首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Theoretical backgrounds, development, examples of separations, constructional details and principle of action of devices of pressurized planar electrochromatography (PPEC) are presented. Development of the mode is described in respect of operating variables (composition of the mobile phase, pressure exerted on adsorbent layer, mobile phase flow velocity, temperature of separating system, etc.) influencing separation efficiency (kinetic performance, repeatability, separation time). Advantages of PPEC such as high kinetic performance, short separation time and different separation selectivities, especially relative to conventional thin-layer chromatography, are described. Examples of two-dimensional separations are demonstrated to show high separation potential of the mode when combined with conventional thin-layer chromatography (TLC). The PPEC mode is in infancy stage of development, so its challenges are presented as well.  相似文献   

2.
Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liquid chromatography, especially thin layer chromatography (planar chromatography, TLC), are features of this technique. Constructional methodological challenges to PPEC are obstacles to its development and application in laboratory practice. In this article, an attempt to overcome the challenges related to device construction and sample application/injection is described. The introduced device enables both prewetting of the adsorbent layer and electrochromatogram development with a single PPEC device. It also enables simultaneous application/injection of six samples on a chromatographic plate in a stream of the mobile phase (on-line application/injection). In addition, the PPEC chamber was equipped with a thermostat. The device is characterized by an impressive throughput in comparison to the other planar technique, TLC/HPTLC. Although the developed device still needs improvement, it is, in our opinion, a considerable step toward possible automation of this planar separation technique.  相似文献   

3.
Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 μm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones.  相似文献   

4.
Three modes of sample application on the chromatographic plate are applied at present investigations of pressurized planar electrochromatography (PPEC) systems taking into special attention their influence on performance of the separating system. These modes are as follows: application of the sample solution directly on the chromatographic plate with microsyringe, deposition of sample solution on scrap of adsorbent layer followed by location oft this scrap on the chromatographic plate, application of the sample solution with commercially available aerosol applicator. These modes were combined with prewetting procedures of the chromatographic plates which lead to an accomplishment of equilibration of the stationary phase-mobile phase system. The plots of plate height versus linear flow rate of the mobile phase are presented for PPEC systems for the first time. The best separation performance has been obtained in PPEC system when prewetting of the chromatographic plate followed the sample application with commercially available aerosol applicator. The higher repeatability of migration distance of the solute bands has been obtained in PPEC experiments when the sample application was followed by prewetting the chromatographic plate in comparison to the experiments when these operations were performed in reversed order.  相似文献   

5.
In our previous paper we have presented the new prototype equipment and introduced a new analytical technique—high-performance/high-pressure layer electrochromatography (HPLEC), a combination of overpressured-layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC). In this paper, the work of the equipment in various operational modes is investigated. Some difficulties and challenges related to various aspects of separation are discussed. The OPLC and HPLEC techniques are compared in terms of selectivity and performance. The results show that our equipment can be successfully used for singe- and multichannel OPLC and HPLEC separations in various sample application and detection modes. It includes the high-throughput, multichannel, and fully automated online separation of multiple samples simultaneously. The equipment allows for the independent optimization of various operational parameters. HPLEC combines the advantages of column/capillary and planar separation techniques while overcoming their limitations. It also combines the advantages and overcomes the drawbacks of OPLC and PPEC. It provides hydrodynamic flow of the mobile phase, irrespective of the voltage used and/or the mobile phase composition. Thus, any optimization of the composition and the voltage can be used independently. Both can be used to obtain the required selectivity of separation. The voltage can be used to facilitate the mobile phase flow and accelerate the analysis.  相似文献   

6.
Influence of buffer pH, buffer concentration and ratio of methanol to acetonitrile in ternary mobile phase on migration distance of enantiomers of phenylalanine, tyrosine and DOPA in pressurized planar electrochromatography (PPEC) and thin-layer chromatography (TLC) systems is presented and compared. The applied operating variables in PPEC system more strongly influence on separation selectivity of investigated solutes than those in TLC one. Higher separation efficiency of PPEC system relative to TLC one is also demonstrated.  相似文献   

