首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A continuous-flow procedure is proposed for the indirect determination of ascorbic acid, based on its reducing properties because of the oxidation of its 1,2-enediol group. Iron(III) was injected into a 1,10-phenanthroline stream, which was mixed with a sample carrier and then with a sodium picrate solution stream. In these conditions the iron(III) was reduced to iron(II) by the ascorbic acid. Thus, the iron(II) formed reacts with 1,10-phenanthroline to form a charged red complex, which with picrate ion forms a stable red-orange uncharged ion-association complex that is adsorbed on-line on a non-ionic polymeric adsorbent (Amberlite XAD-4), proportionally to the ascorbic acid in the sample. The unadsorbed iron was determined by flame atomic absorption spectrometry. The proposed method allows the determination of ascorbic acid in the range 0.5–25 g ml–1 with a relative standard deviation of 2.9% at a rate of ca. 90 samples h–1. This method has been applied to the determination of ascorbic acid in pharmaceutical preparations, fruit juices and sweets. The results obtained in the analysis are compared with those provided by the 2,6-dichloroindophenol method.  相似文献   

2.
Ten different digestion methods were investigated for the determination of arsenic in soils by hydride-generation atomic absorption spectrometry. These methods included a dry ashing/digestion, several acid-leaching procedures, and digestions in a pressure decomposition vessel or a Kjeldahl apparatus. A certified reference sample was analysed and the results obtained for five other soil samples were compared with the data obtained by spectrophotometry. A nitric/sulphuric acid digestion was the most suitable. A brief interference study is reported.  相似文献   

3.
A flame atomic-absorption spectrometric method is detailed for the determination of Ca, Mg, Zn, Fe, Cu, Mn, Rb and Cd in human liver tissue. Metal losses for three alternative sample destruction procedures are discussed; in the recommended procedure, low-temperature ashing in an oxygen plasma is followed by dissolution in sulphuric acid and aspiration into an air—acetylene flame. The necessity of close matching of the K, Na, phosphate and sulphuric acid contents for samples and standards is demonstrated for several elements. The accuracy of the method was established by using NBS SRM Bovine Liver and carefully prepared synthetic standards. The relative standard deviation is typically 5%, although variations in the blood content between portions of liver tissue lead to poorer precision for iron.  相似文献   

4.
G. Doner  A. Ege 《Analytica chimica acta》2004,520(1-2):217-222
An evaluation is made of different digestion methods for the determination of iron and zinc in biscuits prior to flame atomic absorption analysis. For the initial studies, microwave digestion was enough (using hydrogen chloride and nitric acid 3:1, v/v, at 180 °C and 600 W) to provide comparable accuracy, precision, digestion time and non-critical handling of reagents to dry-ashing and wet digestion (using different acid mixtures) and also to a simple acid treatment at room temperature. Although, after a simple microwave digestion, the spiked recoveries were found around 96–102%, to reduce the digestion time and for simplicity we worked on wet acid treatments. The results showed that acid-only treatment is not enough to digest the samples without adding ethanol, which was found necessary to digest organic residue at room temperature. The method was validated by comparison of the data found for commercial biscuit samples through using the proposed procedure and the AOAC official reference spectrophotometric method. Fe concentration in the different biscuits (such as petit beurre, baby biscuits, etc.) ranged from 1.21 to 15.96 mg/100 g while Zn concentration ranged from 0.58 to 2.50 mg/100 g depending on biscuit type. The highest concentration of Fe was in baby biscuits and these biscuits were about thirteen times richer in Fe than petit beurre biscuits.  相似文献   

5.
A method for the determination of cadmium, copper, lead, and zinc in biological tissues using small volumes of digest is described. An aluminium heating block is used to digest samples and elements are determined by spike-height flame atomic absorption spectrometry. Interferences have been assessed and the sample decomposition procedure evaluated.  相似文献   

6.
Carasek E 《Talanta》2000,51(1):173-178
A simple and fast method for the extraction into xylene of sub mug l(-1) concentrations of metals using ammonium diethyldithiophosphate (DDTP) as a complexing reagent and their subsequent determination by flame atomic absorption spectrometry is described. The method was tested in sea water spiked with Au at a concentration of 3.0 mug l(-1). The extraction was carried out until the aqueous to organic phase ratio achieved a 1000-fold preconcentration of metal. Optimisation of extraction parameters and the effect of Fe interference was investigated. Sea water samples spiked with Au produced an average recovery of 95% and the detection limit (3sigma) in deionized water was 2.9 ng l(-1). High enrichment factors could be obtained due to the small final volume (mul) of organic solvent.  相似文献   

