首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
A biosensor for determination of oxalate concentration in urine has been developed by immobilisation of oxalate oxidase and peroxidase on the surface of an interdigitated gold electrode. Enzyme immobilisation was performed using BSA and glutaraldehyde. Biamperometric measurements were made in flow conditions both in aqueous oxalate solutions (tested concentration range between 50 μM and 10 mM) and in real urine samples (tested measuring range between 5 and 100 μM). Optimal working conditions were examined for flow-injection analysis, and good correlation was achieved between added oxalate quantity and the one measured by biosensor in urine matrix (R2 = 0.9983). The influence of some interferences (ascorbic acid, uric acid, paracetamol, acetylsalicylic acid) was also studied using biamperometric measurement mode.  相似文献   

2.
Tyrosinase from a plant source Amorphophallus companulatus was immobilized on eggshell membrane using glutaraldehyde. Among the three different approaches used for immobilization, activation of eggshell membrane by glutaraldehyde followed by enzyme adsorption on activated support could stabilize the enzyme tyrosinase and was found to be effective. Km and Vmax values for dopamine hydrochloride calculated from Lineweaver-Burk plot were 0.67 mM and 0.08 mM min−1, respectively. Studies on effect of pH showed retention of more than 90% activity over a pH range 5.0-6.5. Membrane bound enzyme exhibited consistent activity in the temperature range 20-45 °C. Shelf life of immobilized tyrosinase system was found to be more than 6 months when stored in phosphate buffer at 4 °C. An electrochemical biosensor for dopamine was developed by mounting the tyrosinase immobilized eggshell membrane on the surface of glassy carbon electrode. Dopamine concentrations were determined by the direct reduction of biocatalytically liberated quinone species at −0.19 V versus Ag/AgCl (3 M KCl). Linearity was observed within the range of 50-250 μM with a detection limit of 25 μM.  相似文献   

3.
In this study, a novel spinach (Spinacia oleracea) tissue homogenate-based biosensor for determination of oxalate in urine was developed. The biosensor was constructed by immobilizing tissue homogenate of spinach (S. oleracea) onto a high-sensitive teflon membrane of a dissolved oxygen (DO) probe. For the stability of the biosensor, general immobilization techniques were used to secure the spinach tissue homogenate in gelatin-glutaraldehyde cross-linking matrix. In the optimization and characterization studies, the amount of spinach tissue homogenate and gelatin, optimum pH, optimum temperature and thermal stability, interference effects, linear range and repeatability were investigated. A typical calibration curve for the sensor revealed a linear range of 1×10−5-10×10−5 M oxalate. In repeatability studies, variation coefficient (CV) was calculated as 1.8%. Of the various substrates tested, only oxalate was found to be specific, with a relative activity of 100%. The method was applied to the determination of oxalate in urine. The results showed that the method was applicable to oxalate determination in urine specifically and selectively.  相似文献   

4.
The optimization of a biosensor prepared by the immobilization of oxalate oxidase (OOX) with a cross-linking agent onto a multilayer inorganic/organic modified electrode, is presented. A very thin Prussian Blue (PB) film covered by a self-doped polyaniline (SPAN) layer acts as very sensitive amperometric sensor for the H2O2 formed by the enzymatic reaction. The electrode allows the very reliable and sensitive oxalate detection in the 0.08 to 0.45 mmol l−1 concentration range. The observed sensitivity was 131.3 μA mmol−1 cm−2 at the operation potential of 0.05 V versus Ag/AgCl in a succinate buffer solution (pH=3.8). The bilayer Prussian blue/SPAN leads to a very stable, sensitive and selective system that not only minimizes the interference caused by ascorbic and uric acids but also forms a very adherent sensing film that allows repetitive successive determinations.  相似文献   

5.
Gha-Young Kim 《Talanta》2007,71(1):129-135
A poly(vinyl alcohol) film cross-linked with glutaraldehyde (PVA-GA) was introduced to the surface of a tyrosinase-based carbon paste electrode. The coated PVA-GA film was beneficial in terms of increasing the stability and reproducibility of the enzyme electrode. The electrode showed a sensitive current response to the reduction of the o-quinone, which was the oxidation product of phenol, by the tyrosinase, in the presence of oxygen. The effects of the PVA and PVA-GA coating, the pH, and the GA:PVA ratio on the current response were investigated. The sensitivity of the PVA-GA-Tyr electrode was 130.56 μA/mM (1.8 μA/μM cm2) and the linear range of phenol was 0.5-100 μM. At a higher concentration of phenol (>100 μM), the current response showed the Michaelis-Menten behavior. Using the PVA-GA-Tyr electrode, a two-electrode system was tested as a prototype sensor for portable applications.  相似文献   

