首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
The oxidation of fluvastatin sodium on a glassy carbon electrode has been studied by use of a variety of voltammetric techniques. Different conditions were investigated to optimize the determination of fluvastatin sodium. The dependence of the intensities of currents and potentials on pH, concentration, scan rate, and nature of the buffer was investigated. Oxidation of fluvastatin sodium was found to be diffusion-controlled and irreversible. The best results for the determination of fluvastatin sodium were obtained by using differential pulse and square-wave voltammetric techniques in Britton-Robinson buffer at pH 10.04. Differential pulse and square-wave voltammetry at a glassy carbon electrode resulted in linear calibration in the range 8x10(-6) to 6x10(-4) mol L(-1) and detection limits of 1.07x10(-6) and 7.99x10(-7) mol L(-1), respectively. The proposed methods were successfully applied to the determination of the drug in capsules and biological fluids. Excipients did not interfere with the determination. Statistical validation revealed that the methods were free from significant systematic errors.  相似文献   

2.
The aim of this work was voltammetric determination of 1-aminopyrene and 1-hydroxypyrene using carbon paste electrodes modified with cyclodextrin derivatives and double stranded deoxyribonucleic acid (dsDNA). The detection schemes based on a preconcentration and differential pulse voltammetric (DPV) determination at beta-cyclodextrin and gamma-cyclodextrin modified carbon paste electrode (beta-CD/CPE, gamma-CD/CPE), neutral beta-cyclodextrin polymer and carboxymethyl-beta-cyclodextrin polymer modified screen-printed electrode (beta-CDP/SPE, beta-CDPA/SPE) and dsDNA modified screen-printed electrode (DNA/SPE) are proposed for the trace determination of studied analytes within the concentration range from 2 x 10(-8) to 4 x 10(-7) mol dm(-3) and from 2 x 10(-7) to 4 x 10(-6) mol dm(-3) with the limits of quantification down to 10(-8) mol dm(-3). Depending on pH, 1-aminopyrene interacts with both surface attached CD and DNA by electrostatic bonds and supramolecular complexation while 1-hydroxypyrene associates with the CD hosts via complexation. The 1-aminopyrene interaction with dsDNA was confirmed by fluorimetric measurements in the solution phase using a competing DNA-TO-PRO-3 dye complex. In addition, the effect of temperature on this association was investigated using an electrically heated DNA-modified carbon paste electrode (DNA/CPE).  相似文献   

3.
A Nafion-modified glassy carbon electrode incorporated with tobramycin for the voltammetric stripping determination of Cu2+ has been explored. The electrode was fabricated by tobramycin containing Nafion on the glassy carbon electrode surface. The modified electrode exhibited a significantly increased sensitivity and selectivity for Cu2+ compared with a bare glassy carbon electrode and the Nafion modified electrode. Cu2+ was accumulated in HAc-NaAc buffer (pH 4.6) at a potential of -0.6 V (vs. SCE) for 300 s and then determined by differential pulse anodic stripping voltammetry. The effects of various parameters, such as the mass of Nafion, the concentration of tobramycin, the pH of the medium, the accumulation potential, the accumulation time and the scan rate, were investigated. Under the optimum conditions, a linear calibration graph was obtained in the concentration range of 1.0 x 10(-9) to 5.0 x 10(-7) mol l(-1) with a correlation coefficient of 0.9971. The relative standard deviations for eight successive determinations were 4.3 and 2.9% for 1.0 x 10(-8) and 2.0 x 10(-7) mol l(-1) Cu2+, respectively. The detection limit (three times signal to noise) was 5.0 x 10(-10) mol l(-1). A study of interfering substances was also performed, and the method was applied to the direct determination of copper in water samples, and also in analytical reagent-grade salts with satisfactory results.  相似文献   

