首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effect of oxidation of anoxic sediment upon the extraction of 13 elements (Cd, Sn, Sb, Pb, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, As) using the optimised Community Bureau of Reference of the European Commission (BCR) sequential extraction procedure and a dilute acid partial extraction procedure (4 h, 1 mol L−1 HCl) was investigated. Elements commonly associated with the sulfidic phase, Cd, Cu, Pb, Zn and Fe exhibited the most significant changes under the BCR sequential extraction procedure. Cd, Cu, Zn, and to a lesser extent Pb, were redistributed into the weak acid extractable fraction upon oxidation of the anoxic sediment and Fe was redistributed into the reducible fraction as expected, but an increase was also observed in the residual Fe. For the HCl partial extraction, sediments with moderate acid volatile sulfide (AVS) levels (1-100 μmol g−1) showed no significant difference in element partitioning following oxidation, whilst sediments containing high AVS levels (>100 μmol g−1) were significantly different with elevated concentrations of Cu and Sn noted in the partial extract following oxidation of the sediment. Comparison of the labile metals released using the BCR sequential extraction procedure (ΣSteps 1-3) to labile metals extracted using the dilute HCl partial extraction showed that no method was consistently more aggressive than the other, with the HCl partial extraction extracting more Sn and Sb from the anoxic sediment than the BCR procedure, whilst the BCR procedure extracted more Cr, Co, Cu and As than the HCl extraction.  相似文献   

2.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

3.
A quadrupole inductively coupled plasma mass spectrometer (Q-ICP-MS) equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulization system (APEX-IR) was employed to determine 17 elements (Al, As, Ba, Cd, Co, Cr, Li, Mn, Mo, Ni, Pb, Sb, Se, Sn, Sr, V, and Zr) in blood samples. Ammonia (for Al, Cr, Mn, and V) and O2 (for As and Se) were used as reacting gases. Selection of the best flow rate of the gases and optimization of the quadrupole dynamic bandpass tuning parameter (RPq) were carried out, using digested blood diluted 1 + 9 with deionized water and spiked with 1 μg L−1 of Al, Cr, Mn, V and 5 μg L−1 of As and Se. Detection limits were determined in digested blood using the 3σ criterion. The desolvating system allowed a sufficient sensitivity to be achieved to determine elements at levels of ng L−1 without detriment of signal stability. The accuracy of the method was tested with the whole blood certified reference material (CRM), certified for Al, As, Cd, Co, Cr, Mn, Mo, Ni, Pb, Sb, Se, and V, and with indicative values for Ba, Li, Sn, Sr, and Zr. The addition calibration approach was chosen for analysis. In order to confirm the DRC data, samples were also analyzed by means of sector field inductively coupled plasma mass spectrometry (SF-ICP-MS), operating in medium (mm = 4000) and high (mm = 10,000) resolution mode and achieving a good agreement between the two techniques.  相似文献   

