首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An on-line Hg reduction technique using stannous chloride as the reductant was applied for accurate and precise mercury isotope ratio determinations by multi-collector (MC)-ICP/MS. Special attention has been paid to ensure optimal conditions (such as acquisition time and mercury concentration) allowing precision measurements good enough to be able to significantly detect the anticipated small differences in Hg isotope ratios in nature. Typically, internal precision was better than 0.002% (1 RSE) on all Hg ratios investigated as long as approximately 20 ng of Hg was measured with a 10-min acquisition time. Introducing higher amounts of mercury (50 ng Hg) improved the internal precision to <0.001%. Instrumental mass bias was corrected using 205Tl/203Tl correction coupled to a standard-sample bracketing approach. The large number of data acquired allowed us to validate the consistency of our measurements over a one-year period. On average, the short-term uncertainty determined by repeated runs of NIST SRM 1641d Hg standard during a single day was <0.006% (1 RSD) for all isotope pairs investigated (202Hg/198Hg, 202Hg/199Hg, 202Hg/200Hg, and 202Hg/201Hg). The precision fell to <0.01% if the long-term reproducibility, taken over 11 months (over 100 measurements), was considered. The extent of fractionation has been investigated in a series of sediments subject to various Hg sources from different locations worldwide. The ratio 202Hg/198Hg expressed as δ values (per mil deviations relative to NIST SRM 1641d Hg standard solution) displayed differences from +0.74 to −4.00‰. The magnitude of the Hg fractionation per amu was constant within one type of sample and did not exceed 1.00‰. Considering all results (the reproducibility of Hg standard solutions, reference sediment samples, and the examination of natural samples), the analytical error of our δ values for the overall method was within ±0.28‰ (1 SD), which was an order of magnitude lower than the extent of fractionation (4.74‰) observed in sediments. This study confirmed that analytical techniques have reached a level of long-term precision and accuracy that is sufficiently sensitive to detect even small differences in Hg isotope ratios that occur within one type of samples (e.g., between different sediments) and so far have unequivocally shown that Hg isotope ratios in sediments vary within approximately 5‰.  相似文献   

2.
Isotope ratio measurements characterizing 202Hg/200Hg in NIST SRM 3133 Mercury Standard Solution were undertaken by multicollector inductively coupled plasma mass spectrometry employing NIST SRM 997 Tl for mass bias correction by use of the slope and the intercept obtained from a natural logarithmic plot of each session of measurements of 202Hg/200Hg against 205Tl/203Tl. The calculated value of 1.285333 ± 0.000192 (mean and one standard deviation, n = 40) for the mass bias corrected 202Hg/200Hg was then used for mass bias correction of other Hg isotope pairs. Ratios of 0.015337 ± 0.000011, 1.68770 ± 0.00054, 2.3056 ± 0.0015, 1.3129 ± 0.0013, 2.9634 ± 0.0038, and 0.67937 ± 0.0013 (expanded uncertainty, k = 2) were obtained for 196Hg/198Hg, 199Hg/198Hg, 200Hg/198Hg, 201Hg/198Hg, 202Hg/198Hg, and 204Hg/198Hg, respectively. Reduction of Hg(II) to Hg0 in solutions of SRM 3133 was then undertaken using SnCl2, NaBH4, UV photolysis in the presence of formic acid, and ethylation of Hg(II) using NaBEt4. These reactions induced significant isotope fractionation with maximum values of 1.17 ± 0.07, 1.08 ± 0.09, 1.34 ± 0.07, and 3.59 ± 0.09‰ (one standard deviation, 1SD, n = 5) for δ 202/198Hg relative to the initial isotopic composition in the solution following 85–90% reduction of the Hg by SnCl2, NaBH4, UV photolysis, and ethylation with NaBEt4, respectively. Mass-dependent fractionation was found to be dominant for all reduction processes. Figure Mass dependence of fractionation for all samples from Hg fractionation experiments using NaBEt4. Solid lines are the theoretically predicted MDF based on δ202/198 Hg using equation 7. Error bars displayed are one standard deviation of the mean of 5 measurements of each sample  相似文献   

3.
High-precision Mg isotope measurements by multiple collector inductively coupled plasma mass spectrometry were applied for determinations of magnesium isotopic fractionation of biogenic calcium carbonates from seawater with a rapid Mg purification technique. The mean δ26Mg values of scleractinian corals, giant clam, benthic foraminifera, and calcite deep-sea corals were −0.87‰, −2.57‰, −2.34‰, and −2.43‰, suggesting preferential precipitation of light Mg isotopes to produce carbonate skeleton in biomineralization. Mg isotope fractionation in deep-sea coral, which has high Mg calcite skeleton, showed a clear temperature (T) dependence from 2.5 °C to 19.5 °C: 1,000 × ln(α) = −2.63 (±0.076) + 0.0138 (±0.0051) × T(R 2 = 0.82, p < 0.01). The δ26Mg values of large benthic foraminifera, which are also composed of a high-Mg calcite skeleton, can be plotted on the same regression line as that for deep-sea coral. Since the precipitation rates of deep-sea coral and benthic foraminifera are several orders of magnitude different, the results suggest that kinetic isotope fractionation may not be a major controlling factor for high-Mg calcite. The Mg isotope fractionation factors and the slope of temperature dependence from deep-sea corals and benthic foraminifera are similar to that for an inorganically precipitated calcite speleothem. Taking into account element partitioning and the calcification rate of biogenic CaCO3, the similarity among inorganic minerals, deep-sea corals, and benthic foraminiferas may indicate a strong mineralogical control on Mg isotope fractionation for high-Mg calcite. On the other hand, δ26Mg in hermatypic corals composed of aragonite has been comparable with previous data on biogenic aragonite of coral, sclerosponges, and scaphopad, regardless of species differences of samples.  相似文献   

4.
Hg stable isotope analysis by the double-spike method   总被引:2,自引:0,他引:2  
Recent publications suggest great potential for analysis of Hg stable isotope abundances to elucidate sources and/or chemical processes that control the environmental impact of mercury. We have developed a new MC-ICP-MS method for analysis of mercury isotope ratios using the double-spike approach, in which a solution containing enriched 196Hg and 204Hg is mixed with samples and provides a means to correct for instrumental mass bias and most isotopic fractionation that may occur during sample preparation and introduction into the instrument. Large amounts of isotopic fractionation induced by sample preparation and introduction into the instrument (e.g., by batch reactors) are corrected for. This may greatly enhance various Hg pre-concentration methods by correcting for minor fractionation that may occur during preparation and removing the need to demonstrate 100% recovery. Current precision, when ratios are normalized to the daily average, is 0.06‰, 0.06‰, 0.05‰, and 0.05‰ (2σ) for 202Hg/198Hg, 201Hg/198Hg, 200Hg/198Hg, and 199Hg/198Hg, respectively. This is slightly better than previously published methods. Additionally, this precision was attained despite the presence of large amounts of other Hg isotopes (e.g., 5.0% atom percent 198Hg) in the spike solution; substantially better precision could be achieved if purer 196Hg were used.  相似文献   

5.
A new double-spiking approach, based on a multiple-spiking numerical methodology, has been developed and applied for the accurate quantification of inorganic mercury (IHg) and methylmercury (MeHg) by GC–ICPMS in different environmental matrices such as water, sediments and a wide range of biological tissues. For this purpose, two enriched mercury species (201MeHg and 199IHg) were added to the samples before sample preparation in order to quantify the extents of the methylation and demethylation processes, and thereby correct the final species concentrations. A critical evaluation of the applicability of this methodology was performed for each type of matrix, highlighting its main advantages and limitations when correcting for the conversion reactions of the species throughout the whole sample preparation procedure. The double-spike isotope dilution (DSIDA) methodology was evaluated by comparing it with conventional species specific isotope dilution (IDA) when analysing both certified reference materials and environmental samples (water, biotissues and sediment). The results demonstrate that this methodology is able to provide both accurate and precise results for IHg and MeHg when their relative concentrations are not too different (ratio MeHg/IHg > 0.05), a condition that holds for most natural waters and biotissues. Significant limitations on the accurate and precise determination of the demethylation factor are however observed, especially for real sediment samples in which the relative concentrations of the species are substantially different (ratio MeHg/IHg < 0.05). A determination of the sources of uncertainty in the methylation/demethylation factors has demonstrated that the accurate and precise measurement of the isotope ratios in the species involved in the transformations is crucial when quantifying the extents of these reactions. Although the double-spike methodology is established as a reference approach that permits the correction of most analytical biases and the accurate quantification of Hg species, some limitations have been identified for the first time in this work.  相似文献   

6.
A new cod fish tissue certified reference material, NMIJ CRM 7402-a, for methylmercury analysis was certified by the National Metrological Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Cod fish was collected from the sea close to Japan. The cod muscle was powdered by freeze-pulverization and was placed into 600 glass bottles (10 g each), which were sterilized with γ-ray irradiation. The certification was carried out using species-specific isotope dilution gas chromatography inductively coupled plasma mass spectrometry (SSID–GC–ICPMS), where 202Hg-enriched methylmercury (MeHg) was used as the spike compound. In order to avoid any possible analytical biases caused by nonquantitative extraction, degradation and/or formation of MeHg in sample preparations, two different extraction methods (KOH/methanol and HCl/methanol extractions) were performed, and one of these extraction methods utilized two different derivatization methods (ethylation and phenylation). A double ID method was adopted to minimize the uncertainty arising from the analyses. In order to ensure not only the reliability of the analytical results but also traceability to SI units, the standard solution of MeHg used for the reverse-ID was prepared from high-purity MeHg chloride and was carefully assayed as follows: the total mercury was determined by ID–ICPMS following aqua regia digestion, and the ratio of Hg as MeHg to the total Hg content was estimated by GC–ICPMS. The certified value given for MeHg is 0.58 ± 0.02 mg kg−1 as Hg. Figure NMIJ CRM 7402-a: cod fish tissue for MeHg analysis  相似文献   

7.
Methyl-branched fatty acids (MBFAs) are the dominant form of fatty acid found in many bacteria. They are also found at low levels in a range of foodstuffs, where their presence has been linked to bacterial sources. In this study we evaluated the potential of compound-specific isotope analysis to obtain insights into the stable carbon isotope ratios (δ13C values in ‰) of individual MBFAs and to compare them to the stable carbon isotope ratios of straight-chain fatty acids in food. Due to their low abundance in foodstuffs, the MBFAs were enriched prior to gas chromatography coupled to isotope ratio mass spectrometric (GC–IRMS) analysis. After transesterification, urea complexation was used to suppress the 16:0 and 18:0 methyl esters that were dominant in the samples. Following that, silver-ion high performance liquid chromatography was used to separate the saturated from the unsaturated fatty acids. The resulting solutions of saturated fatty acids obtained from suet, goat’s milk, butter, and human milk were studied by GC–IRMS. The δ13C values of fatty acids with 12–17 carbons ranged from −25.4‰ to −37.6‰. In all samples, MBFAs were most depleted in carbon-13, followed by the odd-chain fatty acids 15:0 and 17:0. 14:0 and 16:0 contained the highest proportions of carbon-13. The results from this study illustrate that MBFAs have distinctive δ13C values and must originate from other sources and/or from very different substrates. These measurements support the initial hypothesis that δ13C values can be used to attribute MBFAs to particular sources.  相似文献   

8.
Follow-up of stable isotope analysis of organic versus conventional milk   总被引:1,自引:0,他引:1  
Analysis of the stable isotope ratio of carbon (δ 13C) and α-linolenic acid (C18:3ω3) content in milk fat is a useful indicator of organic milk production. Referring to corresponding measurements, further analyses of stable isotope ratios were performed in 120 samples of conventionally and organically produced whole milk collected from German retailers during a period of 18 months. Conventional milk predominantly exhibited higher δ 15N values than organic milk, the latter of which never exceeded a maximum δ 15N threshold value of 5.50‰. Measurements of δ 34S did not differ significantly between organic and conventional milk. Because δ 13C, in general, is related to maize consumption, δ 13C in milk protein and δ 13C in milk fat were equally suited for authentication of organic milk. Thus, a high correlation (r = 0.99) was established between δ 13C in milk protein and lipids. Although occurring on different levels in organic and conventional milk, the relatively constant fractionation of carbon isotopes between protein and fat will allow for the advanced detection of adulteration in processed milk products, such as fraudulent combinations of organic milk fat and conventional skim milk. In addition to the strong correlation between C18:3ω3 and δ 13Cprotein (r = −0.91), a mutual dependence was identified between both δ 13Cprotein and δ 15N (r = 0.66) and C18:3ω3 and δ 15N (r = −0.61). Thus, multi-variable analyses are useful to increase robustness and reduce the number of exceptions in organic milk authentication. Future work involving multivariate statistical analysis can possibly further improve milk authentication in various respects including differentiating between brands of retail milk.  相似文献   

9.
Microwave digestion and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-SFMS) has been applied to the determination of Pb in rice flour. In order to achieve highly precise determination of low concentrations of Pb, the digestion blank for Pb was reduced to 0.21 ng g−1 after optimization of the digestion conditions, in which 20 mL analysis solution was obtained after digestion of 0.5 g rice flour. The observed value of Pb in a non-fat milk powder certified reference material (CRM), NIST SRM 1549, was 16.8 ± 0.8 ng g−1 (mean ± expanded uncertainty, k = 2; n = 5), which agreed with the certified value of 19 ± 3 ng g−1 and indicated the effectiveness of the method. Analytical results for Pb in three brown rice flour CRMs, NIST SRM 1568a, NIES CRM 10-a, and NIES CRM 10-b, were 7.32 ± 0.24 ng g−1 (n = 5), 1010 ± 10 ng g−1 (n = 5), and 1250 ± 20 ng g−1 (n = 5), respectively. The concentration of Pb in a candidate white rice flour reference material (RM) sample prepared by the National Metrology Institute of Japan (NMIJ) was observed to be 4.36 ± 0.28 ng g−1 (n = 10 bottles). Figure Digestion blank of Pb was carefully reduced to approximately 0.2 ng g-1 which permitted the highly precise determination of Pb at low ng g-1 level in foodstuff samples by ID-SFMS  相似文献   

10.
An important route for the detoxification of tropane alkaloids involves N-demethylation to the nor-compounds followed by further degradation. In order to study the mechanisms of the pertinent reactions, a suitable means to determine the isotope ratios of the substrates and products is required. However, the polarity and functionality of the nortropane compounds makes their analysis as free bases difficult. A method is described which allows both the quantification of nortropane alkaloids and the determination of their natural abundance δ15N values. The protocol exploits the derivatisation of the alkaloids by reaction with ethyl chloroformate in aqueous medium and the quantitative extraction of the ensuing ethylcarbamate esters. The improved chromatographic properties of these derivatives gives ample separation of the isomeric nortropine and norpseudotropine for measurement of their δ15N (‰) values by isotope ratio mass spectrometry interfaced to gas chromatography. Adequate separation could not be achieved with the underivatised compounds. Repeatability and precision are sufficient to allow differences in the δ15N values (∆δ15N) > 0.8‰ to be measured, with a standard deviation routinely ∼0.3‰. The methodology has been tested by determining the changes in the δ15N values of nortropine and norpseudotropine during degradation by cell suspension cultures of a Pseudomonas strain expressing a specific capacity for tropine catabolism. The precision and reproducibility are shown sufficient to allow the evolution of the δ15N values to be followed during the fermentation.  相似文献   

11.
A multicommutation-based flow system with photometric detection was developed, employing an analytical microsystem constructed with low temperature co-fired ceramics (LTCC) technology, a solid-phase reactor containing particles of Canavalia ensiformis DC (urease source) immobilized with glutaraldehyde, and a mini-photometer coupled directly to the microsystem which monolithically integrates a continuous flow cell. The determination of urea in milk was based on the hydrolysis of urea in the solid-phase reactor and the ammonium ions produced were monitored using the Berthelot reaction. The analytical curve was linear in the urea concentration range from 1.0 × 10−4 to 5.0 × 10−3 mol L−1 with a limit of detection of 8.0 × 10−6 mol L−1. The relative standard deviation (RSD) for a 2.0 × 10−3 mol L−1 urea solution was lower than 0.4% (n = 10) and the sample throughput was 13 h−1. To check the reproducibility of the flow system, calibration curves were obtained with freshly prepared solutions on different days and the RSD obtained was 4.7% (n = 6). Accuracy was assessed by comparing the results of the proposed method with those from the official procedure and the data are in close agreement, at a 95% confidence level.  相似文献   

12.
Mercury tracers are powerful tools that can be used to study mercury transformations in environmental systems, particularly mercury methylation, demethylation and reduction in sediments and water. However, mercury transformation studies using tracers can be subject to error, especially when used to assess methylation potential. The organic mercury extracted can be as low as 0.01% of the endogenous labeled mercury, and artefacts and contamination present during methylmercury (MeHg) extraction processes can cause interference. Solvent extraction methods based on the use of either KBr/H2SO4 or HCl were evaluated in freshwater sediments using 197Hg radiotracer. Values obtained for the 197Hg tracer in the organic phase were up to 25-fold higher when HCl was used, which is due to the coextraction of 197Hg2+ into the organic phase during MeHg extraction. Evaluations of the production of MeHg gave similar results with both MeHg extraction procedures, but due to the higher Hg2+ contamination of the controls, the uncertainty in the determination was higher when HCl was used. The Hg2+ contamination of controls in the HCl extraction method showed a nonlinear correlation with the humic acid content of sediment pore water. Therefore, use of the KBr/H2SO4 method is recommended, since it is free from these interferences. 197Hg radiotracer (T 1/2 = 2.673 d) has a production rate that is about 50 times higher than that of 203Hg (T 1/2 = 46.595 d), the most frequently used mercury radiotracer. Hence it is possible to obtain a similar level of performance to 203Hg when it is used it in short-term experiments and produced by the irradiation of 196Hg with thermal neutrons, using mercury targets with the natural isotopic composition. However, if the 0.15% natural abundance of the 196Hg isotope is increased, the specific activity of the 197Hg tracer can be significantly improved. In the present work, 197Hg tracer was produced from mercury 51.58% enriched in the 196Hg isotope, and a 340-fold increase in specific activity with respect to natural mercury targets was obtained. When this high specific activity tracer is employed, mercury methylation and reduction experiments with minimum mercury additions are feasible. Tracer recovery in methylation experiments (associated with Me197Hg production from 197Hg2+ spike, but also with Hg2+ contamination and Me197Hg artefacts) with marine sediments was about 0.005% g−1 WS (WS: wet sediment) after 20 h incubation with mercury additions of 0.05 ng g−1 WS, which is far below natural mercury levels. In this case, the amount of Hg2+ reduced to Hg0 (expressed as the percent 197Hg0 recovered with respect to the 197Hg2+ added) varied from 0.13 to 1.6% g−1 WS. Me197Hg production from 197Hg2+ spike after 20 h of incubation of freshwater sediment ranged from 0.02 to 0.13% g−1 WS with mercury additions of 2.5 ng g−1 WS, which is also far below natural levels. 197Hg0 recoveries were low, 0.0058 ± 0.0013% g−1 WS, but showed good reproducibility in five replicates. Me197Hg production from 197Hg2+ spiked in freshwater samples ranged from 0.1 to 0.3% over a period of three days with mercury additions of 10 ng L−1. A detection limit of 0.05% for Me197Hg production from 197Hg2+ spike was obtained in seawater in a 25 h incubation experiment with mercury additions of 12 ng L−1.  相似文献   

13.
The analytical performance of five sample introduction systems, a cross flow nebulizer spray chamber, two different solvent desolvation systems, a multi-mode sample introduction system (MSIS), and a hydride generation (LI2) system were compared for the determination of Se isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS). The optimal operating parameters for obtaining the highest Se signal-to-noise (S/N) ratios and isotope ratio precision for each sample introduction were determined. The hydride generation (LI2) system was identified as the most suitable sample introduction method yielding maximum sensitivity and precision for Se isotope ratio measurement. It provided five times higher S/N ratios for all Se isotopes compared to the MSIS, 20 times the S/N ratios of both desolvation units, and 100 times the S/N ratios produced by the conventional spray chamber sample introduction method. The internal precision achieved for the 78Se/82Se ratio at 100 ng mL−1 Se with the spray chamber, two desolvation, MSIS, and the LI2 systems coupled to MC-ICP/MS was 150, 125, 114, 13, and 7 ppm, respectively. Instrument mass bias factors (K) were calculated using an exponential law correction function. Among the five studied sample introduction systems the LI2 showed the lowest mass bias of −0.0265 and the desolvation system showed the largest bias with −0.0321. Figure Illustration of the multi-mode sample introduction system for Se isotope ratiomeasurements  相似文献   

14.
A new method was proposed for the accurate determination of mercury in cosmetic samples based on isotopic dilution (ID)-photochemical vapor generation (PVG)-inductively coupled plasma mass spectrometry (ICP MS) measurement. Cosmetic samples were directly dissolved in formic acid solution and subsequently subjected to PVG for the reduction of mercury into vapor species following by ICP MS detection. Therefore, the risks of analyte contamination and loss were avoided. Highly enriched 201Hg isotopic spike is added to cosmetics and the isotope ratios of 201Hg/202Hg were measured for the quantitation of mercury. With ID calibration, the influences originating from sample matrixes for the determination of mercury in cosmetic samples have been efficiently eliminated. The effects of several experimental parameters, such as the concentration of the formic acid, and the flow rates of carrier gas and sample were investigated. The method provided good reproducibility and the detection limits were found to be 0.6 pg mL−1. Finally, the developed method was successfully applied for the determination of mercury in six cosmetic samples and a spike test was performed to verify the accuracy of the method.  相似文献   

15.
The quality of the determination of compound-specific isotopic content at natural abundance by gas chromatography–isotope ratio measurement–mass spectrometry (GC-irm-MS) relies on the stability of the voltage generated by the ion detector Faraday cages. The application of GC-irm-MS to the determination of δ13C (‰) and δ15N (‰) is now routine. However, for numerous applications, it is necessary to determine both the isotope content (δ15N) and the quantity (in micromoles) of analyte present. We now show that it is possible for nitrogen-containing compounds to measure how much analyte is present with an irm mass spectrometer linked to a GC by exploiting the integrated N2 total ion current intensity (Vs) generated by measuring the 15N/14N isotope ratio. The method is validated over a range of concentration (2–70 mmol/L) and δ15N (−70 to +50‰) values for six molecules of diverse chemical nature and functionality (nortropine, norpseudotropine, nortropinone, cysteine, taurine, glutathione). It is shown that once the ion current is calibrated, the quantitative values are of a comparable quality to those obtained from GC with flame ionization detection (GC-FID). In addition, it is demonstrated that over a definable range, the δ15N (‰) value is independent of the quantity of analyte introduced, confirming the validity of this method.  相似文献   

16.
Precision and accuracy of lead isotope ratios of a volatile lead species (PbEt4) were determined by coupling a capillary GC to a magnetic sector multicollector ICP-MS. PbEt4 was prepared by ethylation of a certified lead isotope solution (NIST SRM 981). Coupling was achieved by a transfer line, which allowed simultaneous introduction of a thallium standard solution to correct for mass discrimination. Seven isotopes (202Hg, 203Tl, 204Pb, 205Tl, 206Pb, 207Pb, 208Pb) were monitored simultaneously with a transient resolution of 50 ms. Pb isotope ratios for the PbEt4 peaks were calculated using transient peak integrals of each isotope signal. Absolute detection limits were 20 (204Pb), 0.7 (206Pb), 1 (207Pb) and 0.3 pg (208Pb). Precision was assessed for five replicate injections of PbEt4 in iso-octane, corresponding to a total amount of 300 pg of Pb. Precision of isotope ratios for 206Pb, 207Pb and 208Pb were better than 0.07% (RSD), with ratios including 204Pb being one order of magnitude worse. Accuracy using mass bias correction via 203Tl/205Tl ranged from 0.18% for 208Pb/206Pb to 0.9% for 208Pb/204Pb.  相似文献   

17.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples. Received: 1 December 1998 / Revised: 25 January 1999 / Accepted: 31 January 1999  相似文献   

