首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A theoretical study on the retention behaviour and chromatographic performance of neutral solutes using a lauryl methacrylate‐based monolithic column under voltage gradient mode in CEC was carried out. Through a flexible mathematical function based on a modified Gaussian model, the peak shape of compounds was firstly fitted under constant and gradient voltage. Using the peak shape parameters and retention time, the estimation of global chromatographic performance, efficiency and peak capacity under several voltage conditions was performed. The influence of voltage gradient on the separation efficiency is discussed and simple equations are presented to calculate retention and peak widths under voltage gradient conditions. A comparison in terms of chromatographic performance of a test mixture of neutral solutes under constant and gradient voltage modes was also carried out. The experiments carried out under gradient voltage showed better efficiencies (172 000 plates/m) and lower peak widths than those obtained under constant voltage (52 000 plates/m).  相似文献   

2.
A fast ion chromatographic system is described which uses shorter column lengths and compares various eluent profiles in order to maximise the performance without sacrificing the chromatographic resolution. Both isocratic and gradient elution profiles were considered to find the most efficient mode of separation. The separation and determination of seven target anions (chloride, chlorate, nitrate, chromate, sulfate, thiocyanate and perchlorate) was achieved using a short (4 mm ID, 50 mm long) column packed with Dionex AS20 high-capacity anion exchange material. A hydroxide eluent was used at an initial concentration of 25 mM (at a flow-rate of 1.0 mL/min) and two performance maxima were found. The maximum efficiency occurred at a normalised gradient ramp rate of 5 mM/t0, resulting in a peak capacity of 16, while the fastest separation (<3 min) occurred at a normalised ramp rate of 30 mM/t0. The retention time, peak width and resolution using the different eluent profiles on varying column lengths is also compared. Further investigations in this study determined that the highest peak capacity separation under gradient conditions could be approximated using an isocratic separation. The advantage of using this novel approach to approximate the maximum efficiency separation removes the need for column re-equilibration that is required for gradient elution resulting in faster analyses and enhanced sample throughput, with benefits in particular for multidimensional chromatography.  相似文献   

3.
In this study, high-efficiency LC–MS/MS separations of complex proteolytic digests are demonstrated using 50 mm, 250 mm, and 1 m long poly(styrene-co-divinylbenzene) monolithic capillary columns. The chromatographic performance of the 50 and 250 mm monoliths was compared at the same gradient steepness for gradient durations between 5 and 150 min. The maximum peak capacity of 400 obtained with a 50 mm column, increased to 485 when using the 250 mm long column and scaling the gradient duration according column length. With a 5-fold increase in column length only a 20% increase in peak capacity was observed, which could be explained by the larger macropore size of the 250 mm long monolith. When taking into account the total analysis time, including the dwell time, gradient time and column equilibration time, the 50 mm long monolith yielded better peptide separations than the 250 mm long monolithic column for gradient times below 80 min (nc = 370). For more demanding separation the 250 mm long monolith provided the highest peak production rate and consequently higher sequence coverage. For the analysis of a proteolytic digest of Escherichia coli proteins a monolithic capillary column of 1 m in length was used, yielding a peak capacity of 1038 when applying a 600 min gradient.  相似文献   

4.
Fekete S  Fekete J 《Talanta》2011,84(2):416-423
The performance of 5 cm long narrow-bore columns packed with 2.6-2.7 μm core-shell particles and a column packed with 1.7 μm totally porous particles was compared in very fast gradient separations of polar neutral active pharmaceutical compounds. Peak capacities as a function of flow-rate and gradient time were measured. Peak capacities around 160-170 could be achieved within 25 min with these 5 cm long columns. The highest peak capacity was obtained with the Kinetex column however it was found that as the flow-rate increases, the peak capacity of the new Poroshell-120 column is getting closer to that obtained with the Kinetex column. Considering the column permeability, peak capacity per unit time and per unit pressure was also calculated. In this comparison the advantage of sub-3 μm core-shell particles is more significant compared to sub-2 μm totally porous particles. Moreover it was found that the very similar sized (dp = 2.7 μm) and structured (ρ = 0.63) new Poroshell-120 and the earlier introduced Ascentis Express particles showed different efficiency. Results obtained showed that the 5 cm long narrow bore columns packed with sub-3 μm core-shell particles offer the chance of very fast and efficient gradient separations, thus these columns can be applied for fast screening measurements of routine pharmaceutical analysis such as cleaning validation.  相似文献   

