首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Six different tandem-mass-spectrometric experiments were evaluated to assess their ability to distinguish four isomeric, carcinogen-modified adenines. Metastable-ion dissociations and high-energy collisional activated decompositions (HE CAD) of fast-atom bombardment (FAB)-produced ions were followed on a four-sector tandem mass spectrometer. Precursor ions were also produced by electrospray on the four-sector instrument, and they were submitted to both high-energy and electrospray ionization (ESI)-source CAD. We contrasted these means of activation with low-energy (LE) CAD of electrospray-produced ions on a triple quadrupole instrument and with post-source decompositions (PSD) of ions produced by matrix-assisted laser desorption ionization (MALDI). The latter experiment was conducted with a time-of-flight mass spectrometer. The four subject molecules were isomeric dibenzo[a,l]pyrene (DB[a,l]P) adenine adducts, in which N1, N3, N7, and N 6 positions were substituted. We used similarity indicies (SI), which were calculated from the relative abundances of common fragment ions for the isomers, to confirm quantitatively that HE CAD of FAB and ESI-produced ions can distinguish two of three, and that LE CAD and MALDI-PSD can distinguish three of the three isomers that give qualitatively identical product-ion spectra. The results also show that LE CAD and MALDI-PSD have comparable discriminating capability for these three DBP adducts.  相似文献   

2.
We have prepared a number of isomeric red seaweed galactan-derivative sulfated oligosaccharides to determine whether there were diagnostic differences among the isomeric mass spectra obtained using ESI CID MS/MS (triple quadrupole instrument). Fragmentation of the single or multicharged molecular ions from di-, tetra-, and hexasaccharides indicated that the relative positioning of the sulfate groups and type of monosaccharide unit affect the rate of cleavage of the glycosidic bonds. We also performed a comparative [M-Na] fragmentation study of positional isomers of sulfated disaccharides that present all four monosulfation possibilities on the galactopyranosidic ring. In this case, negative-ion ESI CID MS/MS approach gave diagnostic product ions from cross-ring cleavages along with the same main B1 ion (from sulfated Galp), at m/z 241, for all isomers. The isomeric disaccharides were also submitted to increased spray energy conditions inducing in-source fragmentation; preformed B1 ions were then fragmented to give similar product ions as those found in [M-Na] analysis. Evaluation of the relative abundances mainly for cross-ring fragment ions at m/z 138, 139, 151, 153 allowed clear distinction among the members of the disaccharide series. The different ratios for m/z 151/153 ions were consistent with the predominance of m/z 153 being related to the cases when the bond involved in the cleavage process links a sulfated carbon. A quadrupole ion trap instrument (MSn analysis) was also utilized to compare the results obtained with the triple quadrupole instrument.  相似文献   

