首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Lirong Luo  Lingyan Hou  Jinli Wang  Wei Tian 《Talanta》2007,72(4):1293-1297
The paper presented a novel chemiluminescence (CL) immunoassay method, which combines the advantages of traditional enzyme-linked immunosorbent assays (ELISA) and bis (2,4,6-trichlorophenyl) oxalate (TCPO)-hydrogen peroxide CL detection system. A fluorescent product 2,3-diaminophenazine (DAPN) was produced by reaction between o-phenylenediamine (OPDA, 1,2-diaminobenzene) and H2O2 catalyzed by horseradish peroxidase (HRP). DAPN was excited by the reactive intermediate of TCPO-H2O2 chemiluminescent reaction, and led to CL. The dependence of the CL intensity on the concentrations of antigen was studied. As analytical application, the proposed method was used for determination of recombinant human interleukin 6 (rHu IL-6) and β-human chorionic gonadotropin (β-HCG). Under the selected experimental conditions, a linear relationship was obtained between the CL intensity and the concentration of rHu IL-6 in the range of 4.0-625.0 pg/ml, and β-HCG in the range of 12.5-400.0 mIU/ml. The detection limits were 0.5 pg/ml for rHu IL-6 and 3 mIU/ml for β-HCG with relative standard deviation of 2.3 for 78.0 pg/ml rHu IL-6, and 3.9 for 50.0 mIU/ml β-HCG. This method has been applied to the determination of rHu IL-6 in human serum and β-HCG in urine with satisfactory results.  相似文献   

2.
Summary Molecular dynamics simulations have been performed on a number of conformationally flexible pyrethroid insecticides. The results indicate that molecular dynamics is a suitable tool for conformational searching of small molecules given suitable simulation parameters. The structures derived from the simulations are compared with the static conformation used in a previous study. Various physicochemical parameters have been calculated for a set of conformations selected from the simulations using multivariate analysis. The averaged values of the parameters over the selected set (and the factors derived from them) are compared with the single conformation values used in the previous study.  相似文献   

3.
Permethrin is the most popular synthetic pyrethroid insecticide used in agriculture and public health. For the assessment of human exposure to permethrin, a competitive indirect enzyme-linked immunosorbent assay (ELISA) for the detection of the glycine conjugate of a major metabolite, cis-/trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (DCCA), of permethrin was developed based on a polyclonal antibody. An assay based on an antibody with a high sensitivity was optimized and characterized. The IC50 value and the detection range for trans-DCCA–glycine, in the assay buffer were 1.2 and 0.2−7.0 μg/L, respectively. The antibody recognized trans-DCCA–glycine and the mixture of cis-/trans-DCCA–glycine with an isomer range from 30:70 to 50:50 nearly equally. Little or no cross-reactivity to permethrin and its other free metabolites or glycine conjugates was measured. The integration of the ELISA and solid-phase extraction which was used to reduce the matrix effect from human urine samples provided for analysis of total cis-/trans-DCCA–glycine at low parts per billion levels in the samples. The limit of quantitation of the target analyte was 1.0 μg/L in urine with a limit of detection of 0.1 μg/L in buffer. This assay might be a useful tool for monitoring human exposure to permethrin.  相似文献   

4.
The discovery stories of three fluorine-containing insecticides in our laboratory are described, i.e. amidoflumet, a new trifluoromethanesulfonanilide with high miticidal activity against various house dust mites, Metofluthrin, a potent new fluorinated pyrethroid with extremely high knockdown activity against various mosquitoes, and a new α-pyrone compound, 3-[1R-trans-(2-trifluoromethyl)cyclopropanecarbonyl]-4-hydroxy-6-methyl-2-pyrone with outstanding insecticidal activity against Blattella germanica.  相似文献   

