首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
A combination of solid phase micro‐extraction (SPME) with attenuated total reflection (ATR) infrared spectrometry provides a fast and sensitive way to detect organic compounds in aqueous solutions. It is especially useful for detection of chlorinated organic compounds in environmental samples. Currently, analyses of organic compounds in aqueous solutions are limited to low‐polarity compounds by the SPME/ATR‐IR sensing method. This limitation was mainly caused by the low polarity nature of the SPME phase. To increase the capability of this method to detect more polar compounds and also to increase the sensitivity in detection of organic compounds, the principle of “like‐dissolve‐like” was used to design a specific SPME phase for a certain class of chlorinated compounds. To demonstrate this concept, chlorinated phenols were used as probe molecules and polyvinyl chloride was chemically modified with phenol, ‐naphthol and ‐naphthol to provide SPME phases with a similar chemical structure to chlorinated phenols. These polymers were used as SPME phases and their performance were compared with the commonly used SPME phases (i.e., polystyrene and polyisobutylene). Results indicated that naphthols attached to PVCs provided much lower compactness, which allows fast speed in absorption of phenols. Meanwhile, due to the structural similarity between naphthols attached to PVCs and phenols, much higher partition coefficients were found for these chemically modified PVCs than conventionally used polymers. To further increase the sensitivity for analysis of chlorinated phenols, the common influencing factors, such as pH values and salt effect were also investigated. Apparently, pH values of the solutions did not influence the structure of the modified PVCs significantly. In absorption of chlorinated phenols in aqueous solutions with different pH values, the observed IR signals were decreased greatly in pH higher than 6 due to the charged form of chlorinated phenols that were presented. Results of the salt effect indicated that three times stronger of IR signals can be obtained if 20% (w/vol) of NaCl was added.  相似文献   

2.
Fast determination of phenols in contaminated soils   总被引:3,自引:0,他引:3  
An extraction method for the determination of phenols in contaminated soils, based on the application of solid-phase microextraction (SPME) coupled with GC-flame ionization detection analysis, was developed and tested. This method was developed using a natural soil spiked with phenol to a concentration level typical of an acute contamination event that can occur in an industrial site. The effects of the extraction parameters (pH, extraction time and salt concentration) on the extraction efficiency were studied and the method was then applied to determine the pollutant concentration at the beginning and during the biological treatment of a soil, contaminated with phenol and 3-chlorophenol, respectively. The SPME results were validated by comparison with those obtained with an US Environmental Protection Agency certified extraction method. The SPME method was also successfully applied to the determination of the adsorption behavior of 3-chlorophenol on a natural clay soil and was shown to be suitable for different matrices and phenolic compounds. Application of SPME technique results in a sharp reduction of the extraction times with negligible solvent consumption.  相似文献   

3.
An aniline-based polymer was electrochemically prepared and applied as a new fiber coating for solid phase microextraction (SPME) of some priority phenols from water samples. The polyaniline (PANI) film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The efficiency of new coating was investigated using a laboratory-made SPME device and gas chromatography with flame ionization detection for the extraction of some phenols from the headspace of aqueous samples. The scanning electron microscopy (SEM) images showed the homogeneity and the porous surface structure of the film. The results obtained proved the ability of this polymer as a suitable SPME fiber coating for trapping the selected phenols. Influential parameters affecting the extraction process were optimized and an extraction time of 50 min at 50 °C gave maximum efficiency, when the aqueous sample was saturated with NaCl and adjusted at pH 2. This new coating can be prepared easily in a reproducible manner and it is rather inexpensive and stable against most of organic solvents. The PANI thickness can be precisely controlled by the number of CV cycles. At the optimum conditions, the R.S.D. for a double distilled water spiked with phenol and chlorophenols at ppb level were 4.8-17% (n = 3) and detection limits for the studied compounds were between 0.69 and 3.7 ng ml−1, except for phenol and 4-chlorophenol. The optimized method was successfully applied to some real-life water samples.  相似文献   

