) H2O. For such samples precision is better than 1.5‰ for δD and 0.5‰ for δ18O (1σ). Smaller amounts of water can be measured but at lower precision. Analyses of modern calcite formed under stable conditions in a deep cave allowed assessment of the accuracy of the analyses. The δD values measured in fluid inclusions of this working standard match the δD value of the parent water, and the oxygen isotope values agree within ca. 0.5‰. This indicates that fluid inclusions trapped in calcite at near‐ambient temperatures (e.g. speleothems and low‐temperatures phreatic calcite) faithfully preserve the original isotopic composition of the parent waters. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Revised δ34S reference values with associated expanded uncertainties (95% confidence interval (C.I.)) are presented for the sulfur isotope reference materials IAEA‐S‐2 (22.62 ± 0.16‰) and IAEA‐S‐3 (−32.49 ± 0.16‰). These revised values are determined using two relative‐difference measurement techniques, gas source isotope ratio mass spectrometry (GIRMS) and double‐spike multi‐collector thermal ionization mass spectrometry (MC‐TIMS). Gas analyses have traditionally been considered the most robust for relative isotopic difference measurements of sulfur. The double‐spike MC‐TIMS technique provides an independent method for value‐assignment validation and produces revised values that are both unbiased and more precise than previous value assignments. Unbiased δ34S values are required to anchor the positive and negative end members of the sulfur delta (δ) scale because they are the basis for reporting both δ34S values and the derived mass‐independent Δ33S and Δ36S values. Published in 2009 by John Wiley & Sons, Ltd.  相似文献   

11.
The thermal conversion/elemental analyzer‐isotope ratio mass spectrometer (TC/EA‐IRMS) is widely used to measure the δ18O value of various substances. A premise for accurate δ18O measurement is that the oxygen in the sample can be converted into carbon monoxide (CO) quantitatively or at least proportionally. Therefore, a precise method to determine the oxygen yield of TC/EA‐IRMS measurements is needed. Most studies have used the CO peak area obtained from a known amount of a solid reference material (for example, benzoic acid) to calibrate the oxygen yield of the sample. Although it was assumed that the oxygen yield of the solid reference material is 100%, no direct evidence has been provided. As CO is the analyte gas for δ18O measurement by IRMS, in this study, we use a six‐port valve to inject CO gas into the TC/EA. The CO is carried to the IRMS by the He carrier gas and the CO peak area is measured by the IRMS. The CO peak area thus obtained from a known amount of the injected CO is used to calibrate the oxygen yield of the sample. The oxygen yields of commonly used organic and inorganic reference materials such as benzoic acid (C6H5COOH), silver phosphate (Ag3PO4), calcium carbonate (CaCO3) and silicon dioxide (SiO2) are investigated at different reactor temperatures and sample sizes. We obtained excellent linear correlation between the peak area for the injected CO and its oxygen atom amount. C6H5COOH has the highest oxygen yield, followed by Ag3PO4, CaCO3 and SiO2. The oxygen yields of TC/EA‐IRMS are less than 100% for both organic and inorganic substances, but the yields are relatively stable at the specified reactor temperature and for a given quantity of sample. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
In order to generate a reliable and long‐lasting stable isotope ratio standard for CO2 in samples of clean air, CO2 is liberated from well‐characterized carbonate material and mixed with CO2‐free air. For this purpose a dedicated acid reaction and air mixing system (ARAMIS) was designed. In the system, CO2 is generated by a conventional acid digestion of powdered carbonate. Evolved CO2 gas is mixed and equilibrated with a prefabricated gas comprised of N2, O2, Ar, and N2O at close to ambient air concentrations. Distribution into glass flasks is made stepwise in a highly controlled fashion. The isotopic composition, established on automated extraction/measurement systems, varied within very small margins of error appropriate for high‐precision air‐CO2 work (about ±0.015‰ for δ13C and ±0.025‰ for δ18O). To establish a valid δ18O relation to the VPDB scale, the temperature dependence of the reaction between 25 and 47°C has been determined with a high level of precision. Using identical procedures, CO2‐in‐air mixtures were generated from a selection of reference materials; (1) the material defining the VPDB isotope scale (NBS 19, δ13C = +1.95‰ and δ18O = ?2.2‰ exactly); (2) a local calcite similar in isotopic composition to NBS 19 (‘MAR‐J1’, δ13C = +1.97‰ and δ18O = ?2.02‰), and (3) a natural calcite with isotopic compositions closer to atmospheric values (‘OMC‐J1’, δ13C = ?4.24‰ and δ18O = ?8.71‰). To quantitatively control the extent of isotope‐scale contraction in the system during