首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
Mercury forms in contaminated environmental samples were studied by means of sequential extraction and thermal desorption from the solid phase. The sequential extraction procedure involved the following fractions: water soluble mercury, mercury extracted in acidic conditions, mercury bound to humic substances, elemental Hg and mercury bound to complexes, HgS, and residual mercury. In addition to sequential extraction, the distribution of mercury species as a function of soil particles size was studied. The thermal desorption method is based on the thermal decomposition or desorption of Hg compounds at different temperatures. The following four species were observed: Hg0, HgCl2, HgS and Hg(II) bound to humic acids. The Hg release curves from artificial soils and real samples were obtained and their applicability to the speciation analysis was considered.   相似文献   

2.
This paper describes a method for speciation of Hg associated with airborne particulate matter. This method uses a mini-sampler for sample collection and analysis, thermal desorption for separating Hg species, and inductively coupled plasma mass spectrometry (ICP–MS) for identification and quantification of Hg. Coal fly ash spiked with different Hg compounds (e.g. Hg0, HgCl2, HgO, and HgS) was used for qualitative calibration. A standard reference material with a certified value for Hg concentration was used to evaluate the method. When the temperature of the furnace was programmed at a linear rate of increase of 50° min–1, different Hg compounds could clearly be separated. Three airborne particulate matter samples were collected in parallel in Toronto, ON, Canada and analyzed using this method. Reproducible results were obtained and Hg0, HgCl2, HgO, and HgS species from these samples were detected.  相似文献   

3.
4.
Different sub-sampling procedures were applied for the determination of mercury species (as total mercury Hg, methylmercury MeHg+ and inorganic mercury Hg2+) in frozen fish meat. Analyses were carried out by two different techniques. After the sample material was pre-treated by microwave digestion, atomic fluorescence spectroscopy (AFS) was used for the determination of total Hg. Speciation analysis was performed according to the following procedure: dissolution of sample material in tetramethylammonium hydroxide (TMAH), derivatisation with sodium tetraethylborate (NaBEt4), extraction into isooctane and measurement with gas chromatography inductively coupled plasma mass spectrometry (GC-ICPMS) for the identification and quantification of methylmercury (MeHg+) and inorganic mercury (Hg2+). The concentration range of total Hg measured in the shark fillets is between 0.9 and 3.6 g g–1 thawed out shark fillet. Speciation analysis leads to 94% Hg present as MeHg+. Homogeneity, storage conditions and stability of analytical species and sample materials have great influence on analytical results. Sub-sampling of half-frozen/partly thawed out fish and analysis lead to significantly different concentrations, which are on average a factor of two lower.  相似文献   

5.
A rapid and efficient closed vessel microwave-assisted extraction (MAE) method based on acidic leaching was developed and optimized for the extraction of total mercury (Hg), inorganic mercury (Hg2+) and methylmercury (CH3Hg+) from fish tissues. The quantitative extraction of total Hg and mercury species from biological samples was achieved by using 5 mol L−1 HCl and 0.25 mol L−1 NaCl during 10 min at 60 °C. Total Hg content was determined using inductively coupled plasma mass spectrometry (ICP-MS). Mercury species were measured by liquid chromatography hyphenated with inductively coupled plasma mass spectrometry (LC-ICP-MS). The method was validated using biological certified reference materials ERM-CE464, DOLT-3, and NIST SRM-1946. The analytical results were in good agreement with the certified reference values of total Hg and CH3Hg+ at a 95% confidence level. Further, accuracy validation using speciated isotope-dilution mass spectrometry (SIDMS, as described in the EPA Method 6800) was carried out. SIDMS was also applied to study and correct for unwanted species transformation reactions during and/or after sample preparation steps. For the studied reference materials, no statistically significant transformation between mercury species was observed during the extraction and determination procedures. The proposed method was successfully applied to fish tissues with good agreement between SIDMS results and external calibration (EC) results. Interspecies transformations in fish tissues were slightly higher than certified reference materials due to differences in matrix composition. Depending on the type of fish tissue, up to 10.24% of Hg2+ was methylated and up to 1.75% of CH3Hg+ was demethylated to Hg2+.  相似文献   

