首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A swept-wavelength source is created by connecting four elements in series: a femtosecond fiber laser at 1.56 μm, a non-linear fiber, a dispersive fiber and a tunable spectral bandpass filter. The 1.56-μm pulses are converted to super-continuum (1.1–2.2 μm) pulses by the non-linear fiber, and these broadband pulses are stretched and arranged into wavelength scans by the dispersive fiber. The tunable bandpass filter is used to select a portion of the super-continuum as a scan-wavelength output. A variety of scan characteristics are possible using this approach. As an example, an output with an effective linewidth of approximately 1 cm-1 is scanned from 1350–1550 nm every 20 ns. Compared to previous scanning benchmarks of approximately 1 nm/μs, such broad, rapid scans offer new capabilities: a gas sensing application is demonstrated by monitoring absorption bands of H2O, CO2, C2H2 and C2H6O at a pressure of 10 bar. Received: 5 August 2002 / Revised version: 23 September 2002 / Published online: 22 November 2002 RID="*" ID="*"Corresponding author. Fax: +1-608/265-2316, E-mail: ssanders@engr.wisc.edu  相似文献   

2.
We describe a near-infrared in situ tunable diode laser spectrometer developed for atmospheric measurements of CH4 in the upper troposphere and lower stratosphere (UT/LS). The instrument is designed to provide fast-response (0.5–1 Hz) measurements and operate autonomously on the NASA WB-57F high-altitude aircraft. A single-mode InGaAsP distributed feedback laser diode operating at 1.6537 μm scans continuously over the R(3) rotation–vibration transition in the 2ν3 band. We use a direct absorption technique incorporating a custom-designed long path length (252 m) low-volume (3.6 L) astigmatic Herriott cell. The present detection sensitivity is 5×1010 molecules cm-3, corresponding to ∼20 ppbv in the UT/LS, with the main limit to instrument precision being background optical interference fringes. In-flight performance is demonstrated by presentation of recent data. Received: 25 January 2002 / Revised version: 5 April 2002 / Published online: 21 August 2002 RID="*" ID="*"Corresponding author. Fax: +1-303/497-5373, E-mail: richard@al.noaa.gov  相似文献   

3.
We present the first photoacoustic spectrometer for gas sensing employing both the fundamental and the frequency-doubled radiation of a continuously tunable high-pressure CO2 laser with room temperature operation. A quasi-phase-matched diffusion-bonded GaAs crystal is used in the system for second-harmonic generation. A pulsed photoacoustic detection scheme with a non-resonant cell, equipped with an 80-microphone array, is employed. The wide continuous tuning range in the fundamental (9.2–10.7 μm) and the frequency-doubled (4.6–5.35 μm) regimes, together with the narrow linewidth of 540 MHz (0.018 cm-1) for the 10-μm region and of 1050 MHz (0.0315 cm-1) for the 5-μm region, allow the measurement of gas mixtures, individual species and isotope discrimination. This is illustrated with measurements on NO and CO2. The measured isotope ratio 15 NO/14 NO=(3.58±0.55)×10-3 agrees well with the literature (3.700×10-3) and demonstrates the good selectivity of the system. Received: 30 April 2002 / Revised version: 10 June 2002 / Published online: 2 September 2002 RID="*" ID="*"Corresponding author. Fax: +41-1/633-1077, E-mail: sigrist@iqe.phys.ethz.ch  相似文献   

4.
A new laser medium – Yb,Tm:KY(WO4)2 – for diode pumped solid state laser applications operating around 1.9 to 2.0 μm has been investigated and the main laser characteristics are presented. Diode pumping at 981 nm and around 805 nm was realised. For 981-nm pumping, the excitation occurs into Yb3+ ions followed by an energy transfer to Tm3+ions. A slope efficiency of 19% was realised. For pumping around 805 nm, the excitation occurs directly into the Tm3+ ions. Here a maximum slope efficiency of 52%, an optical efficiency of 40%, and output powers of more than 1 W were realised. Using a birefringent quartz plate as an intracavity tuning element, the tunability of the Yb,Tm:KY(WO4)2 laser in the spectral range of 1.85–2.0 μm has been demonstrated. The possibility of laser operation in a microchip cavity configuration for this material has also been shown. Received: 12 March 2002 / Revised version: 20 May 2002 / Published online: 25 September 2002 RID="*" ID="*"Corresponding author. Fax: +49-531/592-4116, E-mail: stefan.kueck@ptb.de  相似文献   

