首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-performance liquid chromatography method is described for the determination of digoxin and its metabolites digoxigenin, digoxigenin monodigitoxoside, digoxigenin bis-digitoxoside and dihydrodigoxin (20S and 20R) excreted in urine and feces. The urine sample or fecal supernatant is extracted with methylene chloride in the presence of digitoxigenin or digitoxin as internal standard. Pre-column derivatization is achieved using 1-naphthoyl chloride with subsequent separation of the derivatized compounds on either a normal- or reversed-phase system with fluorescence detection. Recoveries for digoxin and all metabolites from fecal samples were in the range 60-74%, which is comparable to that previously determined for urine samples. Standard curve data revealed linearity over a wide range of concentrations. Coefficients of variation for the analysis were less than 10% for all compounds over a range of 5-125 ng per ml urine and 10-250 ng per 200 mg feces. Peaks for digoxin and metabolites in urine and feces were obtained when human excreta were analyzed.  相似文献   

2.
The use of anabolic steroids in racehorses is strictly regulated. We have developed a method for the simultaneous analysis of 11 anabolic steroids: fluoxymesterone, 17alpha-methyltestosterone, mestanolone, methandienone, methandriol, oxymetholone, boldenone, furazabol, methenolone, nandrolone, and stanozolol, for possible application to a doping test in racehorses. We selected 15 kinds of target substances for a doping test from the main metabolites of these anabolic steroids, and established a method for simultaneous analysis. Urine was hydrolyzed and subjected to solid-phase extraction. Then, the residue from the extracts was derivatized by trimethylsilylation. The derivatized samples were subjected to ion-trap gas chromatography-tandem mass spectrometry, and their mass chromatograms and product ion spectra were obtained. The limit of detection of the target substances was 5 - 50 ng/mL, and the mean recovery and coefficient of variation were 71.3 - 104.8% and 1.1 - 9.5%, respectively.  相似文献   

3.
Higashi T  Takido N  Shimada K 《The Analyst》2003,128(2):130-133
The detection and characterization of 20-oxosteroids in rat brains by liquid chromatography (LC)-electron capture atmospheric pressure chemical ionization (ECAPCI)-mass spectrometry (MS) is described. In the present method, oxosteroids were derivatized with a highly electron-affinitive reagent, 2-nitro-4-trifluoromethylphenylhydrazine, to convert them to the corresponding hydrazones. The derivatized steroids showed over 20-fold higher sensitivity in ECAPCI-MS than intact steroids measured in positive-APCI-MS. A brain sample was homogenized, purified with two disposable cartridges, derivatized and subjected to LC-ECAPCI-MS. Pregnenolone, progesterone, 5alpha-dihydroprogesterone, allopregnanolone and epiallopregnanolone were clearly detected with a 50 mg sample of the brain tissue.  相似文献   

4.
The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50–300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10–150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.  相似文献   

5.
头发中内源性类固醇激素的气相色谱-串联质谱分析   总被引:3,自引:1,他引:2  
沈敏  向平  沈保华  王萌烨 《色谱》2008,26(4):454-459
建立了建康人头发中内源性类固醇兴奋剂睾酮、表睾酮、雄酮、苯胆烷醇酮和脱氢表雄酮的气相色谱-串联质谱(GC-MS/MS)分析方法。头发经碱水解后,以乙醚提取,经衍生化后采用GC-MS/MS的多反应监测模式(MRM)分析。方法的线性关系良好,检出限达0.1~0.2 pg/mg;提取回收率为74.6%~104.5%;日内测定的准确度为90.1%~113.7%,日内及日间测定的精密度均小于17.5%。应用所建立的方法测定了80例中国健康人头发中睾酮、表睾酮、雄酮、苯胆烷醇酮和脱氢表雄酮的生理水平,为内源性类固醇兴奋剂滥用的判断提供了方法和基础数据。  相似文献   

6.
Microcolumn liquid chromatography with slurry-packed capillary columns has been used to resolve mixtures of biologically important steroids and prostaglandins. In order to enhance detection sensitivity, the samples are first derivatized with a suitable chromophore-yielding agent. Hydroxy steroids were derivatized with either benzoyl chloride or 7-(chlorocarbonylmethoxy)-4-methylcoumarin, while Dns hydrazine was employed to react with the ketonic groups of certain steroidal conjugates. Bile acids can also be derivatized with bromomethylcoumarin to yield fluorescent products. The use of microcolumns permits both a high degree of component resolution and enhanced detection sensitivity.  相似文献   

