首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An experimental injection port has been designed for split or splitless sample introduction in capillary gas chromatography; the inlet uses electronic pressure control, in order that the column head pressure may be set from the GC keyboard, and the inlet may be used in the constant flow or constant pressure modes. Alternatively, the column head pressure may be programmed up or down during a GC run in a manner analogous to even temperature programming. Using electronic pressure control, a method was developed which used high column head pressures (high column flow rates) at the time of injection, followed by rapid reduction of the pressure to that required for optimum GC separation. In this way, high flow rates could be used at the time of splitless injection to reduce sample discrimination, while lower flow rates could be used for the separation. Using this method, up to 5 μl of a test sample could be injected in the splitless mode with no discrimination; in another experiment, 2.3 times as much sample was introduced into the column by using electronic pressure programming. Some GC peak broadening was observed in the first experiment.  相似文献   

2.
We have developed a new microfluidic chip capable of accurate metering, pneumatic sample injection, and subsequent electrophoretic separation. The pneumatic injection scheme, enabling us to introduce a solution without sampling bias unlike electrokinetic injection, is based upon the hydrophobicity and wettability of channel surfaces. An accurately metered solution of 10 nL could be injected by pneumatic pressure into a hydrophilic separation channel through Y-shaped hydrophobic valves, which consist of polydimethylsiloxane (PDMS) and fluorocarbon (FC) film layers. We demonstrated the successful pneumatic injection of a red ink solution into the separation channel as a proof of the concept. A mixture of fluorescein and dichlorofluorescein (DCF) could be baseline-separated using a single power source in microchip electrophoresis.  相似文献   

3.
Study of injection bias in a simple hydrodynamic injection in microchip CE   总被引:1,自引:0,他引:1  
The electrokinetically pinched method is the most commonly used mode for sample injection in microchip capillary electrophoresis (microCE) due to its simplicity and well-defined sample volume. However, the limited injection volume and the electrophoretic bias of the pinched injection may limit its universal usage to specific applications. Several hydrodynamic injection methods in microCE have been reported; however, almost all claimed that their methods are bias-free without considering the dispensing bias. To investigate the dispensing bias, a simple hydrodynamic injection was developed in single-T and double-T glass microchips. The sample flow was produced by hydrostatic pressure generated by the liquid level difference between the sample reservoir and the other reservoirs. The reproducibility of peak area and peak area ratio was improved to a significant extent using large-surface reservoirs for the buffer reservoir and the sample waste reservoir to reduce the Laplace pressure effect. Without a voltage applied on the sample solution, the voltage-related sample bias was eliminated. The dispensing bias was analyzed theoretically and studied experimentally. It was demonstrated that the dispensing bias existed and could be reduced significantly by appropriately setting up the voltage configuration and by controlling the appropriate liquid level difference.  相似文献   

4.
提出了纳升级进样量的微流控芯片流动注射气体扩散分离光度检测系统. 制作三层结构微流控芯片, 在玻璃片上加工微反应通道, 用聚二甲基硅氧烷[Poly(dimethylsiloxane), PDMS]加工气体渗透膜和具有接收气体微通道的底片, 实现了生成气体的化学反应、气-液分离和检测在同一微芯片上的集成化. 采用缝管阵列纳升流动注射进样系统连续进样, 用吸光度法测定NH+4以验证系统性能. 结果表明, 该系统对NH+4的检出限为140 μmol/L(3σ), 峰高精度为3.7%(n=9). 在进样时间12 s、注入载流48 s和每次进样消耗200 nL试样条件下, 系统分析通量可达60样/h. 若加大样品量到800 nL, 使接收溶液停流1 min, 该系统对NH+4的检出限可达到35 μmol/L(3σ), 但分析通量降低到20样/h.  相似文献   

5.
Sample injection in microchip-based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on-chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure-generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure-driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4–6 for the analyte peaks in a 3 cm long analysis channel.  相似文献   

6.
Micro free flow electrophoresis (µFFE) is a valuable technique capable of high throughput rapid microscale electrophoretic separation along with mild operating conditions. However, the stream flow separation nature of free flow electrophoresis affects its separation performance with additional stream broadening due to sample stream deflection. To reduce stream broadening and enhance separation performance of µFFE, we presented a simple microfluidic device that enables injection bandwidth control. A pinched injection was formed in the reported µFFE system using operating buffer at sample flow rate ratio (r) setting. Initial bandwidth at the entrance of separation chamber can be shrunk from 800 to 30 µm when r increased from 1 to 256. Stream broadening at the exit of separation chamber can be reduced by about 96% when r increased from 4 to 128, according to both theoretical and experimental results. Moreover, the separation resolution for a dye mixture was enhanced by a factor of 4 when r increased from 16 to 128, which corresponded to an 80% reduction in sample initial bandwidth. Furthermore, a similar enhancement on amino acids separation was obtained by using injection control in the reported µFFE device and readily integrated into online/offline sample preparation and/or downstream analysis procedures.  相似文献   

