首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Silica gel surface was chemically functionalized by reaction the silanol from the silica surface with 3-chloropropyltrimethoxysilane followed by reaction with Sulfasalazine. This new sorbent has been used for the preconcentration of low levels of U(VI) ions from an aqueous phase. Parameters involved in extraction efficiency such as pH, weight of the sorbent, volume of sample and eluent were optimized in batch and column methods prior to determination by spectrophotometry using arsenazo(III) reagent. The results showed that U(VI) ions can be sorbed at pH range of 5.0–6.0 in a minicolumn and quantitative recovery of U(VI) (>98.0?±?1.6%) was achieved by stripping with 2.5 mL of 0.1 mol L?1 HCl. The sorption capacity of the functionalized silica gel was 1.15 mmol g?1 of U(VI). A linear calibration graph was obtained over the concentration range of 0.02–27.0 μg mL?1 with a limit of detection of 1 μg L?1 in treatment with 1000 mL of the U(VI) solution in which the preconcentration factor was as high as 400. The method was employed to the preconcentration of U(VI) ions from spiked ground water and synthetic sea water samples.  相似文献   

2.
A solid phase extraction method for simultaneous preconcentration and separation of trace amounts of copper, cobalt and silver in different samples, using a column packed with modified Amberlyst®15 resin is developed. Amberlyst®15 resin was modified with 5-(4-dimethylaminobenzylidene)rhodanine and then the modified resin was used as a support material for the solid phase extraction and preconcentration of Cu(II), Co(II) and Ag(I) ions from aqueous solution in the pH range 3.5–4.5. The adsorbed metal ions on the column were quantitatively eluted with a 7% thiourea solution prepared in 2?mol?L?1 HNO3, which were detected by flame atomic absorption spectrometry. The effects of analytical parameters including pH of the solution, eluent type, flow rate of samples, eluent and matrix ions were investigated for optimization of the presented procedure. The detection limits were 2.1, 0.9 and 0.9?ng?mL?1 for Cu(II), Co(II) and Ag(I) ions, respectively based on the three times the standard deviations of the blanks. The preconcentration factor was 112.5. The calibration graphs were obtained in the ranges of 0.05 to 10.0, 0.03 to 13.0 and 0.04 to 9.0?µg?mL?1 for Cu(II), Co(II) and Ag(I) ions concentrations, respectively. Relative standard deviations (n?=?7) for Cu(II), Co(II) and Ag(I) ions were found ±2.5 %, ±0.84% and ±3.8% respectively. The method was applied to the determination of mentioned ions in well water, waste water and lettuce sample.  相似文献   

3.
A simple and sensitive method is presented for solid phase extraction (SPE) and preconcentration of trace quantities of beryllium using octadecyl silica gel modifed with aurin tricarboxylic acid (aluminon). Beryllium is then determined by flame atomic absorption spectroscopy. Parameters affecting SPE such as pH, sample solution and eluent flow rate, type, concentration and volume of eluent, interfering ions and breakthrough volume, were investigated. Under optimal conditions, the beryllium ions were retained on the sorbent at pH 6–6.7, while 3.0 mL of 0.05 mol L?1 HNO3 is sufficient to elute the ions. The limit of detection (LOD) based on 3σ was 0.8 µg L?1 for 250 mL sample solution and 5 mL 0.05 mol L?1 HNO3 as eluent. The LOD can reach 0.1 µg L?1 for 1 L sample solution and 3 mL of 0.05 mol L?1 HNO3. The accuracy and precision (RSD %) of the method is >90% and <10%, respectively. The method was applied to the determination of beryllium in aqueous samples.  相似文献   

4.
In the present work, a simple procedure is presented for the extraction and determination of pre-concentrated trace amounts of palladium ions through solid phase extraction (SPE) and flame atomic absorption spectrophotometry. This process was performed using Nylon-66/5-(4-dimethylaminobenzylidene) rhodanine composite nanofibres. These nanofibres were produced under optimised conditions via two-axial electrospinning technique and characterised by scanning electron microscopy and Fourier-transform infrared spectroscopy. The effect of experimental parameters including solution pH, the type and volume of eluent and contact time was investigated in extraction and desorption process. Under the optimised conditions, good linearity in the range of 0.07–8 μg L?1 and low detection limit of 0.015 μg L?1 were obtained. High enrichment factor of 187.5 and good relative standard deviation of ±2.2% at 5 μg L?1 of palladium had been achieved. The sorbent capacity for palladium adsorption was obtained 27 mg palladium per gram of nanofibres. So, the SPE was successfully applied to pre-concentrate and determine Pd(II) ions with flame atomic absorption spectrophotometer in real samples.  相似文献   