6.
The cloud point extraction (CPE) preconcentration of ultra-trace amount of mercury species prior to reverse-phase high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS) detection was studied. Mercury species including methyl-, ethyl-, phenyl- and inorganic mercury were transformed into hydrophobic chelates by reaction with sodium diethyldithiocarbamate, and the hydrophobic chelates were extracted into a surfactant-rich phase of Triton X-114 upon heating in a water bath at 40 °C. Ethylmercury was found partially decomposed during the CPE process, and was not included in the developed method. Various experimental conditions affecting the CPE preconcentration, HPLC separation, and ICP-MS determination were optimized. Under the optimized conditions, detection limits of 13, 8 and 6 ng l−1 (as Hg) were achieved for MeHg+, PhHg+ and Hg2+, respectively. Seven determinations of a standard solution containing the three mercury species each at 0.5 ng ml−1 level produced relative standard deviations of 5.3, 2.3 and 4.4% for MeHg+, PhHg+ and Hg2+, respectively. The developed method was successfully applied for the determination of the three mercury species in environmental water samples and biological samples of human hair and ocean fish.  相似文献   

7.
A simple non-chromatographic method for the determination of mercury (Hg2+), methylmercury (MeHg+), dimethylmercury (Me2Hg), and phenylmercury (PhHg+) employing atomic fluorescence spectrometry (AFS) as detection technique was developed. Mercury species showed a particular behavior in the presence of several reagents. In a first stage SnCl2 was employed for Hg2+ determination; in a second step, [Hg2+ + PhHg+] concentration was determined using SnCl2 and UV radiation. MeHg+ decomposition was prevented adding 2-mercaptoethanol. In a third stage, [Hg2+ + PhHg+ + MeHg+] concentration was determined using K2S2O8. Finally, the four species were determined employing NaBH4. Reagents concentration and flow rates were optimized. The extraction technique of mercury species involved the use of 2-mercaptoethanol as ion-pair reagent. The limits of detection for Hg2+, PhHg+, MeHg+, and Me2Hg were 1, 40, 68, and 99 ng L−1 with a relative standard deviation of 1.5, 3.1, 4.7 and 5.8%, respectively. Calibration curve was linear with a correlation factor equal to 0.9995. The method was successfully applied to the determination of the mercury species in two Antarctic materials: IRMM 813 (Adamussium colbecki) and MURST-ISS-A2 (Antarctic Krill).  相似文献   

8.
Silver (Ag) and gold (Au) nanoparticles impregnated in nylon membrane filters have been proposed as a new solid phase for preconcentration of mercury from natural waters. Water samples were treated with KMnO4 to convert all mercury species to inorganic Hg2+ and this was followed by the reduction of Hg2+ with NaBH4 to elemental Hg0. The determination of Hg was carried out by thermal evaporation of mercury from membrane filters using Zeeman mercury analyzer RA–915+ (Lumex, Russia). This process does not involve any additional sample treatment and sharply reduces risk of samples contamination. The limit of detection (LOD) was found to be 0.04 ng (absolute mass). Relative LOD was 0.4 ng L−1 for 100 mL of water. The method was validated through the analysis of CRM NRCC Tort–2 (Lobster hepatopancreas) and the found value (0.30 ± 0.07 μg g−1) was in good agreement with the certified value (0.27 ± 0.06 μg g−1). High efficiency of Hg accumulation from aqueous phase to membrane filters can be attributed to a large surface area of nanoparticles.  相似文献   

