共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper deals with the global reduction of axial flow fan noise in ducts in a building using a hybrid passive-active noise control method. The effectiveness of using an infra-red device as a reference signal source is also investigated. It is shown that using such a hybrid noise control system over an axial-flow fan reduces the overall sound pressure level by 5 dB(A) in the surrounding environment and global control of the blade passing frequency can also be achieved. This paper also shows that using an infra-red device as a reference signal source produces marginally better control as compared with using a microphone reference sensor. Moreover, long term stability is guaranteed and the possibility of acoustic feedback is eliminated. 相似文献
2.
Small axial-flow fans used for computer cooling and many other appliances feature a rotor driven by a downstream motor held by several cylindrical struts. This study focuses on the aerodynamic mechanism of rotor-strut interaction for an isolated fan. The three-dimensional, unsteady flow field is calculated using FLUENT, and the sound radiation predicted by acoustic analogy is compared with measurement data. Striking differences are found between the pressure oscillations in various parts of the structural surfaces during an interaction event. The suction surface of the blade experiences a sudden increase in pressure when the blade trailing edge sweeps past a strut, while the process of pressure decrease on the pressure side of the blade is rather gradual during the interaction. The contribution of the latter towards the total thrust force on the structure is cancelled out significantly by that on the strut. In terms of the acoustic contributions from the rotor and strut, the upstream rotor dominates and this feature differs from the usual rotor-stator interaction acoustics in which the downstream part is responsible for most of the noise. It is therefore argued that the dominant interaction mechanism is potential flow in nature. 相似文献
3.
4.
Active noise control systems have been applied to increase the insertion loss of noise barriers where the squared sound pressure or the total acoustic energy density is used as the cost function in previous works. The absolute value of the mean active sound intensity is chosen as the cost function to obtain extra sound insertion loss in the dark area of a hybrid active noise barrier system in this note. The strategy of minimizing the near-field sound intensity at discrete locations along the edge of the passive barrier is shown to be able to provide better far-field noise reduction than that of minimizing the squared sound pressure control. Both numerical simulations and off-line experiments are carried out with a three-channel demonstration system, where the locations of the secondary sources and the error sensors are optimized and comparisons are made between the extra sound pressure attenuation of the sound intensity control and that of the squared sound pressure control. 相似文献
5.
Current approaches to fan noise simulation are mainly based on the Lighthill equation and socalled aeroacoustic analogy, which are also based on the transformed Lighthill equation, such as the wellknown FW-H equation or the Kirchhoff theorem. A disadvantage of such methods leading to significant modeling errors is associated with incorrect solution of the decomposition problem, i.e., separation of acoustic and vortex (pseudosound) modes in the area of the oscillation source. In this paper, we propose a method for tonal noise simulation based on the mesh solution of the Helmholtz equation for the Fourier transform of pressure perturbation with boundary conditions in the form of the complex impedance. A noise source is placed on the surface surrounding each fan rotor. The acoustic fan power is determined by the acoustic-vortex method, which ensures more accurate decomposition and determination of the pressure pulsation amplitudes in the near field of the fan. 相似文献
6.
Sandra Velarde-Surez Rafael Ballesteros-Tajadura Jos Gonzlez Prez Bruno Pereiras-García 《Applied Acoustics》2009,70(11-12):1384-1392
In this work, the pressure fluctuation pattern in the volute of a squirrel-cage fan is analyzed. Also studied is how this pattern is modified when a slight geometry change is introduced in the volute tongue. The study has been carried out on a commercial machine, used in automotive air conditioning units. A three-dimensional and unsteady numerical simulation of the flow in the complete machine has been carried out using the commercial code FLUENT. In this way, the pressure fluctuations in some locations near the volute wall have been obtained. The results of this numerical simulation have been compared to the sound pressure level spectra radiated by the fan, measured in a ducted test installation at the laboratory. The tendencies of the sound pressure levels measured at the blade passing frequency show a good correlation with the amplitudes of pressure fluctuations obtained numerically near the volute wall. 相似文献
7.
Multichannel active control has been applied to the global reduction of tonal noise from a cooling fan. In order to achieve consistent far-field attenuation of multiple harmonics of the blade passage frequency (BPF) of the fan, an analytical model has been applied to the control system in order to determine appropriate transducer configurations. The results of the modeling show that the additional global reduction possible by locating acoustically compact secondary sources coplanar with a compact primary source rapidly lessens as the number of symmetrically placed sources is increased beyond three. Furthermore, the model suggests that there are locations in the extreme near field of the sources that can be considered ideal for the minimization of far-field radiated power. Experiments carried out show that a four-channel control system is more effective than a two-channel system at achieving far-field attenuations, especially at the higher harmonics of the BPF for the fan tested. In addition, greater far-field mean-square pressure attenuations are achieved with the error microphones located along the calculated ideal regions than for nonideal placement. 相似文献
8.
9.