5.
A modified SBA-15 mesoporous silica was developed, as an adsorbent, for the removal of Cr(VI) ions from natural-water samples. The effects of experimental parameters, including pH of solution, sample and eluent flow rate, the eluent composition, the eluent volume, and the effect of coexisting ions on the separation and determination of Cr(VI), were investigated. It was shown that Cr(VI) was selectively adsorbed from aqueous solution at pH 3, but Cr(III) could be adsorbed from solution at alkaline pH range. The retained Cr(VI) was eluted with 0.5?mol?L?1 KCl solution in 0.1?mol?L?1 Na2CO3 subsequently. Under the optimum conditions, the modified mesoporous silica (py-SBA-15) with a high pore diameter exhibited an adsorption capacity of 136?mg?g?1 and a lower limit of detection than 2.3?µg?L?1 by using diphenylcarbazide as a chromophorous reagent for the determination of Cr(VI) ions. A preconcentration factor as high as 200 was calculated for Cr(VI). The loaded py-SBA-15 can be reactivated with recovery of more than 98.5% over at least eight cycles. The relative standard deviation (RSD) for Cr(VI) ion recovery was less than 1.8%. Validation of the outlined method was performed by analysing a certified reference material (BCR 544). The proposed method was applied to determine Cr(VI) value in natural and waste water samples successfully.  相似文献   

6.
A sensitive and simple method has been established for simultaneous preconcentration of trace amounts of Pb (II) and Ni (II) ions in water samples prior to their determination by flame atomic absorption spectrometry. This method was based on the using of a micro-column filled with graphene oxide as an adsorbent. The influences of various analytical parameters such as solution pH, adsorbent amount, eluent type and volume, flow rates of sample and eluent, and matrix ions on the recoveries of the metal ions were investigated. Using the optimum conditions, the calibration graphs were linear in the range of 7–260 and 5–85 μg L?1 with detection limits (3Sb) of 2.1 and 1.4 μg L?1 for lead and nickel ions, respectively. The relative standard deviation for 10 replicate determinations of 50 μg L?1 of lead and nickel ions were 4.1% and 3.8%, respectively. The preconcentration factors were 102.5 and 95 for lead and nickel ions, respectively. The adsorption capacity of the adsorbent was also determined. The method was successfully applied to determine the trace amounts of Pb (II) and Ni (II) ions in real water samples. The validation of the method was also performed by the standard reference material.  相似文献   

7.
We report on the synthesis of Fe3O4-functionalized metal-organic framework (m-MOF) composite from Zn(II) and 2-aminoterephthalic acid by a hydrothermal reaction. The magnetic composite is iso-reticular and was characterized by FTIR, X-ray diffraction, SEM, magnetization, and TGA. The m-MOF was then applied as a sorbent for the solid-phase extraction of trace levels of copper ions with subsequent quantification by electrothermal AAS. The amount of sorbent applied, the pH of the sample solution, extraction time, eluent concentration and volume, and desorption time were optimized. Under the optimum conditions, the enrichment factor is 50, and the sorption capacity of the material is 2.4 mg g?1. The calibration plot is linear over the 0.1 to 10 μg L?1 Cu(II) concentration range, the relative standard deviation is 0.4 % at a level of 0.1 μg L?1 (for n?=?10), and the detection limit is as low as 73 ng L?1. We consider this magnetic MOF composite to be a promising and highly efficient material for the preconcentration of metal ions.
Figure
Magnetic metal-organic frameworks was synthesized and used as a new sorbent for lead adsorption with detection by electrothermal atomic absorption spectrometry.  相似文献   

8.
In this research, nickel ferrite (NiFe2O4) magnetic nanoparticles were synthesised by a simple method and applied as sorbent for magnetic solid-phase extraction of trace amounts of Au(III) from water samples. Detection in this technique was performed by flame atomic absorption spectrometry. The effects of sample pH, amount of sorbent, extraction time, desorption solvent and its volume on the extraction process were optimised. The effects of interfering ions on the recovery of the analyte were also evaluated in model solutions. The best results were obtained at pH 6.5 with 5 mL of eluent solution (0.1 mol L?1 sodium thiosulphate) and an extraction time of 30 min. Under optimal conditions, the sorption capacity was 34.6 mg g?1. Also, enhancement factor (for 100 mL of sample solution) was found to be 19.3. The calibration graph was linear in the range of 4.4–800.0 µg L?1 gold concentration and the limit of detection was 1.32 µg L?1. The relative standard deviation of the method (for n = 8) was 1.57%. The method was successfully applied to the extraction of Au(III) from water samples.  相似文献   