7.
The aim of this work was to find a relationship between electroosmotic flow (EOF) velocity of the mobile phase in pressurized planar electrochromatography (PPEC) and physicochemical properties like zeta potential, dielectric constant, and viscosity of the mobile phase as well as its composition. The study included different types of organic modifiers (acetonitrile, methanol, ethanol, acetone, formamide, N-methylformamide and N,N-dimethylformamide) in the full concentration range. In all experiments, chromatographic glass plates HPTLC RP-18 W from Merck (Darmstadt) were used as a stationary phase. During the study we found that there is no linear correlation between EOF velocity of the mobile phase and single variables such as zeta potential or dielectric constant or viscosity. However, there is quite strong linear correlation between EOF velocity of the mobile phase and variable obtained by multiplying zeta potential of the stationary phase–mobile phase interface, by dielectric constant of the mobile phase solution and dividing by viscosity of the mobile phase. Therefore, it could be concluded that the PPEC system fulfilled the Helmholtz–Smoluchowski equation.  相似文献   

8.
Preliminary results of 2‐D separation of test dye mixture using high‐performance thin‐layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC) are demonstrated. The advantage of 2‐D HPTLC/PPEC separation is based on different separation selectivities obtained in both HPTLC and PPEC systems. HPTLC RP18 W plates of 5×20 cm from Merck were used in the investigations. In the first dimension, a HPTLC process was performed using 5 cm length of the plate and in the second dimension PPEC separation was obtained applying plate of 20 cm length. PPEC process followed prewetting the chromatographic plate with sample zones on it, which were partly separated after first dimensional (HPTLC) separation. In the experiments, the modified version of PPEC device for 20 cm long chromatographic plate and the reservoir for prewetting the adsorbent layer were applied.  相似文献   

9.
The enantiomeric separations of five chiral pesticides, diclofopmethyl, 1; benalaxy, 2; acetofenate, 3; myclobutanil, 4; and difenoconazole, 5, were conducted on a Chiralpak IB-H column by a packed-column supercritical fluid chromatography (p-SFC). All compounds, except difenoconazole and myclobutanil, were well resolved within 10 min. As the mobile phase polarity decreased through changing the percentage and the type of alcohol modifiers in the supercritical carbon dioxide (CO(2)), the retention time, the separation factors, and the resolution increased. However, based on the retention time and the resolution, the optimized separations were obtained with the mobile phase containing 10% 2-propanol for diclofop-methyl 1; benalaxy, 2; myclobutanil, 4; difenoconazole, 5; and containing 3% 2-propanol for acetofenate, 3. The optimized separation temperature was at 35°C under the supercritical fluid condition. The π-π interactions and the hydrogen bonding interactions between Chiralpak IB-H CSP and the analytes might be the main chiral discriminations on enantioseparation of these five pesticides.  相似文献   

10.
Twenty chiral pesticides were tested, of which seven samples were directly separated by HPLC using cellulose tris-3,5-dimethyl carbamate (CDMPC) chiral stationary phase under RP conditions. The influence of mobile phase composition and column temperatures from 0 degrees C to 40 degrees C on the separations were investigated. The mobile phases were methanol/water or ACN/water at a flow rate of 0.8 mL/min with UV detection at 230 or 210 nm. Epoxiconazole, terallethrin, benalaxyl, and diclofopmethyl were observed to obtain the baseline separation under suitable conditions and other pesticides pyriproxyfen, lactofen, and quizalofop-ethyl were separated partially. The retention factors (k) and selectivity factor (alpha) for the enantiomers of most investigated pesticides decreased upon increasing the temperature except for the selectivity factors (alpha) of pyriproxyfen in methanol/water. The ln alpha - 1/T plots for racemic chiral pesticides were linear at the range of 0-40 except for that of pyriproxyfen enantiomers in methanol/water and the chiral separations were controlled by enthalpy. Better separations were not always at low temperature. The elution orders of the eluting enantiomers were determined by a circular dichroism (CD) detector.  相似文献   

11.
The direct chiral separations of pesticide enantiomers by high-performance liquid chromatography by applying self-prepared cellulose triphenylcarbamate chiral stationary phase are performed. The mobile phase is n-hexane modified by isopropanol as a polar modifier. Nine chiral pesticides (benalaxyl, vinclozolin, diclofop-methyl, tebuconazole, quizalofop-ethyl, hexaconazole, lactofen, isocarbophos, and paclobutrazol) show enantioselectivity on the chiral stationary phase. An online circular dichrorism detector is used for identifying the pesticide enantiomers. The influences of the volume content of isopropanol and column temperature on the separations are investigated. The thermodynamic parameters related to the chiral distinguish mechanisms are also calculated.  相似文献   