7.
《Analytical letters》2012,45(7):1313-1322
ABSTRACT

A method to detect three anabolic steroids (boldenone, nandrolone and mesterolone) is presented. The anabolic steroids are isolated from equine plasma and urine by extraction with diethyl ether and C18 Sep-Pak cartridge adsorption, respectively. The extracts obtained were derivatized with trifluoroacetyl anhydride and analyzed by GC/SIM/MS. The selected ion monitoring (SIM) mode was applied to increase the sensitivity and, when possible, the higher m/z ions were selected to improve identification. Stability of derivatives was good and compounds having hydroxy and conjugated ketone groups produced trifluoroacetyl ester derivatives that were also stable. Repeatability of the chromatographic analysis was evaluated on the basis of area repeatability, and the coefficient of variation obtained was lower than 4.4. The detection limit was 1 and 5 ng/ml for all the anabolic steroids studied in equine plasma and urine, respectively.  相似文献   

8.
The nature of the carbohydrate-peptide bond and the composition of the carbohydrate chain in a β-1,3-glucanase from the marine molluskS. sachalinensis has been investigated. According to the results of the phenol-sulfuric acid method, the neutral sugars amounted to 6.5% of the molecular weight of the enzyme. The composition of the neutral sugars (Glc : Gal : Man 5:2:1) was determined by the GLC method. It was shown that the β-1,3-glucanase molecule contains no uronic or sialic acids. The amount of amino sugars (15% with equal amounts of glucosamine and galactosamine) was established by amino acid analysis. Alkaline degradation led via the β-elimination reaction to the splitting out of 50% of the neutral sugars and showed the existence of an O-glycosidic bond in the enzyme molecule. Various actions on the carbohydrate moiety (periodate oxidation and treatment with glycosidases) caused no appreciable change in the hydrolyzing capacity of the enzyme.  相似文献   

9.
A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA), and were determined using GC/NCI-MS and GC/NCI-MS/MS. The linear correlation coefficients for calibration in NCI-MS/MS were in the range 0.9880-0.9988. This method of derivatization with HFBA for use with GC/NCI was useful in determinations of 19-norandrosterone, boldenone, 19-noretiocholanolone, 2-methylandrosterone, nandrolone, 1-methyleneandrosterone, 1-methylandrosterone, 4-dihydroboldenone and mesterolone. The detection limits of this procedure were 5-20 ppb at a signal-to-noise (S/N) ratio of 3.  相似文献   

10.
Steroid determination by immunoassays results in significant interferences and inaccurate results. This study describes the development and validation of a new gas chromatographic-mass spectrometric method for the simultaneous quantification of 17alpha-hydroxyprogesterone (17alphaOHP), testosterone (T), dehydroepiandrosterone (DHEA), androstenedione (Delta4-A), cortisol (F) and pregnenolone (Preg) in serum of neonates. Steroids were extracted and purified from 0.5 mL serum using diethyl ether and Extrelut mini NT1 column. The extracts were derivatized with N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA)/trimethylsilyl iodide (TMSI)/dithioerythritol (DTE) and the resulting trimethylsilyl derivatives were quantified by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). The detection limit for all steroids was lower than 0.1 ng/mL. The limit of quantification was 0.1 ng/mL for all steroids except cortisol which was at 0.25 ng/mL. d3-Testosterone and methyltestosterone served as internal standards. Precision for all compounds at the concentrations of 0.5, 1, 5 and 10 ng/mL (n = 10) in fortified steroid-free serum samples ranged from 0.8% to 16.6%. Accuracy was calculated at the concentrations of 0.5, 1, 5 and 10 ng/mL and ranged from -9.2% to 10.6% (n = 10). Linear calibration equations were obtained for all five steroids (0.125-31.25 ng/mL) and for cortisol (0.125-200 ng/mL). Relative recoveries at concentrations 1.0 and 12.5 ng/mL ranged from 70.5% to 97.5%. Absolute recoveries at the same concentrations ranged from 73.2% to 96.6%. Reference intervals were estimated for infants aged from 9 to 40 days. The proposed steroid profile is suitable for routine analysis and provides meaningful data for samples within normal range as well as those with elevated levels.  相似文献   

11.
A functional group analysis method was developed to determine the quantitative content of carbonyl functional groups in atmospheric particulate organic matter (POM) using constant neutral loss scanning-tandem mass spectrometry (CNLS-MS/MS). The neutral loss method consists in monitoring the loss of a neutral fragment produced by the fragmentation of a precursor ion in a collision cell. The only ions detected are the daughter ions resulting from the loss of the neutral fragment under study. Then, scanning the loss of a neutral fragment characteristic of a functional group enables the selective detection of the compounds bearing the chemical function under study within a complex mixture. The selective detection of carbonyl functional groups was achieved after derivatization with pentafluorophenylhydrazine (PFPH) by monitoring the neutral loss of C(6)F(5)N (181 amu), which was characteristic of a large panel of derivatized carbonyl compounds. The method was tested on 25 reference mixtures of different composition, all containing 24 carbonyl compounds at randomly determined concentrations. The repeatability and calibration tests were satisfying as they resulted in a relative standard deviation below 5% and a linear range between 0.01 and 0.65 mM with a calculated detection limit of 0.0035 mM. Also, the relative deviation induced by changing the composition of the mixture while keeping the total concentration of carbonyl functional groups constant was less than 20%. These reliability experiments demonstrate the high robustness of the developed procedure for accurate carbonyl functional group measurement, which was applied to atmospheric POM samples.  相似文献   

