1.
Alendronate is an important representative of bisphosphonates, strongly polar compounds that lack chromophores. With rare exceptions, derivatization of the analytes is necessary for bioanalysis. In this study, a rapid liquid chromatography–tandem mass spectrometry method employing pre-column derivatization was developed and validated for the determination of alendronate concentrations in human plasma. The procedure was based on derivatization with trimethylsilyldiazomethane during solid-phase extraction on a weak anion-exchange solid-phase cartridge, which integrated sample purification and derivatization into one step. The alendronate derivative was eluted with methanol. Chromatographic separation was performed on a Capcell PAK-C18 column. The total run time was 6.5 min. The calibration curve was linear in the range 1.00–1,000 ng/mL using d6-alendronate as the internal standard. The lower limit of quantification was 1.00 ng/mL. The intra- and inter-assay precision (in RSD) calculated from quality control samples was less than 15%, and the accuracy was between 98.1% and 100.2%. The validated method was successfully applied to characterize the pharmacokinetic profiles of alendronate following the intravenous infusion of 5 or 10 mg alendronate sodium to healthy volunteers.  相似文献   

2.
Hui-Fang Hsieh 《Talanta》2009,79(2):183-240
This work describes a simple procedure for blood lead level determination. The proposed method requires little sample pretreatment and subsequent direct analysis of a dried blood spot on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). In general, LA-ICP-MS studies are somewhat limited by the lack of matrix-matched standards for calibration purposes. Here we describe aqueous standard calibration and matrix-matched calibration methods. This method was validated by analysis of the reference materials. With the matrix-matched calibration method, the recovery ranged from 97.8% to 112.8%, while the aqueous standard calibration method ranged 90.4% to 122.4%. The lower detection limit was estimated as 0.1 ng mL−1. The determination precision, expressed as the relative standard deviation (RSD), was not worse than 10% for all results. A sample throughput of approximately 5 min per sample made it possible to rapidly screen a large number of samples.  相似文献   

3.
Abstract

A liquid chromatographic method is described for the determination of the new fluoroquinolone Ro 23–6240 and its N-demethyl and N-oxide metabolites in plasma and urine. The three substances were extracted from aqueous solution with dichloromethane/isopropanol containing sodium dodecyl sulphate. After evaporation and reconstitution, samples were analysed on a reversed-phase column using ion pair chromatography and fluorescence detection. The limit of quantification was 10–20 ng/ml (RSD 4%) using a 0.5 ml plasma sample, and the inter assay precision was 3–10% over the concentration range 50 ng/ml to 20 μg/ml. Recovery from plasma was 81% (RSD 10%) over the range 10 ng/ml to 5 μg/ml. The method has been applied successfully to the analysis of several thousand samples from human pharmacokinetic studies. Care has to be taken to avoid exposure of samples to direct sunlight, and the use of opaque vessels for sample storage and handling is recommended.  相似文献   

4.
A capillary electrophoretic (CE) assay for oxalate has been applied to the quantitative determination of free oxalate in amniotic fluid. Indirect absorbance detection of oxalate is accomplished with a chromate-based background electrolyte modified with ethylenediaminetetraacetic acid (EDTA). Detection interference due to the presence of high levels (≈4 mg/ml) of inorganic chloride is eliminated through a direct sample clean-up procedure based on cation (Ag+-form) resins. Separation interference from amniotic fluid proteins is prevented through the use of a simple aqueous-based dilution procedure. This method for the determination of oxalate in amniotic fluid provides precision of ≈5% relative standard deviation (RSD). Within-day precisions for the oxalate response and migration time are better than 3% RSD and 1% RSD, respectively. Between-day precisions for the oxalate response and migration time are better than 6% RSD and 3% RSD, respectively. The analytical recovery of oxalate (1000 ng/ml) spiked into amniotic fluid was better than 96%. The limit of detection (LOD) for the method is ≈100 ng/ml oxalate. This method also shows promising results for the determination of oxalate in human blood plasma samples.  相似文献   

