1.
The off-line coupling of high-performance anion-exchange chromatography (HPAEC) to electrospray ionisation/ion trap mass spectrometry (ESI-ITMS) is described. The Dionex carbohydrate membrane desalter (CMD) has been assessed as an on-line chromatographic desalting system to remove the high sodium concentration necessary for the HPAEC separation of partially methyl-esterified oligogalacturonides. The developed HPAEC configuration proved to be suitable for indirect coupling with ESI-ITMS. This paper provides some interesting features of positive- and negative-ion multistage tandem mass spectrometry (MS(n)) analysis of these acidic oligosaccharides. The spectra acquired in both negative- and positive-ion modes show characteristic fragment ions resulting from glycosidic bond and cross-ring cleavages. Some new mass spectrometric fragmentation routes are also described. The positive-ion mode gave more complex spectra but was as informative as the negative-ion mode. ESI-ITMS was revealed to be, as previously reported from direct use on an unseparated enzymatic digest, a powerful sequencing technique for the determination of linkage type and the methyl ester distribution of partially methyl-esterified oligogalacturonides. Moreover, unlike matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-ToF MS), it gives valuable information on the elution behaviour of these oligomers in relation to their structure, namely the HPAEC co-elution of isomeric structures.  相似文献   

2.
We present an evaluation of HPLC-based analytical tools for the simultaneous analysis of native and oxidized cello-oligosaccharides, which are products of enzymatic cellulose degradation. Whereas cello-oligosaccharides arise from cellulose depolymerization by glycoside hydrolases, oxidized cello-oligosaccharides are produced by cellobiose dehydrogenase and the recently identified copper dependent lytic polysaccharide monooxygenases (LPMOs) currently classified as CBM33 and GH61. The latter enzymes are wide-spread and expected to play crucial roles in further development of efficient enzyme technology for biomass conversion. Three HPLC approaches with well documented performance in the field of oligosaccharide analysis have been investigated: high-performance anion-exchange chromatography (HPAEC), hydrophilic interaction chromatography (HILIC) and porous graphitized carbon liquid chromatography (PGC-LC). HPAEC with pulsed amperometric detection (PAD) was superior for analysis of oxidized oligosaccharides, combining the best separation with superior sensitivity for oligosaccharide species with a degree of polymerization (DP) ranging from 1 to 10. Furthermore, the HPAEC method can be optimized for operation in a high-throughput manner (run time 10 min). Both PGC-LC and HILIC allow reasonable run times (41 and 25 min, respectively), with acceptable separation, but suffer from poor sensitivity compared to HPAEC-PAD. On the other hand, PGC-LC and HILIC benefit from being fully compatible with online mass spectrometry. Using an LC–MS setup, these methods will deliver much better sensitivity than what can be obtained with conventional detectors such as ultraviolet-, charged aerosol-, or evaporative light scattering and may reach sensitivities similar to or even better than what is obtained in HPAEC-PAD. Pure oxidized cello-oligosaccharide standards, ranging from DP2 to DP5, were obtained by semi-preparative PGC and characterized by MS and NMR analysis.  相似文献   

3.
A versatile liquid chromatographic platform has been developed for analysing underivatized carbohydrates using high performance anion exchange chromatography (HPAEC) followed by an inert PEEK splitter that splits the effluent to the integrated pulsed amperometric detector (IPAD) and to an on-line single quadrupole mass spectrometer (MS). Common eluents for HPAEC such as sodium hydroxide and sodium acetate are beneficial for the amperometric detection but not compatible with electrospray ionisation (ESI). Therefore a membrane-desalting device was installed after the splitter and prior to the ESI interface converting sodium hydroxide into water and sodium acetate into acetic acid. To enhance the sensitivity for the MS detection, 0.5 mmol/l lithium chloride was added after the membrane desalter to form lithium adducts of the carbohydrates. To compare sensitivity of IPAD and MS detection glucose, fructose, and sucrose were used as analytes. A calibration with external standards from 2.5 to 1000 pmole was performed showing a linear range over three orders of magnitude. Minimum detection limits (MDL) with IPAD were determined at 5 pmole levels for glucose to be 0.12 pmole, fructose 0.22 pmole and sucrose 0.11 pmole. With MS detection in the selected ion mode (SIM) the lithium adducts of the carbohydrates were detected obtaining MDL's for glucose of 1.49 pmole, fructose 1.19 pmole, and sucrose 0.36 pmole showing that under these conditions IPAD is 3-10 times more sensitive for those carbohydrates. The applicability of the method was demonstrated analysing carbohydrates in real world samples such as chicory inulin where polyfructans up to a molecular mass of 7000 g/mol were detected as quadrupoly charged lithium adducts. Furthermore mono-, di-, tri-, and oligosaccharides were detected in chicory coffee, honey and beer samples.  相似文献   

