首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High resolution capillary gas chromatography–mass spectrometry has been used in combination with various sample preparation methods to analyze a wide range of low molecular weight organic contaminants in municipal wastewaters. Volatile organic compounds were extracted using a purge and trap concentrator connected directly to a wide bore DB-624 capillary column. Because of the high organic load in wastewater samples, this method was preferred to the more sensitive closed loop stripping technique which suffered from competition effects and insufficient adsorbent capacity. Volatile and semi-volatile base/neutral compounds and acids were extracted with dichloromethane at pH 11 and pH 2, respectively, or were recovered using a simultaneous distillation-extraction procedure. Acidic compounds were subsequently derivatized using diazomethane methylation. Both fractions were separated with a 30m DB-5ms capillary column. Specific ionic substances (LAS, NTA, EDTA) were isolated by solid-phase extraction then derivatized with diazomethane (LAS) or acetyl chloride in n-butanol (NTA, EDTA) before GC–MS analysis. This array of techniques enabled the identification of more than 150 organic contaminants in the influent of a municipal wastewater treatment plant in northern suburban Paris. The individual concentrations of these contaminants ranged from < 0.1 μg/l to 5.7 mg/l.  相似文献   

2.
Analysis of terpenes in white wines using SPE-SPME-GC/MS approach   总被引:3,自引:0,他引:3  
Terpenes contribute to some white wines aroma, especially these produced from Muscat grapes and others aromatic ones of high terpene contents (Gewürtztramminer, Traminer, Huxel, Sylvaner). Terpenes are present in wine in free and bound (in a form of glycosides) forms. Analyses of bound terpenes are usually performed using solid phase extraction after hydrolysis of glycosides. A new method for determination of terpenes from wine, focused on determination of terpenes released after acidic hydrolysis, based on solid phase extraction (SPE) followed by solid phase microextraction (SPME) was developed. Non-polar (free) and polar (bound terpenes) fractions were separated on 500 mg C18 cartridges. Bound terpenes were sampled using SPME immediately after acidic hydrolysis in non-equilibrium conditions. Application of combined SPE-SPME approach allowed quantification of selected terpenes in lower concentrations than in SPE approach and added a selectivity to the method, which enabled detection of compounds non-detectable in SPE extracts. Results obtained by SPE and SPE-SPME approach were correlated for free terpenes and those released after acid hydrolysis 20 white wines obtained from different grape varieties (R2 = 0.923). Although developed for wine terpenes analysis, SPE followed by SPME approach has a great potential in analysis of other bound wine flavor compounds, especially those potent odorants present in trace amounts.  相似文献   

3.
A novel sulfur-bearing secondary antioxidant with a high molecular weight of 2252 (OS-POSS), successfully synthesized via photoinitiated thiol-ene click reaction, was compared with two commercial sulfur-bearing secondary antioxidants on the stabilization of polypropylene (PP). The results of their oxidation induction time (OIT) via differential scanning calorimeter measurement (DSC) showed that the higher the molecular weight of secondary antioxidant is, the longer the OIT value, whether such sulfur-bearing antioxidant is used singly or in combination with primary antioxidant. The study of their long-term accelerated thermal aging in the air oven at 150 °C displayed that the molecular structure of sulfur-bearing secondary antioxidant, besides molecular weight, is another highly important factor determining the antioxidant efficiency, i.e., physical loss of antioxidants with the relatively low molecular weight may determine antioxidant efficiency, whereas thioether groups having neighboring ester carbonyl moieties may decompose more hydroperoxides with quicker rate.  相似文献   

4.
PP samples, in which the three unique carbon atom positions along the chain were selectively labeled with C-13, have been subjected to γ-irradiation in the presence of oxygen, and the resulting organic volatile products analyzed by GC/MS. The isotopic labeling patterns in 33 organic degradation compounds have been assigned by comparison of the four mass spectra for each compound (from unlabeled PP, and from the three labeled PP materials). The volatile products have been “mapped” onto their positions of origin from the PP macromolecule, and insights have been gained into the chemistry through which these compounds must have formed. Most products show high specificity of isotopic labeling, indicating a single dominant reaction pathway. Oxidation chemistry occurred heavily at the C(2) tertiary carbon, with chemistry also at C(1) methylene. Methyl ketones are in abundance, along with alcohols, some aliphatic hydrocarbons, and other compound types. The C(3) methyl carbon remained attached to its original C(2) position in all catenated degradation products, and underwent no chemistry. However, products containing “non-catenated” carbons (i.e., not bonded to any other carbon atom) consisted entirely of a mix of C(3) and C(1). By examination of the labeling patterns, many products could be assigned to two successive chain scission events in close proximity, while others are clearly seen to arise from cleavage, followed by radical-radical recombination reactions. Interestingly, the former products (two chain scissions) are all found to have an odd number of carbon atoms along their chain, while the latter (scission followed by radical-radical reaction) all have an even number of carbons. An explanation of this odd/even phenomenon is provided in terms of the symmetry of the PP macromolecule.  相似文献   