4.
Glycine was covalently grafted on to a glassy carbon electrode (GCE) by amine cation radical formation in electrooxidation of the amino-containing compound. X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry proved the immobilization of glycine on the GCE. The modified electrode reduced the overpotentials of dopamine (DA) and ascorbic acid (AA) by approximately 0.15 V and 0.23 V, respectively, and resolved the overlapping voltammetric response of DA and AA into two well-defined voltammetric peaks in cyclic voltammetry (CV) or differential pulse voltammetry (DPV), unlike the unmodified GCE; this can be used for the simultaneous determination of these species in a mixture. The differential pulse peak current was linearly dependent on DA and AA concentration in the range 5 x 10(-6)-8 x 10(-4) mol L(-1) and 6 x 10(-5)-4 x 10(-3) mol L(-1), with correlation coefficients of 0.996 and 0.994, respectively. The detection limits (3delta) for DA and AA were 1.8 x 10(-6) mol L(-1) and 2.1 x 10(-5) mol L(-1), respectively. The modified electrode is very sensitive, selective and stable, and has been applied to the determination of DA and AA simultaneously in samples with satisfactory results.  相似文献   

5.
A reliable and reproducible method for the determination of uric acid in urine samples has been developed. The method is based on the modification of a glassy carbon electrode by 3-acetylthiophene using cyclic voltammetry. The poly(3-acetylthiophene) modified glassy carbon electrode showed an excellent electrocatalytic effect towards the oxidation of uric acid in 0.1 m phosphate buffer solution (PBS) at pH 7.2. Compared with a bare glassy carbon electrode (GCE), an obvious shift of the oxidation peak potential in the cathodic direction and a marked enhancement of the anodic current response for uric acid were observed. The poly(3-acetylthiophene)/GCE was used for the determination of uric acid using square wave voltammetry. The peak current increased linearly with the concentration of uric acid in the range of 1.25 x 10(-5)-1.75 x 10(-4) M. The detection limit was 5.27 x 10(-7) M by square wave voltammetry. The poly(3-acetylthiophene)/GCE was also effective to determine uric acid and ascorbic acid in a mixture and resolved the overlapping anodic peaks of these two species into two well-defined voltammetric peaks in cyclic voltammetry at 0.030 V and 0.320 V (vs. Ag/AgCl) for ascorbic acid and uric acid, respectively. The modified electrode exhibited stable and sensitive current responses toward uric acid and ascorbic acid. The method has successfully been applied for determination of uric acid in urine samples.  相似文献   

6.
The oxidative behaviour of, a hypnotic drug, zolpidem was studied at glassy carbon electrode in Britton-Robinson buffer over the pH range 2.0-11.0 using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug was effected in a single irreversible, diffusion-controlled step. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 8.0 at +0.889 V (vs. Ag/AgCl) on glassy carbon electrode. This process could be used to determine zolpidem concentrations in the range 5.0 x 10(-7) M to 1.0 x 10(-5) M with a detection limit of 2.0 x 10(-7) M. The method was applied, without any interference from the excipients, to the determination of the drug in a tablet dosage form.  相似文献   

7.
beta-Alanine was covalently grafted on a glassy carbon electrode (GCE) by amine cation radical formation in the electrooxidation process of the amino-containing compound. X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry (CV) proved the immobilization of beta-alanine monolayer on GCE. The electrode shows strong electrocatalytic functions to dopamine (DA) and ascorbic acid (AA), reducing the overpotentials by 0.20 V and 0.23 V, respectively. Due to its different catalytic effects toward DA and AA, the modified electrode resolved the overlapping voltammetric responses of DA and AA into two well-defined voltammetric peaks by CV or differential pulse voltammetry (DPV), which can be used for the simultaneous determination of these species in a mixture. The catalytic peak current obtained from DPV was linearly related to DA and AA concentrations in the ranges of 4.0 x 10(-6)-5.0 x 10(-4) mol/L and 2.0 x 10(-5)-6.0 x 10(-3) mol/L with correlation coefficients of 0.997 and 0.995, respectively. The detection limits (3 sigma) for DA and AA were 2.4 x 10(-6) mol/L and 1.2 x 10(-5) mol/L, respectively. The electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of DA and AA simultaneously in samples with satisfactory results.  相似文献   

8.
A novel film electrode for the voltammetric determination of tyrosine has been constructed based on electropolymerization of L-serine on a glassy carbon electrode. Voltammetric behaviour of tyrosine on the poly-L-serine film electrode was investigated with cyclic voltammetry and linear sweep voltammetry, and electrochemical parameters were calculated from chronocoulometry. In optimal conditions, the oxidation peak current of tyrosine on the poly-L-serine film electrode was enhanced greatly. A sensitive oxidation peak at 0.90 V was employed to determine tyrosine. A linearity between the oxidation peak current and the tyrosine concentration was obtained in the range of 3.0 x 10(-7) to 1.0 x 10(-4) mol L(-1) with a detection limit of 1.0 x 10(-7)mol L(-1). The practical application of the film electrode in the determination of tyrosine in a commercial amino acid oral solution demonstrated that it has good selectivity and high sensitivity.  相似文献   

