首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new type of electron ionization LC‐MS with supersonic molecular beams (EI‐LC‐MS with SMB) is described. This system and its operational methods are based on pneumatic spray formation of the LC liquid flow in a heated spray vaporization chamber, full sample thermal vaporization and subsequent electron ionization of vibrationally cold molecules in supersonic molecular beams. The vaporized sample compounds are transferred into a supersonic nozzle via a flow restrictor capillary. Consequently, while the pneumatic spray is formed and vaporized at above atmospheric pressure the supersonic nozzle backing pressure is about 0.15 Bar for the formation of supersonic molecular beams with vibrationally cold sample molecules without cluster formation with the solvent vapor. The sample compounds are ionized in a fly‐though EI ion source as vibrationally cold molecules in the SMB, resulting in ‘Cold EI’ (EI of vibrationally cold molecules) mass spectra that exhibit the standard EI fragments combined with enhanced molecular ions. We evaluated the EI‐LC‐MS with SMB system and demonstrated its effectiveness in NIST library sample identification which is complemented with the availability of enhanced molecular ions. The EI‐LC‐MS with SMB system is characterized by linear response of five orders of magnitude and uniform compound independent response including for non‐polar compounds. This feature improves sample quantitation that can be approximated without compound specific calibration. Cold EI, like EI, is free from ion suppression and/or enhancement effects (that plague ESI and/or APCI) which facilitate faster LC separation because full separation is not essential. The absence of ion suppression effects enables the exploration of fast flow injection MS‐MS as an alternative to lengthy LC‐MS analysis. These features are demonstrated in a few examples, and the analysis of the main ingredients of Cannabis on a few Cannabis flower extracts is demonstrated. Finally, the advantages of EI‐LC‐MS with SMB are listed and discussed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography‐mass spectrometry (LC‐MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC‐MS with supersonic molecular beams (SMB). The EI‐LC‐MS‐SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI‐LC‐MS‐SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal‐to‐noise ratio of over 10 000 for the API and almost uniform response.  相似文献   

3.
High resolution capillary gas chromatography–mass spectrometry has been used in combination with various sample preparation methods to analyze a wide range of low molecular weight organic contaminants in municipal wastewaters. Volatile organic compounds were extracted using a purge and trap concentrator connected directly to a wide bore DB-624 capillary column. Because of the high organic load in wastewater samples, this method was preferred to the more sensitive closed loop stripping technique which suffered from competition effects and insufficient adsorbent capacity. Volatile and semi-volatile base/neutral compounds and acids were extracted with dichloromethane at pH 11 and pH 2, respectively, or were recovered using a simultaneous distillation-extraction procedure. Acidic compounds were subsequently derivatized using diazomethane methylation. Both fractions were separated with a 30m DB-5ms capillary column. Specific ionic substances (LAS, NTA, EDTA) were isolated by solid-phase extraction then derivatized with diazomethane (LAS) or acetyl chloride in n-butanol (NTA, EDTA) before GC–MS analysis. This array of techniques enabled the identification of more than 150 organic contaminants in the influent of a municipal wastewater treatment plant in northern suburban Paris. The individual concentrations of these contaminants ranged from < 0.1 μg/l to 5.7 mg/l.  相似文献   

4.
Dispersive liquid–liquid microextraction method was developed for the determination of the amount of phthalate esters in bottled drinking water samples and dispersive liquid–liquid microextraction samples were analyzed by GC–MS. Various experimental conditions influencing the extraction were optimized. Under the optimized conditions, very good linearity was observed for all analytes in a range between 0.05 and 150 μg/L with coefficient of determination (R2) between 0.995 and 0.999. The LODs based on S/N = 3 were 0.005–0.22 μg/L. The reproducibility of dispersive liquid–liquid microextraction was evaluated. The RSDs were 1.3–5.2% (n = 3). The concentrations of phthalates were determined in bottled samples available in half shell. To understand the leaching profile of these phthalates from bottled water, bottles were exposed to direct sunlight during summer (temperature from 34–57°C) and sampled at different intervals. Result showed that the proposed dispersive liquid–liquid microextraction is suitable for rapid determination of phthalates in bottled water and di‐n‐butyl, butyl benzyl, and bis‐2‐ethylhexyl phthalate compounds leaching from bottles up to 36 h. Thereafter, degradation of phthalates was observed.  相似文献   