4.
丁俊  蒋丽  冯钰锜 《色谱》2014,32(10):1094-1103
油菜素甾醇是一类重要的植物激素,对植物的生长发育过程起显著调节作用。已报道的油菜素甾醇分析方法存在样品前处理过程复杂和灵敏度低等问题。本研究采用C18 PEEK管填充柱为富集柱,以4-N,N-二甲氨基苯硼酸为衍生试剂,搭建了基于双泵-双六通阀的在线管内固相微萃取-超高效液相色谱-串联质谱(UPLC-MS/MS)联用系统,对油菜素甾醇进行在线富集和原位衍生,实现植物组织中内源性油菜素甾醇的自动化分析。该系统程序化地控制了油菜素甾醇的进样、萃取、衍生、分离和检测过程,有效简化前处理过程,节省人力;在线富集步骤实现了样品溶液大体积进样,提高样品利用率;原位衍生改善了油菜素甾醇电喷雾的离子化效率,使油菜素甾醇的电喷雾质谱检出限降低至pg/mL。该系统可在300 mg鲜重植物组织中检测到内源性油菜素甾醇,已成功用于水稻、油菜中多种油菜素甾醇的定量分析。  相似文献   

5.
High-pressure liquid chromatography-diode array detector-electrospray ionisation/ion trap mass spectrometry (HPLC-DAD-ESI/MS(n)) analyses carried out in red wine fractions revealed the existence of dimeric anthocyanins (A-A(+)), previously detected in grape skin, and allowed the detection and identification, for the first time, of other derived oligomers. The structure of these compounds was characterised according to their MS(n)(n = 1-4) fragmentation patterns. The newly detected oligomers consisted of a flavanol, (epi)catechin or (epi)gallocatechin, linked through its C(4) position to the nucleophilic positions of the upper unit of a dimeric anthocyanin (F-A-A(+)). All the compounds contained malvidin as one of the anthocyanin subunits, whereas the other anthocyanin moiety could be either delphinidin, cyanidin, petunidin, peonidin or malvidin. With the fractionation method employed, the dimeric anthocyanins eluted in the same fractions as the monomeric anthocyanins. However, the new F-A-A(+) oligomers were found in the same fractions as F-A(+) dimers, which might indicate a structural similarity between both types of compounds. ESI/MS(n) analyses, coupled or not to HPLC, showed to be a useful and powerful tool for detecting and identifying these oligomers in wines, which usually elute from reversed-phase columns as humps and/or are overlapped by the peaks of other compounds. The detection of these oligomeric pigments in wine has provided more information about the complex pigments responsible for the elevation of the base line observed in the chromatograms of wines and has also revealed that oligomeric anthocyanins can take part in the reactions usually undergone by monomeric anthocyanins.  相似文献   

6.
Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS2) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS2. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities.  相似文献   

7.
The analysis of malto-oligosaccharides by MALDI-TOF mass spectrometry (MS), capillary electrophoresis (CE) and anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) is described. Appropriate methods were developed which enabled the resolution of the oligosaccharides and quantification of the peak areas. It could be shown that each technique provided a different distribution profile of the maltodextrins. Using MALDI-TOF MS signals of higher molecular weight oligomers were enhanced while low molecular weight analogues were discriminated. Thus, the response factor depends on the degree of polymerization (DP) of the carbohydrates. Homologues up to DP-15 could be detected. Analysis of the maltodextrins by CE was accomplished by derivatization of the sugars with 4-aminobenzonitrile (ABN) and 8-aminonaphthalene-1,3,6-trisulfonic acid, respectively. By using the latter reagent oligosaccharides up to DP-13 were detected while derivatization with ABN allowed detection up to DP-9. The molecular weight distribution obtained by both approaches were the same. HPAEC-PAD enabled the determination of oligomers up to DP-9. The distribution obtained by this technique showed somewhat lower signals of the small homologues than those found by CE while the opposite held for higher molecular weight compounds. Hydrolysis of the carbohydrates by the derivatization reaction prior to CE analysis, which increased the proportion of low molecular weight homologues, may account for these findings. Receiverd: 28 August 1997 / Revised: 24 November 1997 / Accepted: 25 November 1997  相似文献   