5.
《Analytical letters》2012,45(4):386-394
In this study, a specific monoclonal antibody (Mab) against oxytetracycline (OTC) and its metabolite 4-epi-Oxytetracycline (4-epi-OTC) was produced. Based on this Mab, a sensitive and reliable method indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was developed for the detection of OTC and 4-epi-OTC from chicken meats. The ic-ELISA showed a 50% inhibition (IC50) value of 2.01 ± 0.16 ng/ml and a detection limit of 0.13 ± 0.03 ng/ml. The recoveries from chicken muscles and livers spiked with OTC of 50–600 ng/g were 83.33–88.25% and 84.62–86.12%, respectively. The intra-assay coefficients of variation (CVs) were 4.73–9.31%, and the inter-assay CVs were 6.44–11.01%. The method showed a positive correlation with the traditional method HPLC (R2 = 0.997) within a certain concentration of OTC used in this assay. The method developed in this study was simple and independent of specific expensive equipment. Thus, it could be useful as a convenient method to detect OTC residues.  相似文献   

6.
Development of an enzyme-linked immunosorbent assay for pentachlorophenol   总被引:5,自引:0,他引:5  
Pentachlorophenol (PCP) is a hazardous pollutant with toxicity and potential carcinogenic properties being a serious threat to the environment. In this work, the development of an immunoassay for PCP is presented. A hapten was synthesised and conjugated to protein for rabbit immunisation. Three polyclonal antibodies were obtained and the best results were achieved in the antibody-coated format using antiserum R3. Calibration range was 0.3–30.5 ng ml−1, with an average I50 value of 2.9 ng ml−1 and a detection limit of 0.1 ng ml−1. The specificity of the assay was tested against PCP structurally related compounds. The method is highly specific for PCP and shows low cross-reactivity (CR) for chlorine-containing phenols, nitrophenols, benzenic and piridinic compounds. The good recoveries achieved with different water samples indicate that this assay can be a good alternative method for the determination of PCP in this kind of samples.  相似文献   

7.
A class II valence force field covering a broad range of organic molecules has been derived employing ab initio quantum mechanical "observables." The procedure includes selecting representative molecules and molecular structures, and systematically sampling their energy surfaces as described by energies and energy first and second derivatives with respect to molecular deformations. In this article the procedure for fitting the force field parameters to these energies and energy derivatives is briefly reviewed. The application of the methodology to the derivation of a class II quantum mechanical force field (QMFF) for 32 organic functional groups is then described. A training set of 400 molecules spanning the 32 functional groups was used to parameterize the force field. The molecular families comprising the functional groups and, within each family, the torsional angles used to sample different conformers, are described. The number of stationary points (equilibria and transition states) for these molecules is given for each functional group. This set contains 1324 stationary structures, with 718 minimum energy structures and 606 transition states. The quality of the fit to the quantum data is gauged based on the deviations between the ab initio and force field energies and energy derivatives. The accuracy with which the QMFF reproduces the ab initio molecular bond lengths, bond angles, torsional angles, vibrational frequencies, and conformational energies is then given for each functional group. Consistently good accuracy is found for these computed properties for the various types of molecules. This demonstrates that the methodology is broadly applicable for the derivation of force field parameters across widely differing types of molecular structures. Copyright 2001 John Wiley & Sons, Inc. J Comput Chem 22: 1782-1800, 2001  相似文献   

8.
The development of a rapid one-step antigen-immobilized inhibition ELISA for microcystin-LR is described. For microplate coating a microcystin-biotin conjugate was synthesized. Using the commercially available monoclonal antibody MC10E7 in our newly established assay, IC50 values of 0.045 μg l−1 have been achieved. The detection limit for microcystin-LR was 4 ng l−1. Considering the guidelines proposed by the world health organization (WHO) for microcystin-LR in drinking water (1 μg l−1) the sensitivity of our test is more than sufficient. The period of assay processing could successfully be shortened to about 3 h without any loss in sensitivity. The suitability of the newly developed assay was evaluated with microcystin-LR spiked environmental water samples. Recovery rates for microcystin-LR between 60 and 165% were obtained in the linear range of the test format. The antigen-immobilized test format provides a highly reproducible, easy, and fast to perform detection system for microcystin allowing an internal retrospective quality control of the assay.  相似文献   

