首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
张良英  Jin Guo-Xiang  曹力 《物理学报》2008,57(8):4706-4711
对单模激光增益模型的光强方程加入调频信号,用线性化近似方法计算了以δ函数形式关联的两白噪声驱动下光强的输出功率谱及信噪比. 结果表明,信噪比随抽运噪声和量子噪声强度的变化可出现典型随机共振,受调制信号振幅的影响,信噪比随载波信号频率和调制信号频率的变化出现抑制、单调上升、共振、抑制和共振等几种情况. 关键词: 抽运噪声 单模激光 随机共振 调频信号  相似文献   

2.
The problem of the relaxation of identical spins 1/2 induced by chemical exchange between spins with different chemical shifts in the presence of time-dependent RF irradiation (in the first rotating frame) is considered for the fast exchange regime. The solution for the time evolution under the chemical exchange Hamiltonian in the tilted doubly rotating frame (TDRF) is presented. Detailed derivation is specified to the case of a two-site chemical exchange system with complete randomization between jumps of the exchanging spins. The derived theory can be applied to describe the modulation of the chemical exchange relaxation rate constants when using a train of adiabatic pulses, such as the hyperbolic secant pulse. Theory presented is valid for quantification of the exchange-induced time-dependent rotating frame longitudinal T1rho,ex and transverse T2rho,ex relaxations in the fast chemical exchange regime.  相似文献   

3.
Kim J  Kärtner FX  Perrott MH 《Optics letters》2004,29(17):2076-2078
A synchronization scheme for extraction of low-jitter rf signals from optical pulse trains, which is robust against photodetector nonlinearities, is described. The scheme is based on a transfer of timing information into an intensity imbalance of the two output beams from a Sagnac loop. Sub-100-fs timing jitter between the extracted 2-GHz rf signal and the 100-MHz optical pulse train from a mode-locked Ti:sapphire laser is demonstrated.  相似文献   

4.

Objective

Fully automatic tissue characterization in intravascular ultrasound systems is still a challenge for the researchers. The present work aims to evaluate the feasibility of using the Higuchi fractal dimension of intravascular ultrasound radio frequency signals as a feature for tissue characterization.

Methods

Fractal dimension images are generated based on the radio frequency signals obtained using mechanically rotating 40 MHz intravascular ultrasound catheter (Atlantis SR Plus, Boston Scientific, USA) and compared with the corresponding correlation images.

Conclusion

An inverse relation between the fractal dimension images and the correlation images was revealed indicating that the hard or slow moving tissues in the correlation image usually have low fractal dimension and vice-versa. Thus, the present study suggests that fractal dimension images may be used as a feature for intravascular ultrasound tissue characterization and present better resolution then the correlation images.  相似文献   

5.
6.
This article discusses the detection of mixed modulation, i.e., simultaneous amplitude and frequency modulation (MM). The investigations have incorporated both a sine wave modulating signal and an irregular modulating signal, a very narrow noise band, of a specified center frequency. The results revealed that for a sinusoidal low-frequency modulating signal, amplitude and frequency changes that were separately subthreshold could be detected by listeners in mixed modulation. This indicates summation of sensations caused by simultaneous AM and FM modulation. This effect was not observed in the case of the irregular modulating signal. A hypothesis is advanced that the perception of modulated signals is governed by two mechanisms, viz., temporal and spectral. The operation of the two mechanisms depends mainly on the modulating frequency. The type of modulation does not play any significant role in this case.  相似文献   

7.
The generation of tissue harmonics is due to nonlinear nature of ultrasound wave propagation in biological tissues.The tissue harmonics for imaging i.e.tissue harmonic imaging (THI)uses higher frequency components for imaging in which the resolution improves significantly but signal-to-noise ratio(SNR)and penetration depth remains low as compared to both fundamental and second harmonic imaging.The coded excitations have potential to improve the SNR which ultimately leads to improved penetration depth.In the present work,the linear frequency modulated(chirp/LFM)and nonlinear frequency modulated(NLFM)signals have been used to investigate the nonlinear ultrasound wave propagation and harmonic generation in biological tissues.The SNR has been found to be substantially improved for coded tissue harmonic imaging(CTHI)as well as for coded superharmonic imaging(CSHI).  相似文献   

