首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Nanoliter high‐performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high‐performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high‐pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high‐performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high‐performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9–1.8 μg/L were obtained with precisions variable in the range of 1.6–4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87–102%).  相似文献   

2.
This study aimed to establish complementary high performance liquid chromatography (HPLC) methods including three modes of separation: ion pairing, cation exchange, and anion exchange chromatography, with detection by inductively coupled plasma mass spectrometry (ICPMS). The ion pairing mode enabled the separation of inorganic arsenate (As(V)), monomethylarsonic acid (MMA(V)), and dimethylarsinic acid (DMA(V)). However, the ion pair mode was unable to differentiate inorganic arsenite (As(III)) from arsenobetaine (AsB); instead, cation exchange chromatography was used to isolate and quantify AsB. Anion exchange chromatography was able to speciate all of the aforementioned arsenic species. Potential inaccurate quantification problem with urine sample containing elevated concentration of AsB, which eluted immediately after As(III) in anion exchange or ion pairing mode, was overcame by introducing a post-column hydride generation (HG) derivatization step. Incorporating HG between HPLC and ICPMS improved sensitivity and specificity by differentiating AsB from hydride-forming arsenic species. This paper emphasizes the usefulness of complementary chromatographic separations in combination with HG-ICPMS to quantitatively determine concentrations of As(III), DMA(V), MMA(V), As(V), and AsB in the sub-microgram per liter range in human urine.  相似文献   

3.
An analytical method for separation and determination of thallium species in water using high‐performance liquid chromatography with inductively coupled plasma mass spectrometry was developed. The composition and concentration of mobile phase, injection volume, and pH value were optimized respectively with an anion or cation exchange column. The results showed that Tl(I) and Tl(III) were effectively separated using anion exchange column Hamilton PRP‐X100, with the mobile phase consisting of 200 mmol/L ammonium acetate and 10 mmol/L diethylenetriaminepentaacetic acid (pH = 4.2). When using a Dionex cation exchange guard column, CS12A, 15 mmol/L HNO3, and 3 mmol/L diethylenetriaminepentaacetic acid as the mobile phase, Tl(I) and Tl(III) could be effectively separated. The detection limits of the methods were 3–6 and 9–12 ng/L, respectively. In a solution containing Fe ions and oxalic acid, a significant quantity of Tl(I) was oxidized. Fe ions and oxalic acid in the water samples did not interfere with high‐performance liquid chromatography‐inductively coupled plasma mass spectrometry measurement results.  相似文献   

4.
A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice.  相似文献   

5.
On‐line coupling of LC and ICP‐MS has been used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography provided better separation capability (both intra‐ and inter‐element) than size‐exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris–HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, enabling good chromatographic separation, and is acceptable for mass spectrometry too. The quantitative evaluation of element concentrations adhering to individual fractions was performed by the peak area normalization method. The repeatability of results ranged from 3 to 15% (depending on the element concentration level) and represented the main part of the result uncertainty. The accuracy of Cu and Zn fraction determinations was confirmed by comparison with the isotope dilution technique. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
There is an ongoing debate regarding the mechanism of Pt electrochemical dissolution. However, only off-line methods have so far been used, where separation of Pt species is performed separately from their detection. In this study, ion exchange chromatography coupled to inductively coupled plasma mass spectrometry was used for the first time to separate and detect Pt species generated by the electro-dissolution of a Pt electrode in 0.5 M aqueous H2SO4 solution. Because these species are either neutral or cationic, they were converted to chloro-complexes using 0.1 M KCl to enable their separation by anion exchange chromatography. Chloro-aqua complexes were observed in addition to the two predominant species, namely PtCl42− and PtCl62−. A good linear relationship was observed between the sum of peak areas for all complexes of a given Pt oxidation state and the Pt concentration, with a detection limit of 0.1 μg L−1 being reached for Pt(II) and Pt(IV). Application of this speciation analysis method to real samples generated by potential cycling using cyclic voltammetry (CV) revealed that, in general, at least 80% of Pt was present as Pt(II), irrespectively of the cyclic potential range or of temperature (up to 60 °C). Still, quantitative spike recovery was achieved after adding known amounts of Pt(II) or Pt(IV) to a sample prepared by CV, which demonstrated that no significant species inter-conversion took place.  相似文献   

