首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The application of perfluorotributylamine (PFTBA) ions/analyte molecule reaction ionization for the selective determination of tobacco pyridine alkaloids by ion trap mass spectrometry (IT-MS) is reported. The main three PFTBA ions (CF(3)(+), C(3)F(5)(+), and C(5)F(10)N(+)) are generated in the external source and then introduced into ion trap for reaction with analytes. Because the existence of the tertiary nitrogen atom in the pyridine makes it possible for PFTBA ions to react smoothly with pyridine and forms adduct ions, pyridine alkaloids in tobacco were selectively ionized and formed quasi-molecular ion [M + H](+)and adduct ions, including [M + 69](+), [M + 131](+), and [M + 264](+), in IT-MS. These ions had distinct abundances and were regarded as the diagnostic ions of each tobacco pyridine alkaloid for quantitative analysis in selected-ion monitoring mode. Results show that the limit of detection is 0.2 microg/mL, and the relative standard deviations for the seven alkaloids are in the range of 0.71% to 6.8%, and good recovery of 95.6% and 97.2%. The proposed method provides substantially greater selectivity and sensitivity compared with the conventional approach and offers an alternative approach for analysis of tobacco alkaloids.  相似文献   

2.
Tsai JL  Wu WS  Lee HH 《Electrophoresis》2000,21(8):1580-1586
A rapid, sensitive method for the determination of morphine and amphetamine was developed using capillary zone electrophoresis coupled with electrospray interface (ESI), ion-trap tandem mass spectrometry (CE-ESI-MS2). Morphine and amphetamine were separated in 20 mM ammonium acetate buffer (pH 6.6) and detected by ion-trap mass detector in different analytical time segments (0-6.25 min for amphetamine and 6.25-12.0 min for morphine) in which the tune file for each compound was used separately. Molecular ions of morphine (m/z 286) and amphetamine (m/z 136) were detected at 5.77 and 6.83 min, respectively, while product ions of MS2 for each compound (m/z 229, 201 for morphine and m/z 119 for amphetamine) were detected almost exactly at the same time with their parent compounds. The limits of detection (LOD) for MS2 determination were 30 and 50 ng/mL for amphetamine and morphine, respectively, with an S/N ratio of 3. For more sensitive detection of morphine, the sample was injected for a longer time (i.e., 80 s) and hydrodynamically transported into a CE capillary for MS detection. Morphine and its product ion appear at 0.36 and 0.39 min on the ion chromatogram, respectively, with a five-fold increase of detection sensitivity (LOD, 10 ng/mL). The CE-MS system thus established was further applied for forensic urine samples screened as morphine-positive by fluorescence polarization immunoassay (FPIA). These results indicated the feasibility of CE-ESI-MS2 for confirmative testing of morphine in urine sample.  相似文献   

3.
A procedure for the determination of very low polycyclic aromatic hydrocarbons (PAHs) concentrations in sediment samples has been developed by gas chromatography-quadrupole ion trap mass spectrometry (GC-QIT MS) after extraction with dichloromethane and purification by using silica gel cleanup. Identification and quantification of analytes were based on the selected ion storage (SIS) strategy using deuterated PAHs as internal standards. In order to search out the main factors affecting the SIS mass spectrometry efficiency, four MS parameters, including target total ion count (TTIC), waveform amplitude (WA), transfer line (XLT) and ion trap temperatures (ITT) were subjected to a complete multifactorial design. The most relevant parameters obtained (TTIC and WA) were optimized by a rotatable and orthogonal composite design. Optimum values for these parameters were selected for the development of the method involving PAH determination in sediment samples. The optimized method exhibited a range of 111-760% higher signal-to-noise (S/N) ratios for PAHs in comparison with the method operated by the default conditions, demonstrating that the multifactorial optimization contributed to substantially improve the sensitivity of the GC-QIT MS determination. The accuracy of the method was verified by analyzing NWRI EC-3 certified reference material (Lake Ontario sediment). The selectivity, sensitivity (limits of quantification were in the range of 0.02-11.0 ng g(-1)), accuracy (recoveries >or=77%) and precision (RSD相似文献   