5.
An improved assay for the determination of rofecoxib in human plasma samples is described. The analyte and an internal standard were extracted from the plasma matrix using solid-phase extraction in the 96-well format with an Empore C8-SD extraction plate. The analytes are chromatographed on a Waters Symmetry C18 analytical column (3.5 microm, 50x4.6 mm) with a mobile phase consisting of acetonitrile-water (35:65, v/v). Analyte detection was via fluorescence following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 0.5-80 ng/ml yielded a linear response when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n=5) of spiked standards, the within-day assay precision was better than 8% RSD at all points on the calibration curve, within-day accuracy was within 6% of nominal at all standard concentrations. The between-run precision and accuracy of the assay, as calculated from the results of the analysis of quality control samples, was better than 7% RSD and within 5% of nominal. Assay throughput was improved by a factor of three as compared to previously described methods. The method was partially automated using a combination of a Packard Multi-Probe liquid handling system and a TomTec Quadra 96 workstation.  相似文献   

6.
A relatively simple, sensitive and rapid high-performance liquid chromatographic method is described for measuring the anticancer drug 5-fluorouracil (5-FU) in human plasma and urine. The procedure includes liquid-liquid extraction using ethyl acetate-methanol (95:5) and preparative column chromatography to separate 5-FU from constituents normally occurring in these biological samples. The columns contained a specially modified form of diatomaceous earth, which requires no pre-conditioning washes. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70 mm x 4.6 mm I.D.) with a mobile phase of water-methanol (95:5) and ultraviolet detection (268 nm). The overall recovery from plasma and urine was 91 and 94%, respectively, at the concentration of 50 ng/ml. The determination limit of the assay for 5-FU was 10 ng/ml of plasma and urine. Concentrations of 5-FU between 10 and 500 ng/ml were measured in plasma and urine with a relative standard deviation of 6.8%. In order to evaluate the procedure, plasma and urine samples from three patients treated with 5-FU by continuous intravenous perfusion, were investigated.  相似文献   

7.
Capillary zone electrophoresis (CZE) was used for the rapid determination of 5-fluorouracil (5-FU) and 5-fluoro-2'-deoxyuridine-5'-monophosphate (FdUMP) in pancreatic cancer cell line (PANC-1), culture medium, plasma and pancreatic tissue. The assay is based upon protein precipitation with acetonitrile followed by a 9-min CZE analysis of the supernatant in an uncoated fused-silica capillary employing a borate buffer and on-column absorbance detection at 265 nm. Using 50 microl of sample, 5-FU levels between 4.12 and 132 microg/ml (31.7-1000 microM) were found to provide linear calibration graphs. Intra-day and inter-day RSD values evaluated from peak height ratios (n=5) were <7.6 and <8.8%, respectively. Corresponding RSD values of detection times (n=7) were <1 and <1.5%, respectively. The limits of detection for 5-FU and FdUMP were 1.72 and 5.29 microg/ml, respectively. As application, the accumulation of 5-FU by PANC-1 cells over a 4-h time period was investigated. Having a culture medium concentration of 100 microg/ml, the 5-FU cell content was estimated to become equal to that of the surrounding medium (i.e., 100 microg/ml or 3.61 fmol per cell with a volume of 4.7 pl) within that time period. The sensitivity of the assay was sufficient for the determination of 5-FU in all cell samples. FdUMP, however, could not be detected in these samples. Furthermore, the data obtained in uncoated capillaries are compared to those measured in a fused-silica capillary whose inner surface was coated with linear polyacrylamide (about 10-fold reduction of electroosmosis). The latter capillary format was found to be useless for simultaneous analysis of 5-FU and FdUMP in pancreatic cells but could be potentially useful for analysis of these compounds in plasma.  相似文献   

8.
A method for the determination of stale-flavor carbonyl compounds including E-2-octenal, E-2-nonenal, E,Z-2,6-nonadienal and E,E-2,4-decadienal in beer was developed using stir bar sorptive extraction (SBSE) with in-situ derivatization followed by thermal desorption-GC-MS analysis. The derivatization conditions with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine and the SBSE conditions--sampling mode, salt addition, sample volume, polydimethylsiloxane volume (sample/polydimethylsiloxane phase ratio) and extraction time--were examined. The method showed good linearity over the concentration range from 0.1 to 10 ng ml(-1) for all analytes and the correlation coefficients were higher than 0.9993. The limits of detection ranged from 0.021 to 0.032 ng ml(-1) for all analytes. The recoveries (98-101%) and precision (RSD 2.4-7.3%) of the method were examined by analyzing beer samples fortified at the 0.5-ng ml(-1) level. The method was successfully applied to low-level concentration samples.  相似文献   