3.
Sialylated O‐linked oligosaccharides are involved in many biological processes, such as cell‐cell interactions, cell‐substance adhesion, and virus‐host interactions. These activities depend on their structure, which is frequently determined by tandem mass spectrometry. However, these spectra are frequently analyzer‐dependent, which makes it difficult to develop widely applicable analytical methods. In order to deepen the origin of this behavior, two couples of isomers of sialylated O‐linked oligosaccharides, NeuAcα2‐3Galβ1‐3GalNAc‐ol/Galβ1‐3(NeuAcα2‐6)GalNAc‐ol and NeuGcα2‐3Galβ1‐3GalNAc‐ol/Galβ1‐3(NeuGcα2‐6)GalNAc‐ol, were analyzed by liquid chromatography/negative electrospray ionization ion trap tandem mass spectrometry (LC/ESI(?)‐MSn) using both an ion trap and a triple quadrupole mass spectrometer. Results clearly showed that while ions obtained in the triple quadrupole instrument fitted very well with the standard fragmentation routes, in the ion trap several intense ions could not be explained by these rules, specially a fragment at m/z 597. Furthermore, this ion was observed in the mass spectrum of those isomers that sialic acid binds to GalNAc by an α2‐6 linkage. From the MS3 spectrum of this ion an unexpected structure was deduced, and it led to propose alternative fragmentation pathways. Molecular mechanics calculations suggested that the found atypical route could be promoted by a hydrogen bond located only in α2‐6‐linked oligosaccharides. It has also been demonstrated that this process follows a slow kinetic, explaining why it cannot be observed using an ion beam‐type mass analyzer. In conclusion, ion traps seem to be more appropriate than triple quadrupoles to develop a reliable analytical method to distinguish between isomeric O‐linked glycans. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The aim of this study was to investigate the fragmentation behavior induced by low‐energy collision‐induced dissociation (LE‐CID) of four selected antioxidants applied in lubricants, by two different types of ion trap mass spectrometers: a three‐dimensional ion trap (3D‐IT) and a linear IT (LIT) Orbitrap MS. Two sterically hindered phenols and two aromatic amines were selected as model compounds representing different antioxidant classes and were characterized by positive‐ion electrospray ionization (ESI) and LE‐CID. Various types of molecular ions (e.g. [M]+?, [M + H]+, [M + NH4]+ or [M + Na]+) were used as precursor ions generating a significant number of structurally relevant product ions. Furthermore, the phenolic compounds were analyzed by negative‐ion ESI. For both IT types applied for fragmentation, the antioxidants exhibited the same unusual LE‐CID behavior: (1) they formed stable radical product ions and (2) C? C bond cleavages of aliphatic substituents were observed and their respective cleavage sites depended on the precursor ion selected. This fragmentation provided information on the type of structural isomer usually not obtainable for branched aliphatic substituents utilizing LE‐CID. Comparing the two instruments, the main benefit of applying the LIT‐Orbitrap was direct access to elemental composition of product ions enabling unambiguous interpretation of fragmentation trees not obtainable by the 3D‐IT device (e.g. loss of isobaric neutrals). It should be emphasized that the types of product ions formed do not depend on the type of IT analyzer applied. For characterizing degradation products of antioxidants, the LIT‐Orbitrap hybrid system, allowing the determination of accurate m/z values for product ions, is the method of choice. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
In this study positive ESI tandem mass spectra of the [M + H]+ ions of morphinan alkaloids obtained using an ion trap MS were compared with those from a triple quadrupole MS. This allows to assess the differences of the tandem-in-time versus the tandem-in-space principle, often hampering the development of ESI MS/MS libraries. Fragmentation pathways and possible fragment ion structures were discussed. In order to obtain elemental composition, accurate mass measurements were performed. According to the MS/MS fragmentation pathway, the investigated compounds can be grouped into 4 subsets: (1) morphine and codeine, (2) morphinone, codeinone, and neopinone, (3) thebaine and oripavine, (4) salutaridine and salutaridinol. Salutaridinol-7-O-acetate shows a different fragmentation behavior because of the favored loss of acetic acid. Although most fragment ions occur in both ion trap and triple quad tandem mass spectra, some are exclusively seen in either type. For triple quad, quadrupole time-of-flight and FT-ICR MS/MS, the base peak of morphine results from an ion at m/z 165 that contains neither nitrogen nor oxygen. This ion is not found in ion trap MS/MS, but in subsequential MS3 and MS4.  相似文献   