6.
The determination of diuron, atrazine, desisopropylatrazine (DIA) and desethylatrazine (DEA) were investigated using conductometric tyrosinase biosensor. Tyrosinase was immobilised on the biosensor sensitive part by allowing it to mix with bovine serum albumin (BSA) and then cross-linking in saturated glutaraldehyde (GA) vapour for 30 min. The determination of pollutants in a solution was performed by comparison of the output signal (i.e percentage of the enzymatic activity) of the biosensor before and after contact with pollutants. The measurement of the enzymatic activity was performed using 4-chlorophenol, phenol and catechol substrates and response times ranging from 1 to 5 min were observed. A 4-chlorophenol substrate was used to detect pesticides. A 30 min contact time of the biosensor in the pollutant solution was used. Under the experimental conditions employed, detection limits for diuron and atrazine were about 1 ppb and dynamic range of 2.3-2330 and 2.15-2150 ppb were obtained for diuron and atrazine, respectively. A relative standard deviation (n=3) of the output signal was estimated to be 5% and a slight drift of 1.5 μS h−1 was observed. The 90% of the enzyme activity was still maintained after 23 days of storage in a buffer solution at 4 °C.  相似文献   

7.
A highly sensitive amperometric nanobiosensor has been developed by integration of glucose oxidase (GOx) with a gold nanowires array (AuNWA) by cross-linking with a mixture of glutaraldehyde (GLA) and bovine serum albumin (BSA). An initial investigation of the morphology of the synthesized AuNWA by field emission scanning electron microscopy (FESEM) and field emission transmission electron microscopy (FETEM) revealed that the nanowires array was highly ordered with rough surface, and the electrochemical features of the AuNWA with/without modification were also investigated. The integrated AuNWA–BSA–GLA–GOx nanobiosensor with Nafion membrane gave a very high sensitivity of 298.2 μA cm−2 mM−1 for amperometric detection of glucose, while also achieving a low detection limit of 0.1 μM, and a wide linear range of 5–6000 μM. Furthermore, the nanobiosensor exhibited excellent anti-interference ability towards uric acid (UA) and ascorbic acid (AA) with the aid of Nafion membrane, and the results obtained for the analysis of human blood serum indicated that the device is capable of glucose detection in real samples.  相似文献   

8.
A method has been developed for the separation and determination of a set of 11 impurities from chromium matrices using oxalate form of Amberlite IRA 93. Due to slower kinetics of formation of the anionic complex, Cr(III) passed in the effluent while impurities forming strong complexes rapidly are retained on the exchanger. The adsorption of impurities of interest is found to be uniform in pH range 2-6. The adsorbed impurities are eluted with 2 mol l−1 HNO3 and determined by inductively coupled plasma-optical emission spectrometer (ICP-OES). The percentage recoveries of Al, Bi, Cd, Co, Cu, Fe, Mn, Ni, Pb, Ga and Zn are in the range 88-101% and separation of matrix is >99.9%. The method has been applied for the analysis of two samples namely CrCl3·6H2O and Cr. The R.S.D. of the method is 5-6% at >10 μg g−1 level and ∼15% at <1 μg g−1 level. The process blank values are in the range sub-μg g−1 and detection limits are in ng g−1 range.  相似文献   

9.
The construction of amperometric enzymeless biosensors for phenolic compounds determination, using carbon paste electrode modified with copper phtalocyanine (CuPc) and histidine (His), based on the chemistry of the dopamine β-monooxygenase (DβM) enzyme that catalyzes the hydroxylation of the dopamine and its analogs is shown. The modified carbon paste was evaluated on electrodes constructed in two ways: putting the paste into a cavity of a rotating disk electrode and a platinum slide electrode fixed into a glass tube. The sensor in hydrodynamic conditions presented a linear response range between 30 and 250 μmol l−1, with a sensitivity of 4.6±0.1 nA l μmol−1 cm−2 for catechol, response time of 3 s and lifetime of about 50 days when stored at room temperature. The sensor in static conditions showed a linear response range from 40 to 250 μmol l−1, with a sensitivity of 0.30±0.01 nA l μmol−1 cm−2 for catechol. The sensors presented the following relative response order for dopamine and some analog species: catechol>dopamine>guaiacol>serotonin>phenol.  相似文献   