9.
The Semtech Hg 2000 analyzer continuously monitors the Hg0 content in flue gas. An on-line measurement method of total gaseous mercury in flue gas developed in our laboratory is described, which uses the absorption cell of the Semtech Hg Analyzer connected to a converter that is located in a furnace heated up to 650?°C. The converter can be heated up to 800?°C by both the furnace and an extra heating of a Ni-Cr alloy heating wire. Both the absorption cell and the converter are made of quartz. All gaseous Hg2+ species in flue gas are thermally reduced to Hg0 by the converter and detected by the Semtech Hg 2000 analyzer. The thermal reduction efficiencies of different conversion materials, which were filled in the converter, such as quartz chips, granular MgO, Ni and CoO powder, were tested using different flue gas conditions. Studies have shown that HCl is the major factor to inhibit the thermal reduction of Hg2+ to Hg0, and in the converter and the absorption cell Hg0 will react readily with HCl to form HgCl2. Both MgO and Ni could be used in the converter to absorb HCl in the flue gas, but Ni has better absorption efficiency. By using an original Semtech and a modified one, both Hg0 and total gaseous Hg contents in flue gas could be monitored simultaneously and continuously.  相似文献   

10.
Mercury speciation analysis (inorganic mercury, Hg2+, methylmercury, CH3Hg+ and dimethylmercury, (CH3)2Hg) by gas chromatography (GC) coupled to atomic emission spectroscopy with microwave induced plasma as excitation source (MIP-AES), after ethylation of the sample and extraction of the derivatised species into an organic phase, has been optimised using factorial design, analysis of variance and MultiSimplex techniques. Standard conditions were used in the derivatisation step with sodium tetraethylborate (NaB(C2H5)4) and in the extraction step into hexane. Good separation of the species investigated and maximum sensitivity was achieved using an OV-1701 capillary column. The sensitivity was found to be maximum with an helium flow rate (make-up flow) of 100 ml min−1. Procedures for a correct cleaning of glass and plastic ware, as well as for the purification of reagents used throughout the analytical process, are also suggested in order to avoid unacceptably high blank signals. The effect that ageing of stock solutions used in calibrations has on the artefact formation of CH3Hg+ has been also investigated. Using the optimum conditions found, good quality calibration curves (R2>0.995) for the three mercury species were obtained. Absolute detection limits of 0.5, 3 and 15 pg of (CH3)2Hg, CH3Hg+ and Hg2+, respectively, were estimated. The repeatability of the analysis was found to be better than 5% (n=5) in relative standard deviation (R.S.D.) units. The optimised procedure for the speciation of mercury in standard samples is the first step in the development of a method for routine analysis of mercury species in aquatic environmental samples.  相似文献   

11.
A new phase of ‘organic-inorganic’ composite system, polypyrrole polyantimonic acid, prepared by mixing the inorganic precipitate of hydrated antimony oxide with organic conducting polymer i.e., polypyrrole, providing a novel granular form hybrid cation-exchanger suitable for column operation with better chemical and thermal stability, good ion-exchange capacity, reproducibility and selectivity for heavy metals. The physicochemical properties of this material were studied using elemental analyses, AAS, SEM, XRD, FTIR and simultaneous TGA-DTA studies. Ion-exchange capacity, pH-titrations, elution and distribution behavior were also carried out to characterize the material. Distribution studies revealed the cation-exchange material to be highly selective for Hg(II) and its selectivity was performed by achieving some important binary separations like Hg2+-Zn2+, Hg2+-Ni2+, Hg2+-Cu2+, Hg2+-Fe3+, Hg2+-Cd2+, Hg2+-Mg2+ etc. on its column. Using this electroactive composite material, a new heterogeneous precipitate based selective ion-sensitive membrane electrode was fabricated for the determination of Hg(II) ions in solutions. The membrane electrode is mechanically stable, with a quick response time, and can be operated within a wide pH range. The selectivity coefficients for different cations determined by mixed solution method were found to be less than unity The electrode was also found to be satisfactory in electrometric titrations.  相似文献   