9.
王桂芬  朴元哲 《分析化学》1998,26(12):1490-1493
应用循环伏安法、微分脉冲伏安法对多菌灵在破碳电极上的电化学行为及其测定进行了研究。在pH=9.0的2mol/L NH3-NH4Cl底液中,对其进行循环伏安扫描,发现于0.61V(vs.Ag/AgCl)产生一灵敏的氧化峰。微分脉冲伏安法殉菌灵的检测限为4×10^-8mol/L。多菌灵的浓度在5.0×10^-7 ̄1.0×10^-5mol/L间与微分脉冲伏安峰电流呈线性关系(r=0.9942)。对于1×  相似文献   

10.
Zhang L  Lin X 《The Analyst》2001,126(3):367-370
A novel covalently modified glassy carbon electrode with glutamic acid has been fabricated via an electrochemical oxidation procedure and was applied to the catalytic oxidation of uric acid (UA) and ascorbic acid (AA), reducing the overpotentials by about 0.2 V and 0.3 V, respectively. Based on its strong catalytic function toward the oxidation of UA and AA, the modified electrode resolved the overlapping voltammetric response of UA and AA into two well-defined voltammetric peaks with both cyclic voltammetry (CV) and differential pulse voltammetry (DPV), which can be used for the simultaneous determination of these species in a mixture. The catalytic peak current obtained from DPV was linearly dependent on the UA and AA concentration in the range 2 x 10(-6)-4 x 10(-4) mol L-1 and 1.0 x 10(-6)-4 x 10(-4) mol L-1 with correlation coefficients of 0.996 and 0.997, respectively. The detection limits (3 delta) for UA and AA were 1.1 x 10(-6) mol L-1 and 9.2 x 10(-7) mol L-1, respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of UA and AA simultaneously in human urine samples with satisfactory results.  相似文献   

11.
Yılmaz S  Uslu B  Ozkan SA 《Talanta》2001,54(2):351-360
A voltammetric study of the oxidation of etodolac has been carried out at the glassy carbon electrode. The electrochemical oxidation of etodolac was investigated by cyclic, linear sweep, differential pulse and square wave voltammetry using glassy carbon electrode. Different parameters were tested to optimize the conditions for the determination of etodolac. The dependence of intensities of currents and potentials on pH, concentration, scan rate, nature of the buffer was investigated. For analytical purposes, a very well resolved diffusion controlled voltammetric peak was obtained in Britton-Robinson buffer at pH 2.15 for differential pulse and square wave voltammetric techniques. The linear response was obtained in the ranges of 2.10(-6)-8.10(-5) M with a detection limit of 6.8x10(-7) and 6x10(-6)-8x10(-5) M with a detection limit of 1.1x10(-6) M for differential pulse and square wave voltammetric techniques, respectively. Based on this study, simple, rapid, selective and sensitive two voltammetric methods were developed for the determination of the etodolac in tablet dosage form and human serum.  相似文献   

12.
A sensitive and selective method for the determination of procaine hydrochloride with a Nafion-modified glassy carbon electrode has been developed. The voltammetric behavior of procaine hydrochloride on the Nafion-modified electrode indicated that the modified electrode not only increased the sensitivity of the determination of procaine hydrochloride, but also catalyzed the electrode process. Procaine hydrochloride was accumulated in Britton-Robinson buffer (pH 2.09) at a potential of -0.2 V (vs. SCE) for 180 s, and was then determined by differential pulse adsorptive stripping voltammetry. The effect of various parameters, such as the pH of the medium, the mass of drop-coated Nafion, the accumulation potential, the accumulation time and the scan rate, were investigated. Under the optimum conditions, a linear calibration graph was obtained in the concentration range of 6.0 x 10(-8) to 6.0 x 10(-6) mol l(-1) with a correlation coefficient of 0.9987. The relative standard deviation was 4.18% for eight successive determinations of 1.0 x 10(-7) mol l(-1) procaine hydrochloride, and the detection limit (three times signal to noise) was 7.0 x 10(-9) mol l(-1). A study of interfering substances was also performed, and the method was applied to the direct determinations of procaine hydrochloride in the injection solution of procaine hydrochloride and in rabbit serum.  相似文献   

