共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the trace analysis of methylmercury (MeHg) and Hg(II) in water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ alkylation with sodium tetraethylborate and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). The limits of quantification of MeHg and Hg(II) are 20 and 10 ng L−1 (Hg), respectively. The method shows good linearity and the correlation coefficients are higher than 0.999. The average recoveries of MeHg and Hg(II) in tap or river water sample are 102.1-104.3% (R.S.D.: 7.0-8.9%) and 105.3-106.2% (R.S.D.: 7.4-8.5%), respectively. This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of MeHg and Hg(II) in tap and river water samples. 相似文献
2.
A simple and highly sensitive method called thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 4-nonylphenol (NP) and 4-tert.-octylphenol (OP) in water samples, is described. NP and OP in samples are extracted from water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 °C) in a headspace vial. Then the extract is high sensitively analyzed by TD-GC-MS without any derivatization step. The optimum SBSE conditions are realized at an extraction time of 60 min. The detection limits are 0.02 ng ml−1 for NP and 0.002 ng ml−1 for OP. The method shows good linearity over the concentration range of 0.1-10 ng ml−1 for NP and 0.01-10 ng ml−1 for OP, and the correlation coefficients are higher than 0.999. The average recoveries of NP and OP are higher than 97% (R.S.D.: 3.6-6.2%) with correction using the added surrogate standards, 4-(1-methyl) octylphenol-d5 and deuterium 4-tert.-octylphenol. This simple, accurate, sensitive and selective analytical method may be used in the determination of trace amounts of NP and OP in tap and river water samples. 相似文献
3.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples. 相似文献
4.
This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL−1, when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement of fluoxetine in typical and trace concentration levels. 相似文献
5.
This study describes the development of a new method for determining p-hydroxybenzoic esters (parabens) in house dust. This optimised method was based on the pressurised hot water extraction (PHWE) of house dust, followed by the acetylation of the extracted parabens, stir bar sorptive extraction (SBSE) with a polydimethylsiloxane stir bar, and finally analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The combination of SBSE and PHWE allows the analytes to be preconcentrated and extracted from the aqueous extract in a single step with minimal manipulation of the sample. Furthermore the in situ acetylation of parabens prior to SBSE improved their extraction efficiency and their GC-MS signal. The method showed recoveries of between 40 and 80%, good linearity, repeatability and reproducibility (<10% RSD, at 100 ng g(-1), n=5), low limits of detection (from 1.0 ng g(-1) for propyl paraben to 2.1 ng g(-1) for methyl paraben) and quantification (from 3.3 ng g(-1) for propyl paraben to 8.5 ng g(-1) for methyl paraben). The proposed method was applied to the analysis of house dust samples. All the target parabens were found in the samples. Methyl and propyl parabens were the most abundant, with concentrations up to 2440 ng g(-1) and 910 ng g(-1), respectively. The high levels of parabens found in the samples confirm the importance of determining organic contaminants in indoor environments. 相似文献
6.
Kawaguchi M Sakui N Okanouchi N Ito R Saito K Nakazawa H 《Journal of chromatography. A》2005,1062(1):23-29
A novel method called thermal desorption (TD) with in tube silylation followed by gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of alkylphenols (APs) in river water samples, is described. APs are extracted from river water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. The stir bar coated with polydimethylsiloxane (PDMS) is added to 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 degrees C) in the vial. Then, the PDMS stir bar is subjected to TD with in tube silylation followed by GC-MS. The detection limit is of the sub pg ml(-1) (ppt) level. The method shows good linearity and the correlation coefficients are higher than 0.99 for all analytes. The average recoveries of APs are higher than 90% (R.S.D.: 3.6-14.8%, n=6). This simple and sensitive analytical method may be used in the determination of trace amounts of APs in river water samples. 相似文献
7.
大体积搅拌棒吸附萃取技术与热脱附-气相色谱-质谱法测定地表水中多环芳烃 总被引:1,自引:0,他引:1
基于搅拌棒吸附萃取(SBSE)技术建立了气相色谱-质谱测定地表水中16种多环芳烃(PAHs)的分析方法。该法采用多搅拌吸附棒同时富集,依次热脱附冷聚焦后进样的方式有效解决了搅拌棒吸附时间长、富集水样体积小等问题。优化后的结果表明,在0.2~10 ng/L范围内(萘为0.5~10 ng/L范围),16种PAHs的线性关系良好,相关系数(r)均0.99,方法检出限(MDL)为0.03~0.20 ng/L(萘为0.50 ng/L)。用该方法对钱塘江流域地表水进行测定,共检测出11种PAHs,含量为0.13~1.57 ng/L,不同添加水平下的加标回收率为75.6%~108.9%。该法可应用于地表水样品中该类物质的超痕量检测。 相似文献
8.
