首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Uslu  Bengi  &#;zden  Tugba 《Chromatographia》2013,76(21):1487-1494

High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.

  相似文献   

2.

An LC-DAD method was developed for determination of lobeline from in vitro and in vivo cultures of Lobelia inflata. Samples were extracted with 0.1 N HCl–acetonitrile (1:1, v/v), and purified by solid-phase extraction. Optimized conditions resulted in high recovery. LC separations were performed on an Eurosphere C8 reversed-phase column using 30:70 (v/v) acetonitrile–0.1% trifluoroacetic acid as a mobile phase. Quantitative determination of lobeline was performed by external standard method at 250 nm, in the range of 2.4–80 μg mL−1. Validation studies proved that the repeatability of the method was good and the recovery was satisfactory. In vitro organized cultures contained considerable amount of lobeline (herb: 175 μg g−1, root: 100 μg g−1). When these cultures were transplanted into the open field, the lobeline content increased significantly (herb: 323 μg g−1, root: 833 μg g−1). Plants obtained from seed propagation contained 382 μg g−1 lobeline in the herb. For direct characterization of di-substituted piperidine alkaloids in extracts of L. inflata, tandem mass spectrometric method was developed using electrospray ionization. Analysis was performed in the positive ion mode on a triple quadropole LC–MS system. LC separations were achieved on Eurosphere C8 column with a modified mobile phase (acetonitrile–30 mM ammonium formate, pH 2.80) to ensure proper molecular ionization. The identification and structural elucidation of the alkaloids were performed by comparing their changes in molecular mass (ΔM), full-scan MS–MS spectra with those of lobeline, norlobelanine and lobelanidine. These alkaloids and ten other derivatives were identified in the plant extracts. Three piperidine alkaloids were reported in L. inflata for the first time.

  相似文献   

3.

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08–5.70 μg mL−1 (= 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 μg mL−1, respectively.

  相似文献   

4.

This paper describes the validation of an isocratic LC method for the assay of linezolid in tablets. Validation parameters such as linearity, precision, accuracy, specificity, limit of detection, limit of quantitation and robustness were determined. LC was carried out by reversed phase technique on an RP-18 column with a mobile phase composed of 1% acetic acid:methanol:acetonitrile (50:25:25, v/v/v). Linezolid and your combination drug product were exposed to acid, base, oxidation, dry heat and photolytic stress conditions. A linear response (r > 0.9999) was observed in the range of 8.0–20.0 μg mL−1. The retention time of linezolid was 4.6 min. The method showed good recoveries and intra- and inter-day relative standard deviations were less than 1.0%. The LOD and LOQ were 0.21 and 0.63 μg mL−1, respectively. The developed LC method for determination of related substances and assay determination of linezolid can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of linezolid.

  相似文献   

5.
Liu  Yongmei  Liao  Mengya  Zhang  Cuiwei  Bai  Yuli  Song  Honglian  Zhang  Yiwen  Wang  Xin 《Chromatographia》2015,78(23):1485-1489

A precise and sensitive LC method for the determination of repertaxin enantiomeric purity has been developed and validated. Baseline separation with a resolution higher than 2.0 was accomplished within 20 min using a Chiralpak AD-H column (250 × 4.6 mm; particle size 5 μm) and n-hexane:2-propanol (90:10 v/v) as mobile phase at a flow rate of 1 mL min−1. Eluted analytes were monitored by UV detection at 260 nm. The effects of mobile phase composition, temperature and flow rate on enantiomeric selectivity and on resolution of enantiomers were investigated. Calibration curves were plotted within the concentration range between 0.002 and 1.0 mg mL−1 (n = 3), and relative standard deviation (RSD) of the inter-batch assay and intra-batch assay was less than 1.27 and 1.16 %. LOD and LOQ for repertaxin were 0.65 and 2.19 μg mL−1; those for its enantiomer were 0.70 and 2.34 μg mL−1, respectively. The method was evaluated and validated by analysis of bulk samples of repertaxin of different enantiomeric purity. It was demonstrated that the method was accurate, robust, and sensitive, and enabled practical analysis of real samples.

  相似文献   

6.

A simple, rapid, and stability-indicating reversed-phase high-performance liquid chromatographic (LC) method for analysis for dutasteride has been successfully developed. Chromatography was performed on a 150 mm × 4.6 mm C18 column with acetonitrile–water 60:40 (v/v) as isocratic mobile phase at 1.0 mL min−1. Ultraviolet detection of dutasteride was at 210 nm. Its retention time was approximately 10 min and its peak was symmetrical. Response was a linear function of concentration over the range 0.2–1 μg mL−1 (R 2 = 0.997) and the limits of detection and quantitation were was 0.05 and 0.10 μg mL−1, respectively. The method was validated for linearity, precision, repeatability, sensitivity, and selectivity. Selectivity was validated by subjecting dutasteride stock solution to photolytic, acidic, basic, oxidative, and thermal degradation. The peaks from the degradation products did not interfere with that from dutasteride. The method was used to quantify dutasteride in pharmaceutical preparations.