4.
Helaleh MI  Fujii S  Korenaga T 《Talanta》2001,54(6):1039-1047
In solid phase micro-extraction (SPME), the analyte is partitioned between the coating and the sample and then desorption of the concentrated analyte is followed by GC-MS, where the analytes are thermally desorbed and subsequently separated on the column and quantified by the detector. The SPME method preserves all the advantages, such as simplicity, low cost, on site sampling and does not require solvents. Poly(acrylate) coating fibers have been developed for the extraction of phenols (such as 4-tert-butylphenol, 2,4-dichlorophenol, 4-n-pentylphenol, 4-n-hexylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-n-nonylphenol, 4-n-octylphenol, pentachlorophenol and bisphenol A) in different water samples. The precision of the HS-SPME method ranges from 3–12% RSDs, depending on the compounds analyzed. More accurate results were obtained by HS-SPME with acidification and salting out, where the fiber is located above the liquid sample. The extraction period was 60 min, followed by desorption for 5 min at 300°C. After the analytes were completely desorbed, 1 μl of bis(trimethylsilyl)trifluoroacetamide (BSTFA) was injected by ordinary GC-MS injection. The trimethylsilylate peaks were improved significantly compared with free phenol peaks. The addition of salt (saturated sodium chloride) and acidification by hydrochloric acid (pH 2.0) were found to be very important for enhancing the partitioning of the polar phenols into the polymer coating and preventing ionization of the analytes. The method is capable of limits of detection of subparts per billion of the total phenols extracted from environmental water samples.  相似文献   

5.
SPME-GC联用测定环境水样中的酚类化合物   总被引:1,自引:0,他引:1  
建立了固相微萃取与气相色谱联用技术测定环境水样中酚类化合物的方法. 探讨了pH、离子强度、萃取头类型、萃取时间以及解析时间等条件对酚类化合物萃取量的影响, 优化了GC仪器条件. 在优化的条件下, 酚类化合物的响应值与浓度有良好的线性关系, 线性范围为0.20~200 μg/L, 检出限在0.019~0.10 μg/L之间, 相对标准偏差(RSD, n=5)为4.4%~11%, 水样平均加标回收率为92.2%~101.9%, 所建立的方法可测定环境水样中的酚类化合物.  相似文献   

6.
The chromatographic characteristics of 58 phenols on Rexyn 102 and Dowex 50-X4 thin layers in both the acidic and sodium salt forms have been studied, using elution with water, water-alcohol mixtures and aqueous salt solutions at different pH values. The influence of the percentage of alcohol, the pH and the ionic strength on the chromatographic behaviour of these phenols was investigated. The validity of the relationships among the RF values, the pH of the eluent and the pKa of the phenol has been verified on Dowex 50-X4 (Na+) thin layers. It has been shown that from the RFac, RFalk and pKa values of the different phenols, it is possible to predict their behaviour over the whole pH range and therefore to select the best conditions for their chromatographic separation.  相似文献   

7.
Veltol® (2-methyl 3-hydroxy 4-pyrone) and Veltol-Plus® (2-ethyl 3-hydroxy 4-pyrone) are patented flavor ingredients in food products. Only Veltol® can occur naturally, but both Veltol® and Veltol-Plus® are often added to food products. In order to monitor the use of these compounds in food products, lower detection limits were needed. The Solid Phase Microextraction (SPME) technique for beverages and SPME coupled with Microwave Assisted Extraction (MAE) for solid food samples were studied. The influence of the pH, salt content, SPME adsorption time, GC inlet conditions, and the conditioning of the SPME fiber were investigated. Different food products were tested including coffee, beverages, chewing gums and potato chips. The coupled MAE and SPME shows good results for solid food samples. The reproducibility of the technique was less than 13%RSD and the detection limit was 10 ppb for Veltol® and 2 ppb for Veltol-Plus® using the SIM mode in GC/MS. The technique also shows good selectivity for the target compounds investigated in different food samples.  相似文献   

8.
Water-soluble polymers (poly-N-vinylpyrrolidone, poly-N-vinylcaprolactam, polyethylene glycol) were used for the first time for extraction of phenols from aqueous solutions. The influence exerted by pH of the aqueous solution and kind of the polymer on the degree of recovery of phenol and some of its methyl and nitro derivatives was elucidated. The correlation between the structure and extraction characteristics of phenols was interpreted.  相似文献   