The identification and quantification of semi-volatile contaminants dissolved in water is currently done in laboratory after a sampling step. This procedure is not satisfactory first because risks of samples contamination and analytes losses remain, in particular when these are present in ultra-trace concentrations, and secondly because procedures are time-consuming. The coupling of the stir bar sorptive extraction (SBSE), a new device of extraction technique, and a new generation of gas chromatography mass spectrometry (GC-MS), the field apparatus EM 640 S from Bruker, could be an answer to the challenge of on-site analysis. This analytical system was used to analyze 24 PAHs, among them 15 EPA priority pollutants. It was shown that this coupling led to encouraging results with LODs around the sub-ppt level for most of the compounds and R.S.D. included between 1 and 48%. The existence of competition phenomena between the various analytes inside the absorbent phase was demonstrated with the release (up to 80%) of light compounds. This result shows the necessity to work on the kinetic domain rather than on the thermodynamic equilibrium that is influenced by nature and concentration of other compounds. The matrix effects were also studied through the comparative analysis of ultrapure water, artificial and natural seawaters spiked with PAHs and the influence of ionic strength and particulate organic matter was investigated. 相似文献
9.
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively. 相似文献
10.
This study focuses on a method for simultaneously determining personal care products in a wide range of polarities in different water matrices. The method is based on stir‐bar sorptive extraction followed by thermal desorption‐gas chromatography‐mass spectrometry. Prior to extraction, the parabens were acetylated to improve their affinity for the polydimethylsiloxane phase of the stir bar. The method showed good linearity, repeatability and reproducibility between days for all compounds and limits of detection at low ng/L levels (between 0.02 and 0.3 ng/L). The proposed method is also environmentally friendly, because it does not use organic solvents, and reduces the risk of external pollution, due to the minimal manipulation of the sample required. The method developed was successfully applied for the analysis of personal care products in different kinds of water matrices: influents and effluents of urban and industrial wastewater treatment plants, effluents of a reverse osmosis treatment plant and river waters. The influents of urban treatment plants generally showed the highest values for synthetic musks, with concentrations of up to 2219 ng/L of galaxolide, whereas the highest concentrations of parabens were detected in the industrial treatment plants influents. 相似文献
11.
The aim of this research work was the evaluation of stir-bar sorptive extraction (SBSE) in combination with an in situ derivatization to determine parabens (methylparaben, isopropylparaben, n-propylparaben, butylparaben and benzylparaben), triclosan and methyltriclosan in soil samples. This is the first time that this approach has been applied to the determination of these compounds in soil samples, providing important advantages over conventional extraction techniques, such as minimization of sampling handling, complete elimination of the use of organic solvents and simplification of the analytical procedure with reduced time consumption. The enriched target analytes were desorbed thermally using a thermodesorption system coupled to a gas chromatograph and a mass spectrometer. The optimized derivatization and SBSE extraction conditions, as well as the analytical characteristics of the method were obtained using spiked soil samples. The proposed methodology proved to be easy to use and sensitive, with limits of detection between 80 ng/kg and 1.06 μg/kg, and reproducibility values below 13%. The accuracy of the method was evaluated at two concentration levels, obtaining apparent recoveries between 91% and 110%. The matrix composition significantly influenced the extraction procedure, and a need to adopt a standard additions protocol is apparent. The analytes assayed were determined successfully in different environmental soil samples. 相似文献
12.
Natalia Campillo Pilar ViñasNerea Aguinaga Gema FérezManuel Hernández-Córdoba 《Journal of chromatography. A》2010,1217(27):4529-4534
A stir bar microextraction (SBSE) procedure for the determination of seven strobilurin fungicides in fruit samples using liquid chromatography (LC) and diode array detection (DAD) has been developed. The samples were sonicated in the presence of ethanol before submitting the extracts to SBSE. The incorporation of drazoxolon as an internal standard before SBSE allowed calibration without the need to use the standard additions method. Under the optimized conditions, detection limits were in the 0.3–2 ng g−1 range, corresponding to trifloxystrobin and metominostrobin, respectively. The SBSE–LC–DAD procedure showed good repeatability (RSD below 11% in all cases) and provided recoveries of 80–105% from spiked samples. The method was applied to fifteen fruit samples, and low levels of pyraclostrobin and trifloxystrobin were found in two of them. 相似文献
13.