9.
The simultaneous determination of several odorous trichlorobromophenols in water has been carried out by an in-sample derivatization headspace solid-phase microextraction method (HS-SPME).The analytical procedure involved their derivatization to methyl ethers with dimethyl sulfate/NaOH and further HS-SPME and gas chromatography-mass spectrometry (GC/MS) determination. Parameters affecting both the derivatization efficiency and headspace SPME procedures, such as the selection of the SPME fiber coating, derivatization–extraction time and temperature, were studied. The commercially available polydimethylsiloxane (PDMS) 100 μm and Carboxen-polydimethylsiloxane-divinylbenzene (CAR-PDMS-DVB) fibers appeared to be the most suitable for the simultaneous determination of these compounds. The precision of the HS-SPME/GC/MS method gave good relative standard deviations (RSDs) run-to-run between 9% and 19% for most of them, except for 2,5-diCl-6-Br-phenol, 2,6-diCl-3-Br-phenol and-2,3,6-triBr-phenol (22%, 25% and 23%, respectively). The method was linear over two orders of magnitude, and detection limits were compound dependent but ranged from 0.22 ng/l to 0.95 ng/l. The results obtained for water samples using the proposed SPME procedure were compared with those found with the EPA 625 method, and good agreement was achieved. Therefore, the in-sample derivatization HS-SPME/GC/MS procedure here proposed is a suitable method for the simultaneous determination of odorous trichlorobromophenols in water.  相似文献   

10.
This paper describes a method for the sensitive and selective determination of glyphosate, glufosinate and aminomethylphosphonic acid (AMPA) residues in water and soil samples. The method involves a derivatization step with 9-fluorenylmethylchloroformate (FMOC) in borate buffer and detection based on liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS). In the case of water samples a volume of 10 mL was derivatized and then 4.3 mL of the derivatized mixture was directly injected in an on-line solid phase extraction (SPE)-LC-MS/MS system using an OASIS HLB cartridge column and a Discovery chromatographic column. Soil samples were firstly extracted with potassium hydroxide. After that, the aqueous extract was 10-fold diluted with water and 2 mL were derivatized. Then, 50 microL of the derivatized 10-fold diluted extract were injected into the LC-MS/MS system without pre-concentration into the SPE cartridge. The method has been validated in both ground and surface water by recovery studies with samples spiked at 50 and 500 ng/L, and also in soil samples, spiked at 0.05 and 0.5 mg/kg. In water samples, the mean recovery values ranged from 89 to 106% for glyphosate (RSD <9%), from 97 to 116% for AMPA (RSD < 10%), and from 72 to 88% in the case of glufosinate (RSD < 12%). Regarding soil samples, the mean recovery values ranged from 90 to 92% for glyphosate (RSD <7%), from 88 to 89% for AMPA (RSD <5%) and from 83 to 86% for glufosinate (RSD <6%). Limits of quantification for all the three compounds were 50 ng/L and 0.05 mg/kg in water and soil, respectively, with limits of detection as low as 5 ng/L, in water, and 5 microg/kg, in soil. The use of labelled glyphosate as internal standard allowed improving the recovery and precision for glyphosate and AMPA, while it was not efficient for glufosinate, that was quantified by external standards calibration. The method developed has been applied to the determination of these compounds in real water and soil samples from different areas. All the detections were confirmed by acquiring two transitions for each compound.  相似文献   

11.
A quantitative bioanalytical method involving chemical derivatization, solid phase extraction (SPE) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was developed for the determination of 4-fluorobenzyl chloride (4FBCl) in human plasma. 4FBCl is a volatile and reactive molecule that is very unstable in human plasma. In order to stabilize 4FBCl in plasma samples prior to storage, 4-dimethylaminopyridine (DMAP) was added, forming a stable quaternary amine salt derivative. A three-step weak cation-exchange SPE procedure was then employed to remove excess DMAP. The plasma extracts were analyzed by HPLC/MS/MS using a TurboIonspray interface and multiple reaction monitoring. Unlike 4FBCl, the quaternary amine derivative shows excellent sensitivity in electrospray mass spectrometry. The method was validated over a concentration range of 0.5-500 ng/mL using 45 microL of plasma. The maximum within-run and between-run precision observed in a three-run validation for quality control (QC) samples was 12.5 and 7.6%, respectively. The maximum percentage bias observed at all QC sample concentrations was 11.9%. The method has proven to be robust and compatible with high-throughput bioanalysis.  相似文献   

