首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Florescu M  A Brett CM 《Talanta》2005,65(2):306-312
Electrochemical glucose enzyme biosensors have been prepared on carbon film electrodes made from carbon film electrical resistors. Evaluation and characterisation of these electrodes in phosphate buffer saline solution has been carried out with and without pretreatment by cycling in perchloric acid or at fixed applied potential. Both pretreatments led to a reduction in the carbon surface oxidation peak and enabled better detection of hydrogen peroxide in the pH range of 5-7. Glucose oxidase enzyme was immobilised on the carbon surface by mixing with glutaraldehyde, bovine serum albumin and with and without Nafion. The performance of these two types of electrode was similar, that containing Nafion being more physically robust. Linear ranges were up to around 1.5 mM, with detection limits 60 μM, and pretreatment of the carbon film electrode at a fixed potential of +0.9 V versus SCE for 5 min was found to be the most beneficial. Michaelis-Menten constants between 5 mM and 10 mM were found under the different experimental conditions. Coating the immobilised enzyme layer with a thin layer of Nafion was found to give similar results in the determination of glucose to mixing it but with benefits against interferences for the analysis of complex matrices, such as wine. Potentialities, for a short-term-use or disposable sensors, are indicated.  相似文献   

2.
An amperometric biosensor based on tyrosinase immobilized in silicate/Nafion composite film has been developed for the determination of phenolic compounds. The Nafion polymer in the composite was used not only to overcome the brittleness of the pure sol-gel-derived silicate film but also to increase the long-term stability of the biosensor. Tyrosinase was immobilized by a thin film of silicate/Nafion composite on a glassy carbon electrode. Phenolic compounds were determined by the direct reduction of biocatalytically-liberated quinone species at −200 mV versus Ag/AgCl (3 M NaCl). The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH and operating potential were explored for optimum analytical performance of the enzyme electrode. The biosensor can reach 95% of steady-state current in about 15 s. The sensitivities of the biosensor for catechol and phenol were 200 and 46 mA/M, respectively. A detection limit of 0.35 mM catechol was obtained with a signal-to-noise ratio of 3. The enzyme electrode retained 74% of its initial activity after 2 weeks of storage in 50 mM phosphate buffer at pH 7.  相似文献   

3.
The analytical performance of three acetylcholinesterase (AChE) screen-printed biosensors designed for the detection of pesticides are evaluated. Bioencapsulation of the enzyme in a sol-gel composite and immobilization by metal-chelate affinity were compared with the entrapment of the enzyme in a photopolymerisable polymer. A very low amount of enzyme ranging between 0.8 and 1.2 mIU was immobilized on the electrode surface in each approach. The sensors exhibited a storage stability of over 6 months when the enzyme was encapsulated in a polymer film. Pesticide concentrations in the range of 10−8 to 10−9 M paraoxon, dichlorvos and chlorpyrifos ethyl oxon could be detected according to each configuration by following an incubation time of 20 min.  相似文献   

4.
As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.  相似文献   

5.
Modification of graphite based screen printed electrodes (SPEs) by electrosynthesised polyaniline (PANI) has been applied to improve the electron exchange between cellobiose dehydrogenase (CDH, EC 1.1.99.18) from the ascomycete Myriococcum thermophilum and the surface of the SPE. The redox intermediate layer of the conducting polymer promotes the bioelectrocatalysis providing a higher current for lactose oxidation at a lower potential compared to CDH immobilised on a plain SPE. The current of the SPE|PANI|CDH electrode was more than 5 times higher as compared to that of a SPE|CDH electrode at a potential of 0 mV vs. Ag|AgCl. When comparing the response obtained through direct electron transfer with that obtained through mediated electron transfer, it was clearly observed that the improved current of the SPE|PANI|CDH electrode is due to the specific role of PANI, rather than caused by a rise of enzyme loading. The operational stability of the enzyme electrode based on PANI modified SPE was 5 times higher compared with that based on plain SPE.  相似文献   