8.
Synthetic polymers are naturally mixtures of homologs, even in pure form. More complexity is introduced by the presence of different comonomers, end groups and/or macromolecular architectures. The analysis of such systems is substantially facilitated by interfacing mass spectrometry (MS), which disperses based on mass, with an additional level of separation involving either interactive liquid chromatography (LC) or ion mobility (IM) spectrometry, both of which are readily coupled online with electrospray ionization and MS detection. IM-MS separates in the gas phase, post-ionization and, therefore, is ideally suitable for labile and reactive polymers. Its usefulness is illustrated with the characterization of non-covalent siloxane-saccharide complexes, metallosupramolecular assemblies and an air- and moisture-sensitive inorganic polymer, poly(dichlorophosphazene). Conversely, LC-MS which separates in solution phase, before ionization, is most effective for the analysis of polymeric mixtures whose components differ in polarity. Interactive LC conditions can be optimized to disperse by the content of hydrophobic units, as is demonstrated for amphiphilic polyether copolymers and sugar-based nonionic surfactant blends. Both LC-MS and IM-MS can be extended into a third dimension by tandem mass spectrometry (MS(2)) studies on select oligomers, in order to obtain insight into individual end groups and isomeric architectures, comonomer sequences and degree of substitution, for example, by hydrophobic functionalities.  相似文献   

9.
A high-performance size-exclusion chromatography-evaporative light scattering detector method was used to separate, detect and quantify galacturonic acid (GA) oligomers. In 40 mM acetic acid GA monomer, dimer and trimer could be separated with baseline resolution but polygalacturonic acid (PGA) precipitated and could not be eluted from the column. An NH4OAc, pH 3.7, buffer was developed as the eluent which separated GA oligomers as well as PGA and pectin without precipitation. Linear calibration curves for mono-, di- and tri-GA were produced with this buffer which could be used to estimate masses of tetra-, penta- and hexa-GA, as well as 19mer and 20mer.  相似文献   

10.
A new method for the identification of oligosaccharides obtained by enzymatic digestion of hyaluronic acid (HA) with bacterial hyaluronidase (HA lyase, E.C. 4.2.2.1, from Streptococcus agalactiae) using online capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS) is presented. A fused-silica capillary coated with polyacrylamide was used with a 40 mM ammonium acetate buffer at pH 9.0 and a separation voltage of +30 kV applied to the inlet. Separation was achieved for oligosaccharides containing 4-16 monomers. The migration behavior follows the chain length of the oligomers, regardless of charge state. However, no linear relationship was found for the relation between mobility and chain length. Using an ion trap mass analyzer, complementary structural information was obtained by MS/MS and MS(n) experiments.  相似文献   

11.
The analysis of malto-oligosaccharides by MALDI-TOF mass spectrometry (MS), capillary electrophoresis (CE) and anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) is described. Appropriate methods were developed which enabled the resolution of the oligosaccharides and quantification of the peak areas. It could be shown that each technique provided a different distribution profile of the maltodextrins. Using MALDI-TOF MS signals of higher molecular weight oligomers were enhanced while low molecular weight analogues were discriminated. Thus, the response factor depends on the degree of polymerization (DP) of the carbohydrates. Homologues up to DP-15 could be detected. Analysis of the maltodextrins by CE was accomplished by derivatization of the sugars with 4-aminobenzonitrile (ABN) and 8-aminonaphthalene-1,3,6-trisulfonic acid, respectively. By using the latter reagent oligosaccharides up to DP-13 were detected while derivatization with ABN allowed detection up to DP-9. The molecular weight distribution obtained by both approaches were the same. HPAEC-PAD enabled the determination of oligomers up to DP-9. The distribution obtained by this technique showed somewhat lower signals of the small homologues than those found by CE while the opposite held for higher molecular weight compounds. Hydrolysis of the carbohydrates by the derivatization reaction prior to CE analysis, which increased the proportion of low molecular weight homologues, may account for these findings.  相似文献   