9.
魏超  卢珩俊  陈梅兰  朱岩 《色谱》2011,29(1):54-58
建立了中空纤维液-液-液三相微萃取-高效液相色谱法测定水中4种酚类化合物的方法.实验系统地优化了影响萃取效率的因素(包括有机溶剂种类、接收相浓度、分散相pH值、加盐量、转速及萃取时间).得到的最佳萃取条件为:萃取剂为正辛醇,接收相NaOH溶液的浓度为0.09 mol/L,分散相的pH为4,萃取时间为40 min,搅拌速...  相似文献   

10.
The establishment of geographic origin chemical biomarkers for the marine salt might represent an important improvement to its valorisation. Volatile compounds of marine salt, although never studied, are potential candidates. Thus, the purpose of this work was the development of a headspace solid phase microextraction (SPME) combined with gas chromatography-quadrupole mass spectrometry (HS-SPME/GC-qMS) methodology to study the volatile composition of marine salt. A 65 μm carbowax/divinylbenzene SPME coating fibre was used. Three SPME parameters were optimised: extraction temperature, sample quantity, and presentation mode. An extraction temperature of 60 °C and 16 g of marine salt in a 120 mL glass vial were selected. The study of the effect of sample presentation mode showed that the analysis of an aqueous solution saturated with marine salt allowed higher extraction efficiency than the direct analysis of salt crystals. The dissolution of the salt in water and the consequent effect of salting-out promote the release of the volatile compounds to the headspace, enhancing the sensitivity of SPME for the marine salt volatiles. The optimised methodology was applied to real matrices of marine salt from different geographical origins (Portugal, France, and Cape Verde). The marine salt samples contain ca. 40 volatile compounds, distributed by the chemical groups of hydrocarbons, alcohols, phenols, aldehydes, ketones, esters, terpenoids, and norisoprenoids. These compounds seem to arise from three main sources: algae, surrounding bacterial community, and environment pollution. Since these volatile compounds can provide information about the geographic origin and saltpans environment, this study shows that they can be used as chemical biomarkers of marine salt.  相似文献   

11.
Zhu F  Guo J  Zeng F  Fu R  Wu D  Luan T  Tong Y  Lu T  Ouyang G 《Journal of chromatography. A》2010,1217(50):7848-7854
Two kinds of porous carbon materials, including carbon aerogels (CAs), wormhole-like mesoporous carbons (WMCs), were synthesized and used as the coatings of solid-phase microextraction (SPME) fibers. By using stainless steel wire as the supporting core, six types of fibers were prepared with sol-gel method, direct coating method and direct coating plus sol-gel method. Headspace SPME experiments indicated that the extraction efficiencies of the CA fibers are better than those of the WMC fibers, although the surface area of WMCs is much higher than that of CAs. The sol-gel-CA fiber (CA-A) exhibited excellent extraction properties for non-polar compounds (BTEX, benzene, toluene, ethylbenzene, o-xylene), while direct-coated CA fiber (CA-B) presented the best performance in extracting polar compounds (phenols). The two CA fibers showed wide linear ranges, low detection limits (0.008-0.047μgL(-1) for BTEX, 0.15-5.7μgL(-1) for phenols) and good repeatabilities (RSDs less than 4.6% for BTEX, and less than 9.5% for phenols) and satisfying reproducibilities between fibers (RSDs less than 5.2% for BTEX, and less than 9.9% for phenols). These fibers were successfully used for the analysis of water samples from the Pearl River, which demonstrated the applicability of the home-made CA fibers.  相似文献   