mass spectrometric measurement other available international and local carbonate reference materials (L‐SVEC, IAEA‐CO‐1, IAEA‐CO‐8, CAL‐1 and CAL‐2) were also processed. As a further control pure CO2 reference gases (Narcis I and II, NIST‐RM 8563, GS19 and GS20) were mixed with CO2‐free synthetic air. Independently, the pure CO2 gases were measured on the dual inlet systems of the same mass spectrometers. The isotopic record of a large number of independent batches prepared over the course of several months is presented. In addition, the relationship with other implementations of the VPDB‐scale for CO2‐in‐air (e.g. CG‐99, based on calibration of pure CO2 gas) has been carefully established. The systematic high‐precision comparison of secondary carbonate and CO2 reference materials covering a wide range in isotopic composition revealed that assigned δ‐values may be (slightly) in error. Measurements in this work deviate systematically from assigned values, roughly scaling with isotopic distance from NBS 19. This finding indicates that a scale contraction effect could have biased the consensus results. The observation also underlines the importance of cross‐contamination errors for high‐precision isotope ratio measurements. As a result of the experiments, a new standard reference material (SRM), which consists of two 5‐L glass flasks containing air at 1.6 bar and the CO2 evolved from two different carbonate materials, is available for distribution. These ‘J‐RAS’ SRM flasks (‘Jena‐Reference Air Set’) are designed to serve as a high‐precision link to VPDB for improving inter‐laboratory comparability. a Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

13.
Stable oxygen isotope compositions (δ18O values) of two commercial and one synthesized silver orthophosphate reagents have been determined on the VSMOW scale. The analyses were carried out in three different laboratories: lab (1) applying off‐line oxygen extraction in the form of CO2 which was analyzed on a dual inlet and triple collector isotope ratio mass spectrometer, while labs (2) and (3) employed an isotope ratio mass spectrometer coupled to a high‐temperature conversion/elemental analyzer (TC/EA) where Ag3PO4 samples were analyzed as CO in continuous flow mode. The δ18O values for the proposed new comparison materials were linked to the generally accepted δ18O values for Vennemann's TU‐1 and TU‐2 standards as well as for Ag3PO4 extracted from NBS120c. The weighted average δ18OVSMOW values for the new comparison materials UMCS‐1, UMCS‐2 and AGPO‐SCRI were determined to be + 32.60 (± 0.12), + 19.40 (± 0.12) and + 14.58 (± 0.13)‰, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
Carbon isotope analysis by bulk elemental analysis coupled with isotope ratio mass spectrometry has been the mainstay of δ13C analyses both at natural abundance and in tracer studies. More recently, compound‐specific isotope analysis (CSIA) has become established, whereby organic constituents are separated online by gas or liquid chromatography before oxidation and analysis of CO2 for constituent δ13C. Theoretically, there should be concordance between bulk δ13C measurements and carbon‐weighted δ13C measurements of carbon‐containing constituents. To test the concordance between the bulk and CSIA, fish oil was chosen because the majority of carbon in fish oil is in the triacylglycerol form and ~95% of this carbon is amenable to CSIA in the form of fatty acids. Bulk isotope analysis was carried out on aliquots of oil extracted from 55 fish samples and δ13C values were obtained. Free fatty acids (FFAs) were produced from the oil samples by saponification and derivatised to fatty acid methyl esters (FAMEs) for CSIA by gas chromatography/combustion/isotope ratio mass spectrometry. A known amount of an internal standard (C15:0 FAME) was added to allow analyte quantitation. This internal standard was also isotopically calibrated in both its FFA (δ13C = ?34.30‰) and FAME (δ13C = ?34.94‰) form. This allowed reporting of FFA δ13C from measured FAME δ13C values. The bulk δ13C was reconstructed from CSIA data based on each FFA δ13C and the relative amount of CO2 produced by each analyte. The measured bulk mean δ13C (SD) was ?23.75‰ (1.57‰) compared with the reconstructed bulk mean δ13C of ?23.76 (1.44‰) from CSIA and was not significantly different. Further analysis of the data by the Bland‐Altman method did not show particular bias in the data relative to the magnitude of the measurement. Good agreement between the methods was observed with the mean difference between methods (range) of 0.01‰ (?1.50 to 1.30). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