12.
Transport of mercury species in aquatic media is strongly affected by sorption processes on both organic and inorganic particles, and such mass transfer reactions are governed by speciation of this contaminant in the environment. The present research investigates the uptake of inorganic HgII species by sorbent materials based on polysiloxane-immobilized amine or thiol ligands, with the goal to highlight the effect of speciation on the sorption processes. Mercury binding was studied as a function of pH and chloride concentration to cover a wide range of species, including some among the most widely encountered forms in natural medium (HgCl42−, HgCl3, HgCl2, Hg(OH)2). It was found on the one hand that all these species are liable to be removed from solution by strong binding to silica gels grafted with mercaptopropyl groups. On the other hand, the use of silica bearing aminopropyl moieties has led to the selective accumulation of anionic chloro-complexes of HgII in acidic medium in the presence of high chloride concentration and to the uptake of HgII hydroxide around neutral pH, while HgCl2 cannot be adsorbed on this material. The former reaction involves electrostatic interactions between HgCl42− or HgCl3 and the ammonium form of polysiloxane-immobilized amine ligands, and the latter is driven by complexation of HgII species to the unprotonated amine groups. The interest of electrochemistry at carbon paste electrodes modified with these adsorbents for characterizing the sorption processes was also described by applying the following sequence “voltammetric detection subsequent to open-circuit accumulation”. This approach allows the in situ determination of the amount of mercury in the organic-inorganic hybrid phase, as a function of speciation in solution and without significant modification in the solution-phase concentrations, so that the adsorption and ion-exchange isotherms can be obtained very easily and without requiring additional treatment of the solid material.  相似文献   

13.
Here we present a new method for sequential selective extractions (SSEs) for Hg in geological solids, validated with extensive quality assurance procedures. Mercury was separated into fractions which “make sense” biogeochemically, rather than being identified by specific compounds. Experiments elucidated the effects of extraction time, solids-to-liquid ratio, and alternate solvents in natural samples, reference materials, and pure compounds. Compounds tested included HgS (red and black), HgCl2, Hg0, Hg2Cl2, HgSe, HgO, Hg(II) adsorbed on goethite, Hg-humate, and gold amalgamated Hg. Based on these findings, a five-step sequence of extractions was established to separate the compounds into biogeochemically distinct categories. The fractions and leaching media were as follows: F1 (deionized water), F2 (0.01 M HCl+0.1 M CH3COOH), F3 (1 M KOH), F4 (12 M HNO3), and F5 (aqua regia). Method blanks and method detection limits (MDLs) of 0.1-5 ng/g were obtained for the various analytical fractions, depending on the reagent concentrations used. Precision ranged from 2 to 8% for the major fractions in a sample, but increased to 2-40% for fractions making up <5% of the total. Recovery of total Hg by the sum of species in reference materials showed that the accuracy of the method ranges from 90 to 105%. Methylation potential, determined by anoxic incubation sample aliquots with biologically active sediments, showed that inorganic Hg extracted in the F3 fraction is most strongly correlated with methylation potential. In most natural and sediment incubation samples, the majority of Hg present was found either in the F3 or F5 fractions.  相似文献   

14.
This work demonstrated the feasibility of mercury speciation analysis by anion exchange chromatographic separation with inductively coupled plasma mass spectrometry detection. For the first time, by complexing with the mobile phase containing 3-mercapto-1-propanesulfonate into negatively charged complexes, fast separation of inorganic mercury (Hg2+), monomethylmercury (MeHg), ethylmercury (EtHg) and phenylmercury (PhHg) was achieved within 5 min on a 12.5-mm strong anion exchange column. The detection limits for Hg2+, MeHg, EtHg and PhHg were 0.008, 0.024, 0.029 and 0.034 μg L−1, respectively. The relative standard deviations of peak height and peak area (5.0 μg L−1 for each Hg species) were all below 3%. The determined contents of Hg2+, MeHg and total Hg in a certified reference material of fish tissue by the proposed method were in good accordance with the certified values with satisfactory recoveries. The relative errors for determining MeHg and total mercury were −2.4% and −1.2%, respectively, with an acceptable range for spike recoveries of 94–101%. Mercury speciation in 11 fish samples were then analyzed after the pretreated procedure. The mercury contents in all fish samples analyzed were found compliant with the criteria of the National Standards of China.  相似文献   

