首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
A novel electrochemical aptasensor incorporating a signal enhancement for the determination of cocaine was designed. Gold nanoparticles were self‐assembled onto the surface of a gold electrode through 1,6‐hexanedithiol. A bifunctional derivative of the 32‐base cocaine‐binding aptamer with a redox‐active ferrocene moiety and a thiol linker group at the termini of the strand was self‐assembled onto the surface of gold nanoparticles. The oxidation peak current is linearly related to the concentration of cocaine from 1.0 to 15.0 μM with a detection limit of 0.5 μM. It was found that the sensitivity of the aptasensor with gold nanoparticles modification was ca. 10‐fold higher than that of the aptasensor without gold nanoparticles modification. This work demonstrates that gold nanoparticles‐assembled gold electrode provides a promising platform for immobilizing aptamer and enhancing the sensitivity.  相似文献   

2.
Du Y  Li B  Guo S  Zhou Z  Zhou M  Wang E  Dong S 《The Analyst》2011,136(3):493-497
The appearance of the aptamer provides good recognition elements for small molecules, especially for drugs. In this work, by combining the advantages of magnetic nanoparticles (MNPs) with colorimetric drug detection using hemin-G-quadruplex complex as the sensing element, we report a simple and sensitive DNAzyme-based colorimetric sensor for cocaine detection in a 3,3,5,5-tetramethylbenzidine sulfate (TMB)-H(2)O(2) reaction system. The whole experimental processes are simplified. Cocaine aptamer fragments, SH-C2, are covalently labeled onto the amine-functionalized MNPs. When the target cocaine and another cocaine aptamer fragments (C1) grafted with G-riched strand AG4 (i.e. C1-AG4) are present simultaneously, the C2 layer on MNPs hybridizes partly with C1-AG4 to bind the cocaine. The C1-AG4 can be combinded with hemin to form DNAzyme which can effectively catalyze the H(2)O(2)-mediated oxidation of TMB, giving rise to a change in solution color. Importantly, using MNPs as the separation and amplification elements could effectively reduce the background signal and the interference from the real samples. A linear response from 0.1 μM to 20 μM is obtained for cocaine and a detection limit of 50 nM is achieved, which provides high sensitivity and selectivity to detect cocaine.  相似文献   

3.
本文采用水热法合成了硫化铅量子点,将其与壳聚糖混合后修饰在玻碳电极上,利用PbS与巯基之间的强烈的键和作用,直接将所合成的带巯基的与可卡因适体互补的DNA固定到电极上,将金纳米颗粒标记在可卡因适体作为示踪物检测可卡因,研制了一种新型的用于快速测定可卡因的适体传感器.该适体传感器与不同浓度的可卡因培育时,可卡因适体与可卡...  相似文献   

4.
We report on an optical aptamer sensor for cocaine detection. The cocaine sensitive fluorescein isothiocyanate (FITC)-labeled aptamer underwent a conformational change from a partial single-stranded DNA with a short hairpin to a double-stranded T-junction in the presence of the target. The DNA minor groove binder Hoechst 33342 selectively bound to the double-stranded T-junction, bringing the dye within the Förster radius of FITC, and therefore initiating minor groove binder based energy transfer (MBET), and reporting on the presence of cocaine. The sensor showed a detection limit of 0.2 μM. The sensor was also implemented on a carboxy-functionalized polydimethylsiloxane (PDMS) surface by covalently immobilizing DNA aptamers. The ability of surface-bound cocaine detection is crucial for the development of microfluidic sensors.  相似文献   

5.
构建了一种可再生型三磷酸腺苷(ATP)适配体计时库仑电化学传感器.将一条短链DNA通过AuS键自组装固定在电极表面, ATP的核酸适配体与该短链DNA杂交而结合在电极表面.带负电的DNA通过静电吸引结合电解液中的六氨合钌(RuHex)阳离子.当传感器和靶分子ATP孵育后,ATP与核酸适配体结合,使适配体链从电极表面解离,电极表面吸附的DNA量减少,结合RuHex的量随之降低.通过计时库仑技术检测RuHex响应信号降低的量 ,可以对ATP进行定量测定.此传感器的电化学响应信号与ATP浓度对数值呈线性关系,线性检测范围为0.001~100 μmol/L,检出限(S/N=3)为0.5 nmol/L.此传感器检测靶分子ATP后,可以通过简单的操作步骤再生,再生5次后的响应信号为初始信号的90%以上.采用此传感器检测大鼠脑透析液中ATP的含量为(19.2±3.7) nmol/L (n=3).  相似文献   