5.
Multi‐walled carbon nanotube (MWCNT)/polypropylene (PP) composites were prepared by a micro melt mixing process. As‐prepared composites had relatively low electrical conductivity due to the disruption of MWCNT network by strong shear. The electrical conductivity jumped to high values throughout an annealing process above the melting temperature of PP. The significant enhancement of electrical conductivity was influenced by annealing time, temperature, and content of MWCNTs. In particular, molecular weight of PP played an important role in affecting the conductivity enhancement. The molecular weight of PP was varied from 190,000 to 340,000 to examine its effect on the electrical conductivity. By comparing the conductivity enhancement behavior of composites with different molecular weight PPs and observing the morphology evolution during annealing, it was found that reaggregation of MWCNTs and the subsequent formation of MWCNT network during annealing are the main reasons for the jump of electrical conductivity. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2010  相似文献   

6.
A headspace solid‐phase microextraction method coupled to GC–MS was successfully developed for the trace determination of formaldehyde in veterinary bacterial and human vaccines, and diphtheria–tetanus antigen. The formaldehyde was derivatized by means of the Hantzsch reaction prior to extraction and subsequent determination. Three different types of solid‐phase microextraction fibers, polar, and nonpolar poly(dimethylsiloxane) and polyethylene glycol were prepared by using a sol–gel technique. The effects of different parameters such as type of fiber coating, extraction time and temperature, desorption conditions, agitation rate, and salt effect were investigated. Under the optimized conditions, the detection limit of the method was 979 ng/L using the selected ion‐monitoring mode. The interday and intraday precisions of the developed method under the optimized conditions were below 13%, and the method shows linearity in the range of 1.75–800 μg/L with a correlation coefficient of 0.9963. The optimized method was applied to the determination of formaldehyde from some biological products. The results were satisfactory compared to the standard method.  相似文献   

7.
顶空固相微萃取-气相色谱质谱联用测定烷基铅的研究   总被引:5,自引:0,他引:5  
建立了顶空固相微萃取(HS SPME)与气相色谱 质谱(GC/MS)联用测定水样中四甲基铅和四乙基铅的方法,探讨了SPME萃取烷基铅的实验条件,并对GC/MS条件进行了优化。结果表明:四甲基铅和四乙基铅分别在5~1000ng/mL和1~500ng/mL范围内有良好的线性关系,检出限分别为四甲基铅5.19ng/mL,四乙基铅1.05ng/mL。方法用于合成水样分析,四甲基铅和四乙基铅的回收率在87.5%~110.6%之间,相对标准偏差在1.7%~6.5%之间。  相似文献   

8.
A novel sulfur-bearing hindered phenolic antioxidant with a molecular weight of 1305.9 (SAO) was successfully synthesized via thiol-acrylate Michael addition reaction and its structure was clarified by nuclear magnetic resonance (NMR) and fourier transform infrared spectra (FTIR). The short-term oxidation induction time (OIT) of polypropylene (PP) compounds obtained at 210 °C showed that the OIT value of SAO-containing PP was higher than that of PP using Chinox 1035 with a molecular weight of 642.9 as a stabilizer. Long-term accelerated thermal aging test of PP compounds in an air oven at 150 °C, however, exhibited that the aging resistance of SAO-stabilizing PP was inferior to that of 1035-containing PP, quite contrary to their respective short-term effect on PP stabilization. The possible reasons of this contradiction were discussed from the viewpoint of the antioxidants' molecular structure and the limitations of the OIT approach in lifetime prediction.  相似文献   

9.
A fiber‐coated polypyrrole–montmorillonite nanocomposite was prepared for solid‐phase microextraction. The fiber coating can be prepared easily; it is mechanically stable and exhibits relatively high thermal stability. The prepared fiber was evaluated for the extraction of some phenolic compounds from aqueous sample solutions by gas chromatography–mass spectrometry. The effects of the extraction and desorption parameters including extraction time, extraction temperature, stirring rate, ionic strength, pH and desorption temperature and time have been studied. At optimum conditions, the repeatability for one fiber (n = 5), expressed as % relative standard deviation was between 6.5 and 7.8% for the phenolic compounds. The detection limits for the studied phenolic compounds were between 0.05–1.3 ng/mL. The developed method offers the advantage of being simple to use, with shorter analysis time, lower cost, thermal stability of the fibers, and high relative recovery in comparison to conventional methods of analysis.  相似文献   