10.
《Analytica chimica acta》2003,484(1):45-51
Alkaline-phosphatase (ALP) catalyses the hydrolysis of 1-naphthyl phosphate to fluorescent 1-naphthol (λex=346 nm, λem=463 nm). This enzymatic reaction was investigated in presence of inhibitors: organochlorine (tetradifon), carbamate (metham-sodium) and organophosphorus pesticides (fenitrothion), heavy metal (Ag+) and CN. The fluorescent signal, which is inversely dependent on the inhibitor concentration, is related to the amount of the inhibitor. Detection limits between 4.1 μM for tetradifon and 91.2 μM for metham-sodium were found. The relative standard deviation (R.S.D.) was between 2.6 and 6.2%.Sol-gel matrices derived from tetramethyl orthosilicate were doped with ALP using microencapsulation. The response of the biosensor based ALP sol-gel encapsulated to 1-naphthyl phosphate was reproducible (R.S.D.=6.6%). Inhibition plots obtained for test pesticides (metham-sodium and tetradifon) display linear calibration in the ranges 194-774 μM and 3.5-28 μM, detection limits of 4.9 and 292.3 μM and R.S.D. of 3.9 and 7.3% for metham-sodium and tetradifon, respectively. The results show that the system is able to detect class compounds such as pesticides and inorganic compounds.  相似文献   

11.
There is an increasing need to develop biosensors for the detection of harmful pesticide residues in food and water. Here, we report on a versatile strategy to synthesize functionalized graphene oxide nanomaterials with abundant affinity groups that can capture histidine (His)-tagged acetylcholinesterase (AChE) for the fabrication of paraoxon biosensors. Initially, exfoliated graphene oxide (GO) was functionalized by a diazonium reaction to introduce abundant carboxyl groups. Then, Nα,Nα-bis(carboxymethyl)-l-lysine hydrate (NTA-NH2) and Ni2+ were anchored onto the GO based materials step by step. AChE was immobilized on the functionalized graphene oxide (FGO) through the specific binding between Ni-NTA and His-tag. A low anodic oxidation potential was observed due to an enhanced electrocatalytic activity and a large surface area brought about by the use of FGO. Furthermore, a sensitivity of 2.23 μA mM−1 to the acetylthiocholine chloride (ATChCl) substrate was found for our composite covered electrodes. The electrodes also showed a wide linear response range from 10 μM to 1 mM (R2 = 0.996), with an estimated detection limit of 3 μM based on an S/N = 3. The stable chelation between Ni-NTA and His-tagged AChE endowed our electrodes with great short-term and long-term stability. In addition, a linear correlation was found between paraoxon concentration and the inhibition response of the electrodes to paraoxon, with a detection limit of 6.5 × 10−10 M. This versatile strategy provides a platform to fabricate graphene oxide based nanomaterials for biosensor applications.  相似文献   

12.
Two biosensors based on Trametes versicolor laccase (TvL) were developed for the determination of phenolic compounds. Commercial oxygen electrode and ferrocene-modified screen-printed graphite electrodes were used for preparation of laccase biosensors. The systems were calibrated for three phenolic acids. Linearity was obtained in the concentration range 0.1-1.0 μM caffeic acid, 0.05-0.2 μM ferulic acid, 2.0-14.0 μM syringic acid for laccase immobilised on a commercial oxygen electrode and 2.0-30.0 μM caffeic acid, 2.0-10.0 μM ferulic acid, 4.0-30.0 μM syringic acid for laccase immobilised on ferrocene-modified screen-printed electrodes. Furthermore, optimal pH, temperature and thermal stability studies were performed with the commercial oxygen electrode. Both electrodes were used for determination of a class of phenolic acids, achieving a cheap and fast tool and an easy to be used procedure for screening real samples of human plasma.  相似文献   

13.
An enzyme sensor for the electrochemical detection of the marine toxin okadaic acid (OA) has been developed. The strategy was based on the inhibition of immobilised protein phosphatase (PP2A) by this toxin and the electrochemical measurement of the enzyme activity by the use of appropriate enzyme substrates, electrochemically active after dephosphorylation by the enzyme. Colorimetric inhibition assays have demonstrated the PP2A from human red blood cells to be more sensitive and to provide a wider linear range than the one produced by genetic engineering. Catechyl monophosphate (CMP) and p-aminophenyl phosphate (p-APP) have been tested as enzyme substrates, the former providing higher electrochemical currents at convenient working potentials (+450 mV vs. Ag/AgCl). Biosensors with 19.1 and 5.0 U of immobilised enzyme have been applied to the OA detection. Whereas the 19.1-U biosensor has provided higher electrochemical currents and more reliable determinations, the 5.0-U one has attained a lower 50% inhibition coefficient (IC50) value (22.19 in front of 154.84 μg L−1) and a larger working range (2.69-171.87 in front of 42.97-171.87 μg L−1). The analysis of toxicogenic dinoflagellate extracts with both biosensors and the comparison with the colorimetric assay and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) have demonstrated the applicability of the developed electrochemical devices as screening biotools for the assessment of the toxicity of a sample.  相似文献   

