首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study described a fully automated method using on‐line solid phase extraction of large volume injections coupled with high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) to simultaneously detect a group of recalcitrant microconstituents (pharmaceuticals and personal care products, steroid hormones and sterols) in aqueous matrices. Samples (1 mL to 20 mL) were loaded to the preconcentration column at 1 mL/min, and the column was washed with 1000 μL of 25% methanol in LC/MS water to remove polar and ionic interferences before LC‐MS/MS analysis. Three different atmospheric pressure ionization (API) techniques, including photoionization (APPI) with four different dopants (acetone, anisole, chlorobenzene and toluene), heated electrospray ionization (HESI) and atmospheric pressure chemical ionization (APCI), were evaluated on the basis of method detection limits (MDLs) and recoveries from different aqueous matrixes. Results indicated that APPI with toluene as dopant was the most sensitive ionization method for the majority of the analytes. When using 5 mL of sample, MDLs for pharmaceuticals and personal care products, including carbamazepine, DEET, caffeine, naproxen, acetaminophen and primidone, were between 0.3 ng/L and 15 ng/L. MDLs of hormones, including testosterone, equilenin, progesterone, equilin, 17β‐estradiol, 17α‐ethynylestradiol, estrone, androsterone, mestranol and estriol, were between 1.2 ng/L and 37 ng/L. The combination of APPI with dopant allowed the detection of two difficult to ionize fecal related sterols, such as coprostan‐3‐ol and coprostan‐3‐one with MDLs of 5.4 ng/L and 11 ng/L, respectively. Calculated MDLs are more than adequate for analysis of wastewater using 1 to 5 mL sample size and for surface waters using up to 20 mL sample size. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A high‐throughput LC–MS/MS bioanalytical method was developed and validated for the determination of hydrocortisone in mouse serum via supported liquid extraction (SLE) in a 96‐well plate format. Although sample extracts from SLE result in similar matrix effects compared with conventional liquid–liquid extraction (LLE), greater analyte extraction recovery and much higher analysis throughput for the quantitative analysis of hydrocortisone in mouse serum were obtained. The current LC‐MS/MS method was validated for a concentration range of 2.00–2000 ng/mL for hydrocortisone using a 0.100 mL volume of mouse serum. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentration levels showed ≤12.9% CV and ?3.4–6.2% bias for the analyte in mouse serum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid and sensitive LC‐MS/MS method was developed for the determination of linarin in small‐volume rat plasma and tissue sample. Sample preparation was employed by the combination of protein precipitation (PPT) and liquid–liquid extraction (LLE) to allow measurement over a 5‐order‐of‐magnitude concentration range. Fast chromatographic separation was achieved on a Hypersil Gold column (100 × 2.1 mm i.d., 5 µm). Mass spectrometric detection was achieved using a triple‐quadrupole mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. Quantification was performed using selected reaction monitoring of precursor‐product ion transitions at m/z 593 → 285 for linarin and m/z 447 → 271 for baicalin (internal standard). The total run time was only 2.8 min per sample. The calibration curves were linear over the concentration range of 0.4–200 µg/mL for PPT and 0.001–1.0 µg/mL for LLE. A lower limit of quantification of 1.0 ng/mL was achieved using only 20 μL of plasma or tissue homogenate. The intra‐ and inter‐day precisions in all samples were ≤14.7%, while the accuracy was within ±5.2% of nominal values. The validated method has been successfully applied to pharmacokinetic and tissue distribution study of linarin. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
建立了同时测定渔业养殖水中氢化可的松、泼尼松、醋酸可的松、睾酮、甲睾酮、黄体酮及苯丙酸诺龙等7种激素残留药物的超高压液相色谱-电喷雾电离串联质谱(UPLC-ESI-MS/MS)分析方法.水样用HLB固相萃取柱净化、浓缩后,洗脱液经氮气吹干,残渣用乙腈-水(V∶V=1∶1)溶解,以乙腈和0.1%甲酸水溶液为流动相,经ZORBAXSB-C18色谱柱分离后进行LC-MS/MS多反应检测模式作定性定量分析.方法在0.5~40μggL或1~40μg/L范围具有良好的线性,相关系数大于0.997,检出限(S/N=3)为0.03~0.3μg/L,平均回收率为74.8%~113.0%,相对标准偏差为4.0%~16%.方法适用于渔业养殖水中7种激素的检测分析.  相似文献   