8.
9.
Radio frequency glow discharge optical emission spectroscopy (RF-GD-OES) is routinely used for the chemical analysis of solid samples. For quantification two independent electrical signals of the discharge are required. These are provided in real time by the glow discharge source with integrated voltage and current sensors. The available time-dependent voltage and current must be reduced. For this purpose a plasma equivalent circuit is used. It is shown that the cathode voltage and active cathode current describe the sputtering and excitation well. Measuring standard reference materials at constant cathode voltage and cathode current results in linear calibration curves.  相似文献   

10.
屠浙  彭皓  王飞  马洪 《物理学报》2013,62(3):30502-030502
研究了色噪声参激和周期调制噪声外激联合驱动的分数阶线性振子及其共振行为, 利用Laplace变换和Shapiro-Loginov公式, 推导出了系统响应的一阶矩及稳态响应振幅的解析表达式. 讨论了系统阶数、摩擦系数、周期驱动力频率、色噪声强度和相关率等参数对系统稳态响应的影响, 发现系统稳态响应振幅具有非单调变化的特点, 即出现了广义随机共振现象. 并且在适当参数下, 稳态响应振幅还存在具有双峰的广义随机共振现象.  相似文献   

11.
12.
13.
Tamed frequency modulation (TFM) is a spectrally efficient constant amplitude continuous phase modulation (CPM) scheme which can be simply realized by using a frequency modulator (FM). In the implementation the modulation index of TFM is calibrated to have a nominal value of 0.5, but due to temperature variations it can drift causing time varying phase jitter. In this paper we present novel algorithms and performance results to measure and control the modulation index in a coherent receiver based on the joint reduced state sequence detector (RSSD) and per-survivor processing (PSP) carrier phase estimation. The modulation index estimator measures phase transitions in the receiver and derives estimates by comparing the result to the coding rule of the TFM signal. The estimator has acquisition and tracking ability, and the current estimate can be used to replace the nominal index value. Our simulation results show that the proposed coherent receiver with the novel modulation index estimator has less than 1 dB performance degradation compared to around 4.5 dB exploiting only the PSP carrier phase estimation.  相似文献   

14.
We study the phase characteristics of echo signals during vertical acoustic sounding of a water medium with narrowly directed emission. We experimentally demonstrate the possibility of measuring the dependence of the phase of echo signals on the delay for a probe signal with linear frequency modulation. We substantiate the possibility of remote determination of sound velocity variations in water.  相似文献   

15.
16.
调制无线电信号的分形特征研究   总被引:1,自引:0,他引:1       下载免费PDF全文
唐智灵  杨小牛  李建东 《物理学报》2011,60(5):56401-056401
调制方式的不同以及信号受到功率放大器的非线性变换决定了调制无线电信号的形状存在着差异,提取这些差异特征是信号识别的基础. 基于分形理论提取信号特征是一种新的方法,本文模拟了在不同信噪比条件下,通过计算调制无线电信号的方差分形维以及Mandelbrot奇异分形维谱,将信号的调制特征以及非线性变换特征投射到分形特征空间. 数值仿真结果表明,不同调制方式、非线性变换对应了分形特征空间中的不同位置. 这些结果表明分形理论能够有效提取无线电信号的调制特征以及功率放大器的特征,对信号的调制方式以及个体特征识别具有一定 关键词: 无线电 信号 分形特征 识别  相似文献   

17.
We propose and demonstrate a technique for electrical detection of polarized spins in semiconductors in zero applied magnetic fields. Spin polarization is generated by optical injection using circularly polarized light which is modulated rapidly using an electro-optic cell. The modulated spin polarization generates a weak time-varying magnetic field which is detected by a sensitive radio-frequency coil. Using a calibrated pickup coil and amplification electronics, clear signals were obtained for bulk GaAs and Ge samples from which an optical spin orientation efficiency of 4.8% could be determined for Ge at 1342 nm excitation wavelength. In the presence of a small external magnetic field, the signal decayed according to the Hanle effect, from which a spin lifetime of 4.6±1.0 ns for electrons in bulk Ge at 127 K was extracted.  相似文献   

18.
19.
20.
The authors examine the synchronization of signals with complex modulation generated by a system of two mutually coupled self-excited oscillators each of which has frequency-control feedback.Nizhny Novgorod State University. Translated from Izvestiya Vysshikh Uchebnykh Zavedenii, Radiofizika, Vol. 36, No. 8, pp. 808–810, August, 1993.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号