9.
A new sorbent – salen impregnated silica gel – was prepared and characterised for application as a minicolumn packing for flow-injection on-line preconcentration of cadmium(II). The system was coupled with flame atomic absorption spectrometer (FI-FAAS). The optimal pH for Cd(II) sorption was in the range of 7.4–8.8 and nitric acid (1%, v/v) was efficient as eluent. Sorption was most effective within the sample flow rate up to 7?mL?min?1. Sorption capacity of the sorbent found in a batch procedure was 26.3?µmol?g?1 (2.95?mg?g?1). Enrichment factor (EF) and limit of detection (LOD) obtained for 120-second loading time were 113 and 0.26?µg?L?1, respectively. The sorbent stability in the working conditions was proved for at least 100 preconcentration cycles. The evaluated method was applied to Cd(II) determination in various water samples.  相似文献   

10.
A new sorbent was prepared by immobilization of 2,6-diaminopyridine on activated carbon and then used as a solid-phase extractant for trace Au(III), Pd(II) and Pt(IV) before their determination by ICP-AES. Effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the potentially interfering ions were investigated. The optimum pH value is 1. The maximum static adsorption capacity for the three ions is 202.7, 38.5 and 30.1?mg?g?1, respectively. The adsorbed metal ions can be completely eluted by 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. Common other ions do not interfere. The detection limits (3??) are 0.16, 0.33 and 0.29?ng?mL?1, respectively. The relative standard deviation (RSD) was lower than 3.0% (n?=?8). The new sorbent was applied to the preconcentration of the three ions in ore and rock samples with satisfactory results.
Figure
Au(III), Pd(II), Pt(IV) are absorbed at pH 1. The maximum static adsorption capacity is 202.7, 38.5 and 30.1?mg?g?1. The eluent is 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. The relative standard deviation (RSD) was lower than 3.0% (n?=?8).  相似文献   

11.
1-(2-pryidylazo)-2-naphthol (PAN) immobilized on sodium dodecyl sulfate-coated nano alumina was developed for the preconcentration and determination of metal cations Co (II) from environmental and food samples. The research results displayed that adsorbent has the highest adsorption capacity for Co (II) in this system. Desorption by elution of the adsorbent with 2.0?ml of a mixture of nitric acid and ethanol was carried out. After phase separation, the enriched analyte in the final solution is determined by flame atomic absorption spectrometry (FAAS) by using a micro sample introduction system. Analytical influencing parameters including pH value, amount of sorbent, equilibrium time, sample volume, volume and concentration of eluent were examined. The effect of common matrix ions has also been investigated and it was found that they had no influence on cobalt preconcentration. Under the optimum experimental conditions, the maximum capacity of sorbent was obtained as 20?mg?g?1. The preconcentration factor and limit of detection were found to be 250 and 0.15?µg?L?1, respectively. This method showed good precision with the relative standard deviation (RSD) of 2.4% and 2.1% in concentrations of 20 and 50?µg?L?1, respectively. The accuracy of the method was evaluated by comparison of results with those obtained by electrothermal atomic absorption spectrometry. This method was successfully applied for preconcentration and determination of Co (II) in environmental and food samples.  相似文献   

12.
We describe a novel magnetic metal-organic framework (MOF) for the preconcentration of Cd(II) and Pb(II) ions. The MOF was prepared from the Fe3O4-pyridine conjugate and the copper(II) complex of trimesic acid. The MOF was characterized by IR spectroscopy, elemental analysis, SEM and XRD. A Box-Behnken design through response surface methodology and experimental design was used to identify the optimal parameters for preconcentration. Extraction time, amount of magnetic MOF and pH value were found to be critical factors for uptake, while type, volume, concentration of eluent, and elution time are critical in the elution step. The ions were then determined by FAAS. The limits of detection are 0.2 and 1.1 μg?L?1 for Cd(II), and Pb(II) ions, respectively, relative standard deviations are <4.5% (for five replicates at 50 μg?L?1 of Cd(II) and Pb(II) ions), and the enrichment capacity of the MOF is at around 190 mg?g?1 for both ions which is higher than the conventional Fe3O4-pyridine material. The magnetic MOF was successfully applied to the rapid extraction of trace quantities of Cd(II) and Pb(II) ions in fish, sediment, and water samples.
Figure
Schematic illustration of synthesized magnetic MOF-pyridine nanocomposite  相似文献   