5.
In this study, GC–MS‐ and MEKC‐based methods for determination of caffeine (CAF) in preworkout supplements were developed and validated. The proposed protocols utilized minimal sample preparation (simple dilution and syringe filtration). The developed methods achieved satisfactory validation parameters, i.e. good linearity (R2 > 0.9988 and R2 > 0.9985 for GC–MS‐ and MEKC‐based method, respectively), satisfactory intra‐ and interaccuracy (within 92.6–100.7% for method utilizing GC–MS and 92.1–110.3% for protocol based on MEKC) and precision (CV < 15.9% and CV < 6.3% for GC–MS‐ and MEKC‐based method, respectively) and recovery (within 100.1–100.8% for method utilizing GC–MS and 101.5–106.2% for protocol based on MEKC). The LOD was 0.03 and 3 μg/mL for method utilizing GC–MS and MEKC, respectively. The CAF concentrations determined by GC–MS‐ and MEKC‐based methods were found to be in the range of 8.53–11.23 and 8.20–11.61 μg/mL, respectively. Taking into consideration information on the labels, the investigated supplements were found to contain from 110.0 to 167.3% of the declared CAF content, which confirmed the literature reports on incompatibility of the declared product compositions with real ones. Nevertheless, the consumption of examined supplements as recommended by producers did not lead to exceeding the CAF safe limit of 400 mg per day. Additionally, the MEKC‐based method allowed for detection and identification of vitamin B3 and B6 in all of the investigated supplement samples, which demonstrated that MEKC‐based protocols may be an appropriate assays for simultaneous determination of CAF and vitamins.  相似文献   

6.
Complete GC–SIM/MS separation and identification of 19 steroids (including several steroid isomers) in a male urine sample, as their per-trimethylsilyl ethers, is described. Trimethylsilylation of their functional groups (hydroxyl and carbonyl) was achieved by a rapid, simplified and one-step derivatization method, using N -methyl- N -trimethylsilyl-2,2,2,-trifluoroacetamide as the silylating agent and the solvent as well, along with catalytic amounts of trimethylsilyl iodide and dithioerythritol. Furthermore, a GC/MS method for the analysis of a synthetic mixture of underivatized urinary steroids is proposed. © 1997 by John Wiley & Sons, Ltd.  相似文献   

7.
The determination of organochlorine pesticides in water samples, which are harmful to humans, is very important for environmental risk assessment. Based on the excellent adsorption properties of graphene, an SPE coupled with GC–MS method for the monitoring of organochlorines (four hexachlorcyclohexanes and four dichlorodiphenyltrichloroethanes) was developed. Owing to the hydrophobic interaction and π–π stacking interaction between the analytes and graphene, the analytes quantitatively adsorbed onto the graphene‐based SPE cartridge were eluted by ethyl acetate for analysis. Several parameters influencing the analytical performance, such as the kind of elution, sample volume, reusability of the cartridge, have been investigated in detail. Under the optimal conditions, detection of limits of 1.95–9.38 ng/L, recoveries of 83.9–107.3% at two spiked concentration levels (0.1 and 10 ng/mL) and RSDs in the range of 2.9–7.4% for real water samples were obtained for all the analytes. This work reveals the great potential of graphene in sample preparation procedures.  相似文献   