5.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   

6.
Small columns packed with core-shell and sub-2 μm totally porous particles and monolith columns are very popular to conduct fast and efficient chromatographic separations. In order to carry out fast separations, short (2-5 cm) and narrow-bore (2-2.1 mm) columns are used to decrease the analyte retention volume. Beside the column efficiency, another significant issue is the extra-column band-spreading. The extra-column dispersion of a given LC system can dramatically decrease the performance of a small very efficient column. The aim of this study was to compare the extra-column peak variance contribution of several commercially available LC systems. The efficiency loss of three different type 5 cm long narrow bore, very efficient columns (monolith, sub-2 μm fully porous and sub-2 μm core-shell packing) as a function of extra-column peak variance, and as a function of flow rate and also kinetic plots (analysis time versus apparent column efficiency) are presented.  相似文献   

7.
A monolithic C18-bonded silica rod column (Merck Chromolith) was compared to particle-based C18 and amide C16 sorbents in the HPLC separation of eight microcystins and nodularin-R. Two gradient mobile phases of aqueous trifluoroacetic acid modified with acetonitrile or methanol, different flow-rates and different gradient lengths were tested. The performance of the Chromolith column measured as the resolution of some microcystin pairs, the selectivity, efficiency (peak width) and peak asymmetry equalled, or exceeded, the performance of traditional particle-based columns. The Chromolith column allowed a shortening of the total analysis time to 4.3 min with a flow-rate 4 ml min(-1).  相似文献   

8.
A liquid chromatography/mass spectrometry (LC/MS) method for the analysis of complex mixtures of nucleoside mono-, di- and triphosphates has been developed. A short capillary column (35mm x 0.3mm i.d.) was operated under ion-pair high-performance liquid chromatography conditions and hyphenated to (negative) electrospray (tandem) mass spectrometry. As such, the separation of 12 nucleotides was performed by a binary gradient elution using CH(3)OH/H(2)O and N,N-dimethylhexylamine (N,N-DMHA) as ion-pairing agent. The influence of different N,N-DMHA concentrations on the chromatographic and mass spectrometric performance was evaluated to achieve optimal LC/MS conditions. In addition it was demonstrated that a controlled admission of ammonium dihydrogen phosphate (NH(4)H(2)PO(4)) improved both chromatographic performance and mass spectrometric detection. Because the system was hyphenated to an orthogonal designed electrospray interface (Z-spraytrade mark), long acquisition times were possible without loss of sensitivity.  相似文献   

9.
The IonPac AS14A is a recently developed stationary phase that was produced using a new block-grafting technique, which enables the preparation of high-water-content anion exchangers with excellent peak shape and good chromatographic efficiency. The performance of this column for the analysis of inorganic anions was compared to that obtained using an IonPac AS4A column, which is specified in US Environmental Protection Agency Method 300.0, in addition to another commonly used alternative; the AS14 column. The AS14A column is available in two different formats; 250×4 mm I.D. (7.0 μm diameter particle) and 150×3 mm I.D. (5.5 μm diameter particle). The IonPac AS14A (in 4 mm I.D. format) was found to provide similar performance to the AS14 column with increased peak efficiency and better pH stability and is a suitable alternative for the analysis of anions in moderate- to high-ionic-strength samples. The IonPac AS14A (in 3 mm I.D. format) provides comparable run times to the AS4A column with better overall peak selectivity and improved fluoride resolution, hence this column would be a suitable column to substitute in place of either the AS4A or AS14 columns for the analysis of inorganic anions in low- to moderate-ionic-strength environmental waters. The AS14A column used with an Atlas electrolytic suppressor provides equivalent method detection limits to those obtained when using a micromembrane suppressor but with the operational convenience of a self-regenerating suppressor.  相似文献   

10.
吴顺  郝卫强  岳邦毅  张培培  狄斌  陈强 《色谱》2015,33(6):558-562
在梯度液相色谱中,溶剂混合以及轴向扩散等因素会使梯度曲线发生变形,而这在阶梯梯度以及高斜率的线性梯度中表现得尤为明显。本文探讨了这种梯度曲线变形对色谱峰宽的影响。首先以C18色谱柱为固定相,甲醇-水为流动相,联苯和苯乙酮为样品,测得不同线性梯度和阶梯梯度条件下的色谱峰。然后以205 nm为检测波长,记录相应条件下未接色谱柱时甲醇的响应值,得到柱入口处的梯度曲线。接着根据所设定的梯度条件以及柱入口处测得的梯度曲线,分别计算相应情形中色谱峰宽的理论值,将其与实验值进行了比较。研究结果表明,梯度曲线的变形会对色谱峰宽产生影响。当将这种影响考虑在内后,理论值与实验值更为吻合。  相似文献   