12.
Silicone oil samples were characterized by supercritical fluid chromatography (SFC), matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI--TOF MS), and their off-line combination. SFC was used to separate samples of silicone oils on micropacked capillary columns. The fractions for the identification studies were obtained from SFC runs at defined time intervals, when the restrictor was pulled out from the chromatographic flame ionization detector (FID) and inserted into a glass vial with acetone. MALDI--TOF MS was used for the identification of individual oligomers in the fractions separated. The molecular mass distributions determined based on SFC and MALDI--TOF MS measurements were compared. From this comparison, it follows that the results are in good agreement. However, certain differences were observed: MALDI--TOF MS was capable of detecting somewhat larger oligomers than the SFC-FID, but the lower molecular mass oligomers were not present in the MALDI spectra. Differences in the region of lower molecular masses can be explained by evaporation of the more volatile low molecular mass oligomers resulting from heating of the sample during the MALDI--TOF MS measurements as a result of the absorption of the laser shot energy. The fact that no high mass discrimination effects of the MALDI--TOF MS measurements, compared with SFC, were observed is very promising for further applications of MALDI--TOF MS in characterizing synthetic polymers of moderate polydispersity.  相似文献   

13.
Pre-column derivatization allowed stacking amino acid enantiomers on C18 reversed-phase micro extraction columns, thus facilitating sample loading in capillary HPLC/tandem mass spectrometry. Two tagging reagents, i.e. 7-fluoro-4-nitrobenzoxadiazole (NBD-F) and 1-fluoro-2,4-dinitrobenzene (DNB-F) were evaluated. Both of them reacted readily with amino acids at an elevated temperature, resulting in derivatives that were effectively stacked and suitable for a sensitive MS/MS detection as well. Separation of the tagged enantiomers on a teicoplanin chiral stationary phase (CSP) with mobile phases compatible with MS detection was investigated. NBD-amino acid enantiomers (12 pairs) tested were all base-line resolved. However, the efforts to separate DNB-F tagged amino acid enantiomers on this CSP were not successful. Separation conditions including pH, organic modifiers, and column dimension were studied. All the NBD-amino acids studied could be sensitively detected by MS/MS detection set in the negative ion mode, but only a few including NBD-Asp, BND-Glu, NBD-Ser, and NBD-Thr were detected in the positive ion mode. Thus, the selectivity for enantiomeric determination of excitatory amino acids (e.g. Asp and Glu) was further improved by choosing MS/MS detection in the positive ion mode.  相似文献   

14.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) system with an online dual-loop cleanup device was developed for simultaneous quantitation of the urinary benzene exposure biomarkers trans,trans-muconic acid (ttMA) and S-phenylmercapturic acid (SPMA). The cleanup device was constructed from an autosampler, two electrically operated two-position switching valves, a reversed-phase C18 trap cartridge, a 200-microL loop, and two solvent-delivery pumps. The device was interfaced directly with a triple-quadrupole mass spectrometer and fully controlled by computer software and hardware. Because isotope dilution by introducing 13C-labeled ttMA and SPMA as internal standards was employed, the precision of the analytical system was high (for ttMA, intra- and inter-day CV values ranged from 3.82-4.53%; for SPMA, 2.13-7.06%). The calibration curves obtained using human urine spiked with ttMA were linear from 15.6-4000 microg/L (R = 0.9998) and SPMA at concentrations from 0.78-200 microg/L (R = 0.9993). The method detection limit (MDL) for SPMA was 0.23 microg/L. The MDL of ttMA could not be determined accurately because of unavailability of an appropriate blank urine matrix, but was estimated to be lower than 7.43 microg/L. Without tedious manual sample cleanup procedures the analytical system is fully automated and is therefore useful for high-throughput simultaneous determination of urinary ttMA and SPMA. The sample throughput is roughly 100 samples per day. With the selectivity and the sensitivity provided by MS/MS detection, the analytical system can be used for large-scale monitoring of environmental or occupational exposure of humans to benzene.  相似文献   

15.
Poly(ester amide)s from dimethyl sebacate or sebacic acid and 2-aminoethanol or 4-amino-1-butanol were characterized by post-source decay matrix-assisted laser desorption/ionization time-of-flight (PSD-MALDI-TOF) and time-of-flight/time-of-flight tandem mass spectrometry (MALDI-TOF/TOF-MS/MS). Sodiated oligomers were selected as precursor ions for dissociation studies. PSD analysis was performed on dimethyl sebacate, dicarboxylic, carboxylic and amino alcohol, and diamino alcohol terminated oligomers. PSD-MALDI-TOF mass spectra yielded information on the fragmentation mechanisms of the poly(ester amide) chains, showing that the main cleavages proceed through a beta-hydrogen transfer rearrangement. MALDI-TOF/TOF-MS/MS provided structural information concerning ester/amide sequences in the polymer chains. As expected, together with the ions appearing in the PSD-MALDI mass spectrum, several new abundant fragment ions in the low-mass range are present in MALDI-TOF/TOF-MS/MS spectra. These new product ions proved to be diagnostic and made it possible to establish the presence of random sequences of ester and amide bonds in the poly(ester amide)s samples.  相似文献   