9.
A set of haptens has been synthesized in order to raise generic polyclonal antibodies against sulfonamides using different strategies. After the screening of all the immunorreagents, a highly sensitive enzyme-linked immunosorbent assay was set-up for simultaneous determination of six of these antibiotics.The developed procedure allows the screening of: sulfathiazole, sulfamethoxypyridazine, sulfapyridine, sulfamethizole, sulfasalazine and N4-phtalylsulfathiazole with good accuracy and precision at level 0.13 ng mL−1 in buffer.The suitability of developed ELISA for its application to honey analysis has been investigated. The antimicrobials were extracted from samples with acetate buffer, and cleaned up by solid phase extraction. The mean recovery found for honey samples, spiked from 1.5 to 4.5 ng mL−1 equivalents of sulfathiazole (24-72 μg sulfathiazole kg−1 honey), was 106%.  相似文献   

10.
A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the insect growth regulator fenoxycarb. Polyclonal rabbit antisera, raised against protein conjugates of four haptenic derivatives of fenoxycarb, were utilized in immobilized antigen-based, competitive immunoassays. With ELISA systems that were both hapten- and carrier-heterologous, most antiserum titers fell in the range of 1:1000-1:30,000. Assay conditions, including concentrations of antisera and coating antigens, were optimized. The effect of pH, organic solvents, and various blocking agents was also investigated. A hapten-homologous and two hapten-heterologous indirect ELISAs allowed fenoxycarb determination in the range of 0.1-85 ng ml−1 with apparent IC50 values of 1.2-2.8 ng ml−1. Cross-reactivities with a number of compounds (e.g. pesticides of related structure, hapten synthesis intermediates, fenoxycarb metabolite, photodegradation products) were determined, and the assay proved highly selective for fenoxycarb. In particular, no significant interference was found with selected pyrethroid and juvenile hormone analog insecticides, phenoxyacetic acid herbicides, and photodegradation products of fenoxycarb. Using spiked water samples, assay performance was validated by SPME/GC-MS.  相似文献   

11.
Yanyan Lu  Zhi Xing  Po Cao  Xinrong Zhang 《Talanta》2009,78(3):869-1801
A sandwich-type immunoassay linked with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the detection of anti-erythropoietin antibodies (anti-EPO Abs). Recombinant human erythropoietin (rhEPO) was immobilized on the solid phase to capture anti-rhEPO Abs specifically. After the immunoreactions with Au-labeled goat-anti-rabbit IgG, a diluted HNO3 (2%) was used to dissociate Au nanoparticles which was then introduced to the ICP-MS for measurements. Under the optimized conditions, the calibration graph for anti-EPO Abs was linear in the range of 35.6-500 ng mL−1 with a detection limit of 10.7 ng mL−1 (3σ, n = 9). The relative standard deviation (R.S.D.) for three replicate measurements of 30.9 ng mL−1 of anti-EPO Abs was 8.43%. The recoveries of anti-EPO Abs in sera at the spiking level of 50, 100, 150, 200 and 400 ng mL−1 were 99.2%, 101.5%, 95.0%, 94.0% and 102.9%, respectively. For the real sample analysis, 26 samples from healthy people and 53 samples from patients with rhEPO treatments were studied. One sample from patients showed significantly higher anti-EPO Abs from other samples, indicating a possibility of immune response of this patient.  相似文献   

12.
An efficient and reliable analytical method was developed for the sensitive and selective quantification of pyrethroid pesticides (PYRs) in house dust samples. The method is based on selective pressurized liquid extraction (SPLE) of the dust-bound PYRs into dichloromethane (DCM) with analysis by gas chromatography/mass spectrometry. Various adsorbents and combinations of extraction solvents and temperatures were evaluated to achieve a high-throughput sample preparation that eliminates the post-extraction cleanup step. The final method used sulfuric acid-impregnated silica (acid silica) and neutral silica together in the extraction cell with the dust sample to provide both extraction and cleanup simultaneously. The optimal ratio of dust/acid silica/silica was 1:0.8:8. The extraction was performed at 2000 psi, at 100 °C with DCM for 5 min in three cycles. Method precision and accuracy were evaluated by the analysis of triplicate aliquots of the dust samples and the samples fortified with the target PYRs. The accuracy measured as the recoveries of the PYRs in the fortified samples ranged from 85% to 120%. The precision measured as the relative standard deviation of replicate samples was within ±25%. The SPLE method was applied to 20 house dust samples collected from households that participated in two field studies regarding exposures to pesticides and other pollutants. Similar concentrations of target PYRs were obtained for the SPLE and a stepwise extraction/cleanup procedure. The SPLE procedure reduces organic solvent consumption and increases the sample throughput when compared with a traditional stepwise extraction and cleanup procedure. This study demonstrates that the SPLE procedure can be applied to complex dust matrices for analysis of PYRs for large scale exposure or environmental monitoring studies.  相似文献   

