首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed for the determination of basal acetylcholine (ACh) in microdialysate from the striatum of freely moving rats. A microdialysis probe was surgically implanted into the striatum of the rats and Ringer's solution was used as the perfusion medium at a flow rate of 2 microL per minute. The samples were then analyzed off-line by LC/MS/MS experiments. The separation of ACh and choline (Ch) was carried out using reverse phase ion pair liquid chromatography with heptafluorobutyric acid as a volatile ion pairing reagent. Analytes were detected by electrospray ionization tandem mass spectrometry in the positive ion mode. The detection limit for ACh was 1.4 fmol on column, which is at least three times lower than previously reported. Three quaternary ammonium compounds in the rat brain microdialysate were also identified by tandem mass spectrometry experiments in which the unknown mass spectra were compared with standard reference compounds. These compounds were identified as carnitine, acetylcarnitine and (3-carboxypropyl)trimethylammonium. This is the first known report of the compound (3-carboxypropyl)trimethylammonium being found in rat brain.  相似文献   

2.
A sensitive liquid chromatography/electrospray ionisation tandem mass spectrometric (LC/ESI-MS/MS) method was developed for the analysis of acetylcholine and choline in microdialysis samples. A Ringer's solution that contains high (150 mM) concentrations of inorganic salts was used to extract acetylcholine and choline from a rat or mouse brain. The separation of acetylcholine, choline, an internal standard acetyl-beta-methylcholine, endogenous compounds and inorganic cations was achieved with hydrophilic interaction chromatography using a diol column. The eluent consisted of 20 mM ammonium formate (pH 3.3) and acetonitrile (20:80) which is favourable for the ESI process. Limits of detection (signal-to-noise (S/N) ratio = 3) of 0.02 nM (0.2 fmol) for acetylcholine and 1 nM (10 fmol) for choline were observed using standards diluted in Ringer's solution. A good linearity was obtained from the limit of quantitation: 0.1 nM (S/N ratio = 10) to 50 nM (r = 0.999) for acetylcholine and within the concentration range of 100-3500 nM (r = 0.998) for choline. The between-day repeatability of the method was good; RSD was 3.1% at 1 nM level of acetylcholine and 3.5% at 1000 nM level of choline. The recoveries for addition of 1 or 2.5 nM acetylcholine and 0.2 or 1 microM choline in microdialysis balancing samples were between 93 and 101% indicating that no suppressing endogenous compounds were co-eluting with acetylcholine or choline. The developed method was applied to the analysis of microdialysis balancing samples collected from rat and mouse brains.  相似文献   

3.
An ion-pairing liquid chromatography/electrospray tandem mass spectrometry (LC/ES-MS/MS) method with in vivo microdialysis for the determination of amphetamine in rat brain has been developed. A microdialysis probe was surgically implanted into the striatum of the rat and artificial cerebrospinal fluid (aCSF) was used as the perfusion medium. Samples were collected and then analyzed off-line by LC/ES-MS/MS. A reversed-phase C18 column was employed for LC separation and MS/MS was utilized for detection. Trifluoroacetic acid (TFA) was added to the mobile phase (acetonitrile/water) as an ion-pairing reagent. Detection was by ES-MS/MS directly, and no post-column addition of organic modifier was needed. Dual linear ranges were determined from 0.1-0.5 microg/mL and 0.005-0.1 microg/mL, respectively. The detection limit, based on a signal-to-noise ratio of 3, was 0.001 microg/mL (5 nM). Good precision and accuracy were obtained. The applicability of this newly developed method was demonstrated by continuous monitoring of amphetamine concentrations in rat brain. Amphetamine reached a maximum concentration of 0.086 +/- 0.017 microg/mL over 20-40 min after a single 3.0 mg/kg intraperitoneal administration.  相似文献   

4.
A sensitive and simultaneous liquid chromatographic-mass spectrometric (LC/MS) method for the determination of current four HIV protease inhibitors (PIs), indinavir (IDV), saquinavir (SQV), nelfinavir (NFV) and amprenavir (APV) in rat plasma and liver dialysate by a microdialysis method was described. An isocratic LC/MS method in combination with atmospheric pressure chemical ionization was developed for the determination of these four PIs in biological samples in the same run. The analytes including an internal standard were extracted from 100 microL of plasma or 150 microL of liver dialysate samples by salting-out with 100 microL of ice-cold 2 M K(3)PO(4) followed by ether extraction. The separation of analytes was carried out on a reversed-phase semi-micro column using 50% of acetonitrile containing 1% acetic acid as mobile phase at a flow rate of 0.2mL/min(-1). The separation was completed within 5 min. Precision, recovery and limits of detection indicated that the method was suitable for the quantitative determination of these PIs in rat plasma or liver dialysate. This simple, sensitive and highly specific LC/MS method is suitable for pharmacokinetic studies and therapeutic drug monitoring in AIDS patients who receive double protease therapy.  相似文献   