16.
A method for adapting widely used CE conditions for the separation of fluorescently labeled carbohydrates to permit online ESI‐MS detection is presented. Reverse polarity separations were performed in bare fused‐silica capillaries with an acidic BGE. Under these conditions, negatively charged 8‐aminopyrene 1,3,6‐trisulfonate‐labeled carbohydrates migrate forward against the EOF, which is towards the capillary inlet. Therefore, the CE‐MS interface must simultaneously back‐fill the capillary, in order to maintain the CE circuit, and provide a stable forward flow at the sprayer tip to support the electrospray process. This was achieved using a junction‐at‐the‐tip interface, which provides a flow of solution to the junction formed by the capillary terminus and the inner wall of the emitter needle tip. Because the flow rate required for this arrangement is much less than in conventional sheath flow interfaces, dilution of the analytes is minimized. Optimized separation conditions permit baseline resolution of glucose oligomers containing up to 15 glucose units, while longer oligomers, up to 33 glucose units, were observed as resolved peaks in the negative ion mode mass spectrum.  相似文献   

17.
Cyclic alpha-(1-->4)-glucans with degrees of polymerization (DPs) 9-31 were isolated from a mixture of cyclization products formed in the early stage of the action of cyclodextrin glucanotransferase (CGTase) on synthetic amylose, and characterized by matrix-assisted laser desorption ionization time-of-flight MS, 13C-NMR and HPLC of their partial acid hydrolyzates. High-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection for an accurate estimation of cyclic alpha-(1-->4)-glucans was developed using those isolate glucans as quantification standards, and by HPAEC, the time course of the cyclization reaction of CGTase from an alkalophilic Bacillus sp. A2-5a on synthetic amylose was determined.  相似文献   

18.
The selective modification of arginine residues by malondialdehyde (MDA) was used to improve the mass spectrometric analysis of arginine oligomers (Arg(x), x = 4, 6, 7, 8, 9) and an arginine-containing dendrimeric peptide. MDA tagging significantly increased the hydrophobicity of the arginine side-chain and resulted in improved retention in RP HPLC of the oligoarginines using formic acid as mobile phase additive. This avoided the use of TFA to generate sufficient retention, as TFA was shown to lead to a dramatically reduced sensitivity (up to ten-fold for Arg(8) and Arg(9)) as a result of the strong signal suppression by ion pairing with multiple basic residues. MDA modification of Arg oligomers not only resulted in improved detection sensitivity for most of the peptides studied (e. g., more than six-fold for Arg(7)), but also greatly enhanced the quality of MS/MS spectra, in line with previous results for other peptides. Furthermore, MDA modification helped to identify major side products in a sample of a dendrimeric peptide, a class of peptides that is typically difficult to analyze by MS.  相似文献   

19.
20.
This study reports for the first time the complete liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) and tandem mass spectrometry (MS/MS) analyses performed in negative ion mode of saturated unsulfated chondroitin oligosaccharides up to 16-mers and comparison with hyaluronic acid (HA) oligomers differing only in the nature of the hexosamine residue. MS/MS of the chondroitin disaccharide on the singly charged precursor at m/z 396.1 afforded a glycosidic cleavage C1 product ion at m/z 192.9. In the tetrasaccharide, C2 (m/z 396.0) and C3 (m/z 572.0) product anions were generated by glycosidic cleavage. A C5 [M-2H]2- product ion at m/z 475.1 was generated by the glycosidic cleavage of the hexasaccharide, and a C7 ion (m/z 664.6, charge state of -2) was produced from the octasaccharide. The same fragmentation pattern of deprotonated oligomers was observed for the largest oligosaccharides, from 10- to 16-mers. There has been no previous report of MS/MS spectra for unsulfated chondroitin oligomers of these sizes. Unsulfated saturated chondroitin oligosaccharides with x-mer units and larger than a tetrasaccharide dissociate to almost exclusively form CX-1-type ions. Saturated HA oligomers also afforded the same fragmentation pattern as deprotonated oligomers by ESI-MS and MS/MS analyses. Thus, under the experimental conditions used in the current study, we were unable to distinguish between unsulfated chondroitin and HA.  相似文献   