5.
A novel technique utilizing the adsorptive potential of immobilized multi‐walled carbon nanotubes (I‐MWCNT) in hollow fiber liquid‐phase microextraction (HF‐LPME) was developed for the determination of diuretics in urine. In this study, the potential of carbon nanotubes as a sorbent for three‐phase liquid‐phase microextraction of diuretics from urine samples was evaluated. Analysis was performed using liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). A novel method was applied to detect acetazolamide (AAA), chlorothiazide (CTA), hydrochlorothiazide (HCT), hydroflumethiazide (HFT), clopamide (CA), trichlormethiazide (TCM), althiazide (AT) and bendroflumethiazide (BFT) in urine. Two‐step extractions using different times and temperatures for each step were adopted. Parameters influencing the extraction efficiency, including the extraction solvent, sample pH, salt concentration, extraction time and extraction temperature were systematically optimized. Under the resulting optimal extraction conditions, this method showed good linearity over an analytes concentration range of 1 to 1000 ng/mL, high extraction repeatability with relative standard deviations of less than 6%, and low detection limits (0.09 to 0.51 ng/mL). The application of the methods to the determination of diuretics in real samples was tested by analyzing urine samples of patient.  相似文献   

6.
A robust ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for the determination of morphine‐6‐d ‐glucuronide (M6G), morphine‐3‐d ‐glucuronide (M3G) and morphine (MOR) in human plasma and urine has been developed and validated. The analytes of interest were extracted from plasma by protein precipitation. The urine sample was prepared by dilution. Both plasma and urine samples were chromatographed on an Acquity UPLC HSS T3 column using gradient elution. Detection was performed on a Xevo TQ‐S tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. Matrix interferences were not observed at the retention time of the analytes and internal standard, naloxone‐D5. The lower limits of quantitation of plasma and urine were 2/0.5/0.5 and 20/4/2 ng/mL for M6G/M3G/MOR, respectively. Calibration curves were linear over the concentration ranges of 2–2000/0.5–500/0.5–500 and 20–20,000/4–4000/2–2000 ng/mL for M6G/M3G/MOR in plasma and urine samples, respectively. The precision was <7.14% and the accuracy was within 85–115%. Furthermore, stability of the analytes at various conditions, dilution integrity, extraction recovery and matrix effect were assessed. Finally, this quantitative method was successfully applied to the pharmacokinetic study of M6G injection in Chinese noncancer pain patients.  相似文献   

7.
Abstract

A fast, efficient and low-cost high performance liquid chromatography–tandem mass spectrometry methodology was developed and validated for the simultaneous determination of free urinary cortisone, cortisol and their tetrahydro-metabolites. The developed method comprises a simple liquid-liquid extraction with CH2Cl2, followed by reversed-phase liquid chromatography–tandem mass spectrometry (LC–MS/MS) with electrospray ionization (ESI) in positive mode. The baseline chromatographic separation of the analytes, including the stereoisomers tetrahydrocortisol (THF) and allo-THF, was achieved on a Hypersil Gold C18 column with a mobile phase consisting of 0.05%v/v formic acid in water—acetonitrile, using a gradient elution program. The influence of the mobile phase composition and the ESI parameters on the sensitivity of the method was extensively studied. Sample preparation was also optimized, testing two techniques: solid phase extraction (SPE) and liquid-liquid extraction (LLE). Recoveries ranged from 74.7% (a-THF) to 93.5% (cortisol) and the method limits of detection (MLD) ranged from 0.34?ng mL?1 (cortisol) to 1.37?ng mL?1 (THF). Intra- and inter-day coefficient of variation of the assay varied from1.5% (allo-THF) to 13% (tetrahydrocortisone) and from 3.6% (allo-THF) to 14.9% (tetrahydrocortisone), respectively. The method was applied for the analysis of urine samples from 53 healthy individuals with a mean age of 13.96?years in order to estimate the concentration of the five corticosteroids and the ratio of the metabolites. Associations between urinary cortisol/cortisone and serum cortisol/cortisone values were also characterized.  相似文献   