15.
A simple and inexpensive laboratory-built flow injection vapor generation system coupled to atomic absorption spectrometry (FI-VG AAS) for inorganic and total mercury determination has been developed. It is based on the vapor generation of total mercury and a selective detection of Hg2 + or total mercury by varying the temperature of the measurement cell. Only the inorganic mercury is measured when the quartz cell is at room temperature, and when the cell is heated to 650 °C or higher the total Hg concentration is measured. The organic Hg concentration in the sample is calculated from the difference between the total Hg and Hg2 + concentrations. Parameters such as the type of acid (HCl or HNO3) and its concentration, reductant (NaBH4) concentration, carrier solution (HCl) flow rate, carrier gas flow rate, sample volume and quartz cell temperature, which influence FI-VG AAS system performance, were systematically investigated. The optimized conditions for Hg2 + and total Hg determinations were: 1.0 mol l 1 HCl as carrier solution, carrier flow rate of 3.5 ml min 1, 0.1% (m/v) NaBH4, reductant flow rate of 1.0 ml min 1 and carrier gas flow rate of 200 ml min 1. The relative standard deviation (RSD) is lower than 5.0% for a 1.0 μg l 1 Hg solution and the limit of quantification (LOQ, 10 s) is 55 ng g 1. Certified samples of dogfish muscle (DORM-1 and DORM-2) and non-certified fish samples were analyzed, using a 6.0 mol l 1 HCl solution for analyte extraction. The Hg2 + and CH3Hg+ concentrations found were in agreement with certified ones.  相似文献   

16.
A hyphenated method for mercury speciation analysis by the coupling of high performance liquid chromatography and inductively coupled plasma mass spectrometry with the online strong anion exchange column (SAX) preconcentration was developed. The Hg analytes (Hg+, MeHg, EtHg and Hg2+) were absorbed on the SAX column preconditioned with sodium 3-mercapto-1-propanesulfonate, and then rapidly eluted (less than 16 s) by 5 μL 3% (v/v) 2-mercaptoethanol. The enrichment factors of 1025 for Hg+, 1084 for MeHg, 1108 for EtHg and 1046 for Hg2+ were obtained using 6 mL sample in a 1.5-min enrichment procedure. Rapid separation of the four mercurial compounds was achieved within 5 min on a 50-mm C18 column using 0.5% (v/v) 2-mercaptoethanol as the mobile phase. The detection limits for Hg+, MeHg, EtHg and Hg2+ were 0.015, 0.010, 0.009 and 0.016 ng L−1, each, and the relative standard deviations of peak height and peak area (5 ng L−1 for each Hg species) were all below 5%. Mercury speciation in three freshwater, two drinking water and two seawater samples were then analyzed by the proposed method. MeHg and Hg2+ concentrations down to 0.14 and 0.56 ng L−1 were detected in the drinking waters.  相似文献   

17.
We have combined short-column ion chromatographic separation and on-line photocatalyst-assisted vapor generation (VG) techniques with inductively coupled plasma mass spectrometry to develop a simple and sensitive hyphenated method for the determination of aqueous Hg2+ and MeHg+ species. The separation of Hg2+ and MeHg+ was accomplished on a cation-exchange guard column using a glutathione (GSH)-containing eluent. To achieve optimal chromatographic separation and signal intensities, we investigated the influence of several of the operating parameters of the chromatographic and photocatalyst-assisted VG systems. Under the optimized conditions of VG process, the shortcomings of conventional SnCl2-based VG techniques for the vaporization of MeHg+ was overcome; comparing to the concentric nebulizer-ICP-MS system, the analytical sensitivity of ICP-MS toward the detection of Hg2+ and MeHg+ were also improved to 25- and 7-fold, respectively. With the use of our established HPLC–UV/nano-TiO2–ICP-MS system, the precision for each analyte, based on three replicate injections of 2 ng/mL samples of each species, was better than 15% RSD. This hyphenated method also provided excellent detection limits—0.1 and 0.03 ng/mL for Hg2+ and MeHg+, respectively. A series of validation experiments—analysis of the NIST 2672a Standard Urine Reference Material and other urine samples—confirmed further that our proposed method could be applied satisfactorily to the determination of inorganic Hg2+ and MeHg+ species in real samples.  相似文献   