13.
In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L−1 to as low as 0.07 μg L−1. The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step.  相似文献   

14.
J.A. Gabaldón  R. Puchades 《Talanta》2007,71(3):1001-1010
The suitability of immunoassay methodology for rapid and accurate determination of chlorpyrifos in vegetables was tested. The optimised ELISA detection limit was 0.32 ng/ml, with a working range from 0.69 to 6.21 ng/ml and an immunoassay test-mid point (IC50) of 2.08 ng/ml. A rapid sample preparation procedure considering different parameters such as the amount of sample, volume of extractant, extraction time and dilution factor was optimised. The developed direct extraction (DE) and multiresidue (ME) standard procedures were performed in different fortified fresh and processed vegetable samples (tomato, bonnet pepper, bean, pea, asparagus, broccoli, watermelon, melon, lettuce, cucumber, celery and red pepper). Recoveries were in all cases in the whole range 85.2-108.9% for both DE and ME extracts. Also, the comparison of the results obtained by both immunochemical and chromatographic methods for spiked fruits and vegetables were good with a correlation coefficient (r) of 0.97.  相似文献   

15.
This report highlights the characteristics of a general method of performing non-competitive immunoassays for low-molecular-mass analytes, which was developed and applied to 1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane (DDT) determination in aqueous samples. The method is based on the separation of the analyte-bound antibody from the excess of the free antibody by a chromatographic step, followed by the dissociation of the complex and the capture of the previously bound antibody on a solid phase. The measured signal is linearly correlated to the concentration of the complex and, consequently, to the analyte concentration. The 3σ limit of detection (LOD, 8 ng l−1) obtained by the above method enabled us to decidedly improve the sensitivity of the corresponding enzyme-linked immunosorbant assay (ELISA) and of all reported immunoassays for DDT.In addition, by applying this new format, even if a very selective antibody was used, a broad selectivity was observed, which allowed DDT + DDD + DDE to be determined instead of only p,p′-DDT as in the ELISA performed with the same antibody. In addition, real water samples were validated in a percentage recovery test. Very good recovery rates were obtained, highlighting the validity of the proposed method to accurately determine the total DDT content in water.  相似文献   

16.
Proteins from the Cry 1 family, in particular Cry 1Ab, are commonly expressed in genetically modified Bt maize in order to control chewing insect pests. A sensitive chemiluminescent sandwich enzyme immunoassay for the detection of Cry1Ab protein from genetically modified Bt maize has been developed and validated. A Cry1Ab protein-specific antibody was immobilized on 96- or 384-well microtiter plates in order to capture the Cry1Ab toxin in the sample; the bound toxin was then detected by employing a second anti-Cry1Ab antibody and a horseradish peroxidase-labeled anti-antibody, followed by measurement of the enzyme activity with an enhanced chemiluminescent system. The chemiluminescent assay fulfilled all the requirements of accuracy and precision and exhibited limits of detection of a few pg mL−1 Cry1Ab (3 or 5 pg mL−1, depending on the assay format), which are significantly lower than that achievable using conventional colorimetric detection of peroxidase activity and also represent an improvement compared to previously developed Cry1Ab immunoassays. High-throughput analysis can be performed using the 384-well microtiter plate format immunoassay, which also allows one to reduce the consumption of samples and reagents. Validation of the assay, performed by analyzing certified reference materials, proved that the immunoassay is able to detect the presence of the Cry1Ab protein in certified reference samples containing as low as 0.1% of MON 810 genetically modified Bt maize. This value is below the threshold requiring mandatory labeling of foods containing genetically modified material according to the actual EU regulation.  相似文献   