8.
A new, fast and simple analytical method that is able to identify and quantify simultaneously 17 steroid hormones and metabolites (pregnenolone, 17‐OH‐pregnenolone, progesterone, 17‐OH‐progesterone, androsterone, androstenedione, dehydroepiandrosterone, dehydroepiandrosterone sulfate, testosterone, cortisol, corticosterone, aldosterone, 11‐deoxycortisol, 11‐deoxycorticosterone, dihydrotestosterone, estrone and estradiol) has been developed in equine serum using the ultra‐high‐performance liquid chromatography–tandem mass spectrometry technique. A total of 400 µl of sample was deproteinized with 1000 µl of acetonitrile, evaporated, restored with 50 µl of a solution of 25% methanol and injected in ultra‐high‐performance liquid chromatography–tandem mass spectrometry triple quadrupole. The recovery percentage obtained by spiking the matrix at two different concentrations with a standard mixture of steroid hormones was in all cases higher than 85.60% and with the percentage of coefficient of variation lower than 8.37%. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.9922–0.9986, and the limits of detection and limits of quantification were in the range of 0.002–2 and 0.0055–5.5 ng ml−1, respectively. The detected limit of quantification for testosterone (i.e. 50 pg ml−1) is twofold lower with respect to its threshold admitted in geldings plasma (100 pg ml−1 free testosterone). The high sensitivity and the quantitative aspect of the method permitted to detect most of the steroids in equine serum. Once validated, the method was used to quantify 17 steroid hormones in mare, stallion and gelding serum samples. The main steroids detected were corticosterone (range 37.25–51.26 ng ml−1) and cortisol (range 32.57–52.24 ng ml−1), followed by 17‐OH‐pregnenolone, dihydrotestosterone and pregnenolone. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
液相色谱-串联质谱法测定尿液中的内源性类固醇激素   总被引:2,自引:0,他引:2  
王萌烨  向平  严慧  沈保华  沈敏 《色谱》2008,26(1):10-14
建立了液相色谱-串联质谱(LC-MS/MS)测定尿液中的内源性类固醇激素的方法。尿样经葡萄糖醛酸甙酶酶解后进行液-液提取,以甲醇-0.1%甲酸缓冲液(含0.02 mol/L乙酸铵)(体积比为68:32)为流动相,采用Cosmosil C18色谱柱分离,并以三重四极杆串联质谱多反应监测扫描方式对尿样中的脱氢表雄酮(DHEA)、睾酮、表睾酮、雄酮和苯胆烷醇酮等5种激素进行检测。方法的最低检出限为0.01~10 ng/mL,平均回收率为96.7%~106.5%,日内和日间相对标准偏差(RSD)分别小于7%和11%。应用所建立的方法测定了健康志愿者口服DHEA后尿液中内源性类固醇激素的变化情况,结果表明该方法样品处理简便,色谱分离完全,结果准确可靠,可替代气相色谱-质谱法用于体液中内源性类固醇激素兴奋剂的常规分析。  相似文献   