6.
Platinum nanoparticles (Pt NPs) were deposited onto multi-walled carbon nanotubes (MWNTs) through direct chemical reduction without any other stabilizing agents. Transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry were employed to characterize the morphology of the as-prepared nanocomposite (noted as Pt NPs-MWNTs) and further identify the Pt NPs on the surface of MWNTs. The nanocomposite demonstrated the ability to electrocatalyze the oxidation of hydrogen peroxide and substantially raises the response current. A sensitivity of 591.33 μA mM−1 cm−2 was obtained at Pt NPs-MWNTs modified electrode. Thus, we immobilized glucose oxidase (GOD) as a model enzyme on the nanocomposite-based electrode with a thin layer of Nafion to fabricate a glucose biosensor, which showed sensitive and fast response to glucose. The influence of the GOD loading was investigated and the biosensor with an enzyme loading concentration of 10 mg/mL shows optimal performance for glucose detection, that is, a detection limit of 3 μM and a response time of 3 s, respectively.  相似文献   

7.
A biosensor for determination of oxalate concentration in urine has been developed by immobilisation of oxalate oxidase and peroxidase on the surface of an interdigitated gold electrode. Enzyme immobilisation was performed using BSA and glutaraldehyde. Biamperometric measurements were made in flow conditions both in aqueous oxalate solutions (tested concentration range between 50 μM and 10 mM) and in real urine samples (tested measuring range between 5 and 100 μM). Optimal working conditions were examined for flow-injection analysis, and good correlation was achieved between added oxalate quantity and the one measured by biosensor in urine matrix (R2 = 0.9983). The influence of some interferences (ascorbic acid, uric acid, paracetamol, acetylsalicylic acid) was also studied using biamperometric measurement mode.  相似文献   

8.
A newly designed molecularly imprinted polymer (MIP) was synthesized and successfully utilized as a recognition element of an amperometric sensor for 2,4-dichlorophenol (2,4-DCP) detection. The MIP with a well-defined structure could imitate the dehalogenative function of the natural enzyme chloroperoxidase for 2,4-DCP. Imprinted sensor was fabricated in situ on a glassy carbon electrode surface by drop-coating the 2,4-DCP imprinted microgel suspension and chitosan/Nafion mixture. Under optimized conditions, the sensor showed a linear response in the range of 5.0–100 μmol L−1 with a detection limit of 1.6 μmol L−1. Additionally, the imprinted sensor demonstrated higher affinity to target 2,4-DCP over competitive chlorophenolic compounds than non-imprinted sensor. It also exhibited good stability and acceptable repeatability. The proposed sensor could be used for the determination of 2,4-DCP in water samples with the recoveries of 96.2–111.8%, showing a promising potential in practical application.  相似文献   

9.
Three cholesterol biosensor configurations based on the formation of a layer of Prussian-Blue (PB) on a Pt electrode for the electrocatalytic detection of the H2O2 generated during the enzymatic reaction of cholesterol with cholesterol oxidase (ChOx) were constructed. The enzyme was entrapped within a polypyrrole (PPy) layer electropolymerized onto the PB film. The influence of the formation of self-assembled monolayers (SAMs) on the Pt surface on the adherence and stability of the PB layer and the formation of an outer layer of nafion (Nf) as a means of improving selectivity were both studied. A comparative study was made of the analytical properties of the biosensors corresponding to the three configurations named: Pt/PB/PPy-ChOx, Pt/SAM/PB/PPy-ChOx and Pt/SAM/PB/PPy-ChOx/Nf. The sensitivity (from 600 to 8500 nA mM−1 cm−2) and selectivity of the developed biosensors permitted the determination of the cholesterol content in reference and synthetic serum samples. The detection limit for the Pt/SAM/PB/PPy-ChOx/Nf biosensor was 8 μM. Formation of the SAM on the electrode surface and covering with a Nf film considerably improved the stability and lifetime of the biosensor based on the catalytic effect of the PB layer (as the PB layer was retained longer on the electrode), and the Nf layer protects the enzyme from the external flowing solutions. Lifetime is up to 25 days of use. The formation of the SAM also has an effect on the charge transfer and the formation of the PB layer.  相似文献   

10.
An effective electrochemiluminescence (ECL) sensor based on Nafion/poly(sodium 4-styrene sulfonate) (PSS) composite film-modified ITO electrode was developed. The Nafion/PSS/Ru composite film was characterized by atomic force microscopy, UV-vis absorbance spectroscopy and electrochemical experiments. The Nafion/PSS composite film could effectively immobilize tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) via ion-exchange and electrostatic interaction. The ECL behavior of Ru(bpy)32+ immobilized in Nafion/PSS composite film was investigated using tripropylamine (TPA) as an analyte. The detection limit (S/N = 3) for TPA at the Nafion/PSS/Ru composite-modified electrode was estimated to be 3.0 nM, which is 3 orders of magnitude lower than that obtained at the Nafion/Ru modified electrode. The Nafion/PSS/Ru composite film-modified indium tin oxide (ITO) electrode also exhibited good ECL stability. In addition, this kind of immobilization approach was simple, effective, and timesaving.  相似文献   