4.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample.  相似文献   

5.
The BCR (the Community Bureau of Reference) of the European Union sequential extraction scheme for metal partitioning in estuarine sediments has been accelerated by using a matrix solid phase dispersion (MSPD) approach. The MSPD assisted BCR procedure consists of passing the extractants proposed by conventional BCR protocol (0.11 M acetic acid, 0.1 M hydroxylammonium chloride and 8.8 M hydrogen peroxide plus 1 M ammonium acetate) through the dispersed sample packaged inside a disposable syringe. Different silica-, magnesium- and aluminium-based materials were tested as dispersing agents and sea sand was found to offer the best performances. Variables for assisting the three stages of the BCR protocol were optimized, and accurate results were obtained when assisting the first and the third stages (exchangeable and oxidizable fractions, respectively). However, lack of accuracy was observed when assisting the second step (reducible fraction) and this result agrees with most of the assisted BCR procedures for which extracting the reducible fraction is the most troublesome stage. The organic matter oxidation (third stage) was successfully assisted by passing hydrogen peroxide at 50 °C through the dispersed sample inside de syringe just before passing ammonium acetate. Therefore, the time-consuming and unsafe conventional organic matter oxidation processes, commonly performed even for microwave/ultrasounds assisted BCR procedures, are totally avoided. Inductively coupled plasma-mass spectrometry (ICP-MS) was used as a selective detector. The target elements were Cd, Co, Cr, Mn, Ni, Sr and Zn (first stage), Cd, Co and Ni (second stage), and Co, Cr, Mn, Ni, Sr and Zn (third stage). Repeatability of the method (n = 7) was good, and RSDs values of 9, 10, 10, 8, 8, 3 and 8% was obtained for Cd, Co, Cr, Mn, Ni, Sr and Zn, respectively (first stage); 10, 9 and 9% for Cd, Co and Ni, respectively (second stage); and 6, 2, 3, 4, 7 and 9% Co, Cr, Mn, Ni, Sr and Zn, respectively (third stage). The procedure was also validated by analysing two certified reference materials (CRM 601 and CRM 701). Good accuracy was obtained for the target elements extracted at the first stage: Cd (4.0 ± 0.1 and 7.3 ± 0.09 μg g−1 in CRM 601 and CRM 701, respectively), Cr (0.36 ± 0.008 and 2.21 ± 0.08 μg g−1 in CRM 601 and CRM 701, respectively), Ni (8.0 ± 0.3 and 15.4 ± 0.3 μg g−1 in CRM 601 and CRM 701, respectively) and Zn (262 ± 3 and 203 ± 3 μg g−1 in CRM 601 and CRM 701, respectively). Also, good accuracy was observed for elements extracted at the third step: Cd (1.8 ± 0.09 and 0.29 ± 0.03 μg g−1 in CRM 601 and CRM 701, respectively), Cr (145 ± 4 μg g−1 in CRM 701), Ni (8.2 ± 0.7 and 15.1 ± 0.5 μg g−1 in CRM 601 and CRM 701, respectively) and Zn (45 ± 0.7 μg g−1 in CRM 701).  相似文献   

6.
A chelate resin immobilizing carboxymethylated pentaethylenehexamine (CM-PEHA resin) was prepared, and the potential for the separation and preconcentration of trace elements in water samples was evaluated through the adsorption/elution test for 62 elements. The CM-PEHA resin could quantitatively recover various elements, including Ag, Cd, Co, Cu, Fe, Ni, Pb, Ti, U, and Zn, and rare earth elements over a wide pH range, and also Mn at pH above 5 and V and Mo at pH below 7. This resin could also effectively remove major elements, such as alkali and alkaline earth elements, under acidic and neutral conditions. Solid phase extraction using the CM-PEHA resin was applicable to the determination of 10 trace elements, Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, V, and Zn, in certified reference materials (EnviroMAT EU-L-1 wastewater and ES-L-1 ground water) and treated wastewater and all elements except for Mn in surface seawater using inductively coupled plasma atomic emission spectrometry. The detection limits, defined as 3 times the standard deviation for the procedural blank using 500 mL of purified water (50-fold preconcentration, n = 8), ranged from 0.003 μg L−1 (Mn) to 0.28 μg L−1 (Zn) as the concentration in 500 mL of solution.  相似文献   

7.
The optimised BCR sequential extraction procedure and a 4 h 1 mol L−1 HCl partial extraction have been performed on the NIST 2711 reference material for a suite of 12 elements (Cd, Sb, Pb, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, As) using magnetic sector ICP-MS. A pseudo-total aqua regia digest of NIST 2711 has also been undertaken for quality assurance purposes, and comparison of the sum of the four BCR fractions, which included an aqua regia digest on the residue, with the pseudo-total aqua regia digest has been used to assess the accuracy of the BCR partitioning approach. As a result of this work, discrepancies between previous studies about BCR partitioning of elements in NIST 2711 have been discussed and an increase in confidence about the use of BCR partitioning scheme on seven elements (Cd, Pb, Al, Mn, Fe, Cu, Zn) in this standard material has been obtained. On the other hand, BCR partitioning for Sb, Cr, Co, Ni and As has been provided for the first time. Partial extraction results are also reported for the same 12 elements analysed by the optimised BCR procedure, with the partial extraction results exhibiting a strong correlation with the sum of the three labile steps of the BCR procedure.  相似文献   