11.
The paper describes the steps taken by the authors to move from a fast to a ballistic gradient in routine liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of plasma samples from pharmacokinetic (PK) profiling of new chemical entities. The reduction of column dimensions from 50 x 4.6 mm to 30 x 2.1 mm followed by optimization of chromatographic separation led to a decrease in the typical runtime from 5 (fast) to 2 min (ballistic) using an API4000 tandem mass spectrometer in Turbo Ionspray mode for detection. Three analytical standards representing typical molecular structures from our sample repository were used to spike plasma from four different species (rat, dog, human and mouse). Two different approaches were used to evaluate matrix effect: post-column infusion and comparison of the peak areas of neat standards and standards spiked after extraction into different pools of plasma; the influence of PEG400 as a typical dosing vehicle was also considered. Two different protein precipitation procedures were taken into account for sample extraction prior to injection. Peak shape, width and height, selectivity and sensitivity of the method were taken into account for chromatographic evaluation. The ballistic method was successfully cross-validated with the conventional fast gradient chromatographic assay.  相似文献   

12.
Four different organic solvents: dimethylformamide, 1,4-dioxane, n-propanol and ethanol were evaluated as alternative organic modifiers to acetonitrile for liquid chromatography (LC) separations. The aim was to establish common sets of chromatographic conditions that could be applied for LC hyphenation to inductively coupled plasma mass spectrometry (ICPMS) as well as to electrospray ionization MS (ESIMS). The approach was to evaluate candidate solvents that, compared to acetonitrile, potentially could give improved analytical performance (low solvent vapor loading, maximized analyte sensitivity and minimized carbon depositions on instrumental parts) in ICPMS analysis while retaining chromatographic and ESIMS performances. The study showed that dimethylformamide, 1,4-dioxane, n-propanol and ethanol all can be advantageous chromatographic modifiers for LC–ICPMS analysis, giving superior performance compared to acetonitrile. For the combined use of LC–ICPMS and LC–ESIMS with a common set of chromatographic conditions, n-propanol gave the best overall performance. The 195Pt+ signal in ICPMS was continuously monitored during a 0–60% organic solvent gradient and at 25% of organic modifier, 100% of the signal obtained at the gradient start was preserved for n-propanol compared to only 35% of the signal when using acetonitrile. Platinum detection limits were 5–8 times lower using n-propanol compared with acetonitrile. Signal-to-noise ratio in continuous ESIMS signal measurements was 100, 90 and 110 for a 100 μg/ml solution of leucine–enkephaline using acetonitrile, ethanol and n-propanol, respectively. Chromatographic efficiency in reversed phase separations was preserved for n-propanol compared to acetonitrile for the analysis of the whole protein cytochrome C and the peptide bacitracin on a column with particle and pore sizes of 5 μm and 300 Å, but slightly deteriorated for the separation of the peptides leucine–enkephaline and bacitracin on a 3 μm and 90 Å column as the peak width at half height for both peptides increased by a factor of two. The performance on the smaller dimensioned column could however be improved by running the separations at 40 °C.  相似文献   

13.
An approach for rapid optimization of dual-mode gradient high performance liquid chromatography (HPLC) by response surface methodology (RSM) was developed for fast simultaneous separation of hydrophilic and hydrophobic components in Radix et Rhizoma Salviae Miltiorrhizae (Danshen) and its preparations. The aim of this study was to achieve a high throughput RSM optimization using a short ultra-high performance liquid chromatographic (UHPLC) column to simultaneously optimize flow rate and solvent gradient, and then transfer the optimized method to conventional HPLC for routine analytical purposes. The optimization was designed with Box Behnken design (BBD) and the global Derringer's desirability was used for describing the multicriteria response variables. Sixty-two designed experiments were performed by UHPLC with a short sub-2 μm column (2.1 mm × 50 mm, 1.7 μm) and a total running time of only 5 h. The predicted gradient profile was further transferred to a long UHPLC column (2.1 mm × 100 mm, 1.7 μm) and a conventional HPLC columns (2.1 mm × 100 mm, 3.5 μm and 4 mm × 100 mm, 5 μm, respectively). Compared to the published methods, the newly developed dual-mode gradient is faster and more efficient at simultaneously separating hydrophilic and hydrophobic components in Danshen and its preparations.  相似文献   

14.
婴儿配方奶粉样品用水超声溶解后,用乙腈超声提取30min,以15 000r·min^-1转速在5℃下离心10min,残渣用乙酸乙酯提取,合并两次提取液。上层有机相于40℃下用氮气吹至近干,加入50%(体积分数)甲醇溶液溶解,溶解液过0.22μm滤膜,采用柱切换-液相色谱法测定滤液中4种雌激素的含量。以Thermo BioBasic SEC-120色谱柱为净化柱,Waters XBridge BEH C18色谱柱为分析柱,用水和甲醇以不同比例混合的溶液为流动相进行梯度洗脱,用紫外检测器测定。4种雌激素的质量浓度均在1.0~20μg·L^-1内与其对应的峰面积呈线性关系,测定下限(10S/N)为0.1~0.3μg·kg^-1。以空白样品为基体进行加标回收试验,所得回收率为90.0%~105%,测定值的日内相对标准偏差(n=6)为1.6%~5.4%,日间相对标准偏差(n=11)为3.5%~6.2%。  相似文献   

15.
An experimental study was performed to investigate the effects of column parameters and gradient conditions on the separation of intact proteins using styrene-based monolithic columns. The effect of flow rate on peak width was investigated at constant gradient steepness by normalizing the gradient time for the column hold-up time. When operating the column at a temperature of 60 °C a small C-term effect was observed in a flow rate range of 1–4 μL/min. However, the C-term effect on peak width is not as strong as the decrease in peak width due to increasing flow rate. The peak capacity increased according to the square root of the column length. Decreasing the macropore size of the polymer monolith while maintaining the column length constant, resulted in an increase in peak capacity. A trade-off between peak capacity and total analysis time was made for 50, 100, and 250 mm long monolithic columns and a microparticulate column packed with 5 μm porous silica particles while operating at a flow rate of 2 μL/min. The peak capacity per unit time of the 50 mm long monolithic column with small pore size was superior when the total analysis time is below 120 min, yielding a maximum peak capacity of 380. For more demanding separations the 250 mm long monolith provided the highest peak capacity in the shortest possible time frame.  相似文献   

16.
Two polystyrene-based capillary monolithic columns of different length (50 and 250 mm) were used to evaluate the effects of column length on gradient separation of protein digests. A tryptic digest of a 9-protein mixture was used as a test sample. Peak capacities were determined from selected extracted ion chromatograms, and tandem mass spectrometry data were used for database matching using the MASCOT search engine. Peak capacities and protein identification scores were higher for the long column with all gradients. Peak capacities appear to approach a plateau for longer gradient times; maximum peak capacity was estimated to be 294 for the short column and 370 for the long column. Analyses with similar gradient slope produced a ratio of the peak capacities of 3.36 for the long and the short column, which is slightly higher than the expected value of the square root of the column length ratio. The use of a longer monolith improves peptide separation, as reflected by higher peak capacity, and also increases protein identification, as observed from higher identification scores and a larger number of identified peptides. Attention has also been paid to the peak production rate (PPR, peak capacity per unit time). For short analysis times, the short column produces a higher PPR, while for analysis times longer than 40 min, the PPR of the 250-mm column is higher.  相似文献   

17.
Nowadays, there are new technologies in high-performance liquid chromatography columns available enabling faster and more efficient separations. In this work, we compared three different types of columns for the analysis of main soy isoflavones. The evaluated columns were a conventional reverse phase particle column, a fused-core particle column, and a monolithic column. The comparison was in terms of chromatographic parameters such as resolution, asymmetry, number of theoretical plates, variability of retention time, and peak width. The lower column pressure was provided by the monolithic column, although lower chromatographic performance was achieved. Conventional and fused-core particle columns presented similar pressure. Results also indicate that direct transfer between particle and monolithic columns is not possible requiring adjustment of conditions and a different method optimization strategy. The best chromatographic performance and separation speed were observed for the fused-core particle column. Also, the effect of sample solvent on the separation and peak shape was evaluated and indicated that monolithic column is the most affected especially when using higher concentrations of acetonitrile or ethanol. Sample solvent that showed the lowest effect on the chromatographic performance of the columns was methanol. Overall evaluation of methanol and acetonitrile as mobile phase for the separation of isoflavones indicated higher chromatographic performance of acetonitrile, although methanol may be an attractive alternative. Using acetonitrile as mobile phase resulted in faster, higher resolution, narrower, and more symmetric peaks than methanol with all columns. It also generated the lower column pressure and flatter pressure profile due to mobile phase changes, and therefore, it presents a higher potential to be explored for the development of faster separation methods.  相似文献   