5.
20-Hz operation of an eye-safe cascade Raman laser with a Ba(NO3)2 crystal   总被引:3,自引:0,他引:3  
Operation of a 1.598-μm eye-safe third-Stokes Raman laser with a Ba(NO3)2 crystal pumped by a 1.064-μm Nd:YAG laser is described. We observed a substantial decrease in the output energy during the first 50 s of the continuous operation at 20 Hz. The energy drop is ∼76% of the initial third-Stokes output. We confirmed negative thermal lensing and thermally induced birefringence in the crystal. With a concave cavity mirror at a matched curvature to the thermal lensing, we obtained an output energy of 11 mJ at 20 Hz. TEM00 output was also obtained with a smaller pump-beam diameter with a highest conversion efficiency of 15.5% for a pumping power of only 45 MW/cm2 (0.9 J/cm2). Received: 20 November 2001 / Revised version: 20 February 2002 / Published online: 2 May 2002  相似文献   

6.
We report, to our knowledge, the first active channel waveguide in Ti:sapphire. We have created ∼1.4-μm high ribs in a ∼10-μm thick Ti:sapphire planar waveguide by reactive ion etching. Following excitation by an Ar-ion laser, the rib structure showed channel-waveguide fluorescence emission. The mode profiles and the beam-parameter values (M2) were measured. The coupling efficiency of fluorescence emission into a single-mode fiber was an order of magnitude higher than for fluorescence from unstructured planar regions of the waveguide. Such devices are of interest as low-threshold tunable lasers and as broadband light sources in low-coherence interferometry. Received: 22 December 2002 / Revised version: 30 March 2002 / Published online: 8 August 2002  相似文献   

7.
A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4–4.5 μm region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal, DFG power levels of 10 μW were generated at approximately 4 μm in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating near 713 nm and 871 nm, respectively, using a laser pump power of 300 mW. A quasi-phase-matched infrared wavelength-tuning bandwidth (FWHM) of ∼12 cm-1 and a temperature tuning rate of 1.02 cm-1/°C were achieved. Experimental details regarding the feasibility of trace gas detection based on absorption spectroscopy of CO2 in ambient air using this DFG radiation source are also described. Received: 23 October 2000 / Revised version: 22 January 2001 / Published online: 27 April 2001  相似文献   

8.
We demonstrate that Yb-doped Ca4GdO(BO3)3 (GdCOB) crystals are suitable for the development of high-power diode-pumped lasers emitting at around 1.04 μm. A 15%-doped Yb:GdCOB crystal was longitudinally pumped with a cw fiber-coupled diode emitting 10 W at 976 nm. While 5.2 W of diode power was absorbed, we obtained 3.2 W of 1043-μm laser light, with a beam quality factor M2 equal to 3, and 2.5 W in a diffraction-limited beam. Furthermore, the laser is continuously tunable between 1018 and 1086 nm. Thermal effects have been investigated with a Shack–Hartmann wavefront analyser: although thermal lensing is not negligible, it does not affect the performance of the laser with the resonator design we used. Received: 1 August 2000 / Revised version: 18 September 2000 / Published online: 21 February 2001  相似文献   

9.
The Er:YAG and the CO2 laser are competitors in the field of hard tissue ablation. The use of Er:YAG lasers (2.94 μm, pulse length L of 100 to 200 μs) show smaller areas of thermal defects then ‘‘superpulsed’’ CO2 lasers with pulse lengths of approximately 100 μs. Only the development of a Q-switched CO2 laser (9.6 μm, τL=250 ns) allowed for similar results. In this paper new results for the Er:YAG and the Q-switched CO2 laser under the influence of water spray will be presented. Several parameters are of special interest for these investigations: the specific ablation energy, which shows a minimum for the CO2 laser at an energy density of 9 J/cm 2 and a broad shallow minimum in the range of 10 to 70 J/cm2 for the Er:YAG laser, and comparison of the cut-shape and depth. Surface effects and cutting velocity are discussed based on SEM pictures. Received: 19 July 2000 / Revised version: 1 November 2000 / Published online: 30 November 2000  相似文献   

10.
We report on the first layer growth of a Mn6+-doped material. Large-size BaSO4 substrates of 10×6×4 mm3 were grown from a LiCl solvent by the flux method. Flat surfaces of undoped BaSO4 were then achieved by use of liquid-phase epitaxy (LPE) from a CsCl–KCl–NaCl solvent. Finally, BaSO4:Mn6+ layers were grown by LPE with growth velocities of approximately 3 μm h-1, at temperatures of 550–508 °C. Absorption, luminescence, luminescence-excitation and luminescence-decay measurements confirmed the incorporation of manganese solely in its hexavalent oxidation state. This material possesses potential as a near-infrared tunable laser with a wavelength range larger than Ti:sapphire. Received: 7 January 2002 / Revised version: 30 March 2002 / Published online: 8 August 2002  相似文献   