  相似文献   

7.

A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 μg mL−1. The RSD values (0.7–4.3%) and percentage recovery (88.1–109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 μg mL−1. Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.

  相似文献   

8.
Yang  Xiao-ming  Zhang  Xiu-li  Chen  Yong-chang  Liu  Fang 《Chromatographia》2009,69(5-6):593-596

A sensitive and simple LC method for the quantification of ginkgolic acids in mice plasma has been developed. Following acetonitrile deproteinization, samples were separated on a SinoChrom ODS-AP C18 column. The mobile phase was 3% (v/v) acetic acid water solution–methanol (8:92, v/v) at a flow rate of 1.0 mL min−1. Detection was at 310 nm. Calibration curve was linear over the range of 0.25–50 μg mL−1 with intra- and inter-day precisions (RSD%) of less than 9.5%. The extraction recovery ranged from 87.0 to 90.2% (RSD 2.4–6.4%) for ginkgolic acids. The method was successfully applied to the pharmacokinetic study of ginkgolic acids in mice after oral dosing of 1.0 g kg−1.

  相似文献   

9.

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min−1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL−1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.

  相似文献   

10.
Lu  Yingnian  Wu  Kefeng  Liang  Nianci  Chen  George G. 《Chromatographia》2009,70(11):1599-1603

ent-11α-Hydroxy-15-oxo-kaur-16-en-19-oic acid (5F), a diterpenoid isolated from the Chinese herb Pteris semipinnata L, has been suggested to show antitumor properties. A simple and sensitive LC method was developed for the determination of 5F in rabbit plasma. The method involved liquid–liquid extraction using ethyl acetate under acidic conditions using naproxen as an internal standard. Separations were performed on a reversed-phase column with a mixture of 1% (v/v) glacial acetic acid and methanol (45:55, v/v) as mobile phase and UV detection was utilized at 242 nm. The calibration plot was linear in the range 0.20–10.0 μg mL−1 (correlation coefficients r 2 > 0.998). The detection limit was 0.20 μg mL−1, mean extraction recovery was above 82%, intra-day precision of the method was less than 6.4%, and inter-day precision was better than 8.7%, respectively. The validated assay was found to be suitable for the pharmacokinetic study of 5F in rabbits.

  相似文献   

11.
Aksoy  B.  K&#;&#;&#;kg&#;zel  &#;.  Rollas  S. 《Chromatographia》2007,66(1):57-63

The objective of the current study was the development and subsequent validation of a simple, sensitive, precise and stability-indicating reversed-phase HPLC method for the determination of ciprofloxacin HCl in pharmaceutical dosage forms in the presence of its potential impurities. The chromatographic separation of ciprofloxacin HCl and its related compounds was achieved on an Inertsil ODS3 column using UV detection. The optimized mobile phase consisted of phosphoric acid solution: acetonitril. The proposed method provided linear responses within the concentration range 250–750 μg mL−1 for ciprofloxacin HCl and 0.5–1.5 μg mL−1 for its related compounds. LOD and LOQ values for the active substance were 5.159 and 15.632 μg mL−1, respectively. Correlation coefficients (r) of the regression equations for the impurities were greater than 0.99 in all cases. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 1% in all instances. No interference from any components of pharmaceutical dosage forms or degradation products was observed.

  相似文献   

12.
Chen  Jing  Gu  Jingkai  Zhao  Rui  Dai  Ronghua  Wang  Jinhui 《Chromatographia》2009,69(3-4):361-363

A new method was performed using on-line coupling of nonchiral reversed-phase liquid chromatography (RP-LC) to circular dichroism (CD) spectroscopy for simultaneous determination of artemisinin and arteannuin B in crude plant extracts of Artemisia annua. Analysis was carried out on an LC–CD system equipped with an Agilent TC-C18 column (4.6 mm I.D. × 200 mm L, 5 μm) using gradient of acetonitrile. The method was validated to be practicable and reliable at alterable wavelength in the ranges of 220–420 nm as desired. LOD and LOQ of artemisinin and arteannuin B were 0.08, 0.26 and 0.31, 1.02 μg mL−1, respectively. It was more sensitive than conventional LC–UV and comparatively cheaper than LC–MS in analysis of TCM.

  相似文献   

13.