6.
Based on the conformational changes of the aptamer-functionalized gold nanoparticles (AuNPs) onto MWCNTs/IL/Chit nanocomposite as the support platform, we have developed a sensitive and selective electrochemical aptasensor for the detection of cocaine. The 5′-amine-3′-AuNP terminated aptamer is covalently attached to a MWCNTs/IL/Chit nanocomposite. The interaction of cocaine with the aptamer functionalized AuNP caused the aptamer to be folded and the AuNPs with negative charge at the end of the aptamer came to the near of electrode surface therefore, the electron transfer between ferricyanide (K3Fe(CN)6) as redox probe and electrode surface was inhibited. A decreased current of (K3Fe(CN)6) was monitored by differential pulse voltammetry technique. In an optimized condition the calibration curve for cocaine concentration was linear up to 11 μM with detection limit (signal-to-noise ratio of 3) of 100 pM. To test the selectivity of the prepared aptasensor sensing platform applicability, some analgesic drugs as the interferes were examined. The potential of the aptasensor was successfully applied for measuring cocaine concentration in human blood serum. Based on our experiments it can be said that the present method is absolutely beneficial in developing other electrochemical aptasensor.  相似文献   

7.
实验合成了多边形金纳米颗粒,通过壳聚糖(CHIT)将合成的多边形金纳米颗粒固定在玻碳电极表面,然后通过自组装技术将带巯基的捕获DNA探针固定在修饰有多边形金纳米颗粒的电极表面,利用杂交反应使可卡因适体与DNA捕获探针结合,制成非标记型可卡因适体传感器。以六氨合钌作为电化学指示剂,通过测量传感器与目标物可卡因结合前后电流变化情况对可卡因进行测定。考察了缓冲溶液的pH、可卡因培育时间、扫描速度等对测定的影响。结果表明,在pH为7.40时该传感器的检测范围为1.0×10-10~1.0×10-3 mol/L,检测限为3.0×10-11 mol/L。该传感器制作简单,响应好,抗干扰能力强。  相似文献   

8.
A novel electrogenerated chemiluminescence aptamer-based (ECL-AB) biosensor for the determination of a small molecule drug is designed employing cocaine-binding aptamer as molecular recognition element for cocaine as a model analyte and ruthenium complex served as an ECL label. A 5′-terminal cocaine-binding aptamer with the ECL label at 3′-terminal of the aptamer was utilized as an ECL probe. The ECL-AB biosensors were fabricated by immobilizing the ECL probe onto a gold electrode surface via thiol-Au interactions. An enhanced ECL signal is generated upon recognition of the target cocaine, attributed to a change in the conformation of the ECL probe from random coil-like configuration on the probe-modified film to three-way junction structure, in close proximity to the sensor interface. The integrated ECL intensity versus the concentration of cocaine was linear in the range from 5.0 × 10−9 to 3.0 × 10−7 M. The detection limit was 1.0 × 10−9 M. This work demonstrates that the combination of a highly binding aptamer to analyte with a highly sensitive ECL technique to design ECL-AB biosensor is a great promising approach for the determination of small molecule drugs.  相似文献   