10.
A specific and robust LC–MS/MS method was developed and validated for the quantitative determination of GDC‐3280 in human plasma and urine. The nonspecific binding associated with urine samples was overcome by the addition of CHAPS. The sample volume was 25 μL for either matrix, and supported liquid extraction was employed for analyte extraction. d6‐GDC‐3280 was used as the internal standard. Linear standard curves (R2 > 0.9956) were established from 5.00 to 5000 ng/mL in both matrices with quantitation extended to 50,000 ng/mL through dilution. In plasma matrix, the precision (RSD) ranged from 1.5 to 9.9% (intra‐run) and from 2.4 to 7.2% (inter‐run); the accuracy (RE) ranged from 96.1 to 107% (intra‐run) and from 96.7 to 104% (inter‐run). Similarly, in urine the precision was 1.5–6.2% (intra‐run) and 1.9–6.1% (inter‐run); the accuracy was 83.1–99.3% (intra‐run) and 87.1–98.3% (inter‐run). Good recovery (>94%) and negligible matrix effect were achieved in both matrices. Long‐term matrix stability was established for at least 703 days in plasma and 477 days in urine. Bench‐top stability of 25 h and five freeze–thaw cycles were also confirmed in both matrices. The method was successfully implemented in GDC‐3280's first‐in‐human trial for assessing its pharmacokinetic profiles.  相似文献   

11.
Aflatoxins AFB1, AFB2, AFG1, and AFG2 are toxic secondary metabolites produced by Aspergillus flavus and Aspergillus parasiticus and posses a potential threat to food safety. In the present work, liquid–liquid extraction and ultraperformance LC‐MS/MS method has been applied for the determination of four naturally occurring aflatoxins AFB1, AFB2, AFG1, and AFG2 in nonalcoholic beer. Aflatoxins extraction from nonalcoholic beer was carried out using liquid–liquid extraction procedure. The effects of solvent‐types were studied to obtain maximum recovery of the target analytes with minimum contamination. Among different solvents, the aflatoxins extraction was best achieved using ethyl acetate. The obtained recoveries were ranged from 85 to 96% with good quality parameters: LOD values between 0.001 and 0.003 ng/mL, linearity of the calibration curve (r2 > 0.999), and repeatability (run‐to‐run) and reproducibility (day‐to‐day) precisions with RSDs lower than 5% (n = 5) achieved at 0.50 ng/mL concentration. The optimized liquid–liquid extraction in combination with ultraperformance LC‐MS/MS was applied successfully to the analysis of AFB1, AFB2, AFG1, and AFG2 aflatoxins in 11 nonalcoholic beers and were detected up to 15.31 ng/L in some of the samples.  相似文献   

12.
This report describes the development and validation of a chromatography/tandem mass spectrometry method for the quantitative determination of pravastatin and its metabolite (3α‐hydroxy pravastatin) in plasma and urine of pregnant patients under treatment with pravastatin, as part of a clinical trial. The method includes a one‐step sample preparation by liquid–liquid extraction. The extraction recovery of the analytes ranged between 93.8 and 99.5% in plasma. The lower limits of quantitation of the analytes in plasma samples were 0.106 ng/mL for pravastatin and 0.105 ng/mL for 3α‐hydroxy pravastatin, while in urine samples they were 19.7 ng/mL for pravastatin and 2.00 ng/mL for 3α‐hydroxy pravastatin. The relative deviation of this method was <10% for intra‐ and interday assays in plasma and urine samples, and the accuracy ranged between 97.2 and 106% in plasma, and between 98.2 and 105% in urine. The method described in this report was successfully utilized for determining the pharmacokinetics of pravastatin in pregnant patients enrolled in a pilot clinical trial for prevention of preeclampsia. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated to determine the concentrations of 7‐hydroxymitragynine in rat plasma. Following a single‐step liquid–liquid extraction of plasma samples using chloroform, 7‐hydroxymitragynine and the internal standard (tryptoline) were separated on an Acquity UPLCTM BEH C18 (1.7 µm, 2.1 × 50 mm) column using an isocratic elution at a flow rate of 0.2 mL/min. The mobile phase consisted of 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile (10:90, v/v). The run time was 2.5 min. The analysis was carried out under the multiple reaction‐monitoring mode using positive electrospray ionization. Protonated ions [M + H]+ and their respective product ions were monitored at the following transitions: 415 → 190 for 7‐hydroxymitragynine and 173 → 144 for the internal standard. The calibration curve was linear over the range of 10–4000 ng/mL (r2 = 0.999) with a lower limit of quantification of 10 ng/mL. The extraction recoveries ranged from 62.0 to 67.3% at concentrations of 20, 600 and 3200 ng/mL). Intra‐ and inter‐day assay precisions (relative standard deviation) were <15% and the accuracy was within 96.5–104.0%. This validated method was successfully applied to quantify 7‐hydroxymitragynine in rat plasma following intravenous administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
The development of a simple and sensitive analytical approach that combines multiple monolithic fiber solid‐phase microextraction with liquid desorption followed by high‐performance liquid chromatography with diode array detection is proposed for the determination of trace levels of seven steroid sex hormones (estriol, 17β‐estradiol, testosterone, ethinylestradiol, estrone, progesterone and mestranol) in water and urine matrices. To extract the target analytes effectively, multiple monolithic fiber solid‐phase microextraction based on a polymeric ionic liquid was used to concentrate hormones. Several key extraction parameters including desorption solvent, extraction and desorption time, pH value and ionic strength in sample matrix were investigated in detail. Under the optimal experimental conditions, the limits of detection were found to be in the range of 0.027–0.12 μg/L. The linear range was 0.10–200 μg/L for 17β‐estradiol, 0.25–200 μg/L estriol, ethinylestradiol and estrone, and 0.50–200 μg/L for the other hormones. Satisfactory linearities were achieved for analytes with the correlation coefficients above 0.99. Acceptable method reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations of both less than 8%. The enrichment factors ranged from 54‐ to 74‐fold. Finally, the proposed method was successfully applied to the analysis of steroid sex hormones in environmental water samples and human urines with spiking recoveries ranged from 75.6 to 116%.  相似文献   