7.
Chicken is the most consumed meat in North America. Concentrations of arsenic in chicken range from μg kg−1 to mg kg−1. However, little is known about the speciation of arsenic in chicken meat. The objective of this research was to develop a method enabling determination of arsenic species in chicken breast muscle. We report here enzyme-enhanced extraction of arsenic species from chicken meat, separation using anion exchange chromatography (HPLC), and simultaneous detection with both inductively coupled plasma mass spectrometry (ICPMS) and electrospray ionization tandem mass spectrometry (ESIMS). We compared the extraction of arsenic species using several proteolytic enzymes: bromelain, papain, pepsin, proteinase K, and trypsin. With the use of papain-assisted extraction, 10 arsenic species were extracted and detected, as compared to 8 detectable arsenic species in the water/methanol extract. The overall extraction efficiency was also improved using a combination of ultrasonication and papain digestion, as compared to the conventional water/methanol extraction. Detection limits were in the range of 1.0–1.8 μg arsenic per kg chicken breast meat (dry weight) for seven arsenic species: arsenobetaine (AsB), inorganic arsenite (AsIII), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), inorganic arsenate (AsV), 3-nitro-4-hydroxyphenylarsonic acid (Roxarsone), and N-acetyl-4-hydroxy-m-arsanilic acid (NAHAA). Analysis of breast meat samples from six chickens receiving feed containing Roxarsone showed the presence of (mean ± standard deviation μg kg−1) AsB (107 ± 4), AsIII (113 ± 7), AsV (7 ± 2), MMA (51 ± 5), DMA (64 ± 6), Roxarsone (18 ± 1), and four unidentified arsenic species (approximate concentration 1–10 μg kg−1).  相似文献   

8.
This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given.  相似文献   

9.
Wang B  Xie L  Lin Y  Yan Z  Wang L 《色谱》2011,29(3):223-227
建立了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用检测硒酸盐(SeVI)、亚硒酸盐(SeIV)、硒代蛋氨酸(SeMet)、硒代胱氨酸(SeCys2)和硒代乙硫氨酸(SeEt)的方法。采用Hamilton PRP X-100色谱柱(250 mm×4.6 mm, 5 μm),使用5 mmol/L的柠檬酸溶液(pH 4.5)作为流动相,电感耦合等离子体质谱(ICP-MS)检测,在21 min内可以完全分离5种硒形态。各形态硒的线性相关系数均大于0.9995, SeVI、SeIV、SeMet、SeCys2、SeEt的检出限分别为0.4、0.4、5.6、0.9、1.2 μg/L。探讨了不同提取方法的提取效果,鲜蘑菇和猪肉样品加标回收实验表明,对水溶性良好的无机硒和硒代蛋氨酸而言,采用柠檬酸溶液提取的效果非常好,SeIV和SeVI的回收率均在100%左右,SeMet的回收率为85.0%~95.3%;用蛋白酶水解提取,SeCys2和SeEt的回收率为79.9%~91.5%。该方法可完全满足食品中这5种硒形态的准确定量分析。  相似文献   

10.
Mercury and arsenic are two elements of undoubted importance owing to their toxic character. Although speciation of these elements has been developed separately, in this work for the first time the speciation of As and Hg using two atomic fluorescence detectors in a sequential ensemble is presented. A coupling based on the combination of high-performance liquid chromatography (where mercury and arsenic species are separated) and two atomic fluorescence detectors in series, with several online treatments, including photooxidation (UV) and hydride generation, has allowed the determination of mercury and arsenic compounds simultaneously. The detection limits for this device were 16, 3, 17, 12 and 8 ng mL–1 for AsIII, monomethylarsinic acid, AsV, Hg2+ and methylmercury, respectively. This coupling was compared with an analogous one based on inductively coupled plasma–mass spectrometry (ICP-MS) detection, with detection limits of 0.7, 0.5, 0.8, 0.9 and 1.1 ng mL–1, respectively. Multispeciation based on ICP-MS exhibits better sensitivity than the coupling based on tandem atomic fluorescence, but this second device is a very robust system and exhibits obvious advantages related to the low cost of acquisition and maintenance, as well as easy handling, which makes it a suitable system for routine laboratories.  相似文献   

11.
Yang G  Xu X  Wang W  Xu L  Chen G  Fu F 《Electrophoresis》2008,29(13):2862-2868
In this work, a novel and high-efficiency interface has been developed in coupling CE with inductively coupled plasma MS (ICPMS). The interface completely avoids laminar flow in CE capillary caused by the suction of nebulizer, and can be easily and stably operated at room temperature with high analyte transport efficiency to ICPMS. The new interface has a liquid dead volume smaller than 5 nL, which was much smaller than those (65-2500 microL) reported previously for other interfaces. All above features led to a higher sensitivity and a better electrophoretic resolution for CE-ICPMS coupled with this new interface. With the help of this new interface, we have successfully separated and determined five species of arsenic, As(III), As(V), monomethylarsonic acid, dimethylarsinic acid and p-aminophenylarsonic acid using CE-ICPMS within 11 min with a detection limit of 0.046-0.075 ng/mL and an RSD of 2-6% (n=6).  相似文献   