9.
Özalp VC 《The Analyst》2011,136(23):5046-5050
A quartz crystal microbalance with a dissipation monitoring (QCM-D) sensor was developed for highly sensitive and specific detection of adenosine-5'-triphosphate (ATP) by using an aptamer. The binding of ATP molecules on the aptamer films could be calculated as accurate mass changes using multiple frequency and dissipation measurements. The detection is achieved by calculating the mass changes from conformational rearrangements of the sensor surface upon interaction with the target. The sensor was demonstrated to respond to changes in ATP concentrations in real time suitable for continuous monitoring applications. This sensor showed excellent selectivity toward ATP compared with other chemically similar nucleotide GTP. The feasibility of the sensor was demonstrated by analyzing ATP concentrations in cell culture media with serum. The maximum frequency change was about -2 Hz after injection of 500 μM ATP. The affinity constant of the aptamer was determined to be 49 ± 7.59 μM. The proposed sensor can extend the application of the QCM-D system in medical diagnosis, and could be adopted for the detection of other small molecules with the use of specific aptamers.  相似文献   

10.
We report the integration of a nanomechanical sensor consisting of 16 silicon microcantilevers with polydimethylsiloxane (PDMS) microfluidics. For microcantilevers positioned near the bottom of a microfluidic flow channel, a transient differential analyte concentration for the top versus bottom surface of each microcantilever is created when an analyte-bearing fluid is introduced into the flow channel (which is initially filled with a non-analyte containing solution). We use this effect to characterize a bare (nonfunctionalized) microcantilever array in which the microcantilevers are simultaneously read out with our recently developed high sensitivity in-plane photonic transduction method. We first examine the case of non-specific binding of bovine serum albumin (BSA) to silicon. The average maximum transient microcantilever deflection in the array is -1.6 nm, which corresponds to a differential surface stress of only -0.23 mN m(-1). This is in excellent agreement with the maximum differential surface stress calculated based on a modified rate equation in conjunction with finite element simulation. Following BSA adsorption, buffer solutions with different pH are introduced to further study microcantilever array transient response. Deflections of 20-100 nm are observed (2-14 mN m(-1) differential surface stress). At a flow rate of 5 μL min(-1), the average measured temporal width (FWHM) of the transient response is 5.3 s for BSA non-specific binding and 0.74 s for pH changes.  相似文献   

11.
Electrochemical, aptamer-based (E-AB) sensors, which are comprised of an electrode modified with surface immobilized, redox-tagged DNA aptamers, have emerged as a promising new biosensor platform. In order to further improve this technology we have systematically studied the effects of probe (aptamer) packing density, the AC frequency used to interrogate the sensor, and the nature of the self-assembled monolayer (SAM) used to passivate the electrode on the performance of representative E-AB sensors directed against the small molecule cocaine and the protein thrombin. We find that, by controlling the concentration of aptamer employed during sensor fabrication, we can control the density of probe DNA molecules on the electrode surface over an order of magnitude range. Over this range, the gain of the cocaine sensor varies from 60% to 200%, with maximum gain observed near the lowest probe densities. In contrast, over a similar range, the signal change of the thrombin sensor varies from 16% to 42% and optimal signaling is observed at intermediate densities. Above cut-offs at low hertz frequencies, neither sensor displays any significant dependence on the frequency of the alternating potential employed in their interrogation. Finally, we find that E-AB signal gain is sensitive to the nature of the alkanethiol SAM employed to passivate the interrogating electrode; while thinner SAMs lead to higher absolute sensor currents, reducing the length of the SAM from 6-carbons to 2-carbons reduces the observed signal gain of our cocaine sensor 10-fold. We demonstrate that fabrication and operational parameters can be varied to achieve optimal sensor performance and that these can serve as a basic outline for future sensor fabrication.  相似文献   

12.
The present study reports the proof of principle of a reagentless aptameric sensor based on surface-enhanced Raman scattering (SERS) spectroscopy with "signal-on" architecture using a model target of cocaine. This new aptameric sensor is based on the conformational change of the surface-tethered aptamer on a binding target that draws a certain Raman reporter in close proximity to the SERS substrate, thereby increasing the Raman scattering signal due to the local enhancement effect of SERS. To improve the response performance, the sensor is fabricated from a cocaine-templated mixed self-assembly of a 3'-terminal tetramethylrhodamine (TMR)-labeled DNA aptamer on a silver colloid film by means of an alkanethiol moiety at the 5' end. This immobilization strategy optimizes the orientation of the aptamer on the surface and facilitates the folding on the binding target. Under optimized assay conditions, one can determine cocaine at a concentration of 1 muM, which compares favorably with analogous aptameric sensors based on electrochemical and fluorescence techniques. The sensor can be readily regenerated by being washed with a buffer. These results suggest that the SERS-based transducer might create a new dimension for future development of aptameric sensors for sensitive determination in biochemical and biomedical studies.  相似文献   