6.
Transmission mode ion/ion reactions have been performed within the first quadrupole, the Q0 radiofrequency (RF)‐only quadrupole, of two types of hybrid tandem mass spectrometers (viz., triple quadrupole/linear ion trap and QqTOF instruments). These transmission mode reactions involved the storage of either the reagent species and the transmission of the analyte species through the Q0 quadrupole for charge inversion reactions or the storage of the analyte ions and transmission of the reagent ions as in charge reduction experiments. A key advantage to the use of transmission mode ion/ion reactions is that they do not require any instrument hardware modifications to provide interactions of oppositely charged ions and can be implemented in any instrument that contains a quadrupole or linear ion trap. The focus of this work was to investigate the potential of using the RF‐only quadrupole ion guide positioned prior to the first mass‐resolving element in a tandem mass spectrometer for ion/ion reactions. Two types of exemplary experiments have been demonstrated. One involved a charge inversion reaction and the other involved a charge reduction reaction in conjunction with ion parking. Ion/ion reactions proved to be readily implemented in Q0 thereby adding significantly greater experimental flexibility in the use of ion/ion reaction experiments with hybrid tandem mass spectrometers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
The use of hybrid quadrupole ion mobility spectrometry time‐of‐flight mass spectrometry (Q/IMS/TOFMS) in the metabolite profiling of leflunomide (LEF) and acetaminophen (APAP) is presented. The IMS drift times (Td) of the drugs and their metabolites were determined in the IMS/TOFMS experiments and correlated with their exact monoisotopic masses and other in silico generated structural properties, such as connolly molecular area (CMA), connolly solvent‐excluded volume (CSEV), principal moments of inertia along the X, Y and Z Cartesian coordinates (MI‐X, MI‐Y and MI‐Z), inverse mobility and collision cross‐section (CCS). The correlation of Td with these parameters is presented and discussed. IMS/TOF tandem mass spectrometry experiments (MS2 and MS3) were successfully performed on the N‐acetyl‐p‐benzoquinoneimine glutathione (NAPQI‐GSH) adduct derived from the in vitro microsomal metabolism of APAP. As comparison, similar experiments were also performed using hybrid triple quadrupole linear ion trap mass spectrometry (QTRAPMS) and quadrupole time‐of‐flight mass spectrometry (QTOFMS). The abilities to resolve the product ions of the metabolite within the drift tube and fragment the ion mobility resolved product ions in the transfer travelling wave‐enabled stacked ring ion guide (TWIG) demonstrated the potential applicability of the Q/IMS/TOFMS technique in pharmaceutical metabolite profiling. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The formation and collisionally activated dissociation (CAD) behavior of a series of complexes containing cyclic or linear diketone ligands and alkali, alkaline earth, or transition metal ions are investigated. Electrospray ionization (ESI) is utilized for introduction of the metal ion complexes into a quadrupole ion trap mass spectrometer. The proximity of the carbonyl groups is crucial for formation and detection of ion complexes by ESI. For example, no metal ion complexes are observed for 1,4-cyclohexanedione, but they are readily detected for the isomers, 1,2-and 1,3-cyclohexanedione. Although the diketones form stable doubly charged complexes, the formation of singly charged alkaline earth complexes of the type (nL + M2+ ? H+)+ where L = 1,3-cyclohexanedione or 2,4-pentanedione is the first evidence of charge reduction. CAD investigations provide further evidence of charge reduction processes occurring in the gas-phase complexes. The CAD studies indicate that an intramolecular proton transfer between two diketone ligands attached to a doubly charged metal ion, followed by elimination of the resulting protonated ligand, produces the charge reduced complex. For transition metal complexation, the preference for formation of doubly charged versus singly charged complexes correlates with the keto-enol distribution of the diketones in solution.  相似文献   

9.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Low-energy (LE) and high-energy (HE) collisionally activated decompositions (CAD) of calcium/peptide complexes of the form [M-H+Ca]+ and [M+Ca]2+ reflect the site of calcium binding in various gas-phase peptides that are models of the calcium binding site III of rabbit skeletal troponin C. The Ca2+ binding sites involve an aspartic acid, glutamic acid, and asparagine, which are in the metal-binding loops of calcium-binding proteins. Both fast atom bombardment (FAB) and electrospray ionization (ESI) were used to generate the metal/peptide complexes. When submitted to LE CAD, ESI-produced Ca2+/peptide complexes undergo fragmentations that are controlled by Ca2+ binding and provide information on the Ca2+ binding site. The LE CAD spectra are simple, indicating that Ca2+ binding involves specific oxygen ligands including acidic side chains and that only a few low-energy fragmentation channels exist. The HE CAD spectra of FAB-produced Ca2+/peptide complexes are more complex, owing to the introduction of high internal energy into the precursor ion. Interactions of the other alkaline-earth metal ions Mg2+ and Ba2+ with these peptides reveal that the ligand preferences of these metal ions are slightly different than those of Ca2+.  相似文献   