7.
Zhang L  Yin X  Fang Z 《Lab on a chip》2006,6(2):258-264
A simple method for injecting well-defined non-biased sample plugs into the separation channel of a microfluidic chip-based capillary electrophoresis system was developed by a combination of flows generated by negative pressure, electrokinetic and hydrostatic forces. This was achieved by using only a single syringe pump and a single voltage supply at constant voltage. In the loading step, a partial vacuum in the headspace of a sealed sample waste reservoir was produced using a syringe pump equipped with a 3-way valve. Almost instantaneously, sample was drawn from the sample reservoir across the injection intersection to the sample waste reservoir by negative pressure. Simultaneously, buffer flow from the remaining two buffer reservoirs pinched the sample flow to form a well-defined sample plug at the channel intersection. In the subsequent separation stage, the vacuum in headspace of the sample waste reservoir was released to terminate all flows generated by negative pressure, and the sample plug at the channel intersection was electrokinetically injected into the separation channel under the potential applied along the separation channel. The liquid levels of the four reservoirs were optimized to prevent sample leakage during the separation stage. The approach considerably simplified the operations and equipment for pinched injection in chip-based CE, and improved the throughput. Migration time precisions of 3.3 and 1.5% RSD for rhodamine123 (Rh123) and fluorescein sodium (Flu) in the separation of a mixture of Flu and Rh123 were obtained for 56 consecutive determinations with peak height precisions of 6.2% and 4.4% RSD for Rh123 and Flu, respectively.  相似文献   

8.
Li Y  DeVoe DL  Lee CS 《Electrophoresis》2003,24(1-2):193-199
Isoelectric focusing (IEF) separations, in general, involve the use of the entire channel filled with a solution mixture containing protein/peptide analytes and carrier ampholytes for the creation of a pH gradient. Thus, the preparative capabilities of IEF are inherently greater than most microfluidics-based electrokinetic separation techniques. To further increase sample loading and therefore the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from solution reservoirs, is demonstrated in this study. The proteins/peptides continuously migrate into the plastic microchannel and encounter a pH gradient established by carrier ampholytes originally present in the channel for focusing and separation. Dynamic sample introduction and analyte focusing in plastic microfluidic devices can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Under the influence of 30 min electrokinetic injection at constant electric field strength of 500 V/cm, the sample loading is enhanced by approximately 10-100 fold in comparison with conventional IEF.  相似文献   

9.
Qi LY  Yin XF  Zhang L  Wang M 《Lab on a chip》2008,8(7):1137-1144
A rapid and variable-volume sample loading scheme for chip-based sieving electrophoresis was developed by negative pressure combined with electrokinetic force. This was achieved by using a low-cost microvacuum pump and a single potential supply at a constant voltage. Both 12% linear polyacrylamide (LPA) with a high viscosity of 15000 cP and 2% hydroxyethylcellulose (HEC) with a low viscosity of 102 cP were chosen as the sieving materials to study the behavior and the versatility of the proposed method. To reduce the hydrodynamic resistance in the sampling channel, sieving material was only filled in the separation channel between the buffer waste reservoir (BW) to the edge of the crossed intersection. By applying a subambient pressure to the headspace of sample waste reservoir (SW), sample and buffer solution were drawn immediately from sample reservoir (S) and buffer reservoir (B) across the intersection to SW. At the same time, the charged sample in the sample flow was driven across the interface between the sample flow and the sieving matrix into the sieving material filled separation channel by the applied electric field. The injected sample plug length is in proportion with the loading time. Once the vacuum in SW reservoir was released to activate electrophoretic separation, flows from S and B to SW were immediately terminated by the back flow induced by the difference of the liquid levels in the reservoirs to prevent sample leakage during the separation stage. The sample consumption was about 1.7 x 10(2) nL at a loading time of 1 s for each cycle. Only 0.024 s was required to transport bias-free analyte to the injection point. It is easy to freely choose the sample plug volume in this method by simply changing the loading time and to inject high quality sample plug with non-distorted shape into the separation channel. The system has been proved to possess an exciting potential for improving throughput, repeatability, sensitivity and separation performance of chip-based sieving electrophoresis.  相似文献   

