首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
A capillary zone electrophoresis (CZE) method was established to determine low concentration nitrate which was online preconcentrated with chloride-induced leading-type sample self-stacking for seawater samples. The sample self-stacking was based on transient isotachophoresis in which chloride served as leading ion, and dihydrogenphosphate in the background electrolyte (0.1 M phosphate) as the terminating one. Due to the small mobility difference between nitrate and chloride, the isotachophoresis time was so long that nitrate could not separate from the rear sharp boundary between chloride and the background electrolyte (BGE) when it migrated to the detection window. A zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)propane sulfonate was added to the BGE to enlarge the mobility difference for its selective interaction with anions. Thus, a highly conductive sample could be injected in a large volume with about fourfold sensitivity enhancement compared to that of field amplification sample stacking in which nitrate was dissolved in pure water. The relative standard deviations (n=5) of migration time, peak area, peak height were 0.1, 3.0, 1.5%, respectively. The limit of detection (S/N=3) for nitrate was 35 microg/l in seawater samples with relatively low concentration BGE (0.1 M sodium phosphate, pH 6.2). The overall procedure consisting of online preconcentration and separation was as simple as routine CZE except for a slightly longer sample injection time (3-4 min).  相似文献   

2.
Online sample concentration of acidic drugs by transient isotachophoresis (t-ITP) with the injection of a base is described in capillary zone electrophoresis (CZE). A positively coated capillary was conditioned with background electrolyte (ammonium acetate at pH 6). A long plug of sample solution (S) prepared in ammonium acetate was then hydrodynamically injected followed by the base (tetrapropylammonium hydroxide). A negative voltage was applied and caused the hydroxide ions from the base to penetrate the S zone and created a pH junction that swept through the S zone. The analytes stack at the junction where the mechanism of focusing was transient ITP with the acetate and hydroxide ions as leading and terminating ions, respectively. The concentrated analytes separated in co-EOF CZE once the hydroxide was exhausted. The base stacking strategy was tested using hypolipidemic, nonsteroidal anti-inflammatory, and diuretic drugs, and afforded 19-37 improvements in peak height.  相似文献   

3.
The applicability of capillary zone electrophoresis (CZE) to ions having relatively low natural occurrences in sea water is limited by method's relatively poor concentration detection sensitivity. A combination of CZE with indirect UV detection and transient isotachophoresis (tITP) pre-concentration was developed to evolve the CZE practical utility towards the quantitative determination of the minor sea water cationic components, strontium and lithium. The ITP stacking criterion at the initial stage of a CZE separation was met by taking a highly mobile sodium, the principle matrix cation, to perform the role of a leading ion, whereas the moderately mobile sample macrocomponents, Ca2+ and Mg2+, acted as the terminating ion. The carrier electrolyte, consisting of 10 mM 4-methylbenzylamine and 1.5 mM citric acid at pH 4.8, was found to be optimal to accommodate both analyte cations in the ITP range and then separate them in the CZE mode, with relative standard deviations for migration times from 0.06-0.15% and for peak areas from 4-8%. The limits of detection were 1.3 mg l(-1) Sr2+ and 0.12 mg l(-1) Li+. The developed method was applied to the analysis of a surface sea water sample and a sea water reference material. The results were in good agreement with those obtained by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and electrothermal atomic absorption spectrometry (ET-AAS).  相似文献   

4.
Shihabi ZK 《Electrophoresis》2002,23(11):1628-1632
Nonaqueous capillary electrophoresis (NACE) is a useful mode in CE for separation and quantification of hydrophobic compounds. However, because of the low conductivity of most of the organic solutions, stacking is not used often in this technique and the sample volume is very limited. As a result of the small sample volume, the detection limits are poor. Furthermore, NACE is affected greatly by the presence of salts in the sample. Here, we show that transient isotachophoresis (t-ITP) can be used easily in this type of electrophoresis to enhance the detection limits and also to reverse the deleterious effects of salts in the sample. Several factors, which affect the stacking in this type of electrophoresis, are described. For example, the presence of salts in the organic solvent, type of sample introduction, and the solvent for the terminating ion were all found to have profound effects on the degree of concentration. Furthermore, the separation time can be shortened by t-ITP.  相似文献   