13.
《Electroanalysis》2018,30(2):378-385
The present work explains the fabrication of a novel electrochemical aptasensor for identifying and measuring the epirubicin (Epi) by using curcumin (Cur) as an anticancer electrochemical indicator. The aptasensor prepared by immobilizing the thiolated aptamer on the surface of graphite screen‐printed electrode modified with gold nanoparticles/functionalized multiwall carbon nanotubes, ionic liquid and chitosan nanocomposite (AuNPs/FMWCNTs‐IL‐Chit/SPE). To evaluate the willingness of aptamer to interaction with Epi in the presence of complementary strand DNA, competitive binding assay between the complementary strand of aptamer and Epi were used. Cur tends to bound to the grooves of two strands DNA. With increasing the concentration of Epi in the range of 0.007–7.0 μM, the peak current of Cur decreased, due to the formation of aptamer‐Epi complex and decreasing the amount of complementary strand DNA. Through the control experiments, we examined the response of fabricated aptasensor for some anticancer drugs, which have a structure similar to the Epi. The results showed that using the thiol‐terminated aptamer as a recognition layer led to a sensor with a high tendency for Epi compared to other anticancer drugs.  相似文献   

14.
Surface dilatational dynamic elasticity ε of films formed by cross-linked poly(N-isopropylacrylamide) microparticles on a water/air interface has been determined as a function of polymer surface concentration Γ. The experimental dependences exhibit two maxima of ε at surface pressures π of nearly 6 and 35 mN/m. In the region of the second maximum, the pattern of the dependence is governed by a method used to vary Γ. At π > 25 mN/m, film compression leads to the formation of a metastable monolayer, while the gradual addition of a microparticle dispersion results in the establishment of equilibrium between the monolayer and surface aggregates. In the region of π values corresponding to the second maximum of ε, slow relaxation processes with a characteristic time substantially longer than 10 s occur in the system. At π > 35 mN/m, the film collapses due to the displacement of microgel particles from the water surface.  相似文献   

15.
Biomolecular interactions over the surface of a microcantilever can produce its bending motion via changes of the surface stress, which is referred to nanomechanical response. Here, we have studied the interaction forces responsible for the bending motion during the formation of a self-assembled monolayer of thiolated 27-mer single-stranded DNA on the gold-coated side of a microcantilever and during the subsequent hybridization with the complementary nucleic acid. The immobilization of the single-stranded DNA probe gives a mean surface stress of 25 mN/m and a mean bending of 23 nm for microcantilevers with a length and thickness of about 200 microm and 0.8 microm, respectively. The hybridization with the complementary sequence could not be inferred from the nanomechanical response. The nanomechanical response was compared with data from well-established techniques such as surface plasmon resonance and radiolabeling, to determine the surface coverage and study the intermolecular forces between neighboring DNA molecules anchored to the microcantilever surface. From both techniques, an immobilization surface density of 3 x 10(12) molecules/cm(2) and a hybridization efficiency of 40% were determined. More importantly, label-free hybridization was clearly detected in the same conditions with a conventional sensor based on surface plasmon resonance. The results imply that the nanomechanical signal during the immobilization process arises mainly from the covalent attachment to the gold surface, and the interchain interactions between neighboring DNA molecules are weak, producing an undetectable surface stress. We conclude that detection of nucleic acid hybridization with nanomechanical sensors requires reference cantilevers to remove nonspecific signals, more sensitive microcantilever geometries, and immobilization chemistries specially addressed to enhance the surface stress variations.  相似文献   