5.
A high-throughput liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) assay using automated sample preparation has been developed for the determination of valproic acid (VPA) in mouse plasma. A liquid-handling system was programmed to prepare calibration standard solutions in plasma, as well as quality controls and clinical samples. Plasma protein precipitation was performed on a 96-well plate, and the collected supernatant was directly injected into a reversed-phase LC/ESI-MS/MS system in the negative ionization mode. The calibration curve for VPA was linear over a dynamic range of 0.15-100 microg/mL. The limit of detection was 75 ng/mL and the lower limit of quantitation was 150 ng/mL. Intra- and inter-day validation assays of the semi-automated plasma analysis showed satisfactory accuracy and precision.  相似文献   

6.
Atmospheric pressure photoionization (APPI) is a novel method of ionization in liquid chromatography/mass spectrometry (LC/MS). It was originally developed in order to broaden the range of LC/MS ionizable compounds towards less polar compounds that cannot be analyzed by electrospray (ESI) and atmospheric pressure chemical ionization (APCI). Studies done thus far have shown that non-polar compounds that earlier were not ionizable in LC/MS can indeed be ionized by the use of APPI. However, the best ionization efficiency for low polarity samples has been achieved with low proton affinity (PA) solvents that are not suitable in reversed-phase LC (RP-LC). Here it is demonstrated that the signals for analytes with low proton affinities in acetonitrile can be increased 100-fold by using anisole as the dopant for APPI, which takes the sensitivity to the same level achieved in the analysis of high PA analytes.  相似文献   

7.
A simple, sensitive and selective liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometric method (LC/APCI-MS/MS) was developed and applied to quantitative determination of uptake of cholesterol by Caco-2 human intestine cells. Caco-2 cells were cultured in medium containing cholesterol-3,4-13C2 and phytosterols from nutritional supplements after in vitro digestion. Cellular cholesterol (cholesterol-3,4-13C2) and endogenous cholesterol were extracted using methanol/chloroform (1:2, v/v) and directly analyzed using LC/APCI-MS/MS with selected reaction monitoring (SRM), using cholesterol-2,2,3,4,4,6-d6 as an internal standard. Detection and quantification limits were 2.2 and 7.2 pmol, respectively. This method provides an effective tool for rapid determination of cholesterol uptake by cells with increased selectivity and sensitivity in comparison to previously reported LC/APCI-MS analysis using selected ion monitoring (SIM).  相似文献   

8.
1 Introduction Gaschromatography/massspectrometry (GC/MS)andliquidchromatography/massspectrometry (LC/MS) ,representativesofthehyphenatedtechniques ,aresomeofthemostreliableanalyticalmethods ,whicharethesynergisticcombinationoftwopowerfulanalyticaltechniques;…  相似文献   

9.
Desorption/ionization on silicon with time-of-flight mass spectrometry (DIOS-TOFMS) was employed for rapid quantification of small molecules and the measurement of critical constants used in enzyme kinetics studies. The approach was used to determine the Michaelis constant (Km) for acetylcholine esterase and the 50% inhibition constant (IC50) for tacrine. The Km was determined from a Lineweaver-Burk plot to be 98 microM. The IC50 was determined by assaying acetylcholine esterase activity with a range of tacrine concentrations, and measuring the amount of choline produced at a fixed time point by either DIOS-TOFMS or by liquid chromatography tandem mass spectrometry (LC/MS/MS). DIOS-TOFMS indicated an IC50 of 32.0 nM while LC/MS/MS gave a value of 31.8 nM. The excellent correlation with the reported IC50 values, ranging from 30.0 to 50.0 nM, and equivalence with the LC/MS/MS results, confirms that the DIOS-TOFMS method can be used for rapid and specific quantification of enzyme-inhibition assays.  相似文献   

10.
A semi-automated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of glimepiride in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Glimepiride and the internal standard (IS) glibenclamide were extracted from human plasma by LLE, using a mixture of ethyl acetate/diethyl ether 50:50 (v/v) as the organic solvent. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analyte and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by reversed-phase LC/MS/MS with positive ion electrospray ionization, using multiple reaction monitoring. The method proved to be sensitive and specific for both drugs, and statistical evaluation revealed excellent linearity for the range of concentrations 2.0-500.0 ng/mL with very good accuracy and inter- and intra-day precisions. The proposed method enabled the rapid and reliable determination of glimepiride in pharmacokinetic or bioequivalence studies after per os administration of a 3 or 4 mg tablet of glimepiride.  相似文献   