13.
A new solid phase extraction method for the separation and preconcentration of Pd(II) was developed. As solid phase material, a new chelating polymer, poly [N-(4-bromophenyl)-2-methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid - co-divinylbenzene] was synthesized. The parameters such as the effect of pH, eluent type, volume and concentration, flow rate of sample solution, sample volume and effect of interfering ions for the preconcentration of Pd(II) were investigated. The optimum pH was found to be 9. Eluent for quantitative elution was 10 mL of 1 mol L?1 HCl. The preconcentration factor of the method was 75. At optimum conditions, the recovery for Pd(II) was found to be 101?±?4%. The limit of detection (3σ) was 1.1?µg L?1. The method was applied to the determination of palladium in tap water and converter samples with satisfactory results.  相似文献   

14.
The efficiencies and performances of silver nanoparticle loaded activated carbon modified with 2-(4-isopropylbenzylideneamino)thiophenol (IPBATP-Ag-NP-AC) and activated carbon modified with IPBATP (IPBATP-AC), as new sorbents, were evaluated for separation and preconcentration of Cu2+, Zn2+, Co2+, Cd2+ and Pb2+ ions from real environmental samples. The retained metals content was reversibly eluted using 5?mL of CH3COOH (6.0?mol?L?1) and/or 10?mL of 4.0?mol?L?1 HNO3 for IPBATP-Ag-NP-AC and IPBATP-AC, respectively. The experimental parameters influence the recoveries of metal ions including pH, amounts of ligand and supports, condition of eluents, sample and eluent flow rates of has been investigated. The preconcentration factors were found to be 100 for Zn2+, Cd2+, Co2+, Cu2+ and 50 for Pb2+ ions using IPBATP-Ag-NP-AC, and 50 for Zn2+, Cd2+, Co2+, Cu2+ and 25 for Pb2+ ions using IPBATP-AC. The detection limit of both SPE-based sorbents was between 1.6–2.5?ng?mL?1 for IPBATP-AC and 1.3–2.5?ng?mL?1 for IPBATP-Ag-NP-AC. The proposed methods have been successfully applied for the extraction and determination of the understudy metal ions content in some real samples with extraction efficiencies higher than 90% and relative standard deviations (RSD) lower than 2.4%.  相似文献   

15.
A new solid-phase extraction sorbent was used for the preconcentration of Pb(II) and Cr(III) ions prior to their determination by flame atomic absorption spectrometry. It was prepared by immobilization of 2,4-dinitrophenylhydrazine on nano-alumina coated with sodium dodecyl sulfate. The sorbent was characterized by scanning electron microscopy, N2 adsorption and Fourier transform infrared spectrometry, and used for preconcentration and separation of Pb(II) and Cr(III) from aqueous solutions. The ions on the sorbent were eluted with a mixture of nitric acid and methanol. The effects of sample pH, flow rates of samples and eluent, type of eluent, breakthrough volume and potentially interfering ions were studied. Linearity is maintained between 1.2 and 350???g?L-1 of Pb(II), and between 2.4 and 520???g?L-1 of Cr(III) for an 800-mL sample. The detection limit (3?s, N?=?10) for Pb(II) and Cr(III) ions is 0.43 and 0.55???g?L-1, respectively, and the maximum preconcentration factor is 267. The method was successfully applied to the evaluation of these trace and toxic metals in various water, food, industrial effluent and urine samples.
Figure
Recovery percentage of Pb(II) and Cr(III) ions at different solution volumes.  相似文献   

16.
《Analytical letters》2012,45(9):1430-1441
A new column loaded with modified silica gel-chitosan is proposed as a preconcentration system for adsorption of trace cadmium (II) and copper (II). The optimization steps were performed under dynamic conditions, involving pH, sample flow rate, eluent selection, concentration, volume, and flow rate. Trace Cd(II) and Cu(II) were quantitatively adsorbed by the modified silica gel-chitosan. The metal ions adsorbed on the separation column were eluted with 0.1 M HNO3 and determined by flame atomic absorption spectrometry. Under the optimum conditions, this method allowed the determination of cadmium and copper with limits of detection (LOD) of 20 ng L?1 and 38 ng L?1, respectively. The relative standard deviation values (RSDs) for 1.0 mg L?1 of cadmium and 1.0 mg L?1 of copper were 2.62% and 2.85%, respectively.  相似文献   