4.
We present a detailed study of the energies of the ions stored in a quadrupole ion trap mass spectrometer (QITMS). Previous studies have shown that the rate constant, k, for the charge exchange reaction Ar+ N+ 2 →, N+ 2+Ar increases with increasing ion-molecule center-of-mass kinetic energy (K.E.cm). Thus, we have determined k for this chemical “thermometer” reaction at a variety of Ar and N2 pressures and have assigned K.E.cm values as a function of the q2 of the Ar+ ion both with and without He buffer gas present in the trap. The K.E.cm energies are found to lie within the range 0.11–0.34 eV over the variety of experimental conditions investigated. Quantitative “cooling” effects due to the presence of He buffer gas are reported, as are increases in K.E.cm due to an increase in the q2 of the Ar+ ion. “Effective” temperatures of the Ar+ ions in He buffer are determined based on a Maxwell-Boltzmann distribution of ion energies. The resulting temperatures are found to lie within the range ≈ 1700–3300 K. We have also examined the K.E.cm, values arising from the chemical thermometer reaction of O+ 2 with CH4, as previous assignments of effective ion temperatures based on this reaction have been called into question.  相似文献   

5.
The fullerenes C60 and C70 can be ionized by desorption from a liquid matrix upon bombardment by Cs+ ions of 7 keV kinetic energy. The resulting radical cations, when activated in the ion trap by collisions with Xe target, in the presence of helium, undergo extensive dissociation by loss of multiple C2 units. Large internal energies are deposited into these molecular ions and the dissociation efficiency is in excess of 60%.  相似文献   

6.
随着质谱技术的不断发展,对超高质量颗粒物质的分析已经成为质谱领域研究的一个重要方向.离子阱颗粒质谱(particle ion trap mass spectrometry)作为用于完整颗粒质量分析的有利工具,拓展了质谱技术在巨大颗粒物质量分析中的应用范围.本文对离子阱颗粒质谱仪器的研究进展及其在各个领域的应用进行了综述,并展望了离子阱颗粒质谱未来的发展趋势.  相似文献   

7.
Plasmatic chlorophacinone is commonly measured with liquid chromatographic assay, which convenient but lacks sensitivity and selectivity and usually requires ion pair reagents to reduce the chromatographic tailed peak. In this paper, a novel method using eluent generator reagent‐free ion chromatography coupled with electrospray ionization ion trap mass spectrometric detection for the determination of chlorophacinone in plasma has been developed. After samples were extracted with 10% (v/v) methanol in acetonitrile and cleaned by solid‐phase extraction, chromatographic separation was performed on an IonPac® AS11 analytical column (250 × 4.0 mm) using 40.0 mmol/L KOH containing 10% (v/v) methanol as organic modifier. Quantification was performed by negative electrospray ionization in multiple reaction monitoring mode. The transition m/z 373 → 201 was for the quantification ion; the transitions m/z 373 → 172 and m/z 373 → 145, as well as the isotope ions m/z 375 and m/z 203, were for the qualitative ions. All the method parameters were validated. It was confirmed that this method can be used in clinical diagnosis and forensic toxicology. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
The effects of different experimental parameters on arginine electrospray ionization have been investigated with response surface modelling design. This chemometric technique allows a study of the effects of selected experimental variables and their interactions on the response of an experiment by performing a limited number of analyses. Six variables were studied: methanol content in the liquid phase, formic acid concentration, electrospray voltage, orifice voltage, mobile phase flow rate, and sheath gas flow rate. Signal abundance and signal-to-noise ratio of the protonated molecule and the protonated dimer were measured from the electrospray mass spectra and these four responses were tested by the design. The factor that exhibits the greatest influence on MH+ abundance is shown to be the liquid flow rate whereas the formation of protonated dimer is mainly controlled by the percentage of methanol in the mobile phase. A strong synergic effect of methanol content and formic acid concentration in the liquid has also been demonstrated in the study of noise level. Moreover, the capabilities of the multicriteria optimization method have been demonstrated through a successful prediction of a set of optimal experimental conditions.  相似文献   

9.
The early stage products of the Maillard reaction of egg white lysozyme with D-glucose were studied. Incubation with D-glucose at 50 degrees C for 20 days caused reaction on the Lys and Arg residues of lysozyme as follows: all of the six Lys residues and 10 of the 11 Arg residues in lysozyme reacted with D-glucose; Arg 61 did not react with D-glucose. The Lys residues reacted with D-glucose with 1 mol of dehydration per mole of residue, and the Arg residues reacted with 2 mol of dehydration per mole of residue. The major constituent of the Amadori product with the epsilon-amino group of the Lys residue and the D-glucose was found to be the beta-pyranose form. The structure of the early stage product of the Maillard reaction of a protein with a sugar is the same as that of an amino acid with a sugar.  相似文献   