7.
Microwave closed-system wet digestion procedures for plant samples were examined. Each procedure was tested with samples of tobacco and cabbage, and included digestion by the use of different acids composition, almost complete evaporation of the digest, and then dissolution of the residue in 1% nitric acid. Three microwave digestion programs that varied power, duration, and temperature were used. Closed-vessel reactions followed open-vessel reaction-delay time. Using flame atomic absorption spectrometry on the digests, four or five elements were determined to evaluate effectiveness, precision and accuracy of analytes extraction into solution. After a preliminary study of tobacco digests, the four most effective procedures were chosen, and detailed investigations were carried out on both tobacco and cabbage reference materials. Although all four of the final procedures were accurate, the most precise procedure, with the lowest errors of determination, was using reverse ‘aqua regia’ for tobacco and ‘aqua regia’ for cabbage.  相似文献   

8.
The interference of the organophosphorus acids, 1-hydroxyethane-1,1-bisphosphonic acid, aminotris(methylenephosphonic acid), ethylenediaminetetrakis(methylenephosphonic acid) and hexamethylenediaminetetrakis(methylenephosphonic acid) on the determination of eighteen metal ions by flame atomic absorption spectrometry is reported. Comparisons with the effect of orthophosphoric acid reveal similarities and distinct differences in their interfering effects. In the air/acetylen flame, depressive interferences are attributed to the formation of phosphates, M3(PO4)2, or hydroxynpatite-like compounds, M5(OH)(PO4)3, in the flame aerosol particles for Mg, Ca, Sr, Ba, Mn, Co and Ni. Iron(III) and chromium(III) appear to form stable oxide phosphates, M2O3?MPO4 or M3O4?MPO4. Evidence for the formation of stable molybdenum carbides, MoC and MoC2, is also presented. In the nitrous oxide/acetylene flame, serious interferences perssisted only for molybdenum but were eliminated by the addition of sodium sulphate.  相似文献   

9.
Baysal A  Akman S 《Talanta》2011,85(5):2662-2665
Sulphur in coal was determined using a high-resolution continuum source flame atomic absorption spectrophotometer (HR-CS-FAAS) with actylene/air flame. The C-S absorption band at 258.056 nm was found the most suitable analytical line with respect to sensitivity and spectral interferences. The instrumental parameters were optimized. The coal samples were dried and dissolved using microwave-assisted digestion technique. The validity of the method was tested using standard reference material and certified values were found in the limits of 95% confidence level. Since the concentrations of matrix elements of coal other than carbon are low enough not to cause any spectral interferences, the linear calibration method was applied in all quantifications without any problem. The calibration standards were prepared in sulphuric acid. The method was accurate, fast, simple and sensitive. The limit of detection (LOD, 3δ, N = 10) and the limit of quantification (LOQ, 10δ, N = 10) were found to be 0.01 and 0.03% (w/w), respectively. The sulphur concentrations of various kinds of the coal samples received around Turkey were determined. The sulphur contents of the coal samples were ranged from ≤LOQ to 1.2%.  相似文献   

10.
本文利用高碘酸钠对相邻羟基氧化作用的专属性,在一定介质中,高碘酸钠与核黄素完全反应后,过量的高碘酸的钠与硝酸铅或者硝酸铜生成沉淀,通过测定Pb<'2+>或者Cu<'2+>,建立了间接测定核黄素含量的方法.铅体系和铜体系测定的相对标准偏差(RSD)分别为4.8%和5.2%,检出限分别为0.6μg.mL<'-1>和0.5μ...  相似文献   

11.
建立了碱消解-火焰原子吸收光谱法测定土壤中六价铬的方法.讨论了pH值对六价铬测定的影响.干扰实验的结果表明同等含量的三价铬对六价铬测定无干扰.实验对比了无背景校正、氘灯背景校正、塞曼背景校正三种工作方式,分别对低、中、高三个水平土壤六价铬标准物质进行了测定,结果表明,低含量的土壤样品用塞曼背景校正方式测定的结果更准确,...  相似文献   

12.
M.C. Yebra  M.H. Bollaín 《Talanta》2010,82(2):828-36
A simple, precise and accurate automatic method for the determination of total iodine in milk products by indirect atomic absorption spectrometry is proposed. Iodide in solutions resulting from alkaline ashing of samples is precipitated with silver ion in a precipitation-dissolution flow manifold, which allows performing on-line the retention of the silver iodide precipitate formed on a filter, its wash with diluted ammonia and its dissolution with a diluted thiosulfate solution. Dissolved silver is also determined on-line by flame atomic absorption, and the achieved amount of this metal is proportional to that of iodine in the sample. The proposed method is very selective, avoids interferences from anions present in the samples, which can be also precipitated with silver, because these silver compounds are dissolved with ammonia at the washing step. This method allows the determination of iodine in the range 0.011-0.35 μg mL−1 with a relative standard deviation between 1.3 and 6.8% at a rate of ca. 17 samples h−1.  相似文献   

13.
Acid digestion procedures are described for the dissolution of human head hair in routine determinations of cadmium, chromium, mercury, lead and zinc in the same sample solution by means of atomic absorption spectrometry. The techniques employed are atomization in a Massman graphite furnace or in an air—acetylene flame; the cold-vapor cell is used for mercury. The entire analytical procedure is tested with powdered homogenized head hair samples, previously analyzed by other analytical techniques. Comparison of the results demonstrates that the proposed technique is at least as precise and accurate as the other procedures used.  相似文献   