14.
Yang H  Zhu Y 《Talanta》2006,68(3):569-574
A wide size range of SiO2 particles were synthesized and were used as enzyme immobilization carriers to fabricate glucose biosensors. The size of the particles was in the range of 17-520 nm. These biosensors could be operated under physiological conditions (0.1 M phosphate buffer, pH 7.2). Particle size could affect the performance of SiO2 modified glucose biosensors drastically. The smaller particles had higher performance. The smallest SiO2 modified biosensor could work well in the glucose concentration range of 0.02-10 mM with a correlation coefficient of 0.9993. Its sensitivity was 2.08 μA/mM and the detection limit was 1.5 μM glucose.  相似文献   

15.
A highly sensitive, fast and stable conductometric enzyme biosensor for determination of nitrate in water is reported for the first time. The biosensor electrodes were modified by methyl viologen mediator mixed with nitrate reductase (NR) from Aspergillus niger by cross-linking with glutaraldehyde in the presence of bovine serum albumin and Nafion® cation-exchange polymer. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH, the enzyme loading and time of immobilization in glutaralaldehyde vapor were investigated with regard to their influence on sensitivity, limit of detection, dynamic range and operational and storage stability. The biosensor can reach 95% of steady-state conductance value in about 15 s. Linear calibration in the range of 0.02 and 0.25 mM with detection limits of 0.005 mM nitrate was obtained with a signal-to-noise ratio of 3. When stored in 5 mM phosphate buffer (pH 7.5) at 4 °C, the sensor showed good stability over 2 weeks.  相似文献   

16.
Fluorescence and terbium-sensitised luminescence properties of new quinolone garenoxacin have been studied. The fluorimetric method allows the determination of 0.060-0.600 μg ml−1 of garenoxacin in aqueous solution containing HCl/KCl buffer (pH 1.5) with λexc=282 nm and λem=421 nm. Micellar-enhanced fluorescence was also studied, leading to a higher than 400% increase in analytical signal in presence of 12 mM sodium dodecyl sulphate (SDS), allowing the determination of 0.020-0.750 μg ml−1 of garenoxacin. The terbium-sensitised luminescence method allows the determination of 0.100-1.500 μg ml−1 of garenoxacin in 12 mM SDS solution containing 0.08 M acetic acid/sodium acetate buffer (pH 4.1) and 7.5 mM Na2SO3 (chemical deoxygenation agent), with λexc=281 nm and λem=546 nm. Relative standard deviation (R.S.D.) values for the three methods were in the range 1.0-2.0%. The proposed procedures have been applied to the determination of garenoxacin in spiked human urine and serum.  相似文献   

17.
Qu F  Shi A  Yang M  Jiang J  Shen G  Yu R 《Analytica chimica acta》2007,605(1):28-33
Prussian blue nanowire array (PBNWA) was prepared via electrochemical deposition with polycarbonate membrane template for effective modification of glassy carbon electrode. The PBNWA electrode thus obtained was demonstrated to have high-catalytic activity for the electrochemical reduction of hydrogen peroxide in neutral media. This enabled the PBNWA electrode to show rapid response to H2O2 at a low potential of −0.1 V over a wide range of concentrations from 1 × 10−7 M to 5 × 10−2 M with a high sensitivity of 183 μA mM−1 cm−2. Such a low-working potential also substantially improved the selectivity of the PBNWA electrode against most electroactive species such as ascorbic acid and uric acid in physiological media. A detection limit of 5 × 10−8 M was obtained using the PBNWA electrode for H2O2, which compared favorably with most electroanalysis procedures for H2O2. A biosensor toward glucose was then constructed with the PBNWA electrode as the basic electrode by crosslinking glucose oxidase (GOx). The glucose biosensor allowed rapid, selective and sensitive determination of glucose at −0.1 V. The amperometric response exhibited a linear correlation to glucose concentration through an expanded range from 2 × 10−6 M to 1 × 10−2 M, and the response time and detection limit were determined to be 3 s and 1 μM, respectively.  相似文献   