18.
A novel method based on photo-induced chemical vapor generation (CVG) as interface to on-line coupled Hg-cysteine ion chromatograpy (IC) with atomic fluorescence spectrometry (AFS) was developed for rapid determination of methylmercury (MHg) in seafood. Separation of inorganic mercury (Hg2+) and methylmercury(CH3Hg+) was accomplished on a Hamilton PRP X-200 polymer-based exchange column with a mobile of 3% acetonitrile, 1% (w/w) L-cysteine and 20 mmol L− 1 pyridine and 160 mmol L− 1 formic acid, at pH 2.4 within 7 min. Once separated, both species are reduced by formic acid in mobile phase under UV radiation to convert Hg0 on-line, which is subsequently swept (by argon carrier gas) into an atomic fluorescence spectrometry (AFS) for measurement. Under the optimized experiment conditions, the detection limits (as Hg), based on three times the standard deviation of a standard solution, were found to be 0.1 ng mL− 1 for mercury and 0.08 ng mL− 1 for methylmercury, with an injection volume of 100 μL. The developed method was validated by determination of certified reference material DORM-2 and was further applied in determination of seafood samples.  相似文献   

19.
A simple and reliable method for Hg determination in fish samples has been developed. Lyophilised fish tissue samples were extracted in a 25% (w/v) tetramethylammonium hydroxide (TMAH) solution; the extracts were then analysed by FI-CVAFS. This method can be used to determine total and inorganic Hg, using the same FI manifold. For total Hg determination, a 0.1% (w/v) KMnO4 solution was added to the FI manifold at the sample zone, followed by the addition of a 0.5% (w/v) SnCl2 solution, whereas inorganic Hg was determined by adding a 0.1% (w/v) L-cysteine solution followed by a 1.0% (w/v) SnCl2 solution to the FI system. The organic fraction was determined as the difference between total and inorganic Hg. Sample preparation, reagent consumption and parameters that can influence the FI-CVAFS performance were also evaluated. The limit of detection for this method is 3.7 ng g?1 for total Hg and 4.3 ng g?1 for inorganic Hg. The relative standard deviation for a 1.0 µg L?1 CH3Hg standard solution (n = 20) was 1.1%, and 1.3% for a 1.0 µg L–1 Hg2+ standard solution (n = 20). Accuracy was assessed by the analysis of Certified Reference Material (dogfish: DORM-2, NRCC). Recoveries of 99.1% for total Hg and 93.9% inorganic Hg were obtained. Mercury losses were not observed when sample solutions were re-analysed after a seven day period of storage at 4°C.  相似文献   

20.
Mercury is a contaminant of global concern that is transported throughout the atmosphere as elemental mercury Hg0 and its oxidized forms HgI and HgII. The efficient gas‐phase photolysis of HgII and HgI has recently been reported. However, whether the photolysis of HgII leads to other stable HgII species, to HgI, or to Hg0 and its competition with thermal reactivity remain unknown. Herein, we show that all oxidized forms of mercury rapidly revert directly and indirectly to Hg0 by photolysis. Results are based on non‐adiabatic dynamics simulations, in which the photoproduct ratios were determined with maximum errors of 3%. We construct for the first time a complete quantitative mechanism of the photochemical and thermal conversion between atmospheric HgII, HgI, and Hg0 compounds. These results reveal new fundamental chemistry that has broad implications for the global atmospheric Hg cycle. Thus, photoreduction clearly competes with thermal oxidation, with Hg0 being the main photoproduct of HgII photolysis in the atmosphere, which significantly increases the lifetime of this metal in the environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号