8.
An optimized quick, easy, cheap, effective, rugged and safe method for the simultaneous determination of difenoconazole, trifloxystrobin and its metabolite trifloxystrobin acid residues in watermelon and soil was developed and validated by gas chromatography with tandem mass spectrometry. The samples were extracted with acetonitrile (1% formic acid) and cleaned up by dispersive solid‐phase extraction with octadecylsilane sorbent. The limit of quantification of the method was 0.01 mg/kg, and the limit of detection was 0.003 mg/kg for all three analytes. The recoveries of the fungicides in watermelon, pulp and soil were 72.32–99.20% for difenoconazole, 74.68–87.72% for trifloxystrobin and 78.59–92.66% for trifloxystrobin acid with relative standard deviations of 1.34–14.04%. The dissipation dynamics of difenoconazole and trifloxystrobin in watermelon and soil followed the first‐order kinetics with half‐lives of 3.2–8.8 days in both locations. The final residue levels of difenoconazole and trifloxystrobin were below 0.1 mg/kg (maximum residue level [MRL] set by China) and 0.2 mg/kg (MRL set by European Union), respectively, in pulp samples collected 14 days after the last application. These results could help Chinese authorities to establish MRL of trifloxystrobin in watermelon and provide guidance for the safe and proper application of both fungicides on watermelon.  相似文献   

9.
Centella asiatica has been used as a culinary vegetable or medicinal herb. In this study, the hepatoprotective effect of the standardized extract of C. asiatica (ECa233) in rotenone‐treated rats was examined using a GC–MS‐based metabolomic approach. ECa233 contains >80% triterpenoids with a ratio of madecassoside to asiaticoside of 1.5(±0.5):1. Rats were randomly divided into three groups (with six rats/group): sham negative control, rotenone positive control and the ECa233 test group. Rats in the ECa233 group received 10 mg/kg ECa233 orally for 20 days, followed by 2.5 mg/kg intraperitoneal rotenone injection to induce toxicity before being sacrificed. Metabolomic analysis showed that supplementation of ECa233 protected rat liver against rotenone toxicity. Pipecolinic acid was one of the most important metabolites; its level was decreased in the rotenone group as compared with the control. Supplementation with ECa233 before administration of rotenone raised pipecolinic acid to levels intermediate between controls and rotenone alone. The metabolomics approach also helped discover a possible new genuine epimetabolite in the present work. Antioxidant tests revealed that ECa233 inhibited lipid peroxidation and increased catalase activities in liver tissue.  相似文献   

10.
11.
Identification of cis/trans isomers of unsaturated fatty acids cannot usually be achieved by GC-MS (gas chromatography-mass spectrometry) without reference substances. In this study a GC-FTIR-MS system (gas chromatography-Fourier transform-mass spectrometry) was used to identify fatty acid methyl esters (FAMEs) and differentiate between the cis/trans isomers. Besides methyl esters, 2-alkenyl-4,4-dimethyloxazoline derivatives (DMOX), which have been used to locate double bond positions of unsaturated fatty acids, were examined with respect to their suitability for cis/trans differentiation. A combined GC-FTIR-MS system with a wide band (4000–550 cm?1) mercury cadmium telluride (MCT) detector was used in series and parallel to identify 31 reference unsaturated fatty acids, including 7 pairs of cis/trans isomers. Serum samples of healthy persons and commercially available fish oil were analyzed as examples of complex mixtures. Using splitless injection the detection limit for the less sensitive IR detector was 25 ng/μl in case of the weak cis and trans bands. In the FTIR spectra cis/trans isomers were identified by analysis of bands arising from C? H out-of-plane (oop) bending: for both the FAME and DMOX derivatives cis-1,2-disubstituted double bonds give a strong band near 720 cm?1 and the corresponding trans isomers near 967 cm?1. cis Isomers could be identified further by a band at 3012 cm?1. With the combined data of the GC-FTIR-MS system it is now possible to identify polyunsaturated fatty acids with regard to the discrimination of cis/trans isomers.  相似文献   

