首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The quantitative aspects of a micellar electrokinetic chromatographic (MEKC) method for the determination of three preservatives (imidazolidinyl urea, methyl and propylparabens) in a pharmaceutical ointment are presented. Separation was carried out in a 31.2 cm long (21 cm to the detection window) × 50 μm i.d. fused silica capillary at an electric field of 960 V/cm and 25 °C. The electrolyte was 10 mM sodium dihydrogenophosphate containing 40 mM sodium dodecylsulfate (SDS) and adjusted to pH 6.1. Sample preparation consisted of a simple dispersion of the ointment in an internal standard solution (ethylparaben in the electrolyte). A 3.5 nl volume of the sample solution was introduced hydrodynamically into the capillary. The compounds detected at 200 nm were separated within 1.6 min. The method was validated with respect to specificity, linearity, accuracy, repeatability according to the International Conference on Harmonisation guidelines. Calibration curves were found to be linear for each compound (r2>0.999). Recovery studies performed by spiking an ointment placebo with the preservatives between 50 and 150% of their target concentration on 3 different days gave satisfactory results (mean recovery at each of the five concentrations ranging from 99.23 to 101.40%). The repeatability of sample preparation (n=6) was better than 2% for each of the preservatives.  相似文献   

2.
Ribeiro PR  Neto JA  Pezza L  Pezza HR 《Talanta》2005,67(1):240-244
A flow-injection spectrophotometric procedure is proposed for methyldopa determination in pharmaceutical preparations. The determination is based on formation of a yellow product (measured at 410 nm) after complexation of methyldopa with molybdate. Under optimal conditions, Beer's law is obeyed in a concentration range of 50-200 mg l−1 methyldopa. Typical correlation between absorbance and analyte concentration was 0.9999. Usual excipients used as additives in pharmaceuticals do not interfere with the proposed method. The analytical frequency was 210 h−1 and the relative standard deviation (R.S.D.) was ≤2% for sample solution containing 150 mg l−1 methyldopa (n = 11). The analytical results obtained in commercial formulations by applying the proposed FIA method were in good agreement with labeled values and those obtained by the Brazilian Pharmacopoeia procedure at 95% confidence level.  相似文献   

3.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

4.
Li YS  Gao XF 《Analytica chimica acta》2007,588(1):140-146
A novel method for the determination of ethanol in tequila based on the immobilized enzyme fluorescence capillary analysis (IE-EFCA) has been proposed. Alcohol dehydrogenase (ADH) was immobilized in inner surface of a capillary and an immobilized enzyme capillary bioreactor (IE-ECBR) was formed. After nicotinamide adenine dinucleotide (NAD+) as an oxidizer is mixed with alcohol sample solution, it was sucked into the IE-ECBR. The fluorescence intensity of the mixed solution in the IE-ECBR was detected at λex = 350 nm and λem = 459 nm. The experimental conditions are as follows: The reaction time is 20 min; temperature is 40 °C; the concentrations of phosphate buffer solution (pH 7.5) and NAD+ are 0.1 mol L−1 and 5 mmol L−1, respectively; immobilization concentration of ADH is 10 U L−1. The determination range of ethanol is 2.0-15.0 g L−1 (F = 10.44C + 6.6002, r > 0.9958); its detection limit is 1.11 g L−1; and relative standard deviation is 1.9%. IE-EFCA method is applicable for the determination of the samples containing alcohol in medicine, industry and environment.  相似文献   

5.
A novel approach was developed for nitrate analysis in a FIA configuration with amperometric detection (E = −0.48 V). Sensitive and reproducible current measurements were achieved by using a copper electrode activated with a controlled potential protocol. The response of the FIA amperometric method was linear over the range from 0.1 to 2.5 mmol L−1 nitrate with a detection limit of 4.2 μmol L−1 (S/N = 3). The repeatability of measurements was determined as 4.7% (n = 9) at the best conditions (flow rate: 3.0 mL min−1, sample volume: 150 μL and nitrate concentration: 0.5 mmol L−1) with a sampling rate of 60 samples h−1. The method was employed for the determination of nitrate in mineral water and soft drink samples and the results were in agreement with those obtained by using a recommended procedure. Studies towards a selective monitoring of nitrite were also performed in samples containing nitrate by carrying out measurements at a less negative potential (−0.20 V).  相似文献   