12.
A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD 相似文献   

13.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

14.
For the first time, an enzyme-linked immunosorbent assay (ELISA) has been developed and validated for the determination of fluvastatin (FLV) in plasma samples at picogram level. The assay employed a polyclonal antibody that specifically recognizes FLV with high affinity, and FLV conjugate of bovine serum albumin (FLV-BSA) immobilized onto microplate wells as a solid-phase. The assay involved a competitive binding reaction between FLV, in plasma sample, and the immobilized FLV-BSA for the binding sites on a limited amount of the anti-FLV antibody. The bound anti-FLV antibody was quantified with horseradish peroxidase-labeled second anti-rabbit IgG antibody (HRP-IgG) and 3,3′,5,5′-tetramethylbenzidine (TMB) as a substrate for the peroxidase enzyme. The concentration of FLV in the sample was quantified by its ability to inhibit the binding of the anti-FLV antibody to the immobilized FLV-BSA and subsequently the color intensity in the assay wells. The conditions for the proposed ELISA were investigated and the optimum conditions were employed in the determination of FLV in plasma samples. The assay limit of detection was 10 pg mL−1 and the effective working range at relative standard deviations (RSD) of ≤5% was 20-1000 pg mL−1. Analytical recovery of FLV from spiked plasma was 97.1-102.7 ± 2.85-6.25%. The precision of the assay was satisfactory; RSD was 2.46-5.37 and 3.19-6.64% for the intra- and inter-assay precision, respectively. The analytical procedure is convenient, and one can analyze ∼200 samples per working day, facilitating the processing of large-number batch of samples. The proposed ELISA has a great value in routine analysis of FLV for its therapeutic monitoring and pharmacokinetic studies.  相似文献   

15.
An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formulas and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 for powders and 50 for liquids. The Cr, Se, and Mo concentrations in 10 nutritional products were within specification limits, and within-day and day-to-day (6 independent days) precision values were <5% RSD. For two control samples, the observed precision was < or = 2% RSD over 10 independent days. In three National Institute of Standards and Technology standard reference materials, Cr, Se, and Mo results were within the certified limits. The average sample spike recoveries for 10 nutritional products ranged from 93 to 107%. Robustness studies showed a minimal effect from concomitant easily ionized element concentrations. However, the choice of internal standard and matrix matching carbon content were critical to obtaining accurate Se results. All indications are that this method would be a suitable candidate as a global reference method for the determination of these trace elements in nutritional products.  相似文献   

16.
An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formula and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 for powders and 50 for liquids. The Cr, Se, and Mo concentrations in 10 nutritional products were within specification limits; within-day and day-to-day (6 independent days) precision values were <5% RSD. For two control samples, the observed precision was < or = 2% RSD over 10 independent days. Cr, Se, and Mo results were within the certified limits in three National Institute of Standards and Technology standard reference materials. The average sample spike recoveries for 10 nutritional products ranged from 93 to 107%. Robustness studies showed a minimal effect from concomitant easily ionized element concentrations. However, the choice of internal standard and matrix-matching carbon content were critical to obtaining accurate Se results. All indications are that this method would be a suitable candidate as a global reference method for the determination of these trace elements in infant formula, adult nutritionals, and other nutritional  相似文献   