11.
We applied electrospray ionization (ESI) tandem quadrupole mass spectrometry to establish the fragmentation pathways of ceramides under low energy collisional-activated dissociation (CAD) by studying more than thirty compounds in nine subclasses. The product-ion spectra of the [M + Li]+ ions of ceramides contain abundant fragment ions that identify the fatty acyl substituent and the long-chain base (LCB) of the molecules, and thus, the structure of ceramides can be easily determined. Fragment ions specific to each ceramide subclasses are also observed. These feature ions permit differentiation among different ceramide subclasses. The ion series arising from the classical C-C bond cleavages that were reported in the fast-atom bombardment (FAB)-high energy tandem mass spectrometry is not observable; however, the product-ion spectra contain multiple fragment ions informative for structural characterization and isomer identification. We also investigated the tandem mass spectra of the fragment ions generated by in-source CAD (pseudo-MS3) and of the deuterium-labeling molecular species obtained by H/D exchange to support the ion structure assignments and the proposed fragmentation pathways that lead to the ion formation.  相似文献   

12.
Novel instrumentation has been developed which allows for the sequential injection and subsequent reaction of oppositely-charged ions generated via electrospray ionization (ESI) in a quadrupole ion trap mass spectrometer. The instrument uses a DC turning quadrupole to sequentially direct the two ion polarities into the ion trap from ESI sources which are situated 90 degrees from the axial (z) dimension of the trap, and 180 degrees from one another. This arrangement significantly expands the range of ionic reactants amenable to study over previously-used instrumentation. For example, ion/ion reactions of multiply-charged positive ions with multiply-charged negative ions can be studied. Also, reactions of multiply-charged ions with singly-charged ions of opposite polarity that could not be generated by previously used ionization methods, or that could not be efficiently injected through the ion trap ring electrode, can be studied with the new instrument. This capability allows, for example, the charge state manipulation of negatively-charged precursor and product ions derived from proteins and oligonucleotides via proton transfer reactions with singly-charged cations generated by ESI.  相似文献   

13.
Tandem mass spectrometric data from peptides are routinely used in an unsupervised manner to infer product ion sequence and hence the identity of their parent protein. However, significant variability in relative signal intensity of product ions within peptide tandem mass spectra is commonly observed. Furthermore, instrument‐specific patterns of fragmentation are observed, even where a common mechanism of ion heating is responsible for generation of the product ions. This information is currently not fully exploited within database searching strategies; this motivated the present study to examine a large dataset of tandem mass spectra derived from multiple instrumental platforms. Here, we report marked global differences in the product ion spectra of protonated tryptic peptides generated from two of the most common proteomic platforms, namely tandem quadrupole‐time‐of‐flight and quadrupole ion trap instruments. Specifically, quadrupole‐time‐of‐flight tandem mass spectra show a significant under‐representation of N‐terminal b‐type fragments in comparison to quadrupole ion trap product ion spectra. Energy‐resolved mass spectrometry experiments conducted upon test tryptic peptides clarify this disparity; b‐type ions are significantly less stable than their y‐type N‐terminal counterparts, which contain strongly basic residues. Secondary fragmentation processes which occur within the tandem quadrupole‐time‐of‐flight device account for the observed differences, whereas this secondary product ion generation does not occur to a significant extent from resonant excitation performed within the quadrupole ion trap. We suggest that incorporation of this stability information in database searching strategies has the potential to significantly improve the veracity of peptide ion identifications as made by conventional database searching strategies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
We investigated the formation of hydroxyl radical (OH·) and H2O2 mediated oxidation products of a synthetic peptide, HCSAGIGRS, which is an active site sequence motif of protein tyrosine phosphatase 1B (PTP1B). We determined that a novel cysteine sulfinamide HC[S(O)N]SAGIGRS is produced in the oxidation reaction by Fenton reagents (Fe+2/H2O2) as well as by H2O2. These products were characterized by tandem mass spectrometry experiments on both singly and doubly charged precursor ions. MS3 experiments using an ion trap instrument as well as LC-MS/MS experiments using a quadrupole time-of-flight (Q-TOF) instrument demonstrated that HC[S(O)N]SAGIGRS is not a water loss product of cysteine sulfinic acid [HC(SO2H)SAGIGRS]. We also obtained data from tandem mass spectrometry experiments that provided evidence for the existence of stable cysteine sulfenic acid [HC(SOH)SAGIGRS] in solution. A mechanism for the formation of the cysteine sulfinamide product is proposed based on the above experimental results. The preparation and identification of cysteine sulfinamide in this study may provide insight into the mechanism of both OH· and H2O2 induced oxidation reactions of protein tyrosine phosphatases.  相似文献   