6.
Springer VH  Lista AG 《Talanta》2010,83(1):126-129
A new method to determine metsulfuron methyl (MSM) and chlorsulfuron (CS) in different water samples was developed. It consists in a solid phase extraction (SPE) procedure using multiwalled carbon nanotubes (MWCNTs) as sorbent material in combination with capillary zone electrophoretic determination. To carry out the pre-concentration step, a simple flow injection system was developed and optimized. Thus, 250 μL of aqueous solution containing methanol 50% (v/v) and acetonitrile 2% (v/v) as eluent, 10 mL of sample and a flow rate of 1.15 mL min−1 were selected. The CE variables also were optimized. A rapid determination and good resolution of two herbicides were obtained within 9 min using a simple electrophoretic buffer (50 mmol L−1 sodium tetraborate with 3% of methanol, pH = 9.0). Under the optimum conditions, the calibration curves were linear between 0.5 and 6 μg L−1 for MSM and CS with R2 = 0.995 and 0.997, respectively. The repeatability of the proposed method, expressed as relative standard deviation (RSD), varied between 4.1% and 5.4% (n = 10) and the detection limits for MSM and CS were 0.40 and 0.36 μg L−1, respectively. Good results were achieved when the proposed method was applied to spiked real water samples. The recoveries percentages of the two analytes were over the range 86-108%.  相似文献   

7.
Metallothioneins (MTs) belong to cysteine-rich proteins with unique higher structure. One of the most known MT's functions is metals detoxification and maintaining their homeostasis in a cell. Structure of MT with naturally occurred zinc(II) ions can be affected by concentration of metal ions as well as redox milieu inside a cell, however the exact explanation and biochemical effects of the structural changes are still missing. In this study we used capillary electrophoresis on chip coupled with fluorescence detection to determine structural changes of MT with increasing concentration of zinc(II) ions and under various redox conditions. To investigate the structural-dependent effects, reduced and/or oxidized apo-MT (MT without natural occurred metal ion) was prepared. Zinc binding into reduced and/or oxidized apo-MT was compared. MT was incubated with 0, 5, 15, 25, 50 and 100 μM ZnCl2 for 1 h in 37 °C. Formation of MT aggregates with increasing zinc concentration was observed by spectrophotometry, chip capillary electrophoresis, and SDS-PAGE. We found out that reduced MT forms aggregates more readily compared to oxidized MT. Using the chip capillary electrophoresis allowed us relative quantification of MT aggregation as a decrease in the area of the signal corresponding to the monomer form of MT (Mw 15 kDa, migration time 26.5 s) and its ratio to total signal (sum of all signals measured by the electrophoresis). The dependences had an exponential character with equation y = 2.4 × e−0.01x, R2 = 0.945 for 15 kDa peak area and y = 0.11 × e−0.01x, R2 = 0.938 for decrease of 15 kDa peak area ratio to the total signal. Zn–MT interaction was 30% faster during the first 15 min and 50% faster during the whole experiment for reduced MT. It can be concluded that formation of MT aggregates is dependent on redox state and Zn(II) concentration.  相似文献   