17.
Polycyclic aromatic hydrocarbons (PAHs) are frequently encountered in the environment and may pose health concerns due to their carcinogenicity. A commercial enzyme-linked immunosorbent assay (ELISA), was evaluated as a screening method for monitoring PAHs at contaminated sites. The ELISA was a carcinogenic PAH (C-PAH) RaPID assay testing kit that cross-reacts with several PAHs and utilizes benzo[a]pyrene (BaP) as a calibrator. Soil samples were extracted with 50% acetone in dichloromethane (DCM) for analysis by ELISA and gas chromatography-mass spectrometry (GC-MS). The overall method precision was within ±30% for ELISA and within ±20% for GC-MS. Recovery data for spiked soils ranged from 46 to 140% for BaP as determined by ELISA. Recoveries data of the GC-MS surrogate standards, 2-fluorobiphenyl and chrysene, were greater than 70%. The GC-MS procedure detected a total of 19 priority PAHs (2-6-ring PAHs) including seven probable human carcinogens (4-6-ring B2-PAHs). The ELISA results were compared to GC-MS summation results for the total 19 target PAHs as well as for the subset of the seven B2-PAH compounds. For all soil samples, the PAH concentrations derived from ELISA were greater than the sum of B2-PAH concentrations obtained by GC-MS. ELISA determinations were also frequently greater than the results obtained by GC-MS for the total 19 PAH compounds. This discrepancy can be expected, since the ELISA is a screening assay for the detection of several related PAHs while the GC-MS procedure detects priority PAH compounds. Thus, only a subset of PAHs (e.g. 19 PAHs) in the soil samples were measured by GC-MS while additional PAHs, including alkylated PAHs, and PAH derivatives have been demonstrated to be cross-reactive in the C-PAH ELISA. Results of paired tests show that the PAH data from ELISA and GC-MS methods are significantly different (P<0.001), but highly correlated. The ELISA data had a strong positive relationship with the GC-MS summation data for the B2-PAHs as well as for the 19 PAHs targeted by the GC-MS method. Results indicate that the ELISA may be useful as a broad screen for monitoring PAHs in environmental samples.  相似文献   

18.
A novel method for theoretical calculation of the type II (β) error in soft independent modeling by class analogy is proposed. It can be used to compare tentatively predicted and empirically observed results of classification. Such an approach can better characterize model quality and thus improve its validation. Method efficiency is demonstrated on the famous Fisher Iris dataset and on a real‐world example of quality control of packed raw materials in pharmaceutical industry. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
We describe a simple method to fabricate an array of polystyrene microbeads (PS μbeads) conjugated with an elastin-like polypeptide (ELP) on a glass surface using a removable polymer template (RPT). A thin layer of adhesive was spun-cast on glass and cured by UV radiation. Micropatterns of an RPT were then transferred onto the surface by microcontact printing. The adhesion of PS μbeads on the surface depended on the adhesion performance of the adhesive layer, which could be adjusted by irradiation time. An array of PS μbeads conjugated with ELP was used for a smart immunoassay of prostate-specific antigen (PSA), a cancer marker. By controlling the phase transition of ELP molecules, PSA molecules were selectively adhered or released from the bead surface. The selective and reversible binding of PSA molecules on the bead surface was characterized with fluorescence microscopy.  相似文献   

20.
An improved competitive indirect immunoassay for the detection of 2,4,6-trichlorophenol (2,4,6-TCP) has been developed and optimized by preparing heterologous haptens that have been evaluated as coating antigens. The relation between the degree of heterology and immunoassay detectability has been investigated according to the geometric and electronic distribution similarities between the haptens and the analyte using molecular modeling tools. The assay has been characterized according to different physicochemical parameters such as the incubation time, the ionic strength, the effect of detergents and the pH. The resulting assay has an IC50 of 1.44 μg l−1 and a limit of detection (LOD) of 0.2 μg l−1 and it shows a good accuracy and suitability to analyze trichlorophenol in drinking water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号