10.
设计了一种用于毛细管电泳系统的流动注射-负压进样装置。样品由蠕动泵输送到进样阀后再由缓冲液带到分离毛细管入口,由毛细管出口端施加的负压引入。进样时间由自制精密控时电路控制,经进样条件的优化,能获得良好的重现性。实验中两种阳离子峰面积和迁移时间的RSD(n=8)≤2.7%,优于传统重力进样,而且操作简便;与非接触电导检测器组装成流动注射-毛细管电泳系统,可实现快速、高效的在线分析。初步应用于无机阳离子的分离,取得了满意的结果。  相似文献   

11.
The characteristics of bias caused by split-flow electrokinetic injection (SEKI), a new type of sample injection method used in coupled flow injection-capillary electrophoresis system (FI-CE), was investigated using pseudoephedrine hydrochloride, a basic drug, and ibuprofen, an acidic drug, as model analytes. It was found that bias imposed by SEKI under the condition of continuous sample matrix/running buffer was similar to that done by electrokinetic injection (EKI). The linearity of calibration curve provided by SEKI was similar to that offered by non-bias hydrodynamic injection (HDI) but significantly better than that obtained by EKI. These features were exploited to improve analytical performances in simultaneous determination of the minor ingredient of pseudoephedrine hydrochloride and the major ingredient of ibuprofen in a pharmaceutical preparation. Detectability of 0.7 mg/l for pseudoephedrine hydrochloride was achieved at a sample throughput rate of 24 times per hour, which is 30% lower than that obtained by HDI-based conventional CE. Relative standard deviations (RSDs) of 2.8% for the minor ingredient and 1.2% for the major ingredient were produced in 11 runs of a test solution containing 13.1 mg/l pseudoephedrine hydrochloride and 81.4 mg/l ibuprofen. This is an improvement compared to that obtained by HDI-based conventional CE. Analytical results for two batches of compound ibuprofen tablets by the SEKI-based FI-CE approach were in good agreement with that obtained by a conventional high performance liquid chromatographic method. __________ Translated from Chinese Journal of Chromatography, 2005, 23(2) (in Chinese)  相似文献   

12.
罗金文  朱海霖  李会林 《色谱》2005,23(2):189-192
以碱性药物盐酸伪麻黄碱和酸性药物布洛芬为对象研究了分流式电动进样(一种用于流动注射-毛细管电泳(FI-CE)联用系统的新进样方法)歧视效应的特性。结果发现:在样品介质与运行缓冲液一致的条件下,FI-CE分流式电动进样产生的歧视效应与电动进样相似,但获得的校正曲线的线性明显优于电动进样,而与没有歧视效应的压力进样所获得的线性相似。利用这些特征提高了同时测定复方布洛芬片中少量组分盐酸伪麻黄碱和主要组分布洛芬的分析性能。在24次/h的采样频率下,盐酸伪麻黄碱的检测限为0.7 mg/L,比采用压力进样的毛细管电泳法所得的检测限低30%。连续进样11次分析含有13.1 mg/L盐酸伪麻黄碱和81.4 mg/L布洛芬的试样溶液,峰面积的相对标准偏差分别为2.8%(盐酸伪麻黄碱)和1.2%(布洛芬),明显优于采用压力进样的毛细管电泳法。用该法测定了两批复方布洛芬片中两种组分的含量,所得结果与高效液相色谱法的测定结果一致。  相似文献   

13.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

14.
Gai H  Yu L  Dai Z  Ma Y  Lin B 《Electrophoresis》2004,25(12):1888-1894
A simple method was developed for injecting a sample on a cross-form microfluidic chip by means of hydrostatic pressure combined with electrokinetic forces. The hydrostatic pressure was generated simply by adjusting the liquid level in different reservoirs without any additional driven equipment such as a pump. Two dispensing strategies using a floating injection and a gated injection, coupled with hydrostatic pressure loading, were tested. The fluorescence observation verified the feasibility of hydrostatic pressure loading in the separation of a mixture of fluorescein sodium salt and fluorescein isothiocyanate. This method was proved to be effective in leading cells to a separation channel for single cell analysis.  相似文献   

15.
Hybrid microfluidic/nanofluidic devices offer unique capabilities for manipulating and analyzing minute volumes of expensive or hard-to-obtain samples. Here, multilayer poly-(methyl methacrylate) microchips, with multiple spatially isolated microfluidic channels interconnected by nanocapillary array membranes (NCAMs), are fabricated using an adhesive contact printing process. The NCAMs, positioned between the microfluidic channel layers, add functionality to the inter-microchannel fluid transfer unit operation. They do so because the transport of specific analytes through the NCAM can be controlled by adjusting the ionic strength, the polarity of the applied bias, the surface charge density, and the pore size. A simplified, floating injection technique for NCAM-coupled nanofluidic devices is described and compared with conventional biased injection. In the floating injection approach, a voltage is applied across the injection channel and the slight electric field extension at the cross-section is used to transfer analytes through the nanopores to the separation channel. Floating injection excels in plug reproducibility, separation resolution, and operation simplicity, although it decreases assay throughput relative to biased injection. Floating injection can avoid the uneven distribution of analytes in the microfluidic channel that sometimes results from biased injection because of the volume mismatch between NCAM nanopore transport capacity and the supply of fluid. Moreover, the pressure-driven flow caused by the mismatch of the EOFs in the microfluidic channels connected by an NCAM must be considered when using NCAMs with pore diameters below 50 nm.  相似文献   