12.
《Analytical letters》2012,45(15):3083-3110
ABSTRACT

A solid phase extraction (SPE) system has been modified with cationic surfactants and evaluated for extraction and preconcentration of trace phenolic compounds contaminants in water at low ppb concentrations. Cationic surfactants such as cetyl trimethyl ammonium bromide (CTAB) has been steadily adsorbed on the surface of C-18 bonded silica, and the ionized functional group of the surfactant can then act as an ion–exchange site to attract the ionized phenolic compounds from water samples. The method includes enrichment of the phenolic compounds by the surfactant-loaded solid phase extraction system, followed by elution of the analyte with methylene chloride and derivatization of the phenolic compounds with acetic anhydride. Thirty-two phenolic analytes were identified and quantitatively determined by this method; identification and quantification of the compounds is performed with GC/FID using 2-bromophenol as internal standard. SPME analysis with this method was linear over 3-6 orders of magnitude, with linear correlation coefficient (R2) greater than 0.96. Experimentally determined FID detection limits ranged from ~30 ppt for methyl-substituted phenols to ~0.1ppb for phenol and chloro-substituted phenols. We tested the influence of sample pH, the loading amount of surfactant on the solid phase, and the volume and matrixes of the sample were studied. Absolute recoveries from pure water spiked with 0.2 ppb phenolic compounds were 96 – 103%. The method has been applied to analysis of various natural waters, including ground water, lake water, seawater, and wastewater. Recoveries from ground water, lake water, seawater, and wastewater were 92 – 106%, 75 – 93%, 87 – 103%, 86 – 99%, respectively. Therefore, the new technique proved to be an excellent tool for trace enrichments of phenolic compounds at low ppb concentration of these analytes, from different natural water samples.  相似文献   

13.
基于氯过氧化物酶(CPO)催化氧化苯酚衍生物单体,建立了一个聚酚的绿色合成体系.以对苯基苯酚、对甲基苯酚、4-乙基苯酚、对羟基肉桂酸、对异丙基苯酚和邻甲基苯酚等6种底物为考察对象,以聚合物的产率、聚合度及热稳定性为评价指标,研究了体系中引入离子液体(ILs)或季铵盐(QAS)以及底物结构和反应微环境等对聚合反应和聚合物性质的影响.结果表明,引入少量咪唑类ILs或QAS可有效提高产物收率,其中ILs/QAS的阳离子基团越大和疏水链越短,越有利于酶催化聚合反应的进行;而ILs/QAS添加量的影响则呈现"钟罩"型规律.同时,苯酚对位取代远比邻位取代有利于聚合反应进行;而对位取代基中烷基类给电子基团比芳香基取代更有优势,所得聚合物的聚合度和热稳定性相对增大,但随着取代基团的增大,其空间位阻不利于聚合物产率的提高;反应体系的p H应控制在弱酸性至近中性,以避免竞争性的副反应的发生;而氧化剂H_2O_2则需要采用间歇式加入以抑制瞬时过浓导致CPO活性中心卟啉环的氧化损伤.基于CPO的活性中心结构分析了聚合机理.  相似文献   

14.
It was reported that3-methylbutanal was an important volatile compound in dry-cured ham products1-3.It has been associated with nutty,cheesy and salty notes in Parma ham4and correlated with the aged flavor of hams5.It is also maybe one of the reasons for …  相似文献   

15.
姚桂燕  观文娜  许峰  王华  关亚风 《色谱》2008,26(5):590-594
应用自制的聚醚砜酮(PPESK,30 μm)涂层纤维,采用顶空固相微萃取-气相色谱法测定水中痕量的酚类化合物。优化了固相微萃取温度、萃取时间、pH值和离子强度。方法的检出限为0.003~0.041 μg/L,相对标准偏差低于16%(n=5)。将PPESK涂层纤维与商品化的聚丙烯酸酯涂层纤维对比,结果表明PPESK萃取酚类化合物有较高的萃取富集倍数。用所制备的PPESK萃取头分析自来水、海水等实际水样,20 μg/L添加水平下的回收率分别为100.5%~111.8%和94.8%~117.3%。  相似文献   

16.
A solid phase microextraction-gas chromatography (SPME-GC) method was developed to trace natural sources of dissolved organic carbon (DOC) in river systems. The effects of extraction time, temperature, salt concentration, rate of stirring, and silanisation of sampling container were examined. The optimum extraction conditions using a polydimethylsiloxane (PDMS) SPME fibre were found to be extraction for 15 min at 40 °C, pH 2, from a saturated NaCl matrix with rapid stirring in a non-silanised vial. The method gave good results for a series of six compounds representative of those likely to be present in dissolved organic carbon leached from River Red Gum leaves—cineole, terpineol, thymol, myristic acid, methyl palmitate and methyl stearate. Artificial dissolved organic carbon solutions prepared from River Red Gum leaf leachate were also examined and the effects of filtering and storage on the filtrate were noted. The method was demonstrated to have potential to track the leachate in aquatic environment, indicated by the large number of compounds extracted from leachate solutions, and the broad linear working ranges of extracted compounds.  相似文献   