11.
The immobilisation of AChE enzyme through chemisorption on Au-modified graphite was examined with view of its prospective application in the design of membraneless electrochemical biosensors for the assay of enzyme inhibitors. The developed immobilisation protocol has been based on a two-stage procedure, comprising i) electrodeposition of gold nanostructures on spectroscopic graphite; followed by ii) chemisorption of the enzyme onto gold nanoparticles. Both the coverage of the electrode surface with Au nanostructures and the conditions for enzyme immobilisation were optimised. The proposed electrode architecture together with the specific type of enzyme immobilisation allow for a long-term retaining of the enzyme catalytic activity. The extent of inhibition of the immobilised acetylcholinesterase enzyme by the organophosphorous compound monocrotophos has been found to depend linearly on its concentration over the range from 50 to 400 nmol mL?1 with sensitivity 77.2% inhibition per 1 µmol mL?1 of monocrotophos.   相似文献   

12.
We are proposing for the first time the use of a Nafion/multi-walled carbon nanotubes dispersion deposited on glassy carbon electrodes (GCE) as a new platform for developing enzymatic biosensors based on the self-assembling of a chitosan derivative and different oxidases. The electrodes are obtained by deposition of a layer of Nafion/multi-wall carbon nanotubes dispersion on glassy carbon electrodes, followed by the adsorption of a chitosan derivative as polycation and glucose oxidase, l-aminoacid oxidase or polyphenol oxidase, as polyanions and biorecognition elements. The optimum configuration for glucose biosensors has allowed a highly sensitive (sensitivity = (0.28 ± 0.02) μA mM−1, r = 0.997), fast (4 s in reaching the maximum response), and highly selective (0% interference of ascorbic acid and uric acid at maximum physiological levels) glucose quantification at 0.700 V with detection and quantification limits of 0.035 and 0.107 mM, respectively. The repetitivity for 10 measurements was 5.5%, while the reproducibility was 8.4% for eight electrodes. The potentiality of the new platform was clearly demonstrated by using the carbon nanotubes/Nafion layer as a platform for the self-assembling of l-aminoacid oxidase and polyphenol oxidase. Therefore, the platform we are proposing here, that combines the advantages of nanostructured materials with those of the layer-by-layer self-assembling of polyelectrolytes, opens the doors to new and exciting possibilities for the development of enzymatic and affinity biosensors using different transdution modes.  相似文献   

13.
A comparison between several acetylcholinesterase (AChE) immobilization procedures on the 7,7,8,8-tetracyanoquinodimethane (TCNQ)-modified graphite working electrodes is presented. The immobilization methods employed crosslinking with glutaraldehyde in presence of BSA protein and photopolymerization with poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ). The main variations were related to the enzyme charge in each electrode and the enzyme conditioning and storage conditions after immobilization. Initially, the enzyme-substrate reaction was carried out and the following parameters were chrono-amperometrically and -coulometrically monitored: current intensities, time to stabilize the current response, and the mass transfer represented by the Coulomb charge. The screen-printed biosensors that presented best characteristics were then used to perform the inhibition assays and to verify the sensitivity against the following NMC insecticides: aldicarb, carbaryl, carbofuran, and methomyl.In general, diffusion of electrons into the sensitive layer, mass transfer, and time to stabilize the current were adequate in all cases. The Cottrell law was followed before the 1 min of enzyme-substrate reaction. Adequate reproducibility within electrochemical measurements was also observed, with relative standard deviations varying from 6.5 to 18.6%.AChE immobilization with glutaraldehyde allow to obtain robust and reproducible biosensors, but they need a much higher enzyme content (80 mUA per electrode) to achieve current values comparable to that constructed by immobilizing the AChE through photopolymerization with PVA-SbQ (0.7 to 1 mUA per electrode). The limits of detection were determined with a minimum 10% inhibition, and varied from 10−9 to 8×10−9 M (0.2 to 1.5 ppb) by employing the enzyme immobilization through photopolymerization with PVA-SbQ. In practice, this kind of immobilization procedure is much simpler and produces good results: fast response, adequate reproducibility, large pesticides working ranges, and excellent sensitivities to N-methylcarbamates (NMCs) which in general do not present enzyme inhibition power as elevated as for the organophosphate pesticides.  相似文献   