Stir bar sorptive extraction for the analysis of wine cork taint 总被引:1,自引:0,他引:1
Zalacain A Alonso GL Lorenzo C Iñiguez M Salinas MR 《Journal of chromatography. A》2004,1033(1):173-178
A magnetic stir bar with a polydimethylsiloxane coating was used to absorb 2,4,6-trichloroanisole, 2,3,4,5-tetrachloroanisole, pentachloroanisole and their respective phenols from synthetic and real wine samples. The stir bar sorptive extraction method was optimised to obtain the best extraction conditions in terms of temperature, time, pH and NaCl addition. The stir bar was desorbed in a thermal desorption system coupled to a gas chromatograph-mass spectrometer. The method proposed showed good linearity over the concentration range tested and correlation coefficients ranged from 0.96 to 0.99 for all the analytes. The reproducibility and repeatability of the method was estimated between 1.29 and 4.02%. With no a pre-concentration step and with a much reduced analysis time, all the analyzed compounds showed detection and quantification limits that were lower than those observed with other methods found in the bibliography. Except for pentachlorophenol due to its poor absorptivity in polydimethysiloxane, in red wines, LOD ranged between 7.56 and 61.56 pg/l, and LOQ ranged between 17.21 and 205.11 pg/l; while in white wines, the LOD ranged between 5.82 and 30.50 pg/l and LOQ ranged between 19.41 and 101.61 pg/l. These concentrations were always lower than their respective olfactory thresholds values. 相似文献
14.
Due to the great importance of some primary aroma compounds on wine quality, these compounds which includes terpenes, C13-norisoprenoids and C6 compounds, have been analyzed by stir bar sorptive extraction (SBSE) followed by a thermal desorption-gas chromatography-mass spectrometry analysis. The stir bar sorptive extraction method was optimized in terms of temperature, time, pH and NaCl addition. The best SBSE sorption kinetics for the target analytes were obtained after submitting the solutions to 60 °C during 90 min. The addition of sodium chloride did not enhance the volatile extraction. The method proposed showed good linearity over the concentration range tested, with correlation coefficients higher than 0.98 for all the analytes. The reproducibility and repeatability of the method was estimated between 0.22 and 9.11%. The detection and quantification limits of all analytes were lower than their respective olfactory threshold values. The application of this SBSE method revealed that monovarietal white wines were clearly separated by two canonic discriminating functions when grape varieties were used as differentiating variable, the first of which explained 98.4% of the variance. The compounds which contributed most to the differentiation were limonene, linalool, nerolidol and 1-hexanol. 相似文献
15.
Julio Llorca-Pórcel Marta Martínez-ParreñoEsther Martínez-Soriano Ignacio Valor 《Journal of chromatography. A》2009,1216(32):5955-5961
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction for the analysis of phenolic organic pollutants including chlorophenols, bisphenol-A, 4-tert-octylphenol and 4-nonylphenol in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, extraction time, and the partitioning from the solvent/water mix to poly(dimethylsiloxane) (PDMS) were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of stir bar sorptive extraction with in situ derivatisation. The stir bars were analyzed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials and by comparing the analysis of real samples with the proposed method and a classical method using pressurized solvent extraction (PSE)–GC–MS. The main advantage of this method is a substantial solvent reduction. For the extraction of only 1 g of solid sample allowing limits of detection ranging from 0.2 to 1.7 μg kg−1 dw. Repeatability and reproducibility variation were lower than 20% for all investigated compounds. Results of the certified reference materials and the real samples verify the high accuracy of this method. 相似文献
16.
Ochiai N Ieda T Sasamoto K Takazawa Y Hashimoto S Fushimi A Tanabe K 《Journal of chromatography. A》2011,1218(39):6851-6860
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC. 相似文献
17.