12.
Synthetic musks are organic compounds used as fragrance additives and fixative compounds in a diversity of personal care products. A new method based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction followed by GC–MS for the analysis of 12 musks in personal care products was developed and validated. Some experimental parameters, such as total QuEChERS mass, sample mass/solvent volume ratio, type of extraction solvent, as well as salts and sorbents amount were investigated and optimized. The final method involves the musks extraction using acetonitrile, followed by the addition of anhydrous magnesium sulphate and sodium acetate. The clean‐up step was performed using dispersive SPE with primary and secondary amine and octadecyl–silica sorbents. This extraction procedure is fast (about 10 min) when compared to other traditional approaches. The method was robust for the matrices studied and shows a high precision (%RSD < 15%) and accuracy (average recovery of 85%), allowing the detection of musks in minimum concentrations between 0.01 ng/g (galaxolide) and 15.80 ng/g (musk xylene). The developed method was applied to the analysis of 12 samples, which revealed musks concentrations ranging from 2 ng/g (toothpaste) to 882 340 ng/g (perfumed body lotion).  相似文献   

13.
Insects are of growing significance in veterinary medicine and human healthcare; therefore, an understanding of their biology is very important. The cuticular and internal fatty acid compositions of Chorthippus brunneus males and females have been studied for the first time. The lipids of males and females were separated into classes of compounds using high‐performance liquid chromatography with a laser light scattering detector. The free fatty acid (FFA) fractions obtained by HPLC were silylated and then analyzed by GC–MS. The cuticular lipids of males contained 15 saturated, four unsaturated with even‐numbered and two unsaturated with odd‐numbered carbon chains, FFAs ranging from C8 to C25. The major free fatty acids in males were C16 (20.8%), C18:2 (8.5%), C18:1 (32.9%) and C18 (24.4%). The cuticular lipids of females contained 17 saturated, four monounsaturated and two diunsaturated free fatty acids ranging from C8 to C30. The major cuticular fatty acids in females were C16 (25.1%), C18:2 (6.2%), C18:1 (23.7%) and C18:0 (33.2%). The internal FFAs of males consisted of 20 compounds ranging from C8 to C26. Four of these compounds were detected as major compounds: C16 (14.1%), C18:2 (21.6%), C18:1 (38.0%) and C18 (22.5%). Among 18 internal free fatty acids of females, C16 (22.3%), C18:2 (10.9%), C18:1 (40.2%) and C18 (20.5%) were the most abundant compounds. The following cuticular fatty acids present in the lipids of females were absent in the lipids of males: C26, C27 and C30. On the other hand, only C24 was absent from the cuticular lipids of females. Only C10 and C24 internal fatty acids present in the lipids of males were absent in the lipids of females. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
By using a nontargeted GC–MS approach, 153 individual volatile compounds were found in extracts from untoasted, light toasted and medium‐toasted cherry, chestnut, false acacia, as well as European and American ash wood, used in cooperage for aging wines, spirits and other beverages. In all wood types, the toasting provoked a progressive increase in carbohydrate derivatives, lactones and lignin constituents, along with a variety of other components, thus increasing the quantitative differences among species with the toasting intensity. The qualitative differences in the volatile profiles allow for identifying woods from cherry (being p‐anisylalcohol, p‐anisylaldehyde, p‐anisylacetone, methyl benzoate and benzyl salicylate detected only in this wood), chestnut (cis and trans whisky lactone) and false acacia (resorcinol, 3,4‐dimethoxyphenol, 2,4‐dihydroxy benzaldehyde, 2,4‐dihydroxyacetophenone, 2,4‐dihydroxypropiophenone and 2,4‐dihydroxy‐3‐methoxyacetophenone), but not those from ash, because of the fact that all compounds present in this wood are detected in at least one other. However, the quantitative differences can be clearly used to identify toasted ash wood, with tyrosol being most prominent, but 2‐furanmethanol, 3‐ and 4‐ethylcyclotene, α‐methylcrotonolactone, solerone, catechol, 3‐methylcatechol and 3‐hydroxybenzaldehyde as well. Regarding oak wood, its qualitative volatile profile could be enough to distinguish it from cherry and acacia woods, and the quantitative differences from chestnut (vanillyl ethyl ether, isoacetovanillone, butirovanillone, 1‐(5‐methyl‐2‐furyl)‐2‐propanone and 4‐hydroxy‐5,6‐dihydro‐(2H)‐pyran‐2‐one) and ash toasted woods. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Curcumae longae rhizome is a widely used traditional herb in many countries. Various geographical origins of this herb might lead to diversity or instability of the herbal quality. The objective of this work was to establish the chemical fingerprints for quality control and find the chemical markers for discriminating these herbs from different origins. First, chemical fingerprints of essential oil of 24 C. longae rhizome from four different geographical origins in China were determined by GC–MS. Then, pattern recognition techniques were introduced to analyze these abundant chemical data in depth; hierarchical cluster analysis was used to sort samples into groups by measuring their similarities, and principal component analysis and partial least‐squares discriminate analysis were applied to find the main chemical markers for discriminating these samples. Curcumae longae rhizome from Guangxi province had the highest essential oil yield (4.32 ± 1.45%). A total of 46 volatile compounds were identified in total. Consistent results were obtained to show that C. longae rhizome samples could be successfully grouped according to their origins, and turmerone, ar‐turmerone, and zingiberene were the characteristic components for discriminating these samples of various geographical origins and for quality control. This finding revealed that fingerprinting analysis based on GC–MS coupled with chemometric techniques could provide a reliable platform to discriminate herbs from different origins, which is a benefit for quality control.  相似文献   