17.
In the present study, multiwalled carbon nanotubes (MWCNTs) as solid phase extraction sorbent were developed for preconcentration of arsenic(V) species prior to graphite furnace atomic absorption spectrometry (GFAAS) determination. Arsenic(V) was selectively sorbed on the packed column with MWCNTs within a pH 9.5 in the presence of 2-(5-bromo-2-pyridylazo)-5-diethyl amino phenol (5-Br-PADAP). The adsorbed species was then desorbed with 1 mL of 2.0 M HNO3. Experimental parameters including pH, sample volume and flow rate, type, volume and concentration of eluent that influence the recovery of the arsenic(V) species were optimised. Under the optimised conditions, the calibration curve was linear in the range of 0.2–10.0 µg L?1 with detection limit of 0.016 µg L?1. The relative standard deviations (RSD) for seven replicate determinations at 1.0 µg L?1 level of arsenic was 6.69%. The proposed method was successfully applied to the determination of arsenic in water samples and certified reference material (NIST RSM 1643e).  相似文献   

18.
In this paper, amino-modified nanoporous silica (APS-SBA-15) was synthesized as a new solid-phase sorbent for the extraction of glycolic acid, monochloroacetic acid, and dichloroacetic acid in synthetical betaine products. Octadecyl silica cartridge was used to reduce the concentration of matrix betaine. PS-Ag+ pre-treatment cartridge was applied to remove high Cl? concentration. The obtained effluent sample was passed through of the APS-SBA-15 sorbent. The effect of pH, flow rate of sample and eluent, and type and volume of the eluent were investigated and optimized. Chloroacetate and glycolate were eluted with 0.8 mol L?1 solution of HClO4 and measured by HPLC with a UV–vis detector. At optimum effective parameters, preconcentration factor of 129 was achieved in this method. The detection limits of mono- and dichloroacetic acid and glycolic acid were 13, 3.7, and 8.6 ng L?1, respectively.  相似文献   

19.
Expanded polystyrene (EPS) foam waste (white pollutant) was utilised for the synthesis of novel chelating resin i.e. EPS-N = N-α-Benzoin oxime (EPS-N = N-Box). The synthesised resin was characterised by FT-IR spectroscopy, elemental analysis, and thermogravimetric analysis. A selective method for the preconcentration of Pb(II) ions on EPS-N = N-Box resin packed in mini-column was developed. The sorbed Pb(II) ions were eluted with 5.0 mL of 2.0 mol L?1 HCl and determined by microsample injection system coupled flame atomic absorption spectrometry (MIS-FAAS). The average recovery of Pb(II) ions was achieved 95.5% at optimum parameters such as pH 7, resin amount 400 mg, flow rates 1.0 mL min?1 (of eluent) and3.0 mL min?1 (of sample solution). The total saturation capacity of the resin, limit of detection (LOD) and limit of quantification (LOQ) of Pb(II) ions were found to be 30 mg g?1, 0.033 μg L?1 and 0.107 μg L?1, respectively with preconcentration factor of 300. The accuracy, selectivity and validation of the method was checked by analysis of sea water (BCR-403), wastewater (BCR-715) and Tibet soil (NCS DC-78302) as certified reference materials (CRMs). The proposed method was applied successfully for the trace determination of Pb(II) ions in aqueous samples.  相似文献   

20.
A silica-based inorganic sorbent was synthesized by the thermal decomposition of ammonium heptamolybdate on silica and applied for the preconcentration and simultaneous determination of Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb in river water samples using a column system with flame atomic absorption spectrometry. Attenuated total reflection-Fourier transformation infrared spectroscopy, scanning electron microscopy, and electron dispersive spectroscopy were used for sorbent characterization. The effects of pH, sample volume, eluent type, eluent concentration, eluent volume, sample flow rate, and matrix ions (Al, Bi, Ca, Mg, and Zn) on the recovery of the metals in model solutions were investigated. The adsorption capacities (µmol g?1) of SiO2-MoO3 were 88.96 (Cd), 169.69 (Co), 153.85 (Cr), 188.88 (Cu), 179.05 (Fe), 163.81 (Mn), 136.31 (Ni), and 38.61 (Pb). The detection limits of the method were 9.09, 10.82, 10.77, 49.57, 31.64, 6.40, 8.86, 19.15?µg L?1 for Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb, respectively, with a preconcentration factor of 25. The developed method was used for the determination of the target metals in real samples and the recoveries for spiked samples were found to be from 91.2% to 102.9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号