Praziquantel (PZQ) is a highly lipophilic drug with low aqueous solubility. Despite this, it is well absorbed from the gastrointestinal tract. In this study, a simple LC method was developed and validated, in order to monitor the concentration of PZQ in TC-199 buffer in vitro, in the rat everted gut sac absorption model. PZQ was analyzed by a reversed-phase LC method with an isocratic mobile phase containing acetonitrile and water in the proportions 45:55. The flow-rate was 1 mL min−1 and PZQ was determined by measuring absorbance at 215 nm, at 25 °C. The method was found to be specific, as none of the components of TC-199 or intestinal sac artefacts interfered with the drug peak. Recovery was within acceptable statistical limits. The limit of detection was 0.54 μg mL−1 and the limit of quantitation was 1.63 μg mL−1. The calibration curve was found to be linear in the concentration range of 10–90 μg mL−1 PZQ. The proposed method was found to be rapid and selective and hence can be applied in the monitoring of the absorption of PZQ in in vitro everted gut sac absorption studies.

  相似文献   

14.
He  Hui  Chen  Xi J.  Wang  Guang Ji 《Chromatographia》2008,67(11):1013-1016

A high-performance liquid chromatography-electrospray ionization-mass spectromentry (LC–ESI–MS) method has been developed for the determination of picroside II in dog plasma. Plasma samples were deproteinated with acetonitrile and a Hypersil ODS2 column was used with a mobile phase consisted of methanol-water. The determination was validated in the concentration range of 0.10–50 μg mL−1 using 50 μL of plasma. The method was successfully applied to a pharmacokinetic study of picroside II.

  相似文献   

15.
Xiong  Xunyu  Zhang  Qunzheng  Xiong  Fengmei  Tang  Yuhai 《Chromatographia》2008,67(11):929-934

A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL−1 for ibuprofen, 0.001–1.0 μg mL−1 for naproxen, and 0.01–10.0 μg mL−1 for fenbufen. The limits of detection were 0.5 ng mL−1 for ibuprofen, 0.05 ng mL−1 for naproxen and 0.5 ng mL−1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.

  相似文献   

16.
Bengi Uslu  Tugba Özden 《Chromatographia》2013,76(21-22):1487-1494
High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL?1 of ENL, 0.260–399 μg mL?1 of HCZ for HPLC system and 0.270–399 μg mL?1 of ENL and 0.065–249 μg mL?1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL?1 and 31.477 ng mL?1 for HCZ, 2.804 ng mL?1 for ENL and 2.943 ng mL?1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.  相似文献   

17.
18.
Zhang  Chunni  Sun  Xinguang  Zhao  Yang  Zhang  Jie  Ma  Fengxia  Long  Zhen  Liang  Lina  Wang  Yingzi  Ma  Baiping 《Chromatographia》2016,79(19):1381-1386

In this work, a simple and rapid high-performance liquid chromatography coupled with charged aerosol detector (HPLC-CAD) method was first developed for the quantitation of toosendanin, the major constituent of the dried fruit of Melia toosendan Sieb. Et Zucc. Samples were well separated on an Agilent ZOBAX SB C18 column (4.6 mm × 250 mm, 5 μm) by isocratic elution using 33 % acetonitrile and 67 % water containing 0.1 % formic acid (v/v) at the flow rate of 1.0 mL min−1. The nitrogen inlet pressure of the charged aerosol detector (CAD) was 35 psi, and the nebulizer chamber temperature was 35 °C. The established method was well validated. Satisfactory linearity was achieved (r 2 > 0.9997) in a relatively wide concentration range (5–500 μg mL−1). The intra- and inter-day precisions, repeatability, and stability of the method were good with relative standard deviations (RSDs) of 1.05, 2.23, 2.39, and 2.03 %, respectively. The method also showed excellent accuracy with recovery rates of 97.42–101.87 %. Particularly, CAD showed much better sensitivity (LOQ 4 μg mL−1) than evaporative light scattering detector (LOQ 100 μg mL−1) for toosendanin’s determination. The established method was further applied in the quantitation of toosendanin in 39 batches of raw and stir-fried toosendan fructus. The HPLC-CAD method was rapid and accurate, and could be used for the routine analysis and quality control of toosendan fructus and its preparations.

  相似文献   

19.

Taurine is an amino acid which is not incorporated into proteins but found in the cytosol of many mammalian cells, in high concentrations (2–30 mM). Increase in plasma taurine concentration has already been reported after surgical trauma, X-radiation, muscle necrosis, carbon tetrachloride-induced liver damage, and paracetamol overdose. Plasma taurine concentration was measured using LC with fluorescence detection following derivatization by o-phtalaldehyde plus 3-mercapto-propionic acid and α-aminobutyric acid as internal standard. Under these conditions the retention time of taurine was 10 min. This method was sensitive enough, to quantify 150 pg mL−1 and detect 50 pg mL−1 of taurine ranging normally between 65 and 179 mmol L−1 (8–22 μg mL−1). The validated method allowed simple determination of human plasma taurine in pharmacokinetic and biomarker studies.

  相似文献   

20.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号