15.
The validation of a high throughput and specific method using a high‐performance liquid chromatography coupled to electrospray (ES+) ionization tandem triple quadrupole mass spectrometric (LC‐ESI‐MS/MS) method for ondansetron quantification in human plasma is described. Human plasma samples were extracted by liquid–liquid extraction (LLE) using methyl tert‐butyl ether and analyzed by LC‐ESI‐MS/MS. The limit of quantification was 0.2 ng/mL and the method was linear in the range 0.2–60 ng/mL. The intra‐assay precisions ranged from 1.6 to 7.7%, while inter‐assay precisions ranged from 2.1 to 5.1%. The intra‐assay accuracies ranged from 97.5 to 108.2%, and the inter‐assay accuracies ranged from 97.3 to 107.0%. The analytical method was applied to evaluate the relative bioavailability of two pharmaceutical formulations containing 8 mg of ondansetron each in 25 healthy volunteers using a randomized, two‐period crossover design. The geometric mean and respective 90% confidence interval (CI) of ondansetron test/reference percent ratios were 90.15% (81.74–99.44%) for Cmax and 93.11% (83.01–104.43%) for AUC0–t. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for Cmax and AUC0‐inf, it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of ondansetron. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A novel method for the analysis of (3‐hydroxypropyl)mercapturic acid (HPMA), a major acrolein metabolite in human urine incorporating a molecularly imprinted solid‐phase extraction (MISPE) process using N‐acetylcysteine ‐imprinted mesoporous silica particles coupled with LC‐MS/MS detection was developed. The molecularly imprinted mesoporous silica particles were synthesized based on the supported material of ordered mesoporous silica SBA‐15 with N‐acetylcysteine (NAC) as template using surface molecular imprinting technology. The condition of MISPE procedures was optimized. The use of MISPE improved the accuracy and precision of the LC‐MS method and lowered the limit of detection (0.23 ng/mL). The recoveries at three spiked levels ranged between 88.5% to 108.6%. The developed MISPE method enabled the selective extraction of HPMA successfully in human urine and could be used as an effective approach for the determination of ultra‐trace HPMA in complex biological matrices. The results in real samples showed that median levels of HPMA were significantly higher (1922.0 ng/mg of creatinine, N = 75) in smokers than in nonsmokers (759.1 ng/mg of creatinine, N = 5), demonstrating the higher acrolein uptake in smokers than in nonsmokers.  相似文献   