8.
This present work reports the development and evaluation of a method for the direct determination of manganese in waters extracted during petroleum exploitation by Electrothermal Atomic Absorption Spectrometry (ET AAS) using Ir-W as permanent modifier. These waters, usually called produced waters, contain a wide range of organic and inorganic substances and are characterized by their high salinity. In order to achieve suitable experimental conditions for the method application, studies about the effect of operational variables (chemical modifier, pyrolysis and atomization temperatures) were performed, as well as the establishment of convenient calibration strategy. The best results were verified when the temperatures of pyrolysis and atomization were 1000 °C and 2300 °C, respectively, and using Ir-W as permanent modifier. The results showed that manganese can be determined by the standard addition method or employing external calibration with standard solutions prepared in the same salinity of the samples (with NaCl). Three real samples with salinities varying between 74 and 84‰ were successfully analyzed by the developed procedure. The limits of detection and quantification were 0.24 and 0.80 μg L−1, respectively, in purified water, and 0.34 and 1.1 μg L−1, respectively, in 0.4 mol L−1 NaCl medium (approximately 23‰ salinity).  相似文献   

9.
A method for the direct determination (without sample pre-digestion) of microelements in fruit juice by inductively coupled plasma optical emission spectrometry has been developed. The method has been optimized by a 23 factorial design, which evaluated the plasma conditions (nebulization gas flow rate, applied power, and sample flow rate). A 1:1 diluted juice sample with 2% HNO3 (Tetra Packed, peach flavor) and spiked with 0.5 mg L− 1 of Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Sn, and Zn was employed in the optimization. The results of the factorial design were evaluated by exploratory analysis (Hierarchical Cluster Analysis, HCA, and Principal Component Analysis, PCA) to determine the optimum analytical conditions for all elements. Central point condition differentiation (0.75 L min− 1, 1.3 kW, and 1.25 mL min− 1) was observed for both methods, Principal Component Analysis and Hierarchical Cluster Analysis, with higher analytical signal values, suggesting that these are the optimal analytical conditions. F and t-student tests were used to compare the slopes of the calibration curves for aqueous and matrix-matched standards. No significant differences were observed at 95% confidence level. The correlation coefficient was higher than 0.99 for all the elements evaluated. The limits of quantification were: Al 253, Cu 3.6, Fe 84, Mn 0.4, Zn 71, Ni 67, Cd 69, Pb 129, Sn 206, Cr 79, Co 24, and Ba 2.1 µg L− 1. The spiking experiments with fruit juice samples resulted in recoveries between 80 and 120%, except for Co and Sn. Al, Cd, Pb, Sn and Cr could not be quantified in any of the samples investigated. The method was applied to the determination of several elements in fruit juice samples commercialized in Brazil.  相似文献   

10.
A simple, rapid and efficient dispersive liquid–liquid microextraction based on the solidification of floating organic drop (DLLME–SFO) method, followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed for the simultaneous preconcentration and determination of heavy metals in water samples. One variable at a time method was applied to select the type of extraction and disperser solvents. Then, an orthogonal array design (OAD) with OA16 (45) matrix was employed to study the effects of different parameters on the extraction efficiency. Under the best experimental conditions (extraction solvent: 140 μL of 1-undecanol; disperser solvent: 2.0 mL of acetone; ligand to metal mole ratio: 20; pH: 6 and without salt addition), the enhancement factor ranged from 57 to 96. The calibration graphs were linear in the range of 0.5–250 μg L−1 for Mn, 1.25–250 μg L−1 for Cr, Co and Cu with correlation coefficient (r) better than 0.990. The detection limits were between 0.1 and 0.3 μg L−1. Finally, the developed method was successfully applied to extraction and determination of the mentioned metal ions in the tap, sea and mineral water samples and satisfactory results were obtained.  相似文献   