16.
An Open Probe inlet was combined with a low thermal mass ultra‐fast gas chromatograph (GC), in‐vacuum electron ionization ion source and a mass spectrometer (MS) of GC–MS for obtaining real‐time analysis with separation. The Open Probe enables ambient sampling via sample vaporization in an oven that is open to room air, and the ultra‐fast GC provides ~30‐s separation, while if no separation is required, it can act as a transfer line with 2 to 3‐s sample transfer time. Sample analysis is as simple as touching the sample, pushing the sample holder into the Open Probe oven and obtaining the results in 30 s. The Open Probe fast GC was mounted on a standard Agilent 7890 GC that was coupled with an Agilent 5977A MS. Open Probe fast GC–MS provides real‐time analysis combined with GC separation and library identification, and it uses the low‐cost MS of GC–MS. The operation of Open Probe fast GC–MS is demonstrated in the 30‐s separation and 50‐s full analysis cycle time of tetrahydrocannabinol and cannabinol in Cannabis flower, sub 1‐min analysis of trace trinitrotoluene transferred from a finger onto a glass surface, vitamin E in canola oil, sterols in olive oil, polybrominated flame retardants in plastics, alprazolam in Xanax drug pill and free fatty acids and cholesterol in human blood. The extrapolated limit of detection for pyrene is <1 fg, but the concentration is too high and the software noise calculation is untrustworthy. The broad range of compounds amenable for analysis is demonstrated in the analysis of reserpine. The possible use with alternate standard GC–MS and Open Probe fast GC–MS is demonstrated in the analysis of heroin in its street drug powder. The use of Open Probe with the fast GC acting as a transfer line is demonstrated in <10‐s analysis without separation of ibuprofen and estradiol. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

17.
A simple, rapid, accurate and sensitive method using microextraction by packed sorbent (MEPS) followed by GC–MS has been pursued for the determination of organochlorine insecticide endosulfan isomers (α and β) and their metabolites (ether, lactone and sulfate). MEPS is a miniaturised version of SPE employing C18 packing material. It is very efficient technique as it employs as low as 10 μL of sample volume. The distinct feature of MEPS is the magnitude of the elution volume that could be directly injected to GC system. Various parameters such as extraction cycles, washing solvent, elution solvent, elution volume and pH, which influenced the MEPS performance, were tested and optimised. The calibration curves were obtained in the concentration range 1–500 ng/mL. The results showed a close correlation coefficient (R2 > 0.991) for all analytes in the calibration range studied. The LOD and LOQ obtained for GC–MS under selected ion monitoring acquisition are between 0.0038–0.01 and 0.0125–0.033 ng/mL, respectively. The developed method is applicable for the quantification of these compounds in tap water and commercial samples. This method has been shown to be selective as no interferences from endogenous substances were detected by analysis. This method not only decreases sample preparation time but is cheaper, eco‐friendly and easier to perform compared to traditional techniques.  相似文献   