13.
研究了芦荟大黄素在以 0 .1mol/LHAc (pH 2 .89)为支持电解质 ,玻碳电极为工作电极的吸附伏安行为 .结果表明芦荟大黄素存在一个准可逆的双电子转移过程 ,其峰电流Ip 和峰电位Ep 与溶液 pH值有关 .同时还建立了用 1.5阶微分阳极溶出伏安法测定含量的新方法 .在 - 0 .80V(vs.SCE)电位下富集 ,可得一灵敏的微分阳极溶出峰 ,峰电位Ep 为 - 0 .38V ,峰电流Ip 与芦荟大黄素的浓度在 2 .0× 10 - 7~ 8.0× 10 - 6 mol/L范围内成线性关系 ,最低检出限为 1.0× 10 - 7mol/L .该法用于含有芦荟大黄素体系的测定 ,具有简便、快速、准确等优点  相似文献   

14.
采用循环伏安法和差分脉冲伏安法对水杨酸在电活化玻碳电极上的电化学行为进行研究.在pH7.0的PBS溶液中,将玻碳电极用恒电位法在+1.7V电位阳极氧化400 s.在0.2 mol·L- NaOH溶液中,水杨酸在0.602 V处有一良好的氧化峰,其氧化峰电流与扫描速率在0.02~0.2 V·s-1范围内呈良好线性关系,表...  相似文献   

15.
王鑫  杨梦静  张雷 《分析测试学报》2017,36(11):1325-1332
在1.0 mol·L-1H_2SO_4溶液中,采用循环伏安法(CV)对玻碳电极(GCE)进行电化学处理,得到"活化"的玻碳电极(A-GCE)。在0.1 mol·L-1生理性磷酸盐缓冲溶液(PBS,p H 7.0)中,A-GCE不仅能很好地改善抗坏血酸(AA)、多巴胺(DA)、尿酸(UA)和亚硝酸根(NO_2~-)的电化学行为,而且能将四者的混合溶液在GCE上重叠的弱氧化峰分成4个灵敏的氧化峰,且相邻氧化峰(AA-DA、DA-UA、UA-NO_2~-)之间的电位差(ΔEpa)分别为0.16、0.15、0.45 V,表明A-GCE对AA、DA、UA和NO_2~-具有良好的电催化活性,可用于混合溶液中四者的同时分析。在优化的实验条件下,AA、DA、UA和NO_2~-的差分脉冲伏安(DPV)峰电流与其浓度分别在5~2 100、2~140、1~700、10~1 050μmol·L-1范围内呈良好的线性关系,相关系数分别为0.998 9、0.996 8、0.997 4和0.997 8,检出限分别为0.19、0.45、0.28、0.72μmol·L-1。将A-GCE应用于血清中AA、DA、UA和NO_2~-的同时电化学分析,结果满意。  相似文献   

16.
陈欢  马伟  孙登明 《应用化学》2012,29(5):576-584
用循环伏安法制备了银掺杂聚L-甲硫氨酸修饰玻碳电极,研究了对苯二酚和邻苯二酚在该修饰电极上的电化学行为,建立了同时测定对苯二酚和邻苯二酚的新方法.研究发现,在pH=5.0的磷酸盐缓冲溶液中,扫速为100 mV/s时,对苯二酚和邻苯二酚在银掺杂聚L-甲硫氨酸修饰玻碳电极上均出现1对氧化还原峰,峰电位分别为:Epa=0.228 V、Epc =0.162 V和Epa=0.347 V、Epc =0.287 V,二者的氧化峰电位差达119 mV,还原峰差达125 mV.在最佳的条件下,用差分脉冲伏安法同时测定邻苯二酚和对苯二酚的线性范围为3.00 ×10-6~1.00 ×10-4mol/L,检出限为8.0×10-7 mol/L(对苯二酚)和5.0×10-7 mol/L(邻苯二酚).此法用于废水样中对苯二酚和邻苯二酚的测定,获得满意结果.  相似文献   