5.
Beckers JL 《Electrophoresis》2000,21(14):2788-2796
A sample stacking procedure to which a specific combination of electrolyte solutions is applied is isotachophoresis (ITP) superimposed on capillary zone electrophoresis (CZE), a so-called ITP/CZE system. In ITP/CZE some components migrate in an ITP fashion on top of a background electrolyte, and the other analytes migrate in a zone electrophoretic manner. For such a system, the leading electrolyte consists of a mixture of an ionic species, L1, of high mobility (the leading ion of the ITP system), an ionic species, L2, of low mobility (the coions of the CZE system), and a buffering counter-ionic species, whereas the terminating solution only contains the ionic species L2 and the buffering counterions. The zones of the components migrating in the ITP/CZE mode are sharp owing to the self-correcting properties of the zones and the concentrations of the L1 ions of the system. Mobility windows can be calculated, indicating which ions can migrate in the ITP/CZE mode. In this article mobility windows are calculated by applying both strong and weak acids as L1 and L2 ions and it appears that mobility windows can be optimized by chosing different ratios of L1 and L2 as well as different pH values. It is possible to construct very narrow mobility windows, and thereby choose which component of a sample solution can be concentrated, and to what concentration, in a very selective way. The big advantage of ITP/CZE compared with applications such as transient ITP and transient stacking is that the stacked sample ionic species migrate in the ITP mode during the whole experiment; furthermore, they do not destack. Experimentally obtained electropherograms validate the calculated mobility windows for the ITP/CZE mode.  相似文献   

6.
T Hirokawa  H Okamoto  N Ikuta 《Electrophoresis》2001,22(16):3483-3489
Operational modes for transient isotachophoretic preconcentration capillary zone electrophoresis (tr-ITP-CZE) were studied by using 5 microM and 0.5 microM rare earth mixtures as analytes in comparison with field-enhanced sample stacking. After examination of several operational modes for tr-ITP, it was found that tr-ITP effectively occured even if both the leading electrolyte and the terminating electrolyte were injected after the sample plug. This was explained as the result of a field-enhanced stacking for both sample components and the leading and terminating ions. The observed theoretical plate numbers were 4-20 times higher than those obtained by normal stacking; and the estimated low limit of detectable concentration of rare-earth elements (REE) was ca. 0.1 microM which was 2.5 times lower compared to normal stacking. For the 0.5 microM sample, a concentration factor of 20 000 could be achieved after only tr-ITP.  相似文献   

7.
Electrokinetic supercharging (EKS) combines field-amplified sample injection with transient isotachophoresis (tITP) to create a powerful on-line preconcentration technique for capillary electrophoresis. In this work, EKS is enhanced with a positive pressure (pressure-assisted EKS, or PA-EKS) during injection to improve stacking of non-steroidal anti-inflammatory drugs (NSAIDs). Several parameters, including buffer composition and concentration, terminating electrolyte, organic modifier, and injection voltage and injection time of both terminating electrolyte and sample were optimized. Detection limits for seven NSAIDs were determined and an enhancement in sensitivity of almost 50,000-fold was obtained. The PA-EKS method has the potential to be a simple MS compatible preconcentration method to improve the sensitivity of CE.  相似文献   