15.
This paper compares two liquid introduction atmospheric pressure ionization techniques for the analysis of alkyl ethoxysulfate (AES) anionic surfactant mixtures by mass spectrometry, i. e., electrospray ionization (ESI) in both positive and negative ion modes and atmospheric pressure chemical ionization (APCI) in positive ion mode, using a triple quadrupole mass spectrometer. Two ions are observed in ESI(+) for each individual AES component, [M + Na]+ and a “desulfated” ion [M − SO3 + H]+, whereas only one ion, [M − Na] is observed for each AES component in ESI(−). APCI(+) produces a protonated, “desulfated” ion of the form [M − NaSO3 + 2H]+ for each AES species in the mixture under low cone voltage (10 V) conditions. The mass spectral ion intensities of the individual AES components in either the series from ESI(+) or APCI(+) can be used to obtain an estimate of their relative concentrations in the mixture and of the average ethoxylate (EO) number of the sample. The precursor ions produced by either ESI(+) or ESI(−), when subjected to low-energy (50 eV) collision-induced dissociation, do not fragment to give ions that provide much structural information. The protonated, desulfated ions produced by APCI(+) form fragment ions which reveal structural information about the precursor ions, including alkyl chain length and EO number, under similar conditions. APCI(+) is less susceptible to matrix effects for quantitative work than ESI(+). Thus APCI(+) provides an additional tool for the analysis of anionic surfactants such as AES, especially in complex mixtures where tandem mass spectrometry is required for the identification of the individual components.  相似文献   

16.
This work demonstrates the application of electrospray ionization mass spectrometry (ESI-MS) using two different mass analyzers, ion trap and hybrid quadrupole time-of-flight (QqTOF) mass analyzer, for the structural characterization of Ni(II) complexes of Schiff bases of (S)-N-(2-benzoylphenyl)-1-benzylpyrrolidine-2-carboxamide with different amino acids. ESI enables the determination of molecular weight on the basis of rather simple positive-ion ESI mass spectra containing only protonated molecules and adducts with sodium or potassium ions. Fragmentation patterns are characterized by tandem mass spectrometric experiments, where both tandem mass analyzers provide complementary information. QqTOF data are used for the determination of elemental composition of individual ions due to mass accuracies always better than 3 ppm with the external calibration, while multistage tandem mass spectra obtained by the ion trap are suitable for studying the fragmentation paths. The novel aspect of our approach is the combination of mass accuracies and relative abundances of all isotopic peaks in isotopic clusters providing more powerful data for the structural characterization of organometallic compounds containing polyisotopic elements. The benefit of relative and absolute mean mass accuracies is demonstrated on the example of studied Ni(II) complexes. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