14.
A novel amperometric biosensor for the measurement of l-lactate has been developed. The device comprises a screen-printed carbon electrode containing cobalt phthalocyanine (CoPC-SPCE), coated with lactate oxidase (LOD) that is immobilized in mesoporous silica (FSM8.0) using a polymer matrix of denatured polyvinyl alcohol; a Nafion layer on the electrode surface acts as a barrier to interferents. The sampling unit attached to the SPCE requires only a small sample volume of 100 μL for each measurement. The measurement of l-lactate is based on the signal produced by hydrogen peroxide, the product of the enzymatic reaction. The behavior of the biosensor, LOD-FSM8.0/Naf/CoPC-SPCE, was examined in terms of pH, applied potential, sensitivity and operational range, selectivity, and storage stability. The sensor showed an optimum response at a pH of 7.4 and an applied potential of +450 mV. The determination range and the response time for l-lactate were 18.3 μM to 1.5 mM and approximately 90 s, respectively. In addition, the sensor exhibited high selectivity for l-lactate and was quite stable in storage, showing no noticeable change in its initial response after being stored for over 9 months. These results indicate that our method provides a simple, cost-effective, high-performance biosensor for l-lactate.  相似文献   

15.
Electrodeposition of Pt-Pb nanoparticles (PtPbNPs) to multi-walled carbon nanotubes (MWCNTs) resulted in a stable PtPbNP/MWCNT nanocomposite with high electrocatalytic activity to glucose oxidation in either neutral or alkaline medium. More importantly, the nanocomposite electrode with a slight modification exhibited high sensitivity, high selectivity, and low detection limit in amperometric glucose sensing at physiological neutral pH (poised at a negative potential). At +0.30 V in neutral solution, the nanocomposite electrode exhibited linearity up to 11 mM of glucose with a sensitivity of 17.8 μA cm−2 mM−1 and a detection limit of 1.8 μM (S/N = 3). Electroactive ascorbic acid (0.1 mM), uric acid (0.1 mM) and fructose (0.3 mM) invoked only 23%, 14% and 9%, respectively, of the current response obtained for 3 mM glucose. At −0.15 V in neutral solution, the electrode responded linearly to glucose up to 5 mM with a detection limit of 0.16 mM (S/N = 3) and detection sensitivity of ∼18 μA cm−2 mM−1. At this negative potential, ascorbic acid, uric acid, and fructose were not electroactive, therefore, not interfering with glucose sensing. Modification of the nanocomposite electrode with Nafion coating followed by electrodeposition of a second layer of PtPbNPs on the Nafion coated PtPbNP/MWCNT nanocomposite produced a glucose sensor (poised at −0.15 V) with a lower detection limit (7.0 μM at S/N = 3) and comparable sensitivity, selectivity and linearity compared to the PtPbNP/MWCNT nanocomposite. The Nafion coating lowered the detection limit by reducing the background noise, while the second layer of PtPbNPs restored the sensitivity to the level before Nafion coating.  相似文献   

16.
Immobilisation of a self-assembled monolayer (SAM) onto an electrode surface is often achieved by immersing it in a solution for over 24 h. A biological or biologically derived recognition component can then be linked to the SAM in fabricating a biosensor. This time consuming immobilisation step can be a drawback in biosensor development, especially when repeated preparations of the biosensor are required. In this work, an alternative immobilisation strategy involving the direct application of a known quantity of the ethanolic solution of the alkanethiol, thioctic acid, on a gold electrode surface was studied. The solution was left to dry at room temperature for approximately 20 min. Comparable results including the relative percentage decrease in double layer capacitance, the surface coverage and the percentage of binding to the bacterial protein, Protein A, were obtained relative to those obtained with SAM formed by the immersion method. Shewhart’s statistical analysis technique was applied to examine the stability in terms of the relative percentage decrease in double layer capacitance. In these tests, within 99.7% confidence control limits, only a 1% deterioration was observed over a 3-month period. Therefore, all these results have demonstrated that the direct application method yields a stable thioctic acid SAM on a gold electrode surface with characteristics similar to those obtained with an immersion method. However, formation of a SAM using direct application can be achieved within a significantly shorter period of time compared to immersion method.  相似文献   