12.
The enantiomeric separations of three pesticides fipronil (asymmetric nitrogen), isocarbophos (asymmetric phosphorus) and carfentrazone-ethyl (asymmetric carbon) were studied on cellulose-tri(3,5-dimethylphenylcarbamate) chiral stationary phase using high-performance liquid chromatography under normal phase. The mobile phase was n-hexane with alcohols including ethanol, n-propanol, iso-propanol, n-butanol and iso-butanol as polar modifiers. The flow rate was 1.0 mL/min with UV detection at 280, 225 and 230 nm for fipronil, isocarbophos and carfentrazone-ethyl respectively. The influence of the modifiers and their volume content and temperature from 0 to 50 degrees C on the separations was investigated. The chiral stationary phase showed excellent stereoselectivity for the two enantiomers of fipronil and isocarbophos and certain chiral recognition for carfentrazone-ethyl. Iso-propanol was more suitable for the chiral separation of isocarbophos and carfentrazone-ethyl, and iso-butanol was better for fipronil. The resolutions increased with the decreasing modifier content and temperature for all the three chiral pesticides.  相似文献   

13.
The peak compression effect has been applied to improve quantification limits in chiral capillary electrochromatography (CEC). A stationary phase based on the chiral selector vancomycin (Chirobiotic V) was used for separations of the enantiomers of mianserin. By adding solvents with a low dielectric constant, e.g. 2-propanol or tetrahydrofuran, to the sample solution, peak compression could be induced. The plate numbers for the minor enantiomer increased from approximately 100,000 to 1.4-1.6 million plates/m, when the composition of the mobile phase was adjusted so that the analyte eluted within either one of two system zones originating from the sample solution. A 10-fold improvement in the quantification limit for the minor enantiomer was obtained compared to elution under non-focused conditions.  相似文献   

14.
Analytical high-performance liquid chromatographic separations of the individual enantiomers of five polychlorinated compounds were obtained on polysaccharide stereoselective HPLC columns. The enantiomers of the pesticides trans-chlordane, cis-chlordane and heptachlor were separated on CHIRALCEL OD using a hexane mobile phase. The enantiomers of the heptachlor metabolite, heptachlor epoxide, were separated on CHIRALPAK AD using a methanol mobile phase. The enantiomers of alpha-hexachlorocyclohexane (alpha-HCH), were separated on CHIRALCEL OJ using a hexane/2-propanol mobile phase. Similar chromatographic conditions using preparative columns were used to isolate approximately 250 mg of each of the individual enantiomers. The purified individual enantiomers have been submitted for testing of their endocrine disruptor (ED) activity.  相似文献   

15.
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on an octylsiloxane-bonded (Kinetex C8) and diisobutyloctadecylsiloxane-bonded (Kinetex XB-C18) superficially porous silica stationary phases for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation-exchange) are important for the retention of weak bases with acetonitrile–water but not for methanol–water mobile phases. Compared with an octadecylsiloxane-bonded silica stationary phase (Kinetex C18) retention is reduced due to a less favorable phase ratio for both the octylsiloxane-bonded and diisobutyloctadecylsiloxane-bonded silica stationary phases while selectivity differences are small and solvent dependent. Selectivity differences for neutral compounds are larger for methanol–water but significantly suppressed for acetonitrile–water mobile phases. The selectivity differences arise from small changes in all system constants with solute size and hydrogen-bond basicity being the most important due to their dominant contribution to the retention mechanism. Exchanging the octadecylsiloxane-bonded silica column for either the octylsiloxane-bonded or diisobutyloctadecylsiloxane-bonded silica column affords little scope for extending the selectivity space and is restricted to fine tuning of separations, and in some cases, to obtain faster separations due to a more favorable phase ratio. For weak bases larger differences in relative retention are expected with acetonitrile–water mobile phases on account of the additional cation exchange interactions possible that are absent for the octadecylsiloxane-bonded silica stationary phase.  相似文献   

16.
A novel silica monolithic stationary phase functionalized with 3-(2-aminoethylamino)propyl ligands for pressurized CEC has been presented. The monolithic capillary columns were prepared by a sol-gel process in 75 microm id fused-silica capillaries and followed by a chemical modification. The diamino groups on the surface of the stationary phase are meant to generate the chromatographic surface and a substantial anodic EOF as well as to provide electrostatic interaction sites for charged solutes. The electrochromatographic characterization and column performance were evaluated by a variety of neutral and charged solutes. It was observed that the anodic EOF for the diamine-bonded monolith was greatly affected by the reaction time with 3-(2-aminoethylamino)propyltrimethoxysilane and the PEG amount in the sol-gel reaction mixture in addition to the mobile phase conditions. The monolithic stationary phase exhibited hydrophilic interaction chromatographic behavior toward neutral solutes. Good separations of various solutes including phenols, nucleic acid bases, nucleosides and nucleotides were achieved under different experimental conditions. Fast and efficient separations were obtained with high plate counts reaching more than 130,000 plates/m.  相似文献   