11.
Pedro R. Aranda 《Talanta》2008,77(2):663-666
Cloud point extraction (CPE) has been used for the preconcentration of cadmium, after the formation of a complex with 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (5-Br-PADAP), and further determination by graphite furnace atomic absorption spectrometry (ETAAS) using polyethyleneglicolmono-p-nonyphenylether (PONPE 7.5) as surfactant. The chemical variables that affect the cloud point extraction were optimized. The separation of the two phases was easily accomplished by cooling the mixture in order to make more viscous the surfactant-rich phase. In order to establish the optimum conditions for the determination of Cd by ETAAS, Pd + Mg, Pt, Ir, Rh and Ru were studied as chemical modifiers. The best thermal stabilization was obtained with Pd + Mg, with a maximum pyrolysis temperature of 1100 °C. Under the optimum conditions i.e., pH 9.0, [5-Br-PADAP] = 2.0 × 10−5 mol L−1, [PONPE 7.5] = 0.02% (w/v), an enhancement factor of 22-fold was reached. The lower limit of detection (LOD) obtained under the optimal conditions was 0.008 μg L−1. The precision for 10 replicate determinations at 0.2 μg L−1 Cd was 3.5% relative standard deviation (R.S.D.). The calibration graph using the preconcentration method was linear with a correlation coefficient of 0.9984 at levels close to the detection limit up to at least 1.0 μg L−1. The method was successfully applied to the determination of cadmium in urine samples and in a water standard reference material.  相似文献   

12.
Inductively coupled plasma optical emission spectrometers (ICP OES) allow fast simultaneous measurements of several spectral lines for multiple elements. The combination of signal intensities of two or more emission lines for each element may bring such advantages as improvement of the precision, the minimization of systematic errors caused by spectral interferences and matrix effects. In this work, signal intensities for several spectral lines were combined for the determination of Al, Cd, Co, Cr, Mn, Pb, and Zn in water. Afterwards, parameters for evaluation of the calibration model were calculated to select the combination of emission lines leading to the best accuracy (lowest values of PRESS–Predicted error sum of squares and RMSEP–Root means square error of prediction). Limits of detection (LOD) obtained using multiple lines were 7.1, 0.5, 4.4, 0.042, 3.3, 28 and 6.7 µg L− 1 (n = 10) for Al, Cd, Co, Cr, Mn, Pb and Zn, respectively, in the presence of concomitants. On the other hand, the LOD established for the most intense emission line were 16, 0.7, 8.4, 0.074, 23, 26 and 9.6 µg L− 1 (n = 10) for these same elements in the presence of concomitants. The accuracy of the developed procedure was demonstrated using water certified reference material. The use of multiple lines improved the sensitivity making feasible the determination of these analytes according to the target values required for the current environmental legislation for water samples and it was also demonstrated that measurements in multiple lines can also be employed as a tool to verify the accuracy of an analytical procedure in ICP OES.  相似文献   

13.
A new on-line cloud point extraction (CPE) system coupled to ICP-OES was designed for simultaneous extraction, preconcentration and determination of Cd2+, Co2+, Cr3+, Cu2+, Fe3+ and Mn2+ ions in water samples. This is based on the complexation of the metal ions with 1-(2-thenoyl)-3,3,3-trifluoraceton reagent (TTA) at pH 6.0 in the presence of non-ionic surfactant of Triton X-114. The micellar solution was heated above 60 °C and loaded through a column packed with cotton, which acts as a filter for retaining the analyte-entrapped surfactant-rich phase. Then the surfactant-rich phase was eluted using propanol:0.5 mol L−1 nitric acid solution (75:25, v/v) at a flow rate of 3.0 mL min−1 and directly introduced into the nebulizer of the ICP-OES. Several factors influencing the instrumental conditions and extraction were evaluated and optimized. Under the optimum conditions, the enhancement factors of the proposed method for target ions were between 42 and 97, the detection limits (DLs) were in the range of 0.1-2.2 μg L−1. The relative standard deviations (R.S.D.s) at 100 μg L−1 concentration levels of each ion were found to be less than 4.6%. Also, the calibration graphs were linear in the range of 0.5-100 μg L−1 with the correlation coefficients within the range of 0.9948-0.9994.Finally, the developed method was successfully applied to the extraction and determination of the mentioned metal ions in the tap, well, sea and mineral water samples and satisfactory results were obtained.  相似文献   

14.
Baytak S  Zereen F  Arslan Z 《Talanta》2011,84(2):319-323
A trace element preconcentration procedure is described utilizing a minicolumn of yeast (Yamadazyma spartinae) immobilized TiO2 nanoparticles for determination of Cr, Cu, Fe, Mn, Ni and Zn from water samples by inductively coupled plasma atomic emission spectrometry. The elements were quantitatively retained on the column between pH 6 and 8. Elution was made with 5% (v/v) HNO3 solution. Recoveries ranged from 98 ± 2 (Cr) to 100 ± 4 (Zn) for preconcentration of 50 mL multielement solution (50 μg L−1). The column made up of 100 mg sorbent (yeast immobilized TiO2 NP) offers a capacity to preconcentrate up to 500 mL of sample solution to achieve an enrichment factor of 250 with 2 mL of 5% (v/v) HNO3 eluent. The detection limits obtained from preconcentration of 50 mL blank solutions (5%, v/v, HNO3, n = 11) were 0.17, 0.45, 0.25, 0.15, 0.33 and 0.10 μg L−1 for Cr, Cu, Fe, Mn, Ni and Zn, respectively. Relative standard deviation (RSD) for five replicate analyses was better than 5%. The retention of the elements was not affected from up to 500 μg L−1 Na+ and K+ (as chlorides), 100 μg L−1 Ca2+ (as nitrate) and 50 μg L−1 Mg2+ (as sulfate). The method was validated by analysis of freshwater standard reference material (SRM 1643e) and applied to the determination of the elements from tap water and lake water samples.  相似文献   

15.
Sereshti H  Khojeh V  Samadi S 《Talanta》2011,83(3):885-890
In this study, dispersive liquid-liquid microextraction (DLLME) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed for simultaneous preconcentration and trace determination of chromium, copper, nickel and zinc in water samples. Sodium diethyldithiocarbamate (Na-DDTC), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters of DLLME such as volume of extraction and disperser solvents, pH, concentration of salt and concentration of the chelating agent were studied by a (2f−1) fractional factorial design to identify the most important parameters and their interactions. The results showed that concentration of salt and volume of disperser solvent had no effect on the extraction efficiency. In the next step, central composite design was used to obtain optimum levels of effective parameters. The optimal conditions were: volume of extraction solvent, 113 μL; concentration of the chelating agent, 540 mg L−1; and pH, 6.70. The linear dynamic range for Cu, Ni and Zn was 1-1000 μg L−1 and for Cr was 1-750 μg L−1. The correlation coefficient (R2) was higher than 0.993. The limits of detection were 0.23-0.55 μg L−1. The relative standard deviations (RSDs, C = 200 μg L−1, n = 7) were in the range of 2.1-3.8%. The method was successfully applied to determination of Cr, Cu, Ni and Zn in the real water samples and satisfactory relative recoveries (90-99%) were achieved.  相似文献   

16.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

17.
Zheng F  Hu B 《Talanta》2011,85(2):1166-1173
The poly(N-isopropylacrylamide) (PNIPA) gel is a widely studied thermo-responsive material that exhibits discontinuous change in volume when the external temperature is increased. In this paper, PNIPA gel was prepared and applied as a novel polymer coating for fiber-in-tube capillary microextraction of trace Co, Ni and Cd followed by on-line ICP-MS detection. The PNIPA coating was synthesized by using ethylene triethoxysilane (ETEOS) as the cross-linking agent under acidic conditions. This siloxane incorporated PNIPA gel achieves a dramatically rapid response rate when the external temperature is changed. The micro-structure of PNIPA coating was examined by scanning electron micrograph (SEM). Various experimental parameters including pH, temperature, sample flow rate and volume, elution solution and interfering ions affecting the extraction of the target analytes have been carefully investigated and optimized. Under the optimized conditions, the limits of detection were 0.45, 4.6 and 6.9 ng L−1 for Co, Ni and Cd, respectively. With a sampling frequency of 13 h−1, the relative standard deviations (RSDs) for Co, Ni and Cd were 4.8, 5.1 and 6.4% (C = 1 μg L−1, n = 7), respectively. The proposed method had been successfully applied to the determination of Co, Ni and Cd in human urine. To validate the proposed method, certified reference materials of NIES No. 10-b rice flour and GBW07601 (GSH-1) human hair were analyzed and the determined values were in a good agreement with the certified values. The PNIPA coated fiber-in-tube capillary can be reused for more than 150 times without decreasing the extraction efficiency.  相似文献   