17.
A new methyl viologen-mediated amperometric enzyme electrode sensitive to glucose has been developed using carbon film electrode substrates. Carbon film electrodes from resistors fabricated by pyrolytic deposition of carbon were modified by immobilization of glucose oxidase through cross-linking with glutaraldehyde in the presence of bovine serum albumin. The mediator, methyl viologen, was directly immobilised with the enzyme together with Nafion cation-exchange polymer. The electrochemistry of the glucose oxidase/methyl viologen modified electrode was investigated by cyclic voltammetry and by electrochemical impedance spectroscopy. The biosensor response to glucose was evaluated amperometrically; the detection limit was 20 μM, the linear range extended to 1.2 mM and the reproducibility of around 3%. When stored in phosphate buffer at 4 °C and used every day, the sensor showed good stability over more several weeks.  相似文献   

18.
Wong FC  Ahmad M  Heng LY  Peng LB 《Talanta》2006,69(4):888-893
An optical biosensor consisting of a chromoionophore (ETH5294) (CM) doped sol-gel film interfaced with another sol-gel film immobilized with acetylcholinesterase (AChE) was employed to detect the insecticide dichlorvos. The main advantage of this optical biosensor is the use of a sol-gel layer with immobilized CM that possesses lipophilic property. The highly lipophilic nature of the CM and its compatibility with the sol-gel matrix has prevented leaching, which is frequently a problem in optical sensor construction based on pH indicator dyes. The immobilization of the indicator and enzyme was simple and need no chemical modification. The CM layer is pH sensitive and detects the pH changes of the acetylcholine chloride (AChCl) substrate when hydrolyzed by AChE layer deposited above. In the absence of the AChE layer, the pH response of the CM layer is linear from pH 6 to 8 (R2 = 0.98, n = 3) and it showed no leaching of the lipophilic chromoionophore. When the AChE layer is deposited on top, the optical biosensor responds to AChCl with a linear dynamic range of 40-90 mM AChCl (R2 = 0.984, n = 6). The response time of the biosensor is 12 min. Based on the optimum incubation time of 15 min, a linear calibration curve of dichlorvos against the percentage inhibition of AChE was obtained from 0.5 to 7 mg/L of dichlorvos (17-85% inhibition, R2 = 0.991, n = 9). The detection limit for dichlorvos was 0.5 mg/L. The results of the analysis of 1.7-6.0 mg/L of dichlorvos using this optical biosensor agreed well with a gas chromatography-mass spectrometry detection method.  相似文献   

19.
Two new amperometric biosensors based on immobilization of acetylcholinesterase on a sonogel-carbon electrode for detection of organophosphorous compounds are proposed. The electrodes were prepared applying high-energy ultrasounds directly to the precursors. The first biosensor was obtained by simple entrapping acetylcholinesterase in Al2O3 sol-gel matrix on the sonogel-carbon. The second biosensor was produced in a sandwich configuration. Its preparation involved adsorption of the enzyme and modification via a polymeric membrane such as polyethylene glycol and the ion-exchanger Nafion. The optimal enzyme loading was found to be 0.7 mIU. Both biosensors showed optimal activity in 0.2 M phosphate buffer, pH 7.0, at an operating potential of 210 mV. The detection limit achieved for chlorpyriphos-ethyl-oxon was 2.5 × 10−10 M at a 10-min incubation time.  相似文献   

20.
Herein, a novel label-free electrochemical aptasensor based on direct immobilization of the redox probes on an electrode surface was reported. Gold electrode coated Nafion was firstly modified with redox probe-thionine (Thi) through ion exchange adsorption. Then, with the help of chemisorption and electrostatic adsorption, negatively charged nano-Au and positively charged Thi were layer-by-layer (LBL) self-assembled onto the modified electrode surface, which formed {nano-Au/Thi+}n multilayer films for improving the amount of redox probes and immobilizing thiolated thrombin aptamers (TBA). In the presence of target thrombin (TB), the TBA on the multilayer film could catch the TB onto the electrode surface, which resulted in a barrier for electro-transfer, leading to decrease of the current. The proposed method avoided the cubsome redox probe labeling process, increased the amount of redox probe and reduced the distance between the redox probe and electrode surface. Thus, the approach showed a high sensitivity and a wider linearity to TB in the range from 0.12 nM to 46 nM with a detection limit of 40 pM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号