18.
Stabilisation of electrochemically deposited Prussian blue (PB) films on glassy carbon (GC) electrodes has been investigated and an enhancement in the stability of the PB films is reported if the electrodes are treated with tetrabutylammonium toluene-4-sulfonate (TTS) in the electrochemical activation step following the electrodeposition. A multi-enzyme PB based biosensor for sucrose detection was made in order to demonstrate that PB films can be coupled with an oxidase system. A tri-enzyme system, comprising glucose oxidase, mutarotase and invertase, was crosslinked with glutaraldehyde and bovine albumin serum on the PB modified glassy carbon electrode. The deposited PB operated as an electrocatalyst for electrochemical reduction of hydrogen peroxide, the final product of the enzyme reaction sequence. The electrochemical response was studied using flow injection analysis for the determination of sucrose, glucose and H2O2. The optimal concentrations of the immobilisation mixture was standardised as 8 U of glucose oxidase, 8 U of mutarotase, 16 U of invertase, 0.5% glutaraldehyde (0.025 μl) and 0.5% BSA (0.025 mg) in a final volume of 5 μl applied at the electrode surface (0.066 cm2). The biosensor exhibited a linear response for sucrose (4-800 μM), glucose (2-800 μM) and H2O2 (1-800 μM) and the detection limit was 4.5, 1.5 and 0.5 μM for sucrose, glucose and H2O2, respectively. The sample throughput was ca. 60 samples h−1. An increase in the operational and storage stability of the sucrose biosensor was also noted when the PB modified electrodes were conditioned in phosphate buffer containing 0.05 M TTS during the preparation of the PB films.  相似文献   

19.
Developing a biosensor which is capable of simultaneously monitoring l-Dopa levels in multiple samples besides requiring small reaction volume is of great value. The present study describes the detection of l-Dopa using tyrosinase enzyme extracted from Amorphophallus campanulatus and immobilized on the surface of the microplate wells. Among the different approaches used for immobilizing tyrosinase onto the microplate wells, glutaraldehyde treatment was found to be most effective. Besides enzyme activity, ESEM–EDS (environmental scanning electron microscope–energy dispersive system) and Atomic Force Microscopy (AFM) were also carried out to confirm the immobilization of tyrosinase enzyme onto the microplate well surface. This immobilized biocomponent was then integrated with an optical transducer for l-Dopa detection and it showed good reproducibility. The sensing property of the system was studied by measuring the initial rate of dopachrome formation at 475 nm. The calibration plot gave a linear range of detection from 10–1000 μM and the detection limit was calculated to be 3 μM. The immobilized biocomponent was stable for 41 days and was reused up to nine times. Spiked samples (blood plasma) were also analyzed using this biocomponent. This microplate based biosensor thus provides a convenient system for detection of multiple samples in a single run.  相似文献   

20.
Imipenem shows a fast chemical conversion to a more stable imin form (identical to that of biochemical dehydropeptidase degradation) in aqueous solutions and stabilizing agents used avoid its electrochemical study and determination.The aim of this work is the proposal of urea as stabilizing agent which allows the electrochemical study of imipenem and the proposal of electrochemical methods for the determination of imipenem and its primary metabolite (M1) in human urine samples. Electrochemical studies were realized in phosphate buffer solutions over pH range 1.5-8.0 using differential-pulse polarography, DC-tast polarography, cyclic voltammetry and adsorptive stripping voltammetry. In acidic media, a non-reversible diffusion-controlled reduction involving a two steps mechanism which involves one electron and one proton in the first step and two electrons and two protons in the second step occurs and the mechanism for the reduction was suggested.A differential-pulse polarographic method for the determination of imipenem in the concentration range 3.2 × 10−6 to 2 × 10−5 M (0.95-3.4 mg/L) and its primary metabolite in the concentration range 1.4 × 10−6 to 10−4 M (0.43-26.1 mg/L) with detection limits of 9.6 × 10−7 M (0.28 μg/L imipenem) and 4.3 × 10−7 M (0.14 μg/L M1) was proposed. Also, a method based on controlled adsorptive pre-concentration of imipenem on the hanging mercury drop electrode followed by voltammetric measure, allows imipenem determination in the concentration range 1.8 × 10−8 to 1.2 × 10−6 M (5.42-347 μg/L) with a detection limit of 5.4 × 10−9 M (1.63 μg/L). The proposed methods have been used for the direct determination of the analytes in a pharmaceutical formulation and human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号