17.
Wu J  Lord H  Pawliszyn J 《Talanta》2001,54(4):655-672
A simple and sensitive method for the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine and hair samples was developed by coupling automated in-tube solid phase microextraction (SPME) to high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ES-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ES-MS detection were investigated. ES-MS detection conditions were studied by flow injection analysis (FIA) with direct liquid injection. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, including capillary stationary phases and sample pH. For the compounds studied, a custom-made polypyrrole (PPY) coated capillary showed superior extraction efficiency as compared to commercial capillaries. Therefore, the PPY coated capillary was selected for in-tube SPME in this study. The calibration curves of stimulants were linear in the range from 0.1 to 100 ng ml(-1) with detection limits (S/N=3) of 8-56 ng l(-1). This method was successfully applied to the analysis of the stimulants in spiked human urine and hair samples.  相似文献   

18.
A novel poly(dimethylsiloxane)/beta-cyclodextrin (PDMS/beta-CD) coating was prepared for solid-phase microextraction (SPME). The PDMS/beta-CD coating proved to have a porous structure, providing high surface areas and allowing for high extraction efficiency. The coating had a high thermal stability (340 degrees C) and a long lifetime due to its chemical binding to the fiber surface. Polar phenols and amines were used to evaluate the character of the coating fiber by headspace (HS) extraction and thermal desorption, followed by GC-FID analysis. Parameters that affected the extraction process were investigated; these include extraction time and temperature, desorption time, pH, and ionic strength of the solution. For phenols, the range of linearity of the method was 4-500 microg/L and the LOD was 1.3-2.1 microg/L. For amines, the range of linearity was 1-1000 microg/L and the LOD was 1.2-2.8 microg/L. The presence of beta-CD not only increases the thermal stability of the fiber coating, but also enhances its selectivity. Compared with commercially available SPME fibers, the new phases show better selectivity and sensitivity towards polar compounds.  相似文献   

19.
The extraction of two methylated anilines and three chlorinated phenols by solid-phase microextraction (SPME) fibers coated with polyacrylate was investigated as a function of pH. Only the neutral species of the acids and bases partitioned into the polymer. Extraction kinetics were accelerated for the hydrophobic phenols at pH values around their acidity constant. This is presumably due to a reconstitution of the neutral species in the unstirred aqueous layer adjacent to the polymer surface by the charged species through the fast acid-base equilibrium. Although the charged species is not taken up into the polymer, liposome/water distribution ratios could be measured up to a pH value, where 99% of the compounds were present as charged species. The partition coefficients of the neutral and charged species were extrapolated from the pH profiles of the liposome/water distribution ratios. The resulting values were slightly lower than those measured with equilibrium dialysis. The discrepancies are discussed with respect to differences in the experimental conditions and the possibility of matrix effects during SPME measurements.  相似文献   

20.
Jiangang He  Peng Dou 《Talanta》2009,79(3):746-3288
A new format of solid phase microextraction (SPME), boronate affinity SPME, was proposed for the first time for covalent extraction of cis-diol containing biomolecules. This new SPME format is based on the reversible complex formation between boronic acids and 1,2- and 1,3-cis-diols. The complex formation and dissociation can be facilely controlled by changing pH. An extracting phase of poly-3-aminophenylboronate (polyAPBA) electrochemically deposited on a metal wire was employed to demonstrate the concept of this new methodology. Catechol and riboflavin were used as the test analytes, and the SPME extraction was combined off-line with high-performance liquid chromatographic (HPLC) separation followed by UV absorbance or fluorescence detection. Fundamental aspects, such as selectivity, extraction/desorption equilibrium, linearity, effect of competing compounds, reproducibility and life-time, were first investigated. Then the developed method was applied to beer samples since the content of riboflavin plays an important role in the flavor stability of beverages. Excellent performance of the SPME fibers was observed for both standard and real samples. Particularly, the expected excellent features of the polyAPBA extracting phase were experimentally verified, which include specific selectivity, eliminated matrix effect and manipulable capture/release. The new methodology of SPME can be a promising tool since a lot of 1,2- and 1,3-cis-diol-containing compounds are of great biological importance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号