16.
A novel pressure-driven sample injection method was developed as an alternative to electrokinetic injection, and electrophoretic separation was carried out on a microfabricated device employing this method. This method enables a defined volume of liquid dispensing, followed by instantaneous injection driven by pneumatic pressure, greatly simplifying the injection procedure. A particular microstructure, called a "metering chamber", has been designed for the quantitative dispensing of an ultra-low volume of sample liquid; a "hydrophobic passive valve" equipped with an air vent channel is employed for injecting a dispensed sample into the separation channel. The reproducibility of dispensing was 3.3% (n = 15), expressed by the variation of dispensed volumes. The electrophoretic separation of DNA fragments was performed using this injection method, varying the injection volumes from 0.45 to 4.0 nL, and the separation efficiencies were compared. This precise injection method, easily variable in injection volumes, is highly suitable for quantitative as well as qualitative electrophoretic analyses.  相似文献   

17.
A microchip-based capillary electrophoresis (μCE) system was interfaced with a microwave induced plasma optical emission spectrometry (MIP-OES) to provide copper species separation capabilities. This system uses an extremely low flow demountable direct injection high efficiency nebulizer (D-DIHEN) sited directly at the liquid exit of the chip. A supplementary flow of buffer solution at the channel exit was used to improve nebulization efficiency. A small evaporation chamber has been incorporated into the interface in order to prevent the losses associated with traditional spray chambers, allowing the entire aerosol sample to enter the plasma. Syringe pumps were used to manipulate the flow rate and flow direction of the sample, buffer, and supplementary buffer solution. Sample volumes of 25 nL can be analyzed. With application of an electric field up to 500 V cm−1, species such as Cu(II) and Cu(EDTA)2− were separated in acidic solution within 90 s using a 26 mm long separation channel etched in a glass base. Resolution of the Cu(II) and Cu(EDTA)2− peaks was 1.1 using the chip-based μCE-MIP-OES system.   相似文献   

18.
A split/splitless capillary injection port has been developed for electronic pressure programming (EPP) in gas chromatography. The inlet may be operated in several modes: constant pressure, constant flow, vacuum compensation (for gas chromatography–mass spectrometry (GC-MS)), pressure-programmed, or a combination mode enabling a pressure program to be followed by constant flow. A pressure-programming technique has been tried which uses high pressure (high column flow rate) at the time of injection followed by reduction in inlet pressure to a value required for normal chromatography. Sample is swept rapidly from the inlet and into the column, reducing contact with the hot, active inlet surfaces which cause sample decomposition. The decomposition of endrin and 4,4′-DDT, two labile pesticides, can be substantially reduced using this technique and modest improvements were also observed with the carbamate pesticide carbaryl.  相似文献   

19.
In this work, a simple and novel sheath‐flow sample injection method (SFSIM) is introduced to reduce the band broadening of free‐flow zone electrophoresis separation in newly developed self‐balance free‐flow electrophoresis instrument. A needle injector was placed in the center of the separation inlet, into which the BGE and sample solution were pumped simultaneously. BGE formed sheath flow outside the sample stream, resulting in less band broadening related to hydrodynamics and electrodynamics. Hemoglobin and C‐phycocyanin were successfully separated by the proposed method in contrast to the poor separation of free‐flow electrophoresis with the traditional injection method without sheath flow. About 3.75 times resolution enhancement could be achieved by sheath‐flow sample injection method.  相似文献   

20.
The ability to accurately inject small volumes of sample into microfluidic channels is of great importance in electrophoretic separations. While electrokinetic injection of nanoliter scale volumes is commonly utilized in microchip capillary electrophoresis (MCE), mobility and matrix bias makes quantitation difficult. Herein, we describe a new injection method based on the simple patterning of the crossing of channels that does not require sophisticated instrumentation. The sample volume injected into the separation channel is dependent on the ratio of the widths of the crossing channels. This injection method is capable of introducing, into a separation channel, multiple plugs of sample on a large scale. This injection technique is tested for zone electrophoresis in native and surface modified poly(dimethylsiloxane) (PDMS) chips.  相似文献   