8.
Shim SH  Riaz A  Choi K  Chung DS 《Electrophoresis》2003,24(10):1603-1611
A dual stacking mechanism based on transient isotachophoresis (TITP) and induced pH junction focusing is demonstrated as a means to increase the concentration sensitivity in capillary electrophoresis of highly saline samples. When stacking was carried out with an unbuffered saline sample of fluorescein between two zones of low mobility background electrolyte at high pH under an electric field of reverse polarity, two transient peaks at both boundaries of the sample zone were observed. One peak at the rear boundary could be inferred as a transient isotachophoretic stacked zone. Through computer simulations of an unbuffered sample with a high concentration of sodium chloride, we showed that the fast moving zones of sodium and chloride ions induced pH changes at both boundaries to satisfy the electroneutrality condition and that the peak at the front boundary was due to the induced pH junction. To verify the pH changes, an indicator, thymol blue, was added to an NaCl solution and the color changes under an electric field were observed. The proposed mechanism was supported by observing the dual stacking procedure for an unbuffered sample of 4-nitrophenol and measuring additional sensitivity enhancements by dual stacking for ten weakly acidic compounds. For the ten analytes including nucleoside phosphates, every dual stacking of an unbuffered sample exhibited an additional enhancement up to 86% larger than that of usual transient isotachophoresis of the corresponding buffered sample without loss of separation efficiency and reproducibility. Therefore, it would be useful to skip over buffering in sample preparation for TITP, contrary to the general recommendation.  相似文献   

9.
We describe a combination of selected ions as a terminating ion which is useful for transient isotachophoresis (ITP) in capillary zone electrophoresis (CZE) for the determination of nitrite and nitrate in seawater. In addition to 150 mM sulfate as the principal terminating ion, 10 mM bromate was added to a sample solution as the additional terminating ion. Artificial seawater containing 3 mM cetyltrimethylammonium chloride (CTAC) was adopted as a background electrolyte (BGE). The limits of detection (LODs) for nitrite and nitrate were 2.2 and 1.0 microg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.9 and 1.4%. The RSDs of peak height were 1.7 and 1.9%, the RSDs of migration time 0.11%. The proposed method was applied to the determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada (NRC). The results almost agreed with the assigned tolerance interval.  相似文献   

10.
Huang SW  Tzeng HF 《Electrophoresis》2012,33(3):536-542
A simple and rapid capillary electrophoretic method was developed for simultaneous determination of sub‐micromolar 2′‐deoxycytidine 5′‐diphosphate (dCDP) and 2′‐deoxycytidine 5′‐triphosphate (dCTP) levels in enzyme assays without using radioactively labeled substrates. The separation was performed at 25°C using MES in the BGE as the terminating ion, the chloride ions in the sample buffer as the leading ion, and PEG 4000 in the BGE as the EOF suppressor for sample stacking by transient isotachophoresis (tITP). Several parameters affecting the separation were investigated, including the pH of the BGE, the concentration of sodium chloride in the sample buffer, and the concentrations of MES and PEG 4000 in the running buffer. Good separation with high separation efficiency was achieved within 6 min under optimal conditions. In comparison with the simple CZE method, the present tITP‐CZE method enabled a 150‐fold increase in the injection time without any decrease in resolution and the sensitivity was enhanced up to two orders of magnitude with the new method. The linear range of the method was 0.1–10 μM for dCDP and dCTP. The limits of detection of dCDP and dCTP were 85 and 73 nM, respectively. The proposed method was successfully applied for the activity assay of ribonucleotide reductase from Hep G2 and Sf9 cells.  相似文献   

11.
Transient capillary isotachophoresis (CITP)-capillary zone electrophoresis (CZE) in presence of electroosmotic flow (EOF) was utilized for the measurement of adenosine deaminase activity in human erythrocytes. Phosphates, dominant anions of the sample matrix, were used as leading ions for transient isotachophoresis, and borates (0.3 M, pH 10) were used as terminating ions and background electrolyte for CZE. Final experimental conditions made it possible to inject 70% of the total capillary volume (1.45 microL) with the sample. Enzymatic conversion products (inosine and hypoxanthine), present in the sample in the low-micromolar range, were determined using optimized conditions. The limit of detection was 28 nM using UV detection at 202 nm. The presented data shows that CITP-CZE can be performed in uncoated capillaries in the presence of strong EOF.  相似文献   