The purpose of this work is to study computationally the possibility of the application of a hybrid active noise control technique for magnetic resonance imaging (MRI) acoustic noise reduction. A hybrid control system combined with both feedforward and feedback loops embedded is proposed for potential application on active MRI noise reduction. A set of computational simulation studies were performed. Sets of MRI acoustic noise emissions measured at the patient's left ear location were recorded and used in the simulation study. By comparing three different control systems, namely, the feedback, the feedforward and the hybrid control, our results revealed that the hybrid control system is the most effective. The hybrid control system achieved approximately a 20-dB reduction at the principal frequency component. We concluded that the proposed hybrid active control scheme could have a potential application for MRI scanner noise reduction. 相似文献
10.
针对传统FxLMS算法前馈自适应主动降噪耳机系统因果性条件不足时在宽带噪声环境中产生的高频噪声抬升问题,该文引入权重滤波误差信号FxLMS算法用于抑制高频噪声的抬升,但该算法带来了低频降噪量不足问题。因此,进一步提出将固定系数混合控制器与权重滤波误差信号FxLMS算法结合,在解决高频噪声抬升问题的同时,保证了良好的低频降噪量。基于DSP平台实现了提出的主动降噪耳机方案。实验证明,该方案针对宽带和单频等噪声都取得了较好的降噪效果。 相似文献
11.
Effect of inlet duct contour and lack thereof on the noise generated of an axial flow fan 总被引:1,自引:0,他引:1
This study concerns the unsteady flows in turbomachines in general, and the aeroacoustics of fans in particular. The principal objective of this paper is the determination of the influence of the upstream environment on the acoustic and aerodynamic behavior of axial fans. After analysis of the various sources of noise present in turbomachines, interest is focused on the influence of the disturbances of the velocity field at the suction. Accordingly, the effect of the presence of a contoured duct and a lack thereof at the inlet of an axial flow fan is analyzed . The results show the strong involvement of the upstream turbulence level in the generation of the noise, and in particular, of broadband noise. 相似文献
12.
13.
To analyze the complex three-dimensional flow structure of an axial flow fan and determine the validity of its application, PIV is used to provide detailed space and time resolved experimental data for understanding and control of flow field. The high resolution stereoscopic PIV system was successfully employed in this study for the investigation of flow structure around the axial flow fan. Using the once-per-revolution signal from the rotor, image fields were captured at a fixed position of the blades and hence provides the ability to do phase-averaging. The three-dimensional instantaneous velocity fields, phase-averaged velocity fields, instantaneous and mean vorticity distributions of the stereoscopic PIV measurement results were represented at typical planes of the flow field. Phaseaveraged velocity fields were calculated based on 200 frames of the instantaneous stereoscopic PIV measurement results. From the velocity distribution, the vorticity and turbulent intensity distribution, which are known to be major factors of fan noise, were calculated and its diffusion was discussed as they travel downstream. From the reconstructed three-dimensional velocity iso-surface at 8 cross planes of the outlet flow fields, the three-dimensional features can be seen clearly. 相似文献
14.
The feedback active noise control (ANC) can be seen as a predictor, the conventional method based on filtered-x least mean square (FXLMS) algorithm can only be useful for linear and tonal noise, but for nonlinear and broadband noise, it is useless. The feedback ANC using functional link artificial neural networks (FLANN) based on filtered-s least mean square (FSLMS) algorithm can reduce some nonlinear noise such as chaotic noise, but the noise cancellation performance is not very well, at the same time, it is not useful to random noise. To solve the problem above, a new feedback ANC using wavelet packet FXLMS (WPFXLMS) algorithm is proposed in this paper. By decomposing the broadband noise into several band-limited parts which are predictable and each part is controlled independently, the proposed algorithm can not only suppress the chaotic noise, but also mitigate the random noise. Compared with FXLMS and FSLMS algorithms, proposed WPFXLMS algorithm also holds the best performance on noise cancellation. Numerous simulations are conducted to demonstrate the effectiveness of the proposed WPFXLMS algorithm. 相似文献
15.
Reduction of the aerodynamic tonal noise of a forward-curved centrifugal fan by modification of the volute tongue geometry 总被引:1,自引:0,他引:1
Sandra Velarde-Suárez Carlos Santolaria-Morros Bruno Pereiras-García 《Applied Acoustics》2008,69(3):225-232
In this work, an experimental study about the influence of some geometric features on the aeroacoustic behaviour of a squirrel-cage fan, used in automotive air conditioning units, has been carried out. The study focused on the effect of both the shape and the position of the volute tongue on the noise generated by the fan. Different geometric configurations were tested in order to compare the results. First of all, the performance curves were measured in a standardized test facility. Then, the acoustic behaviour of the fan was characterized by means of acoustic pressure measurements near the fan inlet. The comparison of the test results indicated a great dependence of both the shape and the position of the volute tongue and the noise generation. In particular, some geometric configurations of the volute tongue were able to reduce the fan noise generation without reducing the fan operating range. 相似文献
16.
A Lattice Boltzmann method was employed to simulate active boundary layer flow control by means of a low-temperature surface
plasma. Plasma was generated by an AC input voltage over a surface electrode and an embedded electrode, resulting in an uneven
distribution of charges and an induced flow near the vicinity of the surface. Simulations were performed to examine the effect
of various geometrical parameters on the velocity flow profile and maximum velocity. 相似文献
17.
18.
In active noise control (ANC) systems, virtual microphones provide a means of projecting the zone of quiet away from the physical microphone to a remote location. To date, linear ANC algorