1.
A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and 365 nm for mangiferin in plasma and urine, respectively. The limit of quantitation (LOQ) of mangiferin was 0.6 microg/mL in plasma, and 0.48 microg/mL in urine. The standard curve was linear from 0.6 to 24 microg/mL in plasma, and 0.48 to 24 microg/mL in urine, both intra- and inter-day precision of the mangiferin were determined and their RSD did not exceed 10%. The method provides a technique for rapid analysis of mangiferin in rat plasma and urine, which can be used in pharmacokinetic studies.  相似文献   

2.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

3.
A simple, rapid and sensitive method for the determination of iothalamic acid (IA) in both plasma and urine is reported. After extraction with ethyl acetate, IA was determined by strong anion-exchange high-performance liquid chromatography with ultraviolet detection at 254 nm. The lower limit of detection was 0.5 micrograms/ml. The average recovery was 73 and 57% from plasma and urine, respectively. Linearity was found over the investigated concentration range (up to 500 micrograms/ml for plasma and up to 10.0 mg/ml for urine). The reproducibility of the technique was good (coefficient of variation less than 6%) as was the precision and accuracy (coefficient of variation less than 2.5%). No interference from endogenous substances or any of the common drugs tested was found.  相似文献   

4.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

5.
A sensitive, selective and easy to use high-performance liquid chromatographic method for the determination of cicletanide, a new diuretic, in plasma, red blood cells, urine and saliva is described. After extraction of cicletanide together with an internal standard with diethyl ether, or diethyl ether-n-hexane (20:80) for urine, the sample extracts are chromatographed with water-methanol-acetic acid (50:50:0.3) as eluent on to a Nucleosil C18 column. Both compounds are detected by their ultraviolet absorption at 280 nm. The calibration graph was linear between 0.2 and 20 micrograms/ml for plasma and between 0.2 and 5 micrograms/ml for the other biological fluids. The sensitivity limit was 20 ng/ml for plasma, red blood cells and saliva and 30 ng/ml for urine. The coefficients of variation of the between-day assays did not exceed 4.6% in plasma, 8.3% in red blood cells, 7.8% in urine and 4.2% in saliva for the lowest concentrations studied. The application of the method to a pharmacokinetic study of cicletanide after a single oral therapeutic dose in humans is reported.  相似文献   

6.
A gradient elution high-performance liquid chromatographic method is described for the analysis of the beta-lactamase inhibitor tazobactam (YTR-830H) and a semi-synthetic parenteral penicillin, piperacillin, in human plasma, serum, bile and urine. The assay for plasma, serum and bile involves deproteinization with acetonitrile and the removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantitation are achieved using a mobile phase based on ion-suppression chromatography on a C18 reversed-phase column with ultraviolet detection at 220 nm. The limit of quantitation for both compounds is 1.0 microgram/ml in plasma, serum and bile using a 0.2-ml sample and 50.0 micrograms/ml in urine using a 0.1-ml sample. The method has been validated by preparing and analyzing a series of fortified samples (range 1.0-200 micrograms/ml for each compound in plasma, serum and bile and 50.0-10,000 micrograms/ml for each compound in urine). Excellent linearity, accuracy, precision and recovery were obtained. The method was not interfered with by other endogenous components, nor by other commonly administered antibiotics such as amoxicillin, mezlocillin, cefometazole and cefotaxime. The assay has been successfully applied to the analysis of samples from pharmacokinetic studies in man and animals.  相似文献   

7.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

8.
A sensitive, highly selective and simple high-performance liquid chromatographic method for the determination of teicoplanin, a novel glycopeptide antibiotic, composed of six components, in human plasma and urine is described. After an isolation step by affinity chromatography, the antibiotic substances were chromatographed on a Nucleosil C18 column with phosphate buffer-acetonitrile according to a gradient profile. All the components were detected by their UV absorption at 240 nm. The concentration of teicoplanin was determined by using the external standard procedure. This method was applied to the sum of the six major components as well as to each of them separately. The linearity of the method was checked between 0.5 and 50 micrograms/ml for plasma and between 2 and 50 micrograms/ml for urine. The limit of detection was 0.1 microgram/ml for both biological fluids. The coefficients of variation of the between-day assays did not exceed 8.6 and 8.9% in plasma and urine, respectively. The application of the method to a pharmacokinetic study of teicoplanin after a single intravenous therapeutic dose in a patient is reported. This rapid technique also appears to be suitable for drug monitoring.  相似文献   