16.
This work deals with the characterization of a phosphorothioate anchoring strategy for aptamer molecules linked to gold, in the context of electrochemical sensors, using adenosine aptamer as model system. Surface density of immobilized phosphorothioate oligonucleotide sequences has been explored for a range of oligonucleotide concentrations (0.055–55 μM), finding a consequent variation of molecular surface density (3.5×1011–2.8×1013 molecules/cm2). Most suitable aptamer concentration for adenosine recognition was also explored and found to be around 5.5 μM. As proof of concept of phosphorothioate strategy, electrochemical response to adenosine concentration was measured using a ferrocene‐labeled oligonucleotide sequence, and phosphorothioate anchoring thermal stability was compared to thiol immobilization.  相似文献   

17.
Aptamer-based colorimetric probe for cocaine   总被引:9,自引:0,他引:9  
Complex of an anti-cocaine aptamer and the dye diethylthiotricarbocyanine behaves as a colorimetric sensor with attenuation in absorbance at 760 nm for cocaine in the concentration range of 2-600 muM. Mechanistic studies indicate an intermolecular displacement of the dye as the mechanism of action of the sensor. As the dye is insoluble in buffer, cocaine binding can be followed with the unaided eye as displaced dye precipitates and supernatant decolorizes.  相似文献   

18.
基于适配子构建了无标记检测三磷酸腺苷(ATP)的微悬臂梁生物传感器。 将ATP适配子修饰在微悬臂梁阵列中的传感悬臂镀金面上,用来识别ATP,而参比悬臂修饰巯基己醇(MCH)防止非特异性吸附。 ATP与其适配子发生特异性相互作用,使悬臂的上下两个表面产生应力差,导致传感悬臂产生偏转,扣除参比悬臂偏转后其偏转值与ATP的浓度在0.5~5 mmol/L范围内有良好的线性关系,相关系数为0.998,最低检出限为0.06 mmol/L。 该微悬臂梁生物传感器响应快速、操作简单,并且对ATP具有良好的特异性。  相似文献   

19.
《Electroanalysis》2017,29(3):730-738
PtxSn/MWCNTs (x=1, 2, 3) nanocomposites were synthesized by chemical reduction. Comparing all of the materials, the results revealed that the best material was Pt3Sn/MWCNTs. The sensor based on Pt3Sn/MWCNTs exhibited excellent catalytic activities towards glucose and hydrogen peroxide. Sensing of glucose had a double‐linear range: one was between 50 μM and 550 μM, the other was between 1.35 mM and 16.35 mM. These were due to the fact that more and more intermediate species were adsorbed onto the electrode surface with increasing concentration of glucose, which limited the following glucose oxidation. Meanwhile, the sensor also had a linear response range between 0.05 mM and 18.95 mM for hydrogen peroxide. Furthermore, the glucose and hydrogen peroxide sensors exhibited excellent selectivity, stability, and reproducibility. Thus the sensors had potential utilities in the detection of glucose and hydrogen peroxide.  相似文献   

20.
一种简单灵敏的基于适配体的黄曲霉毒素B1电化学传感器   总被引:1,自引:0,他引:1  
黄曲霉毒素B1(AFB1)以其高毒性和致癌性成为食品安全隐患而备受关注. 本文拟构建一种新颖、简单、快速、灵敏的传感器用于谷物食品中AFB1的痕量检测. 将介孔碳(CMK)修饰在工作电极表面来增大电极的表面积,再将工作电极恒电位沉积金纳米粒子(AuNPs),提高电信号的同时,为下一步巯基化适配体的连接提供位点. 检测过程中,AFB1可以竞争性地去除吸附在适配体链上的亚甲基蓝(MB)引起电信号的变化,对AFB1进行定量检测. 修饰的工作电极导电性能得到改善,灵敏度大大提高,对AFB1的线性响应范围为0.1 ~ 75 μg·L-1,检出限低至36 ng·L-1. 在对不同谷物食品(大米、玉米、糯米)进行加标回收实验中,回收率在92.3% ~ 103.6%范围之间,实现对目标物的定量检测. 本文为食品中AFB1快速检测方法提供了一种新思路和新方法.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号