18.
Solid phase extraction of metal ions using carbon nanotubes   总被引:1,自引:0,他引:1  
The sorption behaviour of carbon nanotubes (CNTs) toward some divalent metal ions such as Cu(II), Co(II), Ni(II), Zn(II), Pb(II), Mn(II) and Cd(II) has been investigated systematically. The affinity order of the metal ions towards CNTs at pH in the range of 7.0-9.0 was: Cu(II) > Pb(II) > Zn(II) > Co(II) > Ni(II) > Cd(II) > Mn(II). The experimental parameters for preconcentration of copper, which exhibits the highest affinity towards carbon nanotubes, on a microcolumn packed with CNTs prior to its determination by flame atomic absorption spectrometry have been investigated. Copper can be quantitatively retained at pH 8.2 from sample volume up to 150 mL and then eluted completely with 0.1 mol L− 1 HNO3. The limit of detection limit for Cu(II) determination with FAAS detection was 2.1 μg L− 1, and the RSD was 3.5% at the 50 μg L− 1 level. Under the optimal conditions for copper enrichment also Zn(II), Pb(II) and Ni(II) could be quantitatively preconcentrated from water samples. The method was validated using a certified reference materials BCR-610 and SRM 1640.  相似文献   

19.
The usefulness of the secondary line at 252.744 nm and the approach of side pixel registration were evaluated for the development of a method for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The influence of side pixel registration on the sensitivity and linearity was investigated by measuring at wings (248.325, 248.323, 248.321, 248.329, and 248.332 nm) of the main line for Fe at 248.327 nm. For the secondary line at 252.744 nm or side pixel registration at 248.325 nm, main lines for Cu (324.754 nm), Mn (279.482 nm) and Zn (213.875 nm), sample flow-rate of 5.0 mL min−1 and calibration by matrix matching, analytical curves in the 0.2-1.0 mg L−1 Cu, 1.0-20.0 mg L−1 Fe, 0.2-2.0 mg L−1 Mn, 0.1-1.0 mg L−1 Zn ranges were obtained with linear correlations better than 0.998. The proposed method was applied to seven soil samples and two soil reference materials (IAC 277; IAC 280). Results were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to soil extracts containing 0.15 and 0.30 mg L−1 Cu, 7.0 and 14 mg L−1 Fe, 0.60 and 1.20 mg L−1 Mn, 0.07 and 0.15 mg L−1 Zn, varied within the 94-99, 92-98, 93-101, and 93-103% intervals, respectively. The relative standard deviations (n = 12) were 2.7% (Cu), 1.4% (Fe - 252.744 nm), 5.7% (Fe - 248.325 nm), 3.2% (Mn) and 2.8% (Zn) for an extract containing 0.35 mg L−1 Cu, 14 mg L−1 Fe, 1.1 mg L−1 Mn and 0.12 mg L−1 Zn. Detection limits were 5.4 μg L−1 Cu, 55 μg L−1 Fe (252.744 nm), 147 μg L−1 Fe (248.325 nm), 3.0 μg L−1 Mn and 4.2 μg L−1 Zn.  相似文献   

20.
Zhong S  Tan SN  Ge L  Wang W  Chen J 《Talanta》2011,85(1):488-492
As a first attempt, cloud point extraction (CPE) was developed to preconcentrate bisphenol A (BPA), α-naphthol and β-naphthol prior to performing capillary zone electrophoresis (CZE) analysis. The parameters influencing the CPE efficiency, such as Triton X-114 concentrations, pH value, extraction time and temperature were systematically evaluated.After diluting with acetonitrile, the surfactant-rich phase of CPE can be injected directly into the CE instrument. The CZE baseline separation was achieved with running buffer (pH 9.5) composed of 50 mM sodium tetraborate in 30% (v/v) methanol, and an applied voltage of 25 kV. Under the optimized CPE and CZE conditions, an preconcentration factor of 50 times could be obtained and the limit of quantification for the three analytes were found to be 1.67 μg L−1, 0.80 μg L−1 and 0.67 μg L−1 for BPA, α-naphthol and β-naphthol, respectively. The proposed methods have shown to be a green, rapid and effective approach for determination of three analytes present in river water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号