10.
建立了卷烟丝中烟草特有亚硝胺类化合物(TSNAs)的SPE-LC/MS/MS分析方法,可一次性对卷烟烟丝中4种TSNAs进行定量分析.该方法弥补了传统的烟丝中TSNAs分析方法样品处理步骤多,检出限高,适应范围窄等缺点.4种TSNA的回收率的范围在95.7%~99.2%之间;相对标准偏差均小于8%;方法检出限均低于1.0 ng/g.可应用于国内外各类型卷烟的分析.  相似文献   

11.
啤酒中N-亚硝胺的SPME-GC-MS分析   总被引:7,自引:0,他引:7  
研究了固相微萃取-气相色谱-质谱(SPME—GC—MS)联用方法检测啤酒中的N-亚硝基二乙胺(NDEA)、N-亚硝基吡咯烷(NPYR)、N-亚硝基二丁胺(NDBA),采用聚二甲基硅氧烷/二乙烯苯(PDMS/DVB)萃取头,对影响固相微萃取效率的萃取时间、搅拌速度以及萃取方式等进行了优化,在优化实验条件下,方法的线性范围在12.5~250μg/L之间,相关系数r为0.9971~0.9995,检出限分别为NDEA4.50μg/L,NPYR8.99μg/L,NDBA2.27μg/L,NDBA回收率为86%~96%,相对标准偏差6.296~8.996,该法简化了前处理步骤,快速、方便.结果满意。  相似文献   

12.
The analysis of samples contaminated by organic compounds is an important aspect of environmental monitoring. Because of the complex nature of these samples, isolating target organic compounds from their matrices is a major challenge. A new isolation technique, solid phase microextraction, or SPME, has recently been developed in our laboratory. This technique combines the extraction and concentration processes into one step; a fused silica fiber coated with a polymer is used to extract analytes and transfer them into a GC injector for thermal desorption and analysis. It is simple, rapid, inexpensive, completely solvent-free, and easily automated. To minimize matrix interferences in environmental samples, SPME can be used to extract analytes from the headspace above the sample. The combination of headspace sampling with SPME separates volatile and semi-volatile analytes from non-volatile compounds, thus greatly reducing the interferences from non-target compounds. This paper reports the use of headspace SPME to isolate volatile organic compounds from various matrices such as water, sand, clay, and sludge. By use of the technique, benzene, toluene, ethyl-benzene, and xylene isomers (commonly known as BTEX), and volatile chlorinated compounds can be efficiently isolated from various matrices with good precision and low limits of detection. This study has found that the sensitivity of the method can be greatly improved by the addition of salt to water samples, water to soil samples, or by heating. Headspace SPME can also be used to sample semi-volatile compounds, such as PAHs, from complex matrices.  相似文献   

13.
14.
A method for the extraction and determination of methylmercury (MeHg) in solid matrices is presented. Combining the advantages of two extraction techniques—subcritical water extraction (subWE) and solid‐phase microextraction (SPME)—selective separation of MeHg from soils is possible. The procedure is based on extraction with subcritical water without using organic solvents, followed by in situ aqueous‐phase derivatization with sodium tetraethylborate and headspace SPME with a silica fiber coated with poly(dimethylsiloxane). The optimization of the extraction parameters is described. The identification and quantification of the extracted alkylmercury compounds from spiked soil samples is performed by GC–MS after thermal desorption. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

15.
《European Polymer Journal》2003,39(1):157-163
The subject of this work is the thermal behaviour of polypropylene/talc composites whose interface has been modified by atactic polypropylenes containing different numbers of succinyl fluorescein grafted groups. The interface modifiers used here were previously obtained in our laboratories by a two-step chemical modification of the melt of a by-product (atactic polypropylene) of industrial polymerisation reactors. The variations in interface activity caused by replacing a small amount of the polypropylene matrix in the composite by succinyl fluorescein grafted atactic polypropylene were clearly detected by differential scanning calorimetry as thermal responses. These studies show that interface agents are preferably located in the amorphous phase of the system. A correlation between the crystalline content of the polymer component and the degree of grafting of the interface agent is also established. Further, a relationship between the thermal behaviour and the mechanical properties of the system seems to emerge.  相似文献   