12.
为了准确测定茶叶中铬酸铅的含量,为市场监管提供判断依据,本文建立了微波灰化-高效液相色谱-电感耦合等离子体质谱仪测定茶叶中铬酸铅的方法。茶叶样品经微波灰化仪在500 ℃的条件下,灰化50 min后,用0.25 mol·L-1的NaOH和0.14 mol·L-1的Na2CO3混合碱性提取液在90 ℃-95 ℃温度下不间断搅拌提取10 min,提取液经色谱柱分离后,用ICP-MS测定52Cr。研究表明该方法在5.00 μg·L-1-500 μg·L-1范围内,线性良好,相关系数为0.9998,方法检出限低至2.5 mg·kg-1,三水平加标回收率为91.30 %~95.33 %,精密度在1.14 %~1.99 %之间。与电炉灼烧茶叶相比,微波灰化茶具有检出限低,精密度高,准确度良好等特性,能够满足茶叶中铬酸铅的测定。 关键词 微波灰化;高效液相色谱-电感耦合等离子体质谱法;铬酸铅;茶叶  相似文献   

13.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic (IC) detector for the speciation analysis of arsenic in edible oil. The arsenic species studied include arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine and arsenocholine. Gradient elution using (NH(4))(2)CO(3) and methanol at pH 8.5 allowed the chromatographic separation of all species in less than 8 min. Effluents from the IC column were delivered to the nebulizer of ICP-MS for the determination of arsenic. The concentrations of arsenic species have been determined in several used and fresh vegetable oil samples. In this study, a microwave-assisted extraction method was used for the extraction of arsenic species from oil samples. The extraction efficiency was better than 92% and the recoveries from spiked samples were in the range of 90-105%. The precision between sample replicates was better than 8% for all determinations. The limits of detection were in the range of 0.008-0.024 ng mL(-1) for various arsenic species based on peak height, which corresponded to 0.08-0.24 ng g(-1) in the original oil sample. The major arsenic species in the used oil samples varied based on the food items cooked.  相似文献   

14.
A “two‐step” pressurized microwave‐assisted extraction method coupled with ion chromatography with inductively coupled plasma mass spectrometry for the determination of different arsenic species in spirulina samples was developed. The extraction method used H2O2/H2O (1:5, v/v) as solvent to extract all arsenic species except arsenite, which was extracted by using water as solvent. The extraction method had a satisfactory recovery (>96%) and took a short time (20.0 min). With our method, all arsenic species in spirulina samples were completely separated and determined with recoveries of 84–105% and relative standard deviations of 2–4%. Food‐grade spirulina powder samples from seven provinces (Inner Mongolia, Zhejiang, Fujian, Hainan, Yunnan, Jiangsu, and Guangxi) in China were analyzed using the optimized protocol. Arsenate was detected at the concentration range of 170–394 ng/g in all the spirulina samples. Dimethylarsinic acid was detected at the concentration range of 32–839 ng/g in spirulina from above‐six provinces except Guangxi. Monomethylarsonic acid (67 ± 3 ng/g) was detected only in spirulina from Yunnan province. Arsenite was detected at the concentration range of 28–147 ng/g in spirulina from above five provinces except Hainan and Guangxi. Five unknown organic arsenic species were found in spirulina from above six provinces except Guangxi.  相似文献   

15.
Ion-pair reverse-phase HPLC-inductively coupled plasma (ICP) MS was employed to determine arsenite [As(III)], dimethyl arsenic acid (DMA), monomethyl arsenic (MMA) and arsenate [As(V)] in Chinese brake fern (Pteris vittata L.). The separation was performed on a reverse-phase C18 column (Haisil 100) by using a mobile phase containing 10 mM hexadecyltrimethyl ammonium bromide (CTAB) as ion-pairing reagent, 20 mM ammonium phosphate buffer and 2% methanol at pH 6.0. The detection limits of arsenic species with HPLC-ICP-MS were 0.5, 0.4, 0.3 and 1.8 ppb of arsenic for As(III), DMA, MMA, and As(V), respectively. MMA has been shown for the first time to experimentally convert to DMA in the Chinese brake fern, indicating that Chinese brake fern can convert MMA to DMA by methylation.  相似文献   

16.
Pang Y  Liu M  Liu S  Dong Z 《色谱》2011,29(10):1027-1030
建立了反相离子对色谱(RP-IPC)与电感耦合等离子体质谱(ICP-MS)联用技术快速分离测定化妆品中Cr(III)和Cr(VI)的方法。样品经乙二胺四乙酸钠盐(EDTA)50 ℃水浴中提取后,采用XDB-C18色谱柱分离,以5%(v/v)甲醇-2.0 mmol/L四正丁基铵盐(TBA)水溶液(pH 6.0)作为流动相,流速为1.0 mL/min,进样量为100 μL。采用碰撞池技术消除ICP-MS测定时40Ar12C+、35Cl16O1H+对52Cr+的光谱学干扰。Cr(III)和Cr(VI)的分离过程在5 min内完成。样品中加标量为0.01~0.50 μg时,其回收率为82.7%~107.2%,相对标准偏差(RSD)小于5.62%。该方法操作简便、灵敏度高、重现性好,适合于化妆品中Cr(III)和Cr(VI)的同时分析。  相似文献   