17.
The ability to obtain daughter ion formulas via comparison of MSn spectra of parent ions containing only 12C with those of parent ions with one 13C (from the natural 13C abundance) is shown for cases in which isobaric interferences with the 13C-containing ion preclude the use of the conventional tandem mass spectrometric approach. This method allows the presence of isobaric daughter ions to be ascertained, and unexpected, complex dissociation pathways to be identified. A three-dimensional quadrupole ion trap is used for these experiments. Its high tandem mass spectrometry efficiency makes possible this type of experiment.  相似文献   

18.
Electrospray ionization (ESI) tandem mass spectrometry (MS) has simplified analysis of phospholipid mixtures, and, in negative ion mode, permits structural identification of picomole amounts of phospholipid species. Collisionally activated dissociation (CAD) of phospholipid anions yields negative ion tandem mass spectra that contain fragment ions representing the fatty acid substituents as carboxylate anions. Glycerophosphocholine (GPC) lipids contain a quaternary nitrogen moiety and more readily form cationic adducts than anionic species, and positive ion tandem mass spectra of protonated GPC species contain no abundant ions that identify fatty acid substituents. We report here that lithiated adducts of GPC species are readily formed by adding lithium hydroxide to the solution in which phospholipid mixtures are infused into the ESI source. CAD of [MLi+] ions of GPC species yields tandem mass spectra that contain prominent ions representing losses of the fatty acid substituents. These ions and their relative abundances can be used to assign the identities and positions of the fatty acid substituents of GPC species. Tandem mass spectrometric scans monitoring neutral losses of the head-group or of fatty acid substituents from lithiated adducts can be used to identify GPC species in tissue phospholipid mixtures. Similar scans monitoring parents of specific product ions can also be used to identify the fatty acid substituents of GPC species, and this facilitates identification of distinct isobaric contributors to ions observed in the ESI/MS total ion current.  相似文献   

19.
Charged derivatives of peptides are useful in obtaining simpler collision-activated dissociation (CAD) mass spectra. An N-terminal charge-derivatizing reagent capable of reacting with picomole levels of peptide has been recently reported (Huang et al. Anal. Chem. 1997, 69, 137-144) in the contexts of analyses by fast atom bombardment (FAB) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Electrospray ionization (ESI) mass spectrometric investigation of these tris(trimethoxyphenylphosphonium) acetyl derivatives are described in this article, including studies by in-source fragmentation (ISF) and tandem mass spectrometry (MS/MS). Results from ISF are compared with those from MS/MS. Similarities and differences between ESI-ISF, MALDI-post-source decay (PSD), and FAB-CAD data are presented. Differences in fragmentation of these charged derivatives in the triple quadrupole and ion trap mass spectrometers also are discussed. Application of this derivatizing procedure to tryptic digests and subsequent analysis by liquid chromatography-mass spectrometry is also shown.  相似文献   

20.
Electrospray ionization tandem mass spectrometry (ESI‐MSn) using an ion trap instrument and accurate mass measurement on a quadrupole time‐of‐flight (Q‐TOF) mass spectrometer has aided the structural characterization and differentiation of the enmein and spiro‐lactone types of ent‐6,7‐seco‐kaurane diterpenoids from Isodon species. The mass spectral fragmentation data from both techniques was compared to obtain the mass spectrometric fragmentation pathways of the ent‐6,7‐seco‐kaurane diterpenoids with high confidence. The analysis revealed that losses of CH2O and CO2 are the predominant process for the enmein type of ent‐kauranes in negative ion mode, and the loss of CO2 is typical for the spiro‐lactone type in positive ion mode. In addition, compounds of the spiro‐lactone type with a conserved core structure but different substituent groups, such as acetyl, hydroxyl, and aldehyde moiety, resulted in diagnostic product ions by means of successive losses of AcOH, H2O, and CO, respectively. The fragmentation knowledge will facilitate the analysis and identification of the ent‐6,7‐seco‐kauranes in future plant research. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号