11.
The partially deuterated isotopes of methanol, CH2DOH and CHD2OH, have been reinvestigated as sources of far-infrared (FIR) laser emissions using an optically pumped molecular laser (OPML) system recently designed for wavelengths below 150 μm. With this system, 10 new FIR laser emissions from these isotopes ranging from 32.8 to 174.6 μm have been discovered. This includes the shortest known OPML emission from CHD2OH, at 32.8 μm. These lines are reported with their operating pressure, polarizations relative to the CO2 pump laser and wavelengths, measured to ±0.5 μm. In addition, polarizations for three previously observed FIR laser lines from CHD2OH were measured for the first time. This paper is dedicated to the memory of Dr. K.M. Evenson, a pioneer in the field for his role in the development of optically pumped molecular lasers and their use in laser frequency measurements and the laser magnetic resonance technique. His scientific expertise, guidance, mentoring and friendship will be greatly missed. Received: 27 March 2002 / Published online: 8 May 2002  相似文献   

12.
4 (PPKTP). We generated 12 μW of radiation tunable around 1.6 μm by difference-frequency mixing of the outputs of a frequency-doubled Nd:YLF laser at 523 nm (240 mW) and a tunable Ti:sapphire laser near 760 nm (340 mW). A temperature tuning rate of 0.73 nm/°C for the generated wavelength and a FWHM temperature acceptance bandwidth of 6.9 °C cm was observed. The effective d33 coefficient was estimated to be ∼5 pm/V. Received: 02 September 1998  相似文献   

13.
2 and two diode lasers as pump sources are presented. A single-mode Fabry–Pérot-type tunable diode laser (TDL) and an external-cavity diode laser (ECL) were combined to generate radiation in the mid-infrared region near 7.2 μm. With a TDL at a wavelength of approximately 1290 nm and an ECL emitting between 1504 and 1589 nm it was possible to carry out spectroscopic experiments concerning SO2 at five different phasematching points between 1350 and 1400 cm-1 by fixing the wavelength of one pump laser and tuning the wavelength of the other. With an input power of 8 mW for the single-mode Fabry–Pérot-type diode laser and 6 mW for the external-cavity laser an output power of about 10 nW was generated. Using the tuning capabilities of the external-cavity laser a spectral region up to 5 cm-1 could be covered within one scan. Measurements of SO2 absorption lines at low pressure demonstrate the high-resolution features of the spectrometer. Moreover, these data provide new direct experimental phasematching data for the rarely investigated spectral region at 7.2 μm. Received: 27 October 1997/Revised version: 8 May 1998  相似文献   

14.
A new strong erbium laser glass (SELG) based on a boro-alumo-phosphate composition is reported. We discuss the synthesis and chemical properties together with spectroscopic and thermo-mechanical data. The new glass composition shows excellent laser performance and withstands high-average power pump radiation. We present laser results at 1.54 μm from flashlamp and laser pumping. In tests with laser-diode pumped Q-switched Er-Yb microchip lasers, we have achieved up to 150 mW of average output power and generated 1.2 kW in peak power. Co2+:MgAl2O4 was here used as the saturable absorber. Received: 21 December 2001 / Revised version: 14 April 2002 / Published online: 8 August 2002  相似文献   

15.
Non-cryogenic, laser-absorption spectroscopy in the mid-infrared has wide applications for practical detection of trace gases in the atmosphere. We report measurements of nitric oxide in air with a detection limit less than 1 nmole/mole (<1 ppbv) using a thermoelectrically cooled quantum cascade laser operated in pulsed mode at 5.26 μm and coupled to a 210-m path length multiple-pass absorption cell at reduced pressure (50 Torr). The sensitivity of the system is enhanced by operating under pulsing conditions which reduce the laser line width to 0.010 cm-1 (300 MHz) HWHM, and by normalizing pulse-to-pulse intensity variations with temporal gating on a single HgCdTe detector. The system is demonstrated by detecting nitric oxide in outside air and comparing results to a conventional tunable diode laser spectrometer sampling from a common inlet. A detection precision of 0.12 ppb Hz-1/2 is achieved with a liquid-nitrogen-cooled detector. This detection precision corresponds to an absorbance precision of 1×10-5 Hz-1/2 or an absorbance precision per unit path length of 5×10-10 cm-1 Hz-1/2. A precision of 0.3 ppb Hz-1/2 is obtained using a thermoelectrically cooled detector, which allows continuous unattended operation over extended time periods with a totally cryogen-free instrument. Received: 1 May 2002 / Revised version: 6 June 2002 / Published online: 21 August 2002 RID="*" ID="*"Corresponding author. Fax: +1-978/663-4918, E-mail: ddn@aerodyne.com  相似文献   