14.
火焰原子吸收光谱法测定茯苓中微量元素   总被引:3,自引:1,他引:3  
本文确定了各微量元素火焰原子吸收光谱仪的工作条件,建立了各微量元素线性回归方程.应用火焰原子吸收光谱法测定了天然茯苓和液体发酵茯苓中微量元素含量.研究结果表明二者微量元素含量存在一定的差异,探讨了产生上述差异的原因.  相似文献   

15.
鸡尾木(ExcoecariaVenenataS.LeeetF.N.Wei)属大戟科,海漆属,为民间药用珍贵植物,用于治疗牛皮癣、慢性湿疹等,疗效颇佳[1]。鸡尾木中无机元素,尤其是医学微量元素的测定对其药理效的研究有重要的参考价值。1 实验部分1 1 仪器及试剂TAS 986原子吸收分光光度计(北京普析通用仪器有限责任公司);空心阴极灯:Fe、Cu、Ni、Cr、Cd、Zn、Co、Ba、Ca(北京瑞利普光电器厂);Mg、Pb(北京真空电子技术总公司);Mn(北京市朝阳天宫电器厂);AdventurerTM电子天平(奥豪斯国际贸易〈上海〉有限公司)。标准储备液:配制Zn2+、Mg2+、Fe3+、Mn2…  相似文献   

16.
火焰原子吸收光谱法测定软儿梨中微量元素   总被引:2,自引:0,他引:2  
采用火焰原子吸收光谱法测定了软儿梨果肉和果汁中K、Mg、Fe、Ca、Mn、Cu、Zn的含量.样品以HNO3-HClO4消解,对消解和仪器测定条件进行了优化选择,建立了相应的原子吸收光谱测定方法.方法的RSD在1.0%~3.0%之间,加标回收率在90%~100%之间.  相似文献   

17.
Some selection criteria and experimental considerations for selecting an internal standard in flame atomic absorption spectrometry were studied. Rational criteria for the selection of internal standards include the atomization efficiencies of the elements. An experimental study of the variation of the atomization degree due to a temperature decrease can be made with the help of plots of absorbance against the rate at which the sample solution is introduced. The temperature decrease produced by increasing the rate at which water was introduced using a heated chamber without water-cooled condenser was estimated to vary from 2420 K to 2218 K with 1.0 ml water per minute. Curves for the alkali, alkaline earth, and several other metals were obtained in the air-acetylene flame. The shapes of the curves are critically dependent on the degree of atomization of the metal itself. Elements with curves that have similar slopes can be used as mutual internal standards. Some of the other factors which affect the atomization efficiencies—i.e. changes in fuel and air flow, and matrix composition—were also studied.  相似文献   

18.
An acidic homogenate method, which includes simple homogenization pre-treatment of tissue material and direct nebulization flame atomic absorption spectrometry (FAAS), is successfully applied to the simultaneous determination of copper, manganese and zinc in rat liver. The proposed method involves only a few steps for sample pre-treatment at room temperature, making the risk of systematic errors very small. Because recoveries of 101% for copper, 98% for manganese and 100% for zinc could be achieved using aqueous standards, matrix-matched standards were redundant. Favourable results obtained in biological media, including limits of detection of 0.04, 0.03 and 0.04 mg l-1 for Cu, Mn and Zn, respectively, together with accuracies of 0-3%, and relative standard deviations ranging from 2 to 10% are further evidence of the suitability of the method.  相似文献   

19.
微波消解-GFAAS测定浅水湖泊底泥中重金属元素   总被引:1,自引:0,他引:1  
探讨了采用微波消解作为底泥样品的前处理方法,运用石墨炉原子吸收法测定浅水湖泊底泥中Cu,Pb,Zn,Cd,Cr含量的实验条件.方法的RSD为2.0%~4.1%,平均回收率为97.4%~101.5%,Cu,Pb,Zn,Cd,Cr的检出限分别为0.4,5,2.8,0.25,2.5ng.该法适合于浅水湖泊底泥中重金属含量的测定.  相似文献   

20.
An evolved-gas separation/flame Zeeman atomic absorption spectrometric approach is demonstrated for the speciation and determination of arsenic in oyster tissue. No digestion is needed and separation of inorganic arsenic compounds having similar boiling points is achieved. A stoichiometric or air-rich acetylene/air flame for atomic absorption spectrometry is not generally suitable for arsenic determination because of severe ultraviolet absorption interference at 193.7 nm and low sensitivity; polarized flame Zeeman atomic absorption spectrophotometry with a fuel-rich flame is suitable for the detection of traces of arsenic. The evolved-gas separation/Zeeman atomic absorption approach is simple, based on commercially available instrumentation, and useful for the selective determination of major arsenic compounds. Data are given to demonstrate optimal conditions and to show application to oyster tissue.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号