17.
The chromatograms obtained from the gas chromatography‐electron ionization mass spectrometric (GC‐EI‐MS) analysis of extracts containing G‐nerve agents in the presence of diesel, gasoline, etc., are dominated by hydrocarbon backgrounds that “mask” the G‐nerve agents, leading to severe difficulties in identification. This paper presents a practical solution for this challenge by transferring the G‐nerve agents from the organic phase into the aqueous phase using liquid‐liquid extraction (LLE), followed by derivatization with 2‐[(dimethylamino)methyl]phenol (2‐DMAMP), allowing ultrasensitive LC‐ESI‐MS/MS analysis of the G‐derivatives. The proposed approach enables rapid identification of trace amounts of G‐nerve agents with limits of identification (LOIs) at the pg/mL scale.  相似文献   

18.
The quantification of intracranial gefitinib (GEF) exposure is limited owing to the sensitivity of analytical equipment. Although mass spectrometry (MS) is the preferred method because of its high sensitivity, the equipment is not available in many laboratories, especially in developing Asian countries. In this paper, we developed a highly sensitive high performance liquid chromatography‐diode array detector (HPLC‐DAD) method for the assay of GEF in human cerebrospinal fluid (CSF) and plasma. GEF was extracted from CSF and plasma by solid‐phase extraction and liquid–liquid extraction, respectively. The chromatographic separation was performed on a C18 column with gradient elution of 0.1% triethylamine solution and acetonitrile, then finally detected at 344 nm. This method was validated and proved to be highly sensitive with a lower limit of quantitation value of 0.11 ng/mL in CSF and 11 ng/mL in plasma. The blood–brain barrier penetration ratio of GEF ranged from 1.48 to 2.41%. This method provides a reliable MS‐independent solution for the quantitation of GEF in patients’ CSF and plasma. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
Osthole, a major component isolated from the fruit of Cnidium monnieri (L.) Cusson, has been widely used in traditional Chinese medicine. We developed and validated a rapid and sensitive LC‐MS/MS method for the quantification of osthole in rat plasma. Sample preparation involved simple liquid–liquid extraction by ethyl acetate after addition of imperatorin as internal standard (IS). The analyte was separated using a C18 column with the mobile phase of methanol–0.1% formic acid (80:20, v/v) at a flow rate of 0.4 mL/min. The elutes were detected under positive electrospray ionization in multiple reaction monitoring mode. The method was sensitive with 0.5 ng/mL as the lower limit of detection. Good linearity was obtained over the range of 1.0–500.0 ng/mL. The intra and inter‐batch accuracy for osthole in rat plasma samples ranged from 99.5 to 108.1% and the variation was <8.9%. The stability, extraction efficiency and matrix effect were also acceptable. This method was successfully applied to the pharmacokinetic study of osthole in rat after intravenous and oral administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
An accurate and precise method for the quantification of 11‐nor‐Δ9‐tetrahydrocannabinol‐9‐carboxylic acid (THCA) in urine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) for doping analysis purposes has been developed. The method involves the use of only 200 µL of urine and the use of D9‐THCA as internal standard. No extraction procedure is used. The urine samples are hydrolysed using sodium hydroxide and diluted with a mixture of methanol/glacial acetic acid (1:1). Chromatographic separation is achieved using a C8 column with gradient elution. All MS and MS/MS parameters were optimised in both positive and negative electrospray ionisation modes. For the identification and the quantification of THCA three product ions are monitored in both ionisation modes. The method is linear over the studied range (5–40 ng/mL), with satisfactory intra‐and inter‐assay precision, and the relative standard deviations (RSDs) are lower than 15%. Good accuracy is achieved with bias less than 10% at all levels tested. No significant matrix effects are observed. The selectivity and specificity are satisfactory, and no interferences are detected. The LC/MS/MS method was applied for the analysis of 48 real urine samples previously analysed with a routine gas chromatography/mass spectrometry (GC/MS) method. A good correlation between the two methods was obtained (r2 > 0.98) with a slope close to 1. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号