18.
Compound-specific stable isotope analysis (CSIA) using gas chromatography-isotope ratio mass spectrometry (GC/IRMS) has developed into a mature analytical method in many application areas over the last decade. This is in particular true for carbon isotope analysis, whereas measurements of the other elements amenable to CSIA (hydrogen, nitrogen, oxygen) are much less routine. In environmental sciences, successful applications to date include (i) the allocation of contaminant sources on a local, regional, and global scale, (ii) the identification and quantification of (bio)transformation reactions on scales ranging from batch experiments to contaminated field sites, and (iii) the characterization of elementary reaction mechanisms that govern product formation. These three application areas are discussed in detail. The investigated spectrum of compounds comprises mainly n-alkanes, monoaromatics such as benzene and toluene, methyl tert-butyl ether (MTBE), polycyclic aromatic hydrocarbons (PAHs), and chlorinated hydrocarbons such as tetrachloromethane, trichloroethylene, and polychlorinated biphenyls (PCBs). Future research directions are primarily set by the state of the art in analytical instrumentation and method development. Approaches to utilize HPLC separation in CSIA, the enhancement of sensitivity of CSIA to allow field investigations in the µg L–1 range, and the development of methods for CSIA of other elements are reviewed. Furthermore, an alternative scheme to evaluate isotope data is outlined that would enable estimates of position-specific kinetic isotope effects and, thus, allow one to extract mechanistic chemical and biochemical information.Abbreviations BTEX benzene, toluene, ethylbenzene, xylenes - MTBE methyl tert-butyl ether - PAHs polycyclic aromatic hydrocarbons - VOCs volatile compounds - PCBs polychlorinated biphenyls - CSIA compound-specific (stable) isotope (ratio) analysis - GC-IRMS, GC/IRMS or GCIRMS gas chromatography-isotope ratio mass spectrometry - GC-C-IRMS, GC/C/IRMS or GCC-IRMS gas chromatography-combustion-isotope ratio mass spectrometry - irmGC/MS isotope ratio monitoring gas chromatograph-mass spectrometry - GC/P/IRMS gas chromatography-pyrolysis-isotope ratio mass spectrometry (used for D/H) - KIE kinetic isotope effect - PSIA position-specific isotope analysis (for intramolecular isotope distribution) - SNIF-NMR site-specific natural isotopic fractionation by nuclear magnetic resonance spectroscopy  相似文献   

19.
An improved and novel sample preparation method for 226Ra determination in liquid samples by isotope dilution inductively coupled plasma sector field mass spectrometry using laboratory-prepared 228Ra tracer has been developed. The procedure involves a selective preconcentration achieved by applying laboratory-prepared MnO2 resin followed by cation exchange chromatographic separation. In order to completely eliminate possible molecular interferences, medium mass resolution (R = 4,000) combined with chemical separation was found to be a good compromise that enhanced the reliability of the method. The detection limit of 0.084 fg g−1 (3.1 mBq kg−1) achieved is comparable to that of the emanation method or alpha spectrometry and is suitable for low-level environmental measurements. The chemical recovery of the sample preparation method ranged from 72 to 94%. The proposed method enables a rapid, accurate and less labor-intensive approach to routine environmental 226Ra determination than the radioanalytical techniques conventionally applied.  相似文献   

20.
A method for the accurate determination of ultratrace selenium species of relevance to cancer research, such as gamma-glutamyl-Se-methylselenocysteine (γ-glutamyl-SeMC), using species-specific double isotope dilution analysis (IDA) with HPLC–ICP–MS is reported for the first time. The 77Se-enriched γ-glutamyl-SeMC spike was produced in-house by collecting the fraction at the retention time of the γ-glutamyl-SeMC peak from a chromatographed aqueous extract of 77Se-enriched yeast, pooling the collected fractions and freeze-drying the homogenate. The Se content of this spike was characterised using reverse isotope dilution mass spectrometry (IDMS) and the isotopic composition of this spike was checked prior to quantification of the natural abundance dipeptide species in garlic using speciated IDA. The extraction of the γ-glutamyl-SeMC species in water was performed in a sonication bath for 2 h after adding an appropriate quantity of 77Se-enriched γ-glutamyl-SeMC to 50 mg of garlic to give optimal 78Se/77Se and 82Se/77Se ratios of 1.5 and 0.6, respectively. The effect of ultrasonic nebulisation, in comparison with the loading of the ICP with carbon (through the addition of methane gas on-line), on the detection of Se associated with γ-glutamyl-SeMC using collision/reaction cell ICP–MS with hydrogen as collision gas was investigated. Sensitivity enhancements of approximately fourfold and twofold were achieved using USN and methane mixed plasma, respectively, in comparison with conventional nebulisation and conventional Ar ICP–MS. However, an approximately twofold improvement in the detection limit was achieved using both approaches (42 ng kg−1 for 78Se using peak height measurements). The use of species-specific IDMS enabled quantification of the dipeptide species at ng g−1 levels (603 ng g−1 Se) in the complex food matrix with a relative standard deviation (RSD, n = 4) of 4.5%, which was approximately half that obtained using standard addition as a confirmatory technique. Furthermore, good agreement was found between the γ-glutamyl-SeMC species concentrations obtained using both calibration methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号