17.
N. Wu  Q. Tang  Y. Shen  M. L. Lee 《Chromatographia》1999,49(7-8):431-435
Summary In this paper, practical considerations of column efficiency, separation speed, thermal stability, and column polarity of capillary columns packed with polybutadiene-coated zirconia were investigated under solvating gas chromatography (SGC) conditions using carbon dioxide as mobile phase. When compared with results obtained from conventional porous octadecyl obtained from conventional porous octadecyl bonded silica (ODS) particles, PBD-zirconia particles produced greater change in mobile phase linear velocity with pressure than conventional ODS particles under the same conditions. The maximum plate number per second (Nt) obtained with a 30 cm PBD-zirconia column was approximately 1.5 times higher than that obtained with an ODS column at 100 °C. Therefore, the PBD-zirconia phase is more suitable for fast separations than conventional ODS particles in SGC. Maximum plate numbers per meter of 76,900 and 63,300 were obtained using a 57 cm×250 μm i.d. fused silica capillary column packed with 3 μm PBD-zirconia at 50 °C and 100 °C, respectively. The PBD-zirconia phase was stable at temperatures up to 320 °C under SGC conditions using carbon dioxide as mobile phase. Polarizable aromatic compounds and low molecular weight ketones and aldehydes were eluted with symmetrical peaks from a 10 cm column packed with 3 μm PBD-zirconia. Zirconia phases with greater inertness are required for the analysis of more polar compounds by SGC.  相似文献   

18.
The influence of pressure drop on retention, selectivity, plate height and resolution was investigated systematically in packed supercritical fluid chromatography (SFC) using pure carbon dioxide as the mobile phase. Numerical methods developed previously which enabled the prediction of pressure gradients, diffusivities, capacity factors, plate heights and resolutions along the length of the column were used for the model calculations. The effects of inlet pressure and supercritical fluid flow rate on selectivity and resolution are studied. In packed column SFC with pure carbon dioxide as the mobile phase, the pressure drop can have a significant effect on resolution. The flow rate is shown to have a larger effect than generally realized. The calculated data are shown to be in good agreement with the experimental results. Finally, the variation of the chromatographic parameters along a 5.5 meter long model SFC column is illustrated. The possibilities and limitations of using long packed columns in SFC are discussed. It is demonstrated that long columns with large plate numbers do not necessarily yield better separations.  相似文献   

19.
In order to obtain a selection of optimal chromatographic columns for the separation of chlorotriazine pesticides in packed column supercritical fluid chromatography (pSFC), a multi-criteria approach is applied. For this purpose, prediction of the separations is carried out, based on quantitative structure–retention relationships, then Derringer's desirability function is proposed to determine the stationary phase that will result in the most desirable separation. The best SFC separation obtained was then optimized using a mobile phase gradient. Besides, the accuracy of the solvation parameter model as SFC retention predictive model is assessed.  相似文献   

20.
Dias NC  Nawas MI  Poole CF 《The Analyst》2003,128(5):427-433
The solvation parameter model is used to identify suitable chromatographic models for estimating the octanol-water partition coefficient for neutral compounds of varied structure by reversed-phase liquid chromatography. The stationary phase Supelcosil LC-ABZ with methanol-water mobile phases affords a series of suitable correlation models for estimating the octanol-water partition coefficient (log KOW) under isocratic and gradient elution conditions. Isocratic separations with mobile phase compositions containing from about 25 to 40% (v/v) methanol provide the most accurate results for log KOW values in the range -0.1 to 4.0. Gradient separations programmed from 5 to 100% (v/v) methanol are suitable for faster separations of compounds with large log KOW values. The standard error in the estimate for the regression models of the predicted log KOW values against literature values are 0.135 log units for the 30% (v/v) methanol-water isocratic system and 0.263 log units for the methanol-water gradient system. Isocratic retention factors predicted from two gradient separations with gradient times of 15 and 45 min afford a poorer fit for the correlation models between log KOW and the estimated retention factors than that of either the above isocratic and gradient models. Plots of the retention factor (log k) as a function of mobile phase composition are generally non-linear. Values of log kw obtained by non-linear extrapolation to a volume fraction of 0% (v/v) methanol do not afford a useful model for estimating log KOW.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号