18.
The commercial value of cashew nut shell liquid (CNSL) has become a cornerstone of the agrowaste industry. It is the by‐product of the cashew industry and has an 1/8 inch thickness of soft honeycomb structure. CNSL contains phenolic lipids with aliphatic chains such as anacardic acid, cardanol, cardol and methyl cardol, and their derivatives. The developed GC–MS method is rapid, accurate and selective using a selected derivatizing reagent, namely N‐methyl‐N‐(trimethylsilyl)‐trifluoroacetamide that was previously diluted 1:1% with anhydrous pyridine. The proposed GC–MS method was applied for the analysis of different CNSL samples. The results showed that all classes of CNSL compounds were detected. The four alkyl phenols were detected with their different alkyl sidechains without any interference. This method is also specified for the detection of fatty acids of saturated and unsaturated chains. Silylation did not cause any alteration in the chemical structure of CNSL compounds regardless of esterification action. Silylation is considered a safe derivatizing agent compatible with GC chromatography and specific for all volatile and nonvolatile polar and nonpolar CNSL compounds that could be detected in CNSL samples.  相似文献   

19.
A method for the determination of 14 polybrominated diphenyl ethers (PBDEs) in sludge from wastewater treatment plants is presented. PBDEs were extracted by matrix solid‐phase dispersion assisted by sonication and determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode, using labelled 13C‐PBDEs as internal standards. The limits of detection and quantification for the tri‐ to hepta‐BDEs were in the range of 0.05 to 0.5 ng/g dry weight and 0.15 to 1.8 ng/g dry weight, respectively, and 1.6 ng/g dry weight and 5.6 ng/g dry weight for deca‐BDE‐209. The proposed analytical method was applied to determine PBDE levels in sewage sludge samples collected from 19 water treatment plants located in the province of Madrid (Spain). In all of the examined samples, BDE‐100 and BDE‐154 were the main compounds found with a mean concentration of 3.9 and 2.0 ng/g, respectively. PBDEs were detected in all of the samples, and their total concentrations not considering BDE‐209 were between 3.9 and 23.0 ng/g dry weight. The dominant PBDE congener in sewage sludge was BDE‐209, which constituted 38.7 to 97.3% of the total, and showed concentration levels ranging from 8.1 to 717.2 ng/g dry weight.  相似文献   

20.
Gas chromatography-mass spectrometry (GC-MS) with supersonic molecular beams (SMBs) (also named Supersonic GC-MS) is based on GC and MS interface with SMBs and on the electron ionization (EI) of vibrationally cold analytes in the SMBs (cold EI) in a fly-through ion source. This ion source is inherently inert and further characterized by fast response and vacuum background filtration capability. The same ion source offers three modes of ionization including cold EI, classical EI and cluster chemical ionization (CI). Cold EI, as a main mode, provides enhanced molecular ions combined with an effective library sample identification, which is supplemented and complemented by a powerful isotope abundance analysis method and software. The range of low-volatility and thermally labile compounds amenable for analysis is significantly increased owing to the use of the contact-free, fly-through ion source and the ability to lower sample elution temperatures through the use of high column carrier gas flow rates. Effective, fast GC-MS is enabled particularly owing to the possible use of high column flow rates and improved system selectivity in view of the enhancement of the molecular ion. This fast GC-MS with SMB can be further improved via the added selectivity of MS-MS, which by itself benefits from the enhancement of the molecular ion, the most suitable parent ion for MS-MS. Supersonic GC-MS is characterized by low limits of detection (LOD), and its sensitivity is superior to that of standard GC-MS, particularly for samples that are hard for analysis. The GC separation of the Supersonic GC-MS can be improved with pulsed flow modulation (PFM) GC x GC-MS. Electron ionization LC-MS with SMB can also be combined with the Supersonic GC-MS, with fast and easy switching between these two modes of operation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号