9.
A simple high-performance liquid chromatographic method is presented for the determination of trace amounts of sulphadimidine (SDD), its hydroxylated metabolites and N4-acetyl-SDD in blood plasma, urine, hepatocyte culture media and microsomal incubations. The synthesis of 5-hydroxy-SDD and an improved method for the isolation of 4-methylhydroxy-SDD from urine are described and their respective specific absorption coefficients at 265 nm are calculated by on-line radiochemical and ultraviolet detection. The limit of detection of the analytical method is 0.05 micrograms/ml for SDD and its hydroxy metabolites and 0.2 micrograms/ml for N4-acetyl-SDD. Linear calibration graphs for SDD and its metabolites were constructed from 0.2 to 50 micrograms/ml. The method has been applied to biotransformation studies in vivo and in vitro.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) method for the determination of sulbactam in human and rat plasma and urine has been developed. Sulbactam was reacted with 1,2,4-triazole to yield a product having an ultraviolet absorption maximum at 326 nm. The product was separated using reversed-phase HPLC from the regular components of plasma and urine with an ion-pair buffer at 50 degrees C and detected at the ultraviolet maximum. The limits of accurate determination were 0.2 and 1.0 micrograms/ml in plasma and urine, respectively. The coefficients of variation of inter- and intra-assays in human plasma spiked at 4.0 micrograms/ml (n = 5) were 1.02 and 3.05%, respectively. Coexisting cefoperazone, penicillins, or the alkaline degradation product(s) of sulbactam did not interfere in the sulbactam assay. The pharmacokinetic behaviour of sulbactam and cefoperazone coadministered to rats was estimated by moment analysis.  相似文献   

11.
An assay for the selective quantification of pseudoephedrine in human plasma and urine was developed using high-performance liquid chromatography with UV detection at 205 nm. Analyte and internal standard were extracted from alkaline plasma or urine into a mixture of n-hexane and diethyl ether, and the organic phase was back-extracted into dilute acid. The chromatographic system comprises microparticulate cyanopropyl-silica as stationary phase and a ternary solvent mixture with ion-pair reagents as mobile phase. Using 0.25 ml plasma, the lower limit of quantification was 25 ng/ml with excellent linearity up to 1000 ng/ml. In urine, the calibration ranged from 2.5 to 100 micrograms/ml. The selectivity of the method was demonstrated for several pharmaceuticals with similar structures. The validated method was applied to a pharmacokinetic study with a single oral dose of 100 mg of pseudoephedrine in two galenic formulations. Precision and accuracy data of the assay and calculated pharmacokinetic parameters are presented.  相似文献   

12.
An isocratic reversed-phase ion-pair liquid chromatographic method for the determination of tianeptine and its two main metabolites in plasma, urine and tissues, using an internal standard, is reported. The influence of two stationary phases on the retention of the drugs was studied. The drugs were extracted as ion pairs, using a heptane-octanol-tetraheptylammonium bromide mixture (98:2:0.5, v/v/w) as extraction solvent. This extraction procedure yielded plasma drug recoveries of greater than 60% and allowed UV detection at 220 nm without interference from endogenous components of plasma, urine or tissues. Linear standard curves up to 1.00 micrograms/ml and drug determination down to 0.01 microgram/ml were observed. This method has been successfully applied to the analysis of human plasma and urine samples and of encephales from tianeptine-dosed rats.  相似文献   

13.
The automated determination of amifloxacin and two of its principal metabolites in human plasma and urine by column-switching high-performance liquid chromatography is described. Plasma or urine samples, diluted 1:1 with 0.5 M sodium citrate buffer pH 2.5, were directly injected onto a cation-exchange pre-column. Following a 2.0-min wash of the pre-column with water at a flow-rate of 1.1 ml/min, the effluent from the pre-column was directed to the analytical column by a column-switching device. The precision of the plasma and urine methods ranged from a +/- 1.9 to +/- 3.6% for all compounds. The accuracies of the methods were within a range of -3.3% to 6.4% of the nominal values for all compounds. Linear responses were observed for all the standards in the range 0.10-5.0 micrograms/ml for plasma and 0.50-100 micrograms/ml for urine for all three compounds. The minimum quantifiable levels were 0.10 and 0.50 micrograms/ml for plasma and urine, respectively. The analytical methods may be used to quantify amifloxacin and the piperazinyl-N-desmethyl and piperazinyl-N-oxide metabolites in plasma and urine samples obtained from humans, monkeys, dogs and rats.  相似文献   

14.
A high-performance liquid chromatographic method has been developed for the determination of a new cephalosporin antibiotic in plasma, urine and saliva (mixed saliva) using normal-phase technique and an NH2 bonded-phase column. The eluent mixture was a combination of acetonitrile and an aqueous solution of ammonium carbonate. The rapid method involved precipitation of protein from fluids by means of acetonitrile followed by automatic injection of the supernatant. The detection limit was 0.4 micrograms/ml for plasma, 3 micrograms/ml for urine and 0.03 micrograms/ml for saliva using UV detection.  相似文献   

15.
A high-performance liquid chromatographic method is described for the analysis of the anti-bacterial agent cefotaxime and desacetylcefotaxime in physiological fluids. Plasma or serum samples were mixed with chloroform--acetone to remove proteins and most lipid material. The aqueous phase was then freeze-dried, reconstituted in mobile phase and chromatographed on a reversed-phase column using UV detection at 262 nm. Urine was analysed directly after centrifugation to remove particulate matter. The detection limit was 0.5--1.0 micrograms/ml for serum and 5 micrograms/ml for urine. The method has been applied to the analyses of cefotaxime and desacetylcefotaxime in plasma, serum, urine, cerebrospinal fluid, saliva, and pus from infected wound secretions. Two additional metabolites, which are lactones in which the beta-lactam ring has been opened, could be separated by this method.  相似文献   

16.
A method has been developed for the simultaneous determination of Tranilast, N-(3',4'-dimethoxycinnamoyl)anthranilic acid (N-5'), and metabolites in plasma and urine from humans, dogs and rodents administered N-5'. Total N-5' and metabolite N-3 conjugates were determined in human urine. Detection limits in plasma were 0.2 micrograms/ml for metabolite N-3-S and N-5' and 0.1 micrograms/ml for metabolites N-3 and N-4. In urine, detection limits were 2 micrograms/ml for metabolite N-3-S and N-5' and 1 micrograms/ml for metabolites N-3 and N-4. Metabolite N-4 was not identified in any sample assayed.  相似文献   

17.
An isocratic reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of methylmercaptopurine riboside (MMPR) in human plasma and urine is reported. Plasma samples were prepared for analysis by addition of internal standard (6-dimethylaminopurine 9-riboside) followed by extraction using disposable C18 cartridges. Urine samples were filtered through a 0.22-micron membrane prior to HPLC separation. The column effluent was monitored at 289 nm and quantitation performed using peak heights. The linear range for MMPR determination was from 10 to 500 ng/ml in plasma and from 0.25 to 50 micrograms/ml in urine. The reported method is convenient, sensitive, and reproducible, illustrating its usefulness for application in pharmacokinetic studies.  相似文献   

18.
A sensitive reversed-phase high-performance liquid chromatographic (HPLC) technique with ultraviolet detection has been developed to determine the concentration of BRB-I-28 (I), a novel antiarrhythmic agent, in dog plasma and urine. The mobile phase was acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8-triethylamine (50:50:75:0.1, v/v). The compound was extracted from dog plasma and urine with chloroform after alkalinization with sodium hydroxide. The extraction recovery was 83% from plasma and 84% from urine. Good linearity (r > 0.996) was observed throughout the ranges 0.1-12.0 micrograms/ml (plasma) and 0.1-8.0 micrograms/ml (urine). Intra- and inter-assay variabilities were less than 4%. The lower limit of quantitation was 0.08 microgram/ml in either plasma or urine. HPLC analysis of plasma and urine samples from a dog treated with I has demonstrated that the method was accurate and reproducible.  相似文献   

19.
A rapid and sensitive analytical procedure is described for the simultaneous measurement of tolmetin (T), tolmetin glucuronide (1 beta-TG) and the isomers of tolmetin glucuronide in plasma and urine. A reversed-phase liquid chromatographic system is used with an ion-pairing mobile phase of methanol-tetrabutylammonium hydrogensulfate buffered to pH 4.5 and kept at a constant temperature of 50 degrees C. Detection is by UV at 313 nm. Plasma (0.5 ml) and urine (0.1 ml) are collected in pre-cooled containers and immediately adjusted to pH 3.0 to minimize TG isomerization and hydrolysis. Samples are then deproteinated with acetonitrile, the supernatant is evaporated to dryness and reconstituted in an acetate buffer (pH 4.5), and 50 microliters are injected onto the system. Using zomepirac as the internal standard, the measurable, linear concentration ranges are 0.05-50 micrograms/ml for T in plasma and 0.025-50 micrograms/ml for T in urine. Chromatographic peaks representing T,1 beta-TG and three isomers of TG were identified, all with retention times less than 10 min. The need for special handling of biological samples is discussed.  相似文献   

20.
Determination of malotilate and its metabolites in plasma and urine   总被引:1,自引:0,他引:1  
A method for the determination of malotilate (I), the corresponding monocarboxylic acid (II) and its decarboxylated product (III) in plasma is described. Plasma was extracted with chloroform spiked with internal standard. The residue, dissolved in methanol, was chromatographed on a reversed-phase column with a mobile phase of 60% acetonitrile and 1% acetic acid in water. The sensitivity limit for I, II and III was 50, 25 and 100 ng/ml of plasma, respectively. Compound I in the same plasma extract was also analysed by gas chromatography--electron-impact mass spectrometry. The base peaks m/z 160 for I and m/z 162 for internal standard (IV) were monitored; the sensitivity limit for I was 2.5 ng/ml of plasma. The determination of the metabolites of I, II and its conjugate (V), and isopropyl-hydrogen malonate (VI) in urine by high-performance liquid chromatography is also described. The limit of quantification for VI was 2.0 micrograms/ml, and the overall coefficient of variation of VI was 4.7%. The limit of quantification for II in urine was 0.5 micrograms/ml and that for V was 1.0 micrograms/ml as total II (II + V). The overall precision of the method was satisfactory. The method was used to determine plasma and urine concentrations in four dogs orally dosed with 100, 200 or 400 mg of malotilate.  相似文献   