共查询到16条相似文献,搜索用时 46 毫秒
1.
通过分析非稳腔DF化学激光器光腔内激光路径特性,指出非稳腔DF化学激光器输出光斑上下游光谱振荡路径不同导致输出光谱存在一定差异。试验测量了一台连续波DF化学激光器光斑上下游光谱,结果表明:非稳腔DF化学激光器光斑上下游光谱主要谱线成分未见显著差异;光斑上下游谱线相对强度存在一定差异;光斑上游各谱带相对强度最大值谱线转动量子数趋向于各谱带低转动量子数方向。根据实测光谱,对光斑上下游光谱所表征光腔温度和相对粒子数范围进行了估算,得到光腔上游平均温度要低于光腔下游平均温度。 相似文献
2.
对一台小型电激励连续波DF化学激光器进行了实验研究,在光轴位于喷管阵列出口平面下游10mm处和15mm处分别进行了出光实验,得到188.4W和205.8W的DF激光输出,输出激光波长为3.6~4.1μm,激光器的电效率分别为2.3%和2.5%。该小型电激励连续波DF化学激光器长时间(100s)运行的功率稳定性峰谷值和均方根值分别为±1.04%和0.49%,工作状态较为稳定,实验可重复性好,操作方便,是强光条件下镜片膜层吸收系数测量的适用红外激光光源。 相似文献
3.
4.
5.
6.
7.
8.
9.
10.
11.
Uday K. Sengupta Palash K. Das K. Narahari Rao 《Journal of Molecular Spectroscopy》1979,74(2):322-326
The six lowest states, dissociating into the and atomic states, are calculated using a nonempirical pseudopotential for the representation of the atomic cores and an extensive CI. The ground state is assigned as 3Π, but the 1Σ+ and 3Σ? minima are less than 0.5 eV higher. The results are compared with the few experimental data. 相似文献
12.
13.
I. A. Fedorov Yu. P. Maksimov N. E. Tret’yakov A. L. Étsina A. P. Zhevlakov 《Optics and Spectroscopy》2002,93(6):941-946
We experimentally studied the spectral parameters of the radiation generated by supersonic continuous-wave DF lasers with nozzle blocks of two different configurations (nozzle-nozzle and nozzle-radial-expansion-injector mixing schemes). We demonstrate the effects of the excess secondary-fuel (deuterium) ratio, the orientation of the optical cavity axis relative to the nozzle section, and gas-dynamical reactant mixing conditions on the spectral composition of the radiation. We show that the DF-laser spectrum can be controlled to a certain extent by varying these parameters. 相似文献
14.
M. Trautmann K. W. Rothe J. Wanner H. Walther 《Applied physics. B, Lasers and optics》1981,24(1):49-53
This paper describes a new method for the determination of the deuterium content in water samples. The absorption of the radiation
of a cw deuterium fluoride laser by HDO in water vapor is measured by means of a nonresonant spectrophone (optoacoustic detector).
This method enables one to evaluate the isotope ratio of hydrogen in a rather simple and straightforward way. Advantage is
taken of the fact that HDO absorbs some of the DF laser lines whereas H2O shows no absorption. Due to the small concentration in natural water deuterium is practically entirely present as HDO. Therefore
a selective determination of the deuterium content is possible. In the course of the investigation the absorption coefficients
of HDO for the different laser lines were determined. It was thereby established that there exists a strong coincidence of
an HDO absorption line with the 2P2 DF laser line. The detection sensitivity of the method was then examined for some selected laser lines. The concentration
of HDO in natural water samples could be determined with an accuracy of better than 10%. The experiments, however, show that
with appropriate improvements it should be possible to achieve an accuracy of better than 1%. This makes the method very interesting
as an analytical tool in hydrology. 相似文献
15.
16.
采用CLNST引入的扰流气注入技术对连续波氟化氘/氟化氢化学激光器进行数值模拟研究。模拟其3维流场有化学反应,但不考虑激射的情况。计算结果显示:加入扰流气后,平行注入的主副气流混合增强明显,气流混合速度明显加快,在喷管出口平面5 mm处即扩散至副喷管中心线位置,且小信号增益系数值明显增强。分析了流场结构得出:扰流气增强气流混合的主要方式在于使反应界面拉伸和扭曲,同时观察到有弱漩涡产生,但沿气流方向较快耗散掉,对流场影响较小。 相似文献