17.
赵云强  郑进平  杨明伟  付凤富 《色谱》2011,29(2):111-114
建立了一种利用毛细管电泳与电感耦合等离子体质谱联用技术(CE-ICP-MS)分析检测6种不同形态砷化合物的方法。详细研究了缓冲溶液的种类、pH值和浓度,分离电压以及进样时间等因素对6种砷化合物的分离度、灵敏度和重现性等的影响。结果表明,在最佳条件下,三价砷(As3+)、一甲基砷(MMA)、二甲基砷(DMA)、五价砷(As5+)、砷胆碱(AsC)和砷甜菜碱(AsB)6种化合物在25 min内得到完全分离。6次平行测定中,6种砷化合物峰面积的相对标准偏差(RSD)为3%~5%,检出限(以As计)(3倍信噪比)为0.08~0.12 μg/L。应用该方法成功地对海带中6种砷化合物进行了分析,回收率为90%~103%。该方法具有耗时短、灵敏度高、样品消耗量少、稳定性好等优点,可用于藻类样品中不同形态砷化合物的分析。  相似文献   

18.
Chemical speciation (extraction of elemental information and identification of molecular environment for an analyte in a complex sample) has been a long sought after goal for analytical chemists. Recently, because of successful developments in more sensitive element-specific detectors and gentle separation schemes, which preserve the true chemical information in a real sample, routine speciation experiments are becoming a common occurrence in the scientific literature. For many reasons, the combination of capillary electrophoresis (for separation of different chemical species) with inductively coupled plasma mass spectrometry (for element and isotope specific detection) has emerged as the method of choice for these analyses. In this article the basic principles of capillary electrophoresis inductively coupled plasma mass spectrometry are discussed. Design consideration for instrument interface, anticipated difficulties with speciation experiments and applications for specific matrices and analytes are also presented in this article.  相似文献   

19.
In this paper, carbon nanofibers (CNFs) as a novel solid phase extraction sorbent were developed for speciation preconcentration and separation of inorganic arsenic species As(III) and As(V) prior to determination by inductively coupled plasma mass spectrometry (ICP-MS). It was found that during all the steps of the separation, As(III) was selectively sorbed on the microcolumn packed with CNFs within a pH range of 1.0-3.0 in the presence of ammonium pyrroinedithiocarbamate (APDC), while As(V) was passed through the microcolumn without the retention. Various experimental parameters affecting the separation and determination of As(III) and As(V) have been investigated in detail. Under the optimized conditions, the detection limits of this method for As(III) were 0.0045 ng mL−1 with an enrichment factor of 33 and 0.24 ng mL−1 for As(V), and the relative standard deviations for As(III) and As(V) were 2.6% and 1.9% (n = 9, c = 1.0 ng mL−1), respectively. In order to verify the accuracy of the method, a certified reference of water sample was analyzed, and the results obtained were in good agreement with the certified values. The proposed method was applied for the analysis of inorganic arsenic species in groundwater and lake water with the recovery of 92-106%.  相似文献   

20.
A simple, rapid and accurate method on the basis of multicapillary gas chromatography (MCGC) combined with inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) was developed for speciation analysis of methylmercury (MeHg+) and inorganic mercury (Hg2+). The potential of the ICP-TOFMS for transient multi-isotope detection of very short signals (peak width of 0.4 s at half peak height) was evaluated. Two injection systems (purge-and-trap (PTI) and split (SI) injections) were compared in terms of species separation resolution and transient signal profile. Using purge-and-trap injection, after in situ derivatization of the ionic mercury species with sodium tetraethylborate, a baseline separation of MeHg+ and Hg2+ was achieved within a chromatographic run of <35 s. To correct for matrix-induced ion signal variation and instrumental drift, propylmercury (PrHg+) was used as internal standard. Detection limits of 16 and 257 fg g−1 for MeHg+ (as Hg) and Hg2+, respectively, were achieved. The analytical precision (R.S.D. (%)) for 10 successive injections of a standard mixture containing 10 pg MeHg+ (as Hg) and Hg2+ was 1.2% for MeHg+ and 4.1% for Hg2+. The method was validated by analysis of two biological certified reference materials (CRM): a dogfish muscle (DORM-2) and a freeze-dried tuna fish (CRM 464).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号