12.
This review discusses recent progress in the application of one of the most effective in-line preconcentration techniques used in electrophoresis in capillaries and microchips, electrokinetic supercharging (EKS). Conventionally considered as a transient isotachophoresis (tITP) step put into effect after the electrokinetic sample injection (EKI), EKS presumes that the electrolyte filled into the capillary (or microchip channel) comprises a co-ion acting as a leading ion to stack the injected analytes. Subsequently, to create the tITP state, one needs an additional injection of a suitable terminating ion. As a resulting increase in sensitivity strongly depends on the performance of both EKS stages, two theoretical sections are focused on hints for proper arrangement of EKI and tITP elaborated by means of computer simulation. In particular, factors affecting the injected amount of analytes, different modes of introducing the sample, suitable combinations of leading and terminating ions, and optimization of supporting electrolyte compositions are discussed with an objective to increase the enrichment factors. A comprehensive coverage of recent EKS applications in capillary and microchip electrophoresis, including metal ions, pharmaceuticals, peptides, DNA fragments, and proteins, demonstrates attainable sensitivity enhancements up to two orders of magnitude. This should make this method exportable to other analytes and facilitate its more widespread use to applications that require low limits of detection.  相似文献   

13.
We describe capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) for the determination of low concentrations of nitrite and nitrate ions in seawater. Bromide-free artificial seawater was adopted as background electrolyte (BGE) to eliminate the interference of high concentrations of salts in seawater. To reverse the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the BGE. High concentrations of chlorate were added to sample solutions as the terminating ion to generate the ITP process before the CZE separation. In general, the stacking effect increased with increasing amounts of chlorate injected into the capillary. The limits of detection (LODs) for nitrite and nitrate were 0.063 and 0.033 mg/L when the chlorate concentration was 600 and 200 mM, respectively; these were half of those obtained by CZE without the transient ITP. The LODs were obtained at a signal to noise ratio (S/N) of 3. The relative standard deviations (RSD, n = 10) of the peak areas for these ions were 3.2 and 2.9%. The RSDs of peak heights for these ions were 1.6 and 2.1%. The RSDs of migration times for these ions were 0.67 and 0.46%.  相似文献   

14.
利用芯片电泳方法考察瞬间等速电泳-筛分电泳偶联分析的结果,比较了自由溶液和筛分介质中DNA瞬间等速电泳的预浓缩效果.结果显示,相比较于筛分介质条件,自由溶液瞬间等速电泳有利于改善预浓缩和后续筛分电泳分离效果.对此结果的解释是:自由溶液条件下DNA迁移速度的提高可以延长瞬间等速电泳持续时间,有利于提高预浓缩效率.此外,样品压缩区带在自由溶液-筛分介质界面的二次富集也是预浓缩效果得到改善的原因之一.  相似文献   

15.
Many water-miscible organic solvents, especially acetonitrile and acetone, bring along significant degrees (approximately 30 times) of stacking by electroinjection through high-field amplified injection for the basic compounds compared to that for aqueous buffers or water. The relative stacking of different compounds in acetonitrile or acetone is different compared to that for water. Stacking by electroinjection in organic solvents is less stringent and easier to accomplish in practice. Acids and salts, in aqueous solutions, can ruin the stacking for both organic and aqueous solvents; however, this effect can be better tolerated by diluting the sample in acetonitrile. Thus, this stacking is termed "organic solvent high-field amplified injection". This stacking by electroinjection is enhanced by increasing the electrophoresis buffer concentration and can be better than that by pressure injection. From the practical aspects, some cationic drugs present in serum such as amiodarone can be detected at the therapeutic levels by electroinjection on the capillary after protein precipitation by acetonitrile.  相似文献   

16.
李云  何友昭 《色谱》2005,23(1):100-102
采用添加乙腈引发的场放大进样与瞬间等速电泳结合的预富集方法,实现了在毛细管内大体积高盐样品中阳离子的有效富集与分离。详细讨论了影响富集的缓冲体系、尾随离子种类、毛细管有效长度、进样时间和等速电泳时间等重要因素。选择在400 mmol/L LiAc-HAc缓冲液(pH 4.5)和400 mmol/L β-丙氨酸-HAc尾随液(pH 4.5)及10 kV下样品和尾随溶液电动注入时间分别为270和90 s的条件下对高盐溶液中两种结构相近的药物普萘洛尔和美托洛尔进行了富集和分离。该方法富集倍数约为常规电动进样的280倍,普萘洛尔和美托洛尔的检出限分别为2×10-3和8×10-3 mg/L。  相似文献   