Development and application of a polar coating for stir bar sorptive extraction of emerging pollutants from environmental water samples 总被引:1,自引:0,他引:1
In the present study, a stir bar coated with hydrophilic polymer based on poly(N-vinylpyrrolidone-co-divinylbenzene) was prepared for the sorptive extraction of polar compounds. The main parameters affecting the polymerisation of the coating were investigated.The new stir bar was applied successfully in stir bar sorptive extraction with liquid desorption followed by liquid chromatography–mass spectrometry in tandem with a triple quadrupole for the determination of a group of polar pharmaceuticals and personal care products (PPCPs) in environmental water matrices. Different variables affecting extraction and desorption such as agitation speed, temperature, ionic strength and extraction time were optimised. The results showed that the stir bar is able to enrich the selected analytes effectively.The developed method was applied to determine a group of PPCPs in different complex environmental samples, including river, effluent and influent waste water. 相似文献
18.
Julio Llorca‐Porcel Esther Martínez‐Soriano Ignacio Valor 《Journal of separation science》2009,32(9):1425-1429
An optimised method using stir bar sorptive extraction (SBSE) and a thermal desorption‐GC‐electron capture detector (GC‐ECD) for the determination of short‐chain chlorinated paraffins from water samples was developed. Recoveries near to 100% were obtained by using 20 mm×0.5 mm (length×film thickness) PDMS commercial stir bars from 200 mL spiked water samples and 20% methanol addition with an extraction period of 24 h. Method sensitivity, linearity and precision were evaluated for surface water and wastewater spiked samples. A LOD of 0.03 and 0.04 μg/L was calculated for surface and wastewater, respectively. The precision of the method given as an RSD was below 20% for both matrices. The developed method was applied for the analysis of two real samples from a contaminated river and a wastewater treatment plant. Results were in accordance with those obtained using a previously developed method based on solid phase microextraction (SPME). 相似文献
19.
Prieto A Zuloaga O Usobiaga A Etxebarria N Fernández LA 《Analytical and bioanalytical chemistry》2008,390(2):739-748
A method for the determination of polybrominated diphenyl ethers (PBDEs) and polybrominated biphenyls (PBBs) in water samples
is proposed. The method involving stir bar sorptive extraction (SBSE) and thermal desorption followed by gas chromatography
coupled with mass spectrometry was optimised using statistical design of experiments. In the first place, the influence of
different polydimethylsiloxane stir bars was studied. A Plackett–Burman design was chosen to estimate the influence of five
factors on the efficiency of the SBSE process: desorption time (5–10 min), desorption temperature (250–300 °C), desorption
flow (50–100 mL min−1), cryofocusing temperature (-130 to 40 °C) and vent pressure (0–12.8 psi). Afterwards, two central composite designs were
used to find the optimal process settings that were applied to the optimisation of both desorption and extraction efficiency.
In the case of the desorption parameters, long desorption times (10 min) and desorption flows lower than 70 mL min-1 yielded the best signals for the majority of compounds. However, different behaviour among the analytes was observed for
the vent pressure and we decided to fix it at an intermediate value (7 psi). In the case of extraction parameters, the sample
volume and the addition of NaCl did not have a significant effect, while the addition of methanol yielded better extraction
responses. Remarkable recovery (82–106%) and repeatability (less than 18%) were attained. Furthermore, excellent regression
coefficients (r
2 = 0.991–0.999) and low detection limits (1.1–6.0 ng L−1) were also achieved for the congeners studied. The proposed method was applied to the analyses of PBDEs and PBBs in waters
from the Basque Country, Spain. 相似文献
20.
A stir bar sorptive extraction (SBSE) method coupled with gas chromatography-mass spectrometry was optimised for the analysis of volatile components of a model wine, based on a previously optimised method used for analysis of the same components in model grape juice. The presence of ethanol in the model wine sample matrix resulted in decreased sensitivity of the method toward most of the volatile constituents. Mean percent relative recoveries and reproducibilities (%CV) were 22.8% and 7.1%, respectively, compared with 28.4% and 8.5% for model grape juice. The mean limit of detection (LoD) ratio (juice:wine) was 0.25. Similar sensitivities for the two sample matrices using this method were achieved by changing the split ratio from 20:1 (grape juice) to 5:1 (wine), giving a mean limit of detection ratio (juice:wine) of 1.0, thus allowing direct comparison of chromatograms of volatile components in the two matrices. This enabled direct comparisons of grape juices and the wines derived from them by alcoholic yeast fermentation. The influence of ethanol concentration in the range 9-15% on method sensitivity is discussed, using an overlay of the total ion chromatograms. The use of a gas saver device for the 5:1 split ratio analysis of desorbed model wine aroma compounds is discussed in terms of preventing extraneous reaction of sorbent and stationary phases with air during analysis. 相似文献