17.
A chemically modified electrode based on a chitosan-multiwall carbon nanotube (MWNT) coated glassy carbon electrode (GCE) is described, which exhibits an attractive ability to determine dopamine (DA) and ascorbic acid (AA) simultaneously. The modified electrode exhibited a high differential pulse voltammetry (DPV) current response to DA at 0.144 V and AA at -0.029 V (vs. SCE) in a 0.1 mol l(-1) phosphate buffer solution (pH = 7.2). The properties and behaviors of the chitosan-multiwall carbon nanotube modified electrode (MC/GCE) were characterized using cyclic voltammetry (CV) and DPV methods. The mechanism for the discrimination of dopamine from ascorbic acid at MC/GCE is discussed. The linear calibration range for DA and AA were 5 x 10(-7) mol l(-1) to 1 x 10(-4) mol l(-1) (r = 0.997), and 5 x 10(-6) mol l(-1) to 1 x 10(-3) mol l(-1) (r = 0.996), respectively. The MC/GCE showed good sensitivity, selectivity and stability.  相似文献   

18.
采用线性循环溶出伏安法和差分脉冲溶出伏安法对磺胺嘧啶在电活化玻碳电极上的电化学行为进行了研究。玻碳电极在PBS溶液中(pH 7.0),用恒电位法在1.7 V阳极氧化400 s,在B-R缓冲溶液中,磺胺嘧啶在1.02V(vs.Ag/AgCl)处有一良好的氧化峰,在0.02~0.25 V/s范围内,其氧化峰电流与扫描速率呈良好线性关系,表明电极过程为受吸附控制的不可逆过程。差分脉冲溶出伏安法的氧化峰电流(Ipa)与磺胺嘧啶浓度1×10-6~1×10-4mol/L范围内呈良好的线性关系(r=0.9977),检出限为8.7×10-7mol/L(S/N=3)。方法已用于分析磺胺嘧啶片剂的分析。  相似文献   

19.
A glassy carbon electrode modified with a coating of polypyrrole (Ppy) exhibited an attractive performance for the detection and determination of a non-steroidal and non-narcotic analgesic compound, ketorolac tromethamine (KT). Cyclic voltammetry, differential pulse and square wave voltammetry were used in a combined way to identify the electrochemical characteristics and to optimize the conditions for detection. For calibrating and estimating KT, square-wave voltammetry was mainly used. The drug shows a well-defined peak at -1.40 V vs. Ag/AgCl in the acetate buffer (pH 5.5). The existence of Ppy on the surface of the electrode gives higher electrochemical active sites at the electrode for the detection of KT and preconcentrate KT by adsorption. The square-wave stripping voltammetric response depends on the excitation signal and the accumulation time. The calibration curve is linear in the range 1 x 10(-11) to 1 x 10(-7) M with a detection limit of 1.0 x 10(-12) M. Applicability to serum samples was also demonstrated. A detection limit of 1.0 ng ml for serum was observed. Square-wave voltammetry shows superior performance over UV spectroscopy and other techniques.  相似文献   

20.
制备了金纳米粒子/碳纳米管修饰玻碳电极(AuNPs-CNTs/GCE),采用循环伏安法和线性扫描伏安法研究了4-壬基酚在修饰电极上的电化学行为,并建立了一种灵敏简便地检测4-壬基酚的电化学方法。优化了pH值、扫描速率、富集时间等测定参数,并计算出pH值与氧化峰电压、扫描速率与氧化峰电流之间的数量关系。在pH 10.0的BR缓冲溶液中,4-壬基酚在AuNPs-CNTs/GCE上出现灵敏的氧化峰,氧化电位为0.51 V。与裸玻碳电极(GCE)和单一碳纳米管修饰电极(CNTs/GCE)相比,AuNPs-CNTs/GCE明显提高了4-壬基酚的氧化电流。在优化实验条件下,4-壬基酚的浓度分别在0.05~4μmol/L和6~14μmol/L范围内与氧化峰电流呈良好的线性关系,检出限为0.023μmol/L,对于实际样品测定的回收率为95%~104%。该修饰电极具有良好的重现性和稳定性,可用于环境样品中4-壬基酚的直接检测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号