16.
Four different miniaturized methodologies were developed and applied to the analysis of 11 UV filters in sand samples. These approaches were based on ultrasound and vortex extractions, on‐column lixiviation, and ultrasound extraction followed by solid‐phase microextraction. Gas chromatography with tandem mass spectrometry was used for quantitative analysis. The analytical performance provided by the four methods was evaluated in terms of linearity, accuracy, precision, and limits of quantification. Lixiviation was discarded since it provided the lowest recoveries and the highest limits of quantification. In contrast, ultrasound and vortex extractions, and ultrasound extraction followed by solid‐phase microextraction were suitable, with recoveries in general >85% and limits of quantification at the low ng/g level. Moreover, ultrasound extraction followed by solid‐phase microextraction allowed using external calibration with aqueous standards and it provided higher sensitivity, with limits of quantification in general one order of magnitude lower than those achieved with the other techniques. The methodologies were applied for the analysis of four marine sand samples, and the results were statistically compared performing an analysis of variance. Eight out of the eleven target UV filters were detected. Octocrylene was found at very high concentrations (up to 1000 ng/g) followed by ethylhexyl salicylate, 4‐methylbenzylidene camphor, homosalate, and 2‐ethylhexyl methoxycinnamate.  相似文献   

17.
A sensitive and efficient solid-phase microextraction (SPME) method for the determination of organophosphorous (OPPs) and pyrethroid pesticides (Pyrs) in aquaculture-seawater samples by using GC with MS/MS (GC-MS/MS) was developed. Dichlorvos and chlorpyrifos (OPPs); permethrin, alpha-cypermethrin and deltamethrin (Pyrs) were selected according to their use as chemotherapeutants in the aquaculture industry. Different parameters affecting extraction efficiency such as fibre coating, agitation, pH and extraction time profiles were investigated. An experimental central composite design (alpha = 1) and desirability functions were used for the simultaneous optimization of extraction temperature and sample volume. Finally, a method based on direct SPME in 40 min at 75 degrees C using 100-microm-thick poly(dimethyl)siloxane (PDMS) fibre and 20 mL of sample volume is proposed. The method was validated, exhibiting good linearity, precision and accuracy parameters with picogram per millilitre LODs. The proposed methodology was applied to determine the ultratrace levels of OPPs and Pyrs in aquaculture-seawater samples by the standard addition approach, which proved to be reliable and sensitive, in addition to requiring only small amounts of sample.  相似文献   

18.
Recently the connection between oxidative stress and various diseases, including cancer and Alzheimer's, attracts notice as a pathway suitable for diagnostic purposes. 8‐Oxo‐deoxyguanosine and 8‐oxo‐deoxyadenosine produced from the interaction of reactive oxygen species with DNA become prominent as biomarkers. Several methods have been developed for their determination in biofluids, including solid‐phase extraction and enzyme‐linked immunosorbent assays. However, still, there is a need for reliable and fast analytical methods. In this context, solid‐phase microextraction offers many advantages such as flexibility in geometry and applicable sample volume, as well as high adaptability to high‐throughput sampling. In this study, a solid‐phase microextraction method was developed for the determination of 8‐oxo‐deoxyguanosine and 8‐oxo‐deoxyadenosine in biofluids. The extractive phase of solid‐phase microextraction consisted of hydrophilic–lipophilic balanced polymeric particles. In order to develop a solid‐phase microextraction method suitable for the determination of the analytes in saliva and urine, several parameters, including desorption solvent, desorption time, sample pH, and ionic strength, were scrutinized. Analytical figures of merit indicated that the developed method provides reasonable interday and intraday precisions (<15% in both biofluids) with acceptable accuracy. The method provides a limit of quantification for both biomarkers at 5.0 and 10.0 ng/mL levels in saliva and urine matrices, respectively.  相似文献   

19.
Chemotherapy used as a treatment against lung cancer has influence on metabolic processes occurring in healthy cells. The changes of biochemical pathways proceeded inside cells might be observed in expired air. In the experiment, breath analysis was carried out before and after anticancer therapy. Expired air samples were collected from 22 patients with a biopsy confirmed lung cancer. Volatile organic compounds present in breath were analyzed by gas chromatography/mass spectrometry. For enrichment of analytes solid‐phase microextraction technique was applied. Eight fibers covered by different sorbents were tested. Carboxen‐polydimethylsiloxane fiber revealed the highest extraction efficiency in relation to analytes in breath. The data showed that cytostatic drugs increase the concentration of acetone and isoprene in the breath collected after chemotherapy. Volatile metabolites of administrated drugs were not identified in expired air.  相似文献   

20.
A high resolution liquid chromatographic method is described for determination of low molecular weight (LMW) aliphatic amines in environmental waters. The analytes after isolation are derivatized by fluram and separated with isocratic elution on octyl (C8) column, followed by fluorimetric detection in 395/495 nm. Different isolation procedures such as octadecylsilane (ODS) and strong cation exchanger (SCX) solid phase extraction (SPE) cartridges and Amberlite CG-120 resin were evaluated. The quantitative characteristics such as recovery, linear dynamic range, correlation coefficient, limit of detection (LOD), and relative standard deviation (RSD) are presented. Using this method, aliphatic amines were analyzed in rain and tap water as well as in waste water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号