12.
A gas-liquid chromatographic (GLC) method and an isotopic dilution-mass fragmentographic (ID-MF) procedure using the same capillary chromatographic separation are described for serum cholesterol assay. GLC included silylation and separation on a highly efficient glass capillary column which allowed the separation of cholesterol from cholestanol and the use of epicoprostanol as internal standard. The concentrations were calculated from the areas of the signals and digitalized by a reporting integrator. The reproducibility was 0.5% and the correlation with the ID-MF technique was 0.997. The ID-MF technique was characterized by the use of [3,4-13C] cholesterol as the labelled standard and a chemical ionization mode. The reproducibility was 0.8%.  相似文献   

13.
Lan Zhang  Jinfeng Chen  Yu He  Guonan Chen 《Talanta》2009,77(3):1002-2154
A simple, rapid and low-costing new mixed surfactant MEKC method has been developed for the analysis of five neutral anabolic steroids in this paper. It was found that the bile salt coupling with Triton X-100 was a suitable bi-micellar surfactant for the separation of these anabolic steroids with similar structure. The separation conditions were optimized in detail. The five natural and synthetic anabolic steroids, such as androstenedione (AD), 19-norandrostenedione (NAD), 1,4-androstadiene-3,17-dione (ADD), methandrostenolone (MA) and methyltestosterone (MT) were separated and detected in an alkaline buffer system (pH 9.0) containing 15 mM Britton-Robinson (BR) buffer, 50 mM sodium cholate (SC) and 0.1% (v/v) Triton X-100 with detection wavelength at 241 nm and 18 kV of separation voltage. Under the optimal conditions, five coexistence neutral steroids were completely separated within 12 min with the detection limits ranged from 0.20 to 0.51 μg/mL. This method was successfully used for detection and confirmation of the anabolic steroid methandrostenolone in methandrostenolone tablets and in the real human urine, GC-MS method was applied to confirm the free methandrostenolone existence in the urine sample in order to validate the reliability of MEKC method.  相似文献   

14.
This paper describes the preparation and optimization of packed capillary columns for reversed‐phase separation of steroids with CEC. The fabrication of on‐column frits is considered to be the most important step for obtaining a reproducible packed column for CEC separation. Porous silicate frits were generated in a fused‐silica capillary by heating the silica gel/sodium hydroxide solutions electrically. The optimized conditions involve silica gel (10.8%), sodium hydroxide (5.8%), and heating time (5 sec) with heating voltage (5V) for obtaining a 100‐μ end‐frit that can withstand pressure over 6000 psi. A HPLC pump was utilized to pack the 5‐μm ODS particle slurry into the capillary column. The ODS packed capillaries were then utilized for the separation of four anabolic cholesterols with a capillary electrophoresis system without pressurization of the column. The reproducibility of the packed columns was evaluated by measuring the relative standard deviations of four steroids. The relative standard deviations of migration time for column‐to‐column, day‐to‐day, and run‐to‐run are less than 7%, 2%, and 1% for four steroids, respectively.  相似文献   

15.
A rapid method of determining zinc and iron in food by flame atomic-absorption spectrophotometry with slurry nebulization into an air-acetylene flame has been developed. A V-groove, clog-free Babington-type nebulizer, coupled to a single-line flow-injection analysis (FIA) system, was employed to introduce the slurry into the spray chamber. Under the FIA conditions described, an injection frequency of 120/hr is possible, with negligible carry-over and memory effects. The calibration graphs were obtained by using various concentrations (up to 0.1 g/ml) of white bean homogenate as standards, rather than solutions. The method has been applied to various kinds of foods, including grains, vegetables, fruits and sausage. Homogenization of semi-prepared samples to form slurries took only 4 min. Relative deviations between results by the slurry and solution methods for both elements averaged 2-3%. Detection limits by the slurry method were 0.3 mug/ml Zn and 0.6 mug/ml Fe.  相似文献   

16.
This paper describes an improved method for the extraction and determination of three steroids, oestrone, 17beta-oestradiol, and the synthetic contraceptive steroid 17alpha-ethinyloestradiol in aqueous matrices. Samples of wastewater and environmental water were spiked with internal standards, comprising isotopically labelled analogues of the steroids to be determined. The samples were extracted using solid-phase extraction disks and the extracts were then derivatized to form tert.-butyldimethylsilyl derivatives. The derivatised steroids were determined in the final extracts by GC-MS or GC-MS-MS allowing an operational detection limit for each steroid in effluent samples of 1 ng l(-1).  相似文献   