16.
By optically pumping the deuterated isotopomers of 14NH3 and 15NH3 using 12C16O2, 13C16O2, 12C18O2, and 13C18O2 lasers, several new far-infrared (FIR) emission lines between 65 μm and 125 μm have been detected. The existing spectroscopy of 14N-ammonia isotopomers has been used to identify many of these lines, as well as some previously observed but unidentified. The spectroscopic data have been analyzed to predict over 20 additional FIR laser lines that could be pumped by a more capable CO2 laser. This effort was motivated by a need for strong laser lines in frequency coincidence with molecular transitions of astrophysical interest. Of particularnote is the measurement of the 2680-GHz line of 14NHD2, whose frequency is 4.9 GHz higher than that of the important J=1-0 line of interstellar HD. Received: 25 July 2002 / Published online: 20 December 2002 RID="*" ID="*"Corresponding author. Fax: +1-303/492-5941, E-mail: boreiko@spot.colorado.edu  相似文献   

17.
The development of a compact tunable mid-IR laser system at 3.5 μm for quantitative airborne spectroscopic trace gas absorption measurements is reported. The mid-IR laser system is based on difference frequency generation (DFG) in periodically poled LiNbO3 and utilizes optical fiber amplified near-IR diode and fiber lasers as pump sources operating at 1083 nm and 1562 nm, respectively. This paper describes the optical sensor architecture, performance characteristics of individual pump lasers and DFG, as well as its application to wavelength modulation spectroscopy employing an astigmatic Herriott multi-pass gas absorption cell. This compact system permits detection of formaldehyde with a minimal detectable concentration (1σ replicate precision) of 74 parts-per-trillion by volume (pptv) for 1 min of averaging time and was achieved using calibrated gas standards, zero air background and rapid dual-beam subtraction. This corresponds to a pathlength-normalized replicate fractional absorption sensitivity of 2.5×10-10 cm-1. Received: 29 April 2002 / Published online: 21 August 2002 RID="*" ID="*"Corresponding author. Fax: +1-303/497-1492, E-mail: dr@ucar.edu  相似文献   

18.
The progress in the development of a sensor for the detection of trace air constituents to monitor spacecraft air quality is reported. A continuous-wave (cw), external-cavity tunable diode laser centered at 1.55 μm is used to pump an optical cavity absorption cell in cw-cavity ringdown spectroscopy (cw-CRDS). Preliminary results are presented that demonstrate the sensitivity, selectivity and reproducibility of this method. Detection limits of 2.0 ppm for CO, 2.5 ppm for CO2, 1.8 ppm for H2O, 19.4 ppb for NH3, 7.9 ppb for HCN and 4.0 ppb for C2H2 are calculated. Received: 3 April 2002 / Revised version: 3 June 2002 / Published online: 21 August 2002 RID="*" ID="*"Corresponding author. Fax: +1-202/994-5873, E-mail: Houston@gwu.edu  相似文献   

19.
A single-frequency VCSEL has been used for the first time for high-resolution spectroscopy near 1.5 μm. The incorporated buried-tunnel-junction technology enabled the realization of a long-wavelength InGaAlAs/InP VCSEL with low threshold current (0.925 mA), high output powers (0.576 mW) and low series resistance (60 Ω). The high-speed tuning capability of the long-wavelength VCSEL was investigated and used to conduct high-speed absorption spectroscopy. The peak tuning speed was measured to be 3.4 cm-1/μs and a 4.5-cm-1-wide NH3 spectrum was recorded in 2 μs. The VCSEL was used to measure highly resolved low-pressure spectra for pressures ranging from 9.6 mbar to 1 bar. The measured Doppler-broadened linewidth of 0.02 cm-1 agrees within 3% with the theoretical calculations. The availability and various advantages of 1.3–2-μm single-frequency VCSELs as compared to edge-emitting diode lasers, such as a large current tuning range even at very high tuning frequencies, and low production costs, should significantly expand the application fields for near-infrared laser gas sensors. Received: 17 July 2002 / Revised version: 4 December 2002 / Published online: 12 May 2003 RID="*" ID="*"Corresponding author. Fax: +43-1/58801-15999, E-mail: Gerhard@Totschnig.com  相似文献   

20.
CO2 laser-induced plasma CVD synthesis of diamond   总被引:1,自引:0,他引:1  
2 laser maintenance of a stationary optical discharge in a gas stream, exhausting over a substrate into the air (laser plasmatron). Nano- and polycrystalline-diamond films were deposited on tungsten substrates from atmospheric-pressure Xe(Ar):H2:CH4 gas mixtures at flow rates of 2 ?/min. A 2.5-kW CO2 laser focused beam produced plasma. The deposition area was about 1 cm2 and growth rates were up to 30–50 μm/h. Peculiarities and advantages of laser plasmatrons are discussed. Received: 15 January 1998/Accepted: 16 January 1998  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号