11.
Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.  相似文献   

12.
A new method based on matrix solid-phase dispersion (MSPD) on-line with a solid-phase extraction (SPE) cleanup process followed by liquid chromatography with tandem mass spectrometry (LC/MS/MS) is presented for the determination of 3 macrocyclic lactone mycotoxins in fish tissues: zearalenone, alpha-zearalenol, and beta-zearalenol. The sample was prepared in a device that used a reversed-phase material (C18) or a normal-phase material (neutral alumina) as a matrix dispersing agent, and a graphitized carbon black cartridge was used for sequential cleanup by SPE. LC/MS/MS was used for selective determination. Isocratic elution with acetonitrile-methanol-water was used for LC separation; for MS/MS, 2 types of interfaces (a pneumatically assisted electrospray ionization interface or an atmospheric pressure chemical ionization interface) were evaluated and compared in terms of the intensity of the total ion current produced by each analyte. The use of highly selective MSPD on-line with SPE for sample preparation before analysis allowed the removal of interfering matrix compounds present in tissue extracts that would otherwise cause severe ionization suppression of zearalenone and its metabolites during the ionization process. Average recoveries at 100 ng/g were between 83 and 103% with C18 and > or = 67% with neutral alumina; the relative standard deviations were < 11% with C18 and < 18% with alumina. The limits of detection ranged from 0.1 to 1.0 ng/g. Sample preparation is simple to perform, no special technical equipment is required, and solvent volumes are minimal.  相似文献   

13.
 Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, some compounds do not show enough sensitivity in LC/MS and soft ionization methods commonly used in LC/MS, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), sometimes do not give satisfactory structural information This report presents an overview  相似文献   

14.
An analytical procedure that enables routine analysis for trace determination of six anabolic macrocyclic lactones (zearalenone, alpha- and beta-zearalenol, zearalanone, zeranol, and taleranol) in sewage treatment plant (STP) samples has been developed. The method uses solid-phase extraction, followed by high-performance liquid chromatography with on-line tandem mass spectrometry using atmospheric pressure chemical ionization (LC/APCI-MS/MS). The extraction of these compounds from filtered water samples was performed off-line with C(18) solid-phase cartridges. The detection was achieved by isocratic reversed-phase high-performance liquid chromatography coupled with an heated nebulizer (HN) APCI interface operating in negative ion mode. Mean recovery of the analytes in STP effluent samples generally exceeded 81%. This method was used to determine the occurrence of target analytes in the aquatic environment. In the selected STP effluent samples, zearalenone and alpha-zearalenol were detected in the ng/L range.  相似文献   

15.
Three cholestane glycosides including OSW-1 with antitumor activity and two new analogues with modified steroidal side chains, thienyl OSW-1 and silylated thienyl OSW-1, were synthesized. Analyses were performed using optimized, reversed-phase liquid chromatography (LC) with electrospray ionization and atmospheric pressure chemical ionization quadrupole mass spectrometry (MS). The ionization mode and polarity, cone voltage, and chromatographic conditions were evaluated. The optimum LC/MS conditions to obtain valuable ions, indispensable for identifying the structures, are described. The key fragmentation pathways, which will be useful for confirming the detailed structures of steroidal glycosides, are also proposed.  相似文献   

16.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

18.
A sensitive and selective method for the determination of long-acting released octreotide in human plasma has been developed based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Octreotide and the internal standard, triptorelin, were precipitated from the matrix, washed with dichloromethane and subsequently separated by reversed-phase high-performance liquid chromatography (HPLC) employing a 1% formic acid/methanol gradient system. Detection was by electrospray ionization mass spectrometry in the positive ion mode using multiple-reaction monitoring. The assay was linear in the concentration range 0.0500-50.0 ng/mL with intra- and inter-day precision (as relative standard deviation) of <2.95% and <8.37%, respectively. The limit of detection was 0.0200 ng/mL. The method was applied to a pharmacokinetic study of long-acting released octreotide in healthy volunteers given an intramuscular injection containing 20 mg octreotide.  相似文献   

19.
There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed-phase chromatography. Normal-phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI- and APCI-MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non-esterified bioactive lipids are present. The use of electron capture APCI-MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal-phase chiral chromatography and electron capture APCI-MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non-selective lipoxygenase inhibitor to be assessed.  相似文献   

20.
A selective reversed-phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of azithromycin impurities and related substances in commercial azithromycin samples. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an atmospheric pressure chemical ionization interface operated in positive ion mode. The LCQ provides on-line LC/MS(n) capability, making it ideally suited for identification purposes. In comparison with UV detection, this hyphenated technique provides as its main advantage efficient identification of novel substances without time-consuming isolation and purification procedures. Using this technique, six novel related substances detected in commercial azithromycin samples have been studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号