10.
This paper describes the determination and quantitation of hexabromocyclododecane (HBCD) enantiomers by liquid chromatography-quadrupole linear ion trap mass spectrometry (LC-QqLIT-MS). The method is based on the use of a chiral chromatographic column Nucleodex beta-PM (200 mm x 4.0 mm, 5 microm), which allows a good separation between HBCD enantiomers [(+/-)alpha, (+/-)beta and (+/-)gamma] in less than 15 min and the detection is performed by a Q-Trap instrument. Linearity was checked between 0.05 and 25 injected ng. Limits of detection (LODs) were in the range of 0.3-1.5 pg, limits of quantification (LOQs) were between 1 and 6 pg, and both values are lower than those published in the literature applying LC-MS-MS methods. The method was applied to sediment samples collected along the Cinca River, a tributary of the Ebro River (northeast of Spain). Samples were extracted and purified following a pressurized liquid extraction method. LODs of the method were between 0.12 and 5.61 ng/g and LOQs, from 0.38 to 1.87 ng/g. Total HBCD levels in these sediments ranged from not detected to 2660 ng/g dry weight. Enantiomeric fractions (EFs) were calculated and compared with EF obtained from standard injections. It is important to note that calculated EFs were corrected using (2)H(18)-labeled HBCD standards, in order to compensate matrix effect. EFs obtained in sediment samples suggested a higher presence of (+)alpha-HBCD and (+)gamma-HBCD in technical mixture, this suggests that it is not a racemic mixture.  相似文献   

11.
Direct determination of serotonin (5-HT) in gut lavage fluid from patients examined due to various gastrointestinal complaints has been achieved. The method involves addition of 5-methoxytryptamine (5-CH3O-HT) internal standard, centrifugation, filtration and injection of the sample supernatant in a liquid chromatographic system coupled to an ion trap tandem mass detector. Electro-spray in positive mode was used to isolate and fragment the protonated ions [5-HT+H]+ and [5-CH3O-HT+H]+ signals 177 and 191 m/z, respectively. Quantification was carried out by extracting the ion fragment chromatograms at 160 and 174 m/z for 5-HT and 5-CH3O-HT, respectively. The relationship 5-HT/5-CH3O-HT was modelled by using a simultaneous design in order to estimate the optimal amount of internal standard to be added to the samples prior to quantification.  相似文献   

12.
The characterisation of selected indole alkaloids in a quadrupole ion trap mass spectrometer is presented. Fragmentation profiles for tryptamine, 5-hydroxytryptamine (5-HT), N'-methyl 5-hydroxytryptamine (N'-methyl 5-HT), N',N'-dimethyl 5-hydroxytryptamine (bufotenine), N',N',N'-trimethyl 5-hydroxytryptamine (5-HTQ), and N',N'-dimethyl 5-methoxytryptamine (5-MeODMT) are presented with proposed structures given for each product ion observed. Such MS(n) experiments can be used to differentiate the isobaric molecular ions of the compounds 5-HTQ (M(+)) and 5-MeODMT (MH(+)). The quantitative determination of certain indole alkaloids in the skin secretions of the Australian Golden Bell frog, Litoria aurea, by LC/ESI-ion trap MS is also presented. The concentrations of 5-HT, N'-methyl 5-HT and 5-HTQ were found to be 2.68, 0.26 and 0.54 microg per mg of skin secretion, respectively.  相似文献   

13.
The collision-induced decomposition pathways of phenothiazine were studied in detail by ion trap mass spectrometry. With this approach, different amounts of energy can be deposited into the fragment ions, thus favouring particular structures. Different relative abundances in the fragmentation patterns of selected ions are observed, depending on whether they are produced by electron impact or multiple mass spectrometry [(MS)n] methods.  相似文献   

14.
An ion-trap mass spectrometer with a wave board and tandem mass spectrometry software was used to analyze gas chromatographically separated polycyclic aromatic hydrocarbons (PAHs) by using collision-induced dissociation (CID). The nonresonant (multiple collision) mode was used to determine the conditions for CID ionization of 18 PAHs. Unlike in electron impact (EI) analysis, the relative abundances of progeny ions of isomers were statistically different (using Student’s t-test) in CID analysis, thus making isomer identification by CID possible. For comparison, CID and EI were applied to the analysis of used motor oil. CID analysis was shown to be more sensitive than EI analysis of the used motor oil. Precision at the 10-ppb level for EI and CID showed relative standard deviations of 5. 2 and 7. 7%, respectively.  相似文献   