8.
Novel biosensors based on laccase from Aspergillus oryzae and the ionic liquids (ILs) 1-n-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6) and 1-n-butyl-3-methylimidazolium tetrafluoroborate (BMIBF4) were constructed for determination of rosmarinic acid by square-wave voltammetry. The laccase catalyzes the oxidation of rosmarinic acid to the corresponding o-quinone, which is electrochemically reduced back to rosmarinic acid at +0.2 V vs. Ag/AgCl. The biosensor based on BMIPF6 showed a better performance than that based on BMIBF4. The best performance was obtained with 50:20:15:15% (w/w/w/w) of the graphite powder:laccase:Nujol:BMIPF6 composition in 0.1 mol L−1 acetate buffer solution (pH 5.0). The rosmarinic acid concentration was linear in the range of 9.99 × 10−7 to 6.54 × 10−5 mol L−1 (r = 0.9996) with a detection limit of 1.88 × 10−7 mol L−1. The recovery study for rosmarinic acid in plant extract samples gave values from 96.1 to 105.0% and the concentrations determined were in agreement with those obtained using capillary electrophoresis at the 95% confidence level. The BMIPF6-biosensor demonstrated long-term stability (300 days; 920 determinations) and reproducibility, with a relative standard deviation of 0.56%.  相似文献   

9.
Chen F  Wang S  Guo W  Hu M 《Talanta》2005,66(3):755-761
High performance capillary electrophoresis (HPCE) was developed for quantitative determination of 18 phenylthiohydantoin (PTH)-amino acids. The influence of electrolyte concentration, pH, organic modifier and applied voltage on HPCE performance was investigated. The HPCE separation of a PTH-amino acids mixture was much improved by adding organic modifier and Tris-boric acid buffer to the run buffer. After optimization of the method, 17 PTH-amino acids in a solution containing 18 PTH-amino acids could be separated using 400 mmol l−1 Tris-boric acid, 1.0 mmol l−1 diethylamine at pH 9.5 adjusted with 0.1 mol l−1 NaOH as a run buffer, voltage of 25 kV was applied, temperature was maintained at 25 °C, detection wavelength was 254 nm. The precision (n = 7) of this method is less than 3.2% (peak area) and 1.1% (migration time) of relative standard deviation (R.S.D.). Linearity was established over the concentration range 50-1000 μM of each derivative, with correlation coefficients (r) ranging between 0.9904 and 0.9993. The detection limits (S/N = 3) range from 2 to 48 μmol l−1. The method was applied to determine amino acids in Sargassum fusiforme, a marine algae collected from Tongtou County of Zhejiang Province in China with satisfactory results.  相似文献   

10.
An efficient sample extraction and cleanup method was developed for determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in eggs. The procedure included solvent extraction of HMX from eggs followed by cleanup using florisil and styrene-divinylbenzene (SDB) cartridges. Homogenized egg aliquots were thoroughly mixed with 10 mL acetonitrile and extracted with ultrasonication for 1 h. Each sample was centrifuged and all liquid was collected for cleanup. After concentration by N2 evaporation, each extract was cleaned by florisil and SDB cartridges to remove endogenous interfering compounds. Finally, each extract was filtered through a 0.2 μm PTFE membrane and stored for liquid chromatographic-mass spectrometric (LC-MS) analysis. Chromatographic separation was achieved on a reverse phase (RP) C18 column, with a mobile phase containing 60% methanol + 40% 1.0 mM acetic acid aqueous solution. Acetic acid was employed as mobile phase additive to form negatively charged adduct ions [M + CH3COO], and m/z = 355 was quantified by selective ion monitoring (SIM). Overall recoveries from eggs containing 10, 50, 250 and 1000 ng/g of HMX were 84.0%, 88.0%, 90.6% and 87.4%. A method detection limit (MDL) of 0.15 ng/g was achieved.  相似文献   

11.
Spermine-graft-dextran (Spe-g-Dex) copolymer was synthesized and used as a non-covalent coating for the separation of proteins and neurotransmitters by capillary electrophoresis. The coating was obtained via flushing the capillary with 1.0% Spe-g-Dex copolymer solution for 2 min. Electroosmotic flow (EOF) was strongly suppressed, ranging from −1.60 × 10−9 to 3.65 × 10−9 m2 V−1 s−1. Effect of experimental conditions, such as the copolymer concentration, the concentration and pH of the background electrolyte (BGE), on the Spe-g-Dex coating was investigated. Separation of lysozyme, cytochrome c, ribonuclease A and α-chymotrypsinogen yielded high separation efficiencies ranging from 141 000 to 303 000 plates/m and recoveries from 85.4% to 98.3% at pH 4.0 (284.0 mM sodium acetate–acetic acid buffer, I = 50 mM). Run-to-run repeatabilities and day-to-day, and capillary-to-capillary reproducibilities were all below 1.7%. In addition, Spe-g-Dex coating allowed the successful separation of five neurotransmitters, 5-hydroxytryptamine, dopamine, epinephrine, isoprenaline, dobuamine at pH 4.0 with high separation efficiencies of 290 000–449 000 plates/m.  相似文献   