18.
Explosives such as 2,4,6-trinitrotoluene (TNT), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) are widely distributed environmental contaminants. Complete chromatographic separation is necessary in order to accurately determine and quantify explosives and their degradation products in environmental samples and in (bio)transformation studies. The present study describes a RP-HPLC method with diode array detection using a LC-8 guard column, a Supelcosil LC-8 chromatographic column, and a gradient elution system. This gradient method is capable of baseline separating the most commonly observed explosives and TNT transformation metabolites including 2,4,6-triaminotoluene (TAT) in a single run. The TNT metabolites separated were 2-hydroxylamino-4,6-dinitrotoluene, 4-hydroxylamino-2,6-dinitrotoluene, 2,4-dihydroxylamino-6-nitrotoluene, 4,4',6,6'-tetranitro-2,2'-azoxytoluene, 2,2',6,6'-tetranitro-4,4'-azoxytoluene, 4,4',6,6'-tetranitro-2,2'-azotoluene, 2,2',6,6'-tetranitro-4,4'-azotoluene, 2-amino-4,6-dinitrotoluene, 4-amino-2, 6-dinitrotoluene, 2,6-diamino-4-nitrotoluene, 2,4-diamino-6-nitrotoluene, and TAT. The same gradient method at a different column temperature can also be used to baseline separate the explosives targeted in the Environmental Protection Agency (EPA) Method 8330 with approximately 22% reduction in total run time and 48% decrease in solvent consumption compared to previously published methods. Good separation was also obtained when all TNT metabolites and EPA Method 8330 compounds (a total of 23 compounds) were analyzed together; only 2,6-DANT and HMX co-eluted in this case. The influence of temperature (35-55 degrees C) and the use of an ion-pair reagent on the chromatographic resolution and retention were investigated. Temperature was identified as the key parameter for optimal baseline separation. Increased temperature resulted in shorter retention times and better peak resolution especially for the aminoaromatics investigated. The use of an ion-pair reagent (octanesulfonic acid) generally resulted in longer retention times for compounds containing amine functional groups, more baseline noise, and decreased peak resolution.  相似文献   

19.
李莉  李硕  王海燕  孙磊 《色谱》2022,40(2):190-197
以化妆品中23种防腐剂检测方法为例,探讨色谱柱选择对液相色谱方法测定结果的影响。参照《化妆品安全技术规范》甲基异噻唑啉酮等23个组分的检验方法,在2台不同的高效液相色谱仪上用15款不同品牌、型号的C18色谱柱检测23种防腐剂,计算色谱峰的理论塔板数和分离度,对23种组分的分离效果进行分析,并应用USP (United States Pharmacopeia)数据库和PQRI (Product Quality Research Institute)数据库等2种等效色谱柱选择方法,对不同色谱柱的分离效果及等效性进行评价和预测。实验结果表明,15款色谱柱对23种防腐剂的分离效果差异显著,仅有2款色谱柱可以实现23种组分的完全分离。USP和PQRI数据库中2种等效色谱柱选择方法均无法预测出合适的等效色谱柱,对23种防腐剂的液相色谱分析参考价值均较小。色谱柱是影响23种防腐剂液相色谱法测定结果准确性的关键因素,有关实验室在应用该方法时,应考虑色谱柱选择性差异。化妆品基质复杂,如何在现有研究成果的基础上,开发色谱柱的筛选和预测评价体系,进而指导实际样品的分离是下一步研究的重点、难点。建议有关部门在制修订检测方法时,注重色谱柱的耐用性考察,完善系统适应性指标,细化色谱柱分类和增加描述信息,指导色谱柱的合理选择,从而规避由于色谱柱使用过程中选择依据缺失而导致测定结果不准确的风险。  相似文献   

20.
秦昆明  方前波  蔡皓  李伟东  蔡宝昌 《色谱》2009,27(6):781-786
研究和建立了百合知母汤的高效液相色谱(HPLC)指纹图谱,为研究百合知母汤的药效物质基础及配伍变化提供了手段。采用Agela Venusil XBP-C18色谱柱(250 mm × 4.6 mm,5 μm),以乙腈和0.1%甲酸为流动相二元梯度洗脱,流速1 mL/min,检测波长315 nm,柱温25 ℃。以芒果苷为参照物,在相同的色谱条件下测定了10批不同产地的百合与知母制备的百合知母汤的指纹图谱,获得了16个共有指纹峰,通过与对照品的保留时间及紫外光谱比较,标定了5-羟甲基糠醛(5-HMF)、新芒果苷、芒果苷、异芒果苷、王百合苷B的出峰位置。该方法得到的百合知母汤的指纹图谱特征性和重现性较好,方法稳定、可靠,可以为百合知母汤的质量控制提供参考。通过实验归属了百合知母汤指纹图谱中的主要色谱峰,并确定了煎煮过程中的主要变化成分为5-HMF。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号