A new analytical technique is described for the determination of δ34S that is comparable to or better than modern gas source mass spectrometry in precision and accuracy, but requires about a factor of 10 less sample. The technique is based on the production of singularly charged arsenic sulfide molecular ions (AsS+) by thermal ionization using silica gel as an emitter and combines multiple‐collector thermal ionization mass spectrometry (MC‐TIMS) with a 33S‐36S double spike to correct instrumental fractionation. Three international sulfur standards (IAEA‐S‐1, IAEA‐S‐2, and IAEA‐S‐3) were measured to evaluate the precision and accuracy of the new technique and to evaluate the consensus values for these standards. Two different double spike preparations were used. The δ34S values (reported relative to Vienna Canyon Diablo Troilite (VCDT), (δ34S (‰) = ([((34S/32S)sample/(34S/32S)VCDT ? 1) × 1000]), 34S/32SVCDT = 0.0441626) determined were ?0.32 ± 0.04‰ (1σ, n = 4) and ?0.31 ± 0.13‰ (1σ, n = 8) for IAEA‐S‐1, 22.65 ± 0.04‰ (1σ, n = 7) and 22.60 ± 0.06‰ (1σ, n = 5) for IAEA‐S‐2, and ?32.47 ± 0.07‰ (1σ, n = 8) for IAEA‐S‐3. The amount of natural sample used for these analyses ranged from 0.40 to 2.35 µmol. Replicate determinations of each standard showed less than 0.5‰ variability (IAEA‐S‐1 <0.4‰, IAEA‐S‐2 <0.2‰, and IAEA‐S‐3 <0.2‰). Because the technique is based on thermal ionization of AsS+, and As is mononuclidic, corrections for interferences or for scale contraction/expansion are not required. The availability of MC‐TIMS instruments in laboratories around the world makes this technique immediately available to a much larger scientific community who require highly accurate and precise measurements of sulfur. Published in 2005 by John Wiley & Sons, Ltd.  相似文献   

16.
The molecular composition of plant residues is suspected to largely govern the fate of their constitutive carbon (C) in soils. Labile compounds, such as metabolic carbohydrates, are affected differently from recalcitrant and structural compounds by soil‐C stabilisation mechanisms. Producing 13C‐enriched plant residues with specifically labeled fractions would help us to investigate the fate in soils of the constitutive C of these compounds. The objective of the present research was to test 13C pulse chase labeling as a method for specifically enriching the metabolic carbohydrate components of plant residues, i.e. soluble sugars and starch. Bean plants were exposed to a 13CO2‐enriched atmosphere for 0.5, 1, 2, 3 and 21 h. The major soluble sugars were then determined on water‐soluble extracts, and starch on HCl‐hydrolysable extracts. The results show a quick differential labeling between water‐soluble and water‐insoluble compounds. For both groups, 13C‐labeling increased linearly with time. The difference in δ13C signature between water‐soluble and insoluble fractions was 7‰ after 0.5 h and 70‰ after 21 h. However, this clear isotopic contrast masked a substantial labeling variability within each fraction. By contrast, metabolic carbohydrates on the one hand (i.e. soluble sugars + starch) and other fractions (essentially cell wall components) on the other hand displayed quite homogeneous signatures within fractions, and a significant difference in labeling between fractions: δ13C = 414 ± 3.7‰ and 56 ± 5.5‰, respectively. Thus, the technique generates labeled plant residues displaying contrasting 13C‐isotopic signatures between metabolic carbohydrates and other compounds, with homogenous signatures within each group. Metabolic carbohydrates being labile compounds, our findings suggest that the technique is particularly appropriate for investigating the effect of compound lability on the long‐term storage of their constitutive C in soils. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
Isoprene is one of the most important non‐methane hydrocarbons (NMHCs) in the troposphere: it is a significant precursor of O3 and it affects the oxidative state of the atmosphere. The diastereoisomeric 2‐methyltetrols, 2‐methylthreitol and 2‐methylerythritol, are marker compounds of the photooxidation products of atmospheric isoprene. In order to obtain valuable information on the δ13C value of isoprene in the atmosphere, the stable carbon isotopic compositions of the 2‐methyltetrols in ambient aerosols were investigated. The 2‐methyltetrols were extracted from filter samples and derivatized with methylboronic acid, and the δ13C values of the methylboronate derivatives were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The δ13C values of the 2‐methyltetrols were then calculated through a simple mass balance equation between the 2‐methyltetrols, methylboronic acid and the methylboronates. The δ13C values of the 2‐methyltetrols in aerosol samples collected at the Changbai Mountain Nature Reserves in eastern China were found to be ?24.66 ± 0.90‰ and ?24.53 ± 1.08‰ for 2‐methylerythritol and 2‐methylthreitol, respectively. Based on the measured isotopic composition of the 2‐methyltetrols, the average δ13C value of atmospheric isoprene is inferred to be close to or slightly heavier than ?24.66‰ at the collection site during the sampling period. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