15.
The electrospray ionisation-ion trap mass spectrometry (ESI-MSn) of selected hypnotic drugs, i.e. zopiclone, zolpidem, flunitrazepam and their metabolites have been investigated. Sequential product ion fragmentation experiments (MSn) have been performed in order to elucidate the degradation pathways for the [M+H]+ ions and their predominant fragment ions. These MSn experiments show certain characteristic fragmentations in that functional groups are generally cleaved from the ring systems as neutral molecules such as H2O, CO, CO2, NO2, amines and HF. When an aromatic entity is present in a drug molecule together with a nitrogen-containing saturated ring structure as with zopiclone and its N-desmethyl metabolite fragmentation initially occurs at the latter ring with the former being resistant to fragmentation. The structures of fragment ions proposed for ESI-MSn can be supported by electrospray ionisation-quadrupole time-of-flight mass spectrometry (ESI-QTOF-MS).These molecules can be identified and determined in mixtures at low ng/ml concentrations by the application of liquid chromatography (LC)-ESI-MSn which can be used for their analysis in saliva samples.This paper includes a tabulation of mass losses/signals at low m/z values for these hypnotic drugs and many others in recent publications which will be of value in the characterisation of drug metabolites of unknown structure and also natural product pharmaceuticals isolated from plants, etc.  相似文献   

16.
A method is described for determining 41 insecticide residues in garlic (Allium sativum L.), including organophosphorus, organochlorine, carbamate, and synthetic pyrethroid insecticides. These insecticides were extracted from samples with acetone and dichloromethane, and co-extractives removed using a charcoal/Celite/alumina column. Analysis was performed by gas chromatography with ion trap mass spectrometry in selective ion storage (SIS) mode. Retention times and specific ions (m/z values) were used to confirm insecticides. Recoveries for most insecticides (blank samples spiked at 0.05, 0.2 and 1 microg mL(-1) levels) ranged from 70% to 110%, the coefficient of variation (CV) of the method was <20% for every case, and the limit of detection (LOD), defined in terms of 3 times baseline noise, varied between 0.01 and 0.16 mg kg(-1), depending on the compound.  相似文献   

17.
The fragmentation pathways of three explosive compounds with similar structures, hexanitrostilbene (HNS), cyclotrimethylene trinitramine (RDX), and 2,4,6-trinitrotoluene (TNT), have been investigated by multiple mass spectrometry (MSn, n = 1, 2, 3) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources. The electron capture mechanism for these compounds in negative ion APCI and ESI mode differs from the usual negative ion mechanism, deprotonation or addition of other species. This was shown for HNS and TNT, which both gave a [M]- anion but not a [M-H]- ion in APCI, and the [M]- anion of HNS was observed in ESI. The quantitative analysis of HNS was performed by liquid chromatography (LC)/ESI-MS, and the results obtained by the internal standard (ISTD) method were compared with those from the external standard (ESTD) method, demonstrating that both quantitation approaches are useful, with good sensitivity, reproducibility and linearity, and ESTD is preferable in routine applications.  相似文献   

18.
19.
A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%.  相似文献   

20.
A rapid liquid chromatographic-electrospray ionisation ion trap mass spectrometry (LC-ESI-ITMS) method has been developed for the routine analysis of eight of the most oenologically important biogenic amines in wine without any sample pre-treatment. The method involves addition of heptylamine as an internal standard (IS) and the direct injection of filtered wine samples previously diluted with ultra high purity (UHP) water. The full-scan MS-MS spectra and the identical retention times to those of reference standards were used for unequivocal identification of the analytes. For most amines, the most abundant ions were derived from the loss of an ammonia group, while in the case of spermine and the I.S. the major product ions arose from the loss of 1,3-propyldiamine and the production of adduct with water, respectively. Detection was achieved in positive ionisation with an ion trap mass spectrometer operating in multiple-reaction monitoring (MRM) mode. The method allowed accurate determination of the analytes in the range 0.5-40 ng mL−1. Within-day and between-day relative standard deviation percentages were <8% and <12%, respectively. The overall process was successfully applied to identify and quantify biogenic amines in Rioja red wines. The new method is sensitive, rapid, cheap and less labour intensive.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号