17.
An improved method has been developed for the determination of the major neutral steroids (cholesterol and 5 beta-cholestan-3 beta-ol) and unconjugated bile acids (deoxycholic acid and lithocholic acid) in human faeces, using capillary gas chromatography with flame ionization detection. The freeze-dried faecal sample was subjected to a two-stage Soxhlet extraction followed by an aqueous alkali-organic solvent partition step to separate neutral steroids from bile acids. The neutral steroids were analysed as their trimethylsilyl ether derivatives on an OV-1 capillary column. The bile acids were further purified on a Sep-Pak C18 cartridge and then fractionated on a Sep-Pak SIL cartridge. Unconjugated bile acids were analysed as their methyl ester-trimethylsilyl ether derivatives also on an OV-1 capillary column. Quantitation of neutral steroids and unconjugated bile acids was achieved by reference to appropriate internal standards, added to the faecal extract immediately after the Soxhlet extraction stage. The method is being used in a study of the effect of diet on the metabolic activity of human gut flora.  相似文献   

18.
A generic LC-MS/MS method was developed for the analysis of potentially genotoxic alkyl halides. A broad selection of alkyl halides were derivatized using 4-dimethylaminopyridine in acetonitrile. The reaction conditions for derivatization, i.e., solvent, reaction time, temperature and concentration of alkyl halide, active pharmaceutical ingredient (API), and reagent, were optimized for sensitivity and robustness. The interference of the matrix and the API and the presence of water on the derivatization reaction were investigated for a model drug product (paracetamol/caffeine tablets). Hydrophilic interaction liquid chromatography was used to allow a quantitative determination of the derivatives by tandem mass spectrometry. The derivatization reaction was shown to be selective for alkyl halides, although some reactivity was also observed for an aromatic sulfonate, which is also genotoxic. Even though differences in reaction efficiencies have been observed, the enhanced sensitivity obtained by the derivatization allows the majority of the alkyl halides to be detected by MS/MS at relevant levels for genotoxic impurity evaluation, i.e., 10 mg kg(-1). Another key advantage is that for the majority of derivatives, reagent-related fragments are produced, which allows low-level screening for alkyl halides. Highly specific MS detection can be performed using neutral loss and precursor ion scan experiments. The applicability of a generic screening method will make the genotox evaluation less dependent on the quality of assessments based on predictions only, and it will provide essential information during the development of new chemical entities. In addition to screening, target analysis in the low milligrams per kilogram range can be performed. A similar response of the derivatized compounds was obtained in the range of 1-100 mg kg(-1) with a reproducibility better than 10%, which is sufficient for the determination of alkyl halides in APIs and drug products.  相似文献   

19.
气相色谱/质谱联用测定大鼠脑部的神经甾体   总被引:4,自引:0,他引:4  
闫彩珍  侯艳宁 《色谱》2004,22(1):12-15
应用气相色谱 质谱联用技术建立了大鼠脑部神经甾体的测定方法。游离型甾体和甾体硫酸酯分两步萃取。第一步用乙酸乙酯提取游离型甾体,第二步用氯仿/2 丁醇提取甾体硫酸酯,然后经固相萃取纯化。甾体硫酸酯进行溶剂解形成游离型甾体。游离型甾体和甾体硫酸酯分别经七氟丁酸酐衍生化后进行气相色谱 质谱分析。经初步研究雄性大鼠脑部游离型神经甾体孕烯醇酮(PREG)、黄体酮(PROG)、别孕烯醇酮(AP)和脱氢表雄酮(DHEA)的含量分别为(8.53±1.11) ng/g ,( 7.01±2.60) ng/g ,( 1.  相似文献   

20.
A gas-liquid chromatographic (GLC) method for monitoring T-2 and HT-2 toxins in plasma was developed. The procedure involved extraction of the toxins with ethyl acetate, chromatography on a C18 reversed-phase column and derivatization with heptafluorobutyric anhydride (HFBA). The T-2 and HT-2 HFBA derivatives were chromatographed on OV-17 at various temperatures and measured with an electron-capture detector. Iso-T-2 toxin and iso-HT-2 toxin were used as internal standards. Recoveries averaged 95.1 +/- 8.6% for T-2 toxin and 102.1 +/- 5.2% for HT-2 toxin at levels ranging from 40 to 120 ng/ml. The limits of detection were 30 and 5 ng/ml of T-2 and HT-2 toxin, respectively. The range of the assay covers plasma concentrations at which toxicity becomes manifest. The pharmacokinetic application of this GLC method is illustrated by simultaneous monitoring of T-2 and HT-2 toxins levels in plasma obtained after intravenous administration of T-2 toxin to a dog.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号