17.
A new multi‐stacking pre‐concentration procedure based on field‐enhanced sample injection (FESI), field‐amplified sample stacking, and transient isotachophoresis was developed and implemented in a compact microchip electrophoresis (MCE) with a double T‐junction glass chip, coupled with an on‐chip capacitively coupled contactless conductivity detection (C4D) system. A mixture of the cationic target analyte and the terminating electrolyte (TE) from the two sample reservoirs was injected under FESI conditions within the two sample‐loading channels. At the double T‐junction, the stacked analyte zones were further concentrated under field‐amplified stacking conditions and then subsequently focused by transient‐isotachophoresis and separated along the separation channels. The proposed multi‐stacking strategy was verified under a Universal Serial Bus (USB) fluorescence microscope employing Rhodamine 6G as the model analyte. This developed approach was subsequently used to monitor the target quinine present in human plasma samples. The total analysis time for quinine was approximately 200 s with a sensitivity enhancement factor of approximately 61 when compared to the typical gated injection. The detection and quantification limits of the developed approach for quinine were 3.0 μg/mL and 10 μg/mL, respectively, with intraday and interday repeatability (%RSDs, n = 5) of 3.6 and 4.4%. Recoveries in spiked human plasma were 98.1–99.8%.  相似文献   

18.
Online sample concentration or stacking of basic drugs by transient isotachophoresis with the injection of an acid in co-electroosmotic flow capillary zone electrophoresis was studied experimentally and with computer simulation. The acid stacking strategy afforded an order of magnitude improvement in concentration sensitivity for model tricyclic antidepressant and β blocker drugs.  相似文献   

19.
This paper presents the findings of a feasibility study investigating the behaviour of DNA under conditions of miniaturised isotachophoresis. An electrolyte system comprising a leading electrolyte of 5mM perchloric acid at pH 6.0 and a terminating electrolyte of 10mM gallic acid was devised and used to perform isotachophoresis of DNA containing samples on a miniaturised poly(methyl methacrylate) device. Under such conditions it was found that no separation of DNA fragments was observed with the substance migrating instead as a single isotachophoretic zone. Whilst such a result shows the method is unsuitable for analysis DNA it offers significant potential as a means of sample preparation for subsequent analysis using another method. This is because the single zone of DNA formed is preconcentrated to a constant concentration governed by the leading ion and is separated from all species with different effective electrophoretic mobilities.  相似文献   

20.
Wang J  Zhang Y  Okamoto Y  Kaji N  Tokeshi M  Baba Y 《The Analyst》2011,136(6):1142-1147
Online automatic transient isotachophoresis concentration of DNA-aptamer and its thrombin complex by using one kind of pseudo-terminating electrolyte buffer in a cross-channel poly(methyl methacrylate) microchip is reported. Sample injection, transient concentration and separation were done continuously and controlled by a sequential voltage switching program, time-consuming steps and complicated chip design were not required. Peak resolution between DNA-aptamer and its thrombin complex was influenced by this novel pseudo-terminating electrolyte buffer, which was prepared by the addition of chemical component with slow mobility into the same buffer as leading electrolyte buffer. 1100-fold signal enhancement of thrombin complex was achieved by this transient isotachophoresis on a standard cross-form microchip. The concentration effect or standing time of transient isotachophoresis was proved to be influenced by the concentration of leading electrolyte ion and the concentration of pseudo-terminating electrolyte buffer ion (glycine). The transient concentration was followed by on-chip nondenaturing gel electrophoresis in methylcellulose solution for the size-based separation. The detection limit, taken as the lowest thrombin concentration at threefold S/N, was determined to be 0.5 amol in mass by this method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号