The δ15N signature of plants integrates various processes in soil and plant. In this study, the effect of different water regimes applied during the period of grain growth of winter wheat on grain δ15N was examined in a 4‐year field experiment. The treatments comprised water shortage (S), an ample water supply (W), and rain‐fed crop (R). Zero fertilization (N0) and 200 kg N.ha?1 in mineral fertilizer (N1) treatments were studied. The grain 15N was determined during grain growth and at maturity. The water regime, nitrogen application and year had a significant effect on mature grain δ15N (p < 0.001). Water and nitrogen explained 54.6% of the variability of δ15N in the experiment, the year accounted for 10.7% and the interactions for another 19.6% of the total variability. The analysis of non‐mature grain δ15N showed significant effects of N and year but not of water. Nitrogen fertilization reduced the δ15N of mature grain in years by 0.7–6.3‰ in comparison with N0 plants; the reduction was more pronounced under stress (average reduction by 4.1‰) than under rain‐fed (2.4‰) and ample water supply (2.2‰). Water stress decreased the grain δ15N in fertilized wheat, by 0.1–2.1‰ and 0.6–3.6‰ in experimental years, on average by 1.30‰ and 1.79‰ in comparison with the R and W water supply, respectively. The effect of water supply was not significant in non‐fertilized wheat. A significant negative linear relationship between grain N concentration and δ15N in maturity or during the grain growth (R2 = 0.83, R2 = 0.76, respectively) was found. The observed sources of grain δ15N variability should be taken into consideration when analyzing and interpreting the data on the δ15N signature of plant material from field conditions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
We present a method for in situ sulphur (S) isotopic analysis of significantly small areas (1.5 µm in diameter) in pyrite using secondary ion mass spectrometry (NanoSIMS) to interpret microbial sulphur metabolism in the early earth. We evaluated the precision and accuracy of S isotopic ratios obtained by this method using hydrothermal pyrite samples with homogeneous S isotopic ratios. The internal precision of the δ34S value was 1.5‰ at the level of 1 sigma of standard error (named 1SE) for a single spot, while the external reproducibility was estimated to be 1.6‰ at the level of 1 sigma of standard deviation (named 1SD, n = 25). For each separate sample, the average δ34S value was comparable with that measured by a conventional method, and the accuracy was better than 2.3‰. Consequently, the in situ method is sufficiently accurate and precise to detect the S isotopic variations of small sample of the pyrite (less than 20 µm) that occurs ubiquitously in ancient sedimentary rocks. This method was applied to measure the S isotopic distribution of pyrite within black chert fragments in early Archean sandstone. The pyrite had isotopic zoning with a 34S‐depleted core and 34S‐enriched rim, suggesting isotopic evolution of the source H2S from ?15 to ?5‰. Production of H2S by microbial sulphate reduction (MSR) in a closed system provides a possible explanation for both the 34S‐depleted initial H2S and the progressive increase in the δ34SH2S value. Although more extensive data are necessary to strengthen the explanation for the origin of the MSR, the results show that the S isotopic distribution within pyrite crystals may be a key tracer for MSR activity in the early earth. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
Observations made during the 13C isotope analysis of gaseous CO2 in the simultaneous presence of argon in the ion source of the isotope ratio mass spectrometer prompted us to investigate what influence the simultaneous presence of nitrogen would have on both accuracy and precision of bulk 2H isotope analysis of nitrogen‐rich organic compounds. Initially an international reference material, IAEA‐CH7, was mixed with silver nitrate in various ratios to assess the impact that N2 evolved from the pyrolysis of nitrogen‐rich organic compounds would have on measured δ2H‐values of IAEA‐CH7. In a subsequent experiment, benzoic acid was mixed with silver nitrate to mimic the N:H ratio of organic‐rich nitrogen compounds such as cellulose nitrate and RDX. The results of both experiments showed a significant deterioration of both accuracy and precision for the expected δ2H values for IAEA‐CH7 and benzoic acid when model mixtures were converted into hydrogen and nitrogen, and subsequently separated by gas chromatography using standard experimental conditions, namely a 60 cm packed column with molecular sieve 5 Å as stationary phase held at a temperature of 85°C. It was found that bulk 2H stable isotope analysis of nitrogen‐rich organic compounds employing published standard conditions can result in a loss of accuracy and precision yielding δ2H values that are 5 to 25‰ too negative, thus suggesting, for example, that tree‐ring 2H isotope data based on cellulose nitrate may have to be revised. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   