17.
Dexmedetomidine (Dex) is a selective central α2‐agonist with anesthetic properties and has been used in clinical practice for sedation in the intensive care unit (ICU) after operations. In this study, an analytical assay for the determination of Dex in a small amount of plasma was developed for the application to pediatric ICU trials. The quantification of Dex was constructed using the original stable isotope Dex‐d3 for electrospray ionization‐tandem mass spectrometry (ESI‐MS/MS) in the selected reaction monitoring mode. A rapid ultra‐performance liquid chromatography technique was adopted using ESI‐MS/MS with a runtime of 3 min. Efficacious concentration levels (50 pg/mL to 5 ng/mL) could be evaluated using a very small amount of plasma (10 μL) from patients. The lower limit of the quantification was 5 pg/mL in the plasma (100 µL). For sample preparation, a solid‐phase extraction was used along with the OASIS‐HLB cartridge type. Recovery values ranged from 98.8 to 100.3% for the intra‐ [relative standard deviation (RSD), 0.9–1.3%] and inter‐ (RSD, 0.9–1.5%) day assays. A stable test had recovery values that ranged from 97.8 to 99.7% with an RSD of 1.0–1.9% for the process/wet extract, bench‐top, freeze–thaw and long‐term tests. This method was used to measure the Dex levels in plasma from pediatric ICU patients. In the clinical ICU trial, the small amount of blood (approximate plasma volume, 200 μL) remaining from blood gas analysis was reused and targeted for the clinical analysis of Dex in plasma. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
Chronic bacterial prostatitis treatment consists of broad‐spectrum antibiotic therapy for long periods of time. Drug penetration into the prostate makes the treatment a challenged. Ciprofloxacin is one of the most prescribed drugs for this treatment. A liquid chromatography with fluorescence detection method was developed and validated for determining ciprofloxacin concentrations in two different matrices: plasma and prostate microdialysate. Ciprofloxacin was separated on a C18 column eluted with a mobile phase constituted of a mixture of 0.4% aqueous triethylamine:methanol:acetonitrile (75:15:10, v/v/v) and 0.4% aqueous triethylamine:acetonitrile (88:12, v/v) for microdialysate and plasma samples, respectively. Linearity was obtained over a concentration range of 5–1000 ng/mL (microdialysate) and 10–2000 ng/mL (plasma), with coefficients of determination ≥0.9956. Precision was determined from the analysis of six quality control samples and showed RSD values <11.1 and 7.4% for intra and inter‐assay precision, respectively. The accuracy ranged from 85.6 to 114.3%. The method was applied to a preliminary pharmacokinetic study to investigate ciprofloxacin concentrations in prostate, sampled by microdialysis, and plasma after a 7 mg/kg intravenous dose to Wistar rats. The method showed high sensitivity using only protein precipitation as plasma sample clean‐up and was successfully applied to investigate ciprofloxacin prostate penetration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multiresidue method for the simultaneous quantitative determination of oxytetracycline, 4-epi-oxytetracycline, tetracycline, 4-epi-tetracycline, chlortetracycline, 4-epi-chlortetracycline and doxycycline in milk has been developed. An extraction procedure consisting of a liquid extraction of the milk samples with trichloroacetic acid was performed. The extract was centrifuged and the supernatant was filtered. Solid-phase extraction (SPE) with an OASIS HLB SPE column was used to clean up the sample extracts. The samples were analysed by LC/MS/MS. The LC separation was performed on a reversed-phase C18 column using gradient elution with a mobile phase consisting of water and a mixture of methanol/acetonitrile. The tetracycline analytes were detected with a quadrupole mass spectrometer using positive ion electrospray ionisation. The confirmatory method has acceptable detection limits and the different tetracyclines can be detected at a residue concentration between 5 and 20 microg/L. The method is validated according to the European requirements for veterinary drug residues and all determined parameters were found to conform to the criteria. The recovery values ranged from 90.4 to 101.2% with relative standard deviations (RSDs) no larger than 9.7%. The overall or between-day precision of the analytical assay determined as repeatability at several residue concentrations and expressed as RSD ranged from 3.3 to 10%. This analytical assay is a useful tool within the Belgian monitoring programme for confirmation of samples which have been positively screened for residues of tetracyclines in raw farm cow's milk.  相似文献   

20.
A new, rapid analytical method, based on liquid chromatography with diode array detection, has been developed and applied to the determination of risperidone and its main active metabolite 9-hydroxyrisperidone in human plasma. The chromatographic separation was obtained on a C8 (150 x 4.6 mm, 5 microm) column, using a mobile phase composed of acetonitrile (27%) and a pH 3.0 phosphate buffer (73%). A sample clean-up procedure was carried out by using C8 cartridges and eluting the analytes with methanol. The extraction yield was highly satisfactory for both analytes, with average absolute recovery values of about 95%. The experimental conditions permitted the quantitative determination of risperidone and 9-hydroxyrisperidone with high precision (RSD < 3.6%) and satisfactory sensitivity (LOQ = 4 ng mL(-1)). The method was applied to plasma samples from a patient who had tried to poison himself with 150 mg of risperidone, and was undergoing polypharmacy.  相似文献   