12.
Greice T. Macarovscha 《Talanta》2007,71(3):1150-1154
In the present work, an on-line pre-concentration system, using SiO2/ZrO2 as solid phase adsorbent, for the determination of low concentrations of arsenic was developed.In this procedure, total inorganic arsenic present in the sample is reduced to As (III) with l-cysteine and the solution is passed into a glass column (?i = 3 mm; h = 35 mm) containing 70 mg of SiO2/ZrO2 (100-230 mesh) to retain the As (III), with the solution flowing at 3.2 mL min−1. After 2 min, the concentrated species are eluted with 3 mol L−1 HCl (3.2 mL min−1) loading a 150 μL loop while a 1.0% (m/v) sodium borohydride solution loads the other loop of a FI-HG AAS system. The elution step is carried out during 7 s and, at the same time, the SiO2/ZrO2 phase is regenerated for the next concentration cycle. The arsine generated is carried with N2 (flow rate = 90 mL min−1) to a quartz cell where the electrothermal atomization process occurs.Under these conditions, a 20-fold enrichment factor is obtained considering the increase of sensitivity in the analytical curve after the concentration step. The limits of detection and quantification were 0.05 and 0.35 μg L−1, respectively, with an injection frequency of about 28 h−1 and relative standard deviation lower than 8%. Four metallurgical reference materials were analyzed with the proposed method after their acid dissolution. The results obtained were in good agreement with certified values.  相似文献   

13.
Zhou M  Ma YJ  Ren XN  Zhou XY  Li L  Chen H 《Analytica chimica acta》2007,587(1):104-109
A Ru(bpy)32+-based electrochemiluminescence (ECL) detection coupled with capillary electrophoresis (CE) has been established for the determination of sinomenine for the first time. Optimum separation was achieved with a fused-silica capillary column (50 cm × 25 μm i.d.) and a background electrolyte of 50 mM sodium phosphate (pH 5.0) at a separation voltage of 15 kV. The content of sinomenine was detected by ECL at the detection voltage of 1.15 V (versus Ag/AgCl) with 5 mM Ru(bpy)32+ in 75 mM phosphate solution (pH 8.0) when a chemically modified platinum electrode by europium(III)-doped prussian blue analogue (Eu-PB) was used as a working electrode. Under the optimized conditions, the ECL intensity was in proportion to sinomenine concentration in the range from 0.01 to 1.0 μg mL−1 with a detection limit of 2.0 ng mL−1 (3σ). The relative standard derivations of migration time and ECL intensity were 0.93 and 1.11%, respectively. The level of sinomenine in Sinomenium acutum Rehd. et Wils was easily determined with recoveries between 98.6 and 102.7%.  相似文献   

14.
Capelo JL  Dos Reis CD  Maduro C  Mota A 《Talanta》2004,64(1):217-223
A new sample preparation procedure based on tandem (that is, different diameter probe sonicators used in the same sample treatment) focused ultrasound (TFU) for mercury separation, preconcentration and back-extraction in aqueous solution from human urine has been developed. The urine is first oxidized with KMnO4/HCl/focused ultrasound (6 mm probe). Secondly, the mercury is extracted and preconcentrated with dithizone and cyclohexane. Finally, the mercury is back-extracted and preconcentrated again with the aid of focused ultrasound (3 mm probe). The procedure allows determining mercury by electrothermal atomic absorption spectrometry with fast furnace analysis and calibration against aqueous standards. Matrix modification is provided by the chemicals used in the sample treatment. The procedure is accomplished with low sample volume (8.5 ml). Low volume and low concentration reagents are used. The sample treatment is rapid (less than 3 min per sample) and avoids the use of organic phase in the graphite furnace. The preconcentration factor used in this work was 14. The limit of detection and the limit of quantification in urine were, respectively, 0.27 and 0.9 μg l−1. The relative standard deviation of aqueous standards (n=10) was 4% for a concentration of 100 μg l−1 and 5% for a concentration of 400 μg l−1. Recoveries from spiked urine with inorganic mercury, methyl-mercury, phenyl-mercury and diphenyl-mercury ranged from 86 to 98%.  相似文献   

15.
Pan X  Tian K  Jones LE  Cobb GP 《Talanta》2006,70(2):455-459
A simple, sensitive LC-ESI-MS method was optimized for quantitative analysis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in environmental samples. Under negative ionization mode, HMX can form adduct ions with various organic acids and salts, including acetic acid, formic acid, propionic acid, ammonium nitrate, ammonium chloride, sodium nitrite, and sodium nitrate. Acetic acid was chosen as additive and the ion, [M + CH3COO] with m/z = 355 was used for selective ion monitoring (SIM) in this study. Good sensitivity was achieved with low acetic acid concentration in the mobile phase and relatively low capillary temperature. The method detection limit was 0.78 pg for HMX in standard solution. Linearity (R2 > 0.9998) was obtained at low concentrations (0.5-50 μg/L). This method has been used to determine HMX concentrations in water samples and lizard egg samples from an animal exposure study.  相似文献   

16.
Ping Tong  Lan Zhang  Yu He  Jintian Cheng 《Talanta》2010,82(4):1101-1106
In this paper, a rapid and effective method based on capillary zone electrophoresis (CZE) coupled with electrospray ionization mass spectrometry (ESI-MS) was established for the trace analysis of microcystin (MC) isomers in crude algae sample. The experimental conditions including the composition, acidity and concentration of buffer, separation voltage, injection time, and MS detection parameters were investigated in detail. A capillary separation system was as follows: a uncoated fused-silica capillary tube (50 μm i.d. × 90 cm), 40 mmol L−1 ammonium acetate solution (pH 9.86) as running buffer, 25 kV as separation voltage, 20 kV × 3 s water first and 20 kV × 20 s for sample injection. Mass analysis was performed in ESI source, with sheath gas temperature 150 °C, sheath gas pressure 10 psi, and sheath gas flow 6 L min−1. And sheath liquid was 7.5 mmol L−1 acetic acid in 50% isopropanol-water (3 μL min−1). Protonation and ammonium adduct molecular ions m/z 506.9 (MC-LR) and 532.0 (MC-YR) were used for the quantification of MCs. Under these conditions, two MCs were baseline separated within 9 min, the calibration curves were obtained in the range of 0.11-10.0 μg mL−1 and 0.16-10.5 μg mL−1 for MC-LR and MC-YR, respectively. Meanwhile, limits of detection were 0.05 and 0.08 μg mL−1 for MC-LR and MC-YR, respectively. The recoveries for the two MCs were in the range of 95.8-108%. The developed approach had been successfully applied to the analysis of MCs in crude algae samples.  相似文献   

17.
A novel and sensitive cloud point extraction procedure for the determination of trace amounts of malachite green by spectrophotometry was developed. Malachite green was extracted at pH 2.5 mediated by micelles of nonionic surfactant Triton X-100. The extracted surfactant-rich phase was diluted with ethanol and its absorbance was measured at 630 nm. The effect of different variables such as pH, Triton X-100 concentration, cloud point temperature and time and diverse ions was investigated and optimum conditions were established. The calibration graph was linear in the range of 4-500 ng mL−1 of malachite green in the initial solution with r = 0.9996 (n = 10). Detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 and the relative standard deviation (R.S.D.) for 20 and 300 ng mL−1 of malachite green was 1.48 and 1.13% (n = 8), respectively. The method was applied to the determination of malachite green in different fish farming and river water samples.  相似文献   

18.
A new micelle-mediated cloud point extraction method is described for sensitive and selective determination of trace amounts of rhodamine B by spectrophotometry. The method is based on the cloud point extraction of rhodamine B from aqueous solution using Triton X-100 in acidic media. The extracted surfactant rich phase is diluted with water and its absorbance is measured at 563 nm by a spectophotometer. The effects of different operating parameters such as concentration of surfactant and salt, temperature and pH on the cloud point extraction of rhodamine B were studied in details and a set of optimum conditions were obtained. Under optimum conditions a linear calibration graph in the range of 5-550 ng mL−1 of rhodamine B in the initial solution with r = 0.9991 (n = 15) was obtained. Detection limit based on three times the standard deviation of the blank (3Sb) was 1.3 ng mL−1 (n = 10) and the relative standard deviation (R.S.D.) for 50 and 350 ng mL−1 of rhodamine B was 2.40 and 0.87% (n = 10), respectively. The method was applied for the determination of rhodamine B in soft pastel, hand washing liquid soap, matches tip and textile dyes mixture samples.  相似文献   

19.
A quantitative method of capillary electrophoresis with sample stacking induced by moving reaction boundary (MRB) was developed for sensitive determination of oxymatrine (OMT) and matrine (MT) in rat plasma. The experimental conditions were optimized firstly. Below are the optimized experimental conditions: 20 mM sodium formate solution (HCOONa, adjusted to pH 10.70 by ammonia) as sample solution, 3 min 14 mbar sample injection, 40 mM formic buffer (HCOOH-HCOONa, pH 2.60) as stacking buffer, 7 min 14 mbar injection of stacking buffer, 100 mM HCOOH-HCOONa (pH 4.80) as separation buffer, 73 cm capillary (effective length 64 cm), 21 kV voltage, 210 nm wavelength. Under the optimized conditions, higher than 60-fold sensitivity improvement of the stacking was simply achieved as compared with capillary zone electrophoresis, and the detectable limits obtained for OMT and MT were 0.26 and 0.19 μg mL−1, respectively. Then, numerous demonstrations were carefully performed for the methodological validations of OMT and MT in rate plasma, including high specificity of method, good linearity (r = 0.9993 for OMT, r = 0.9991 for MT), fair wide linear concentration range (1.30-65.00 μg mL−1 for OMT, 0.84-42.00 μg mL−1 for MT), low limit of detection (1.03 μg mL−1 for OMT, 0.38 μg mL−1 for MT), less than 5% intra- and inter-day variance value, and higher than 96% recovery of OMT and MT in plasma. The developed method could be used for the trace analyses of OMT and MT in plasma and was finally used for the investigation on pharmacokinetic study of OMT in rat plasma.  相似文献   

20.
Yanyan Lu  Zhi Xing  Po Cao  Xinrong Zhang 《Talanta》2009,78(3):869-1801
A sandwich-type immunoassay linked with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the detection of anti-erythropoietin antibodies (anti-EPO Abs). Recombinant human erythropoietin (rhEPO) was immobilized on the solid phase to capture anti-rhEPO Abs specifically. After the immunoreactions with Au-labeled goat-anti-rabbit IgG, a diluted HNO3 (2%) was used to dissociate Au nanoparticles which was then introduced to the ICP-MS for measurements. Under the optimized conditions, the calibration graph for anti-EPO Abs was linear in the range of 35.6-500 ng mL−1 with a detection limit of 10.7 ng mL−1 (3σ, n = 9). The relative standard deviation (R.S.D.) for three replicate measurements of 30.9 ng mL−1 of anti-EPO Abs was 8.43%. The recoveries of anti-EPO Abs in sera at the spiking level of 50, 100, 150, 200 and 400 ng mL−1 were 99.2%, 101.5%, 95.0%, 94.0% and 102.9%, respectively. For the real sample analysis, 26 samples from healthy people and 53 samples from patients with rhEPO treatments were studied. One sample from patients showed significantly higher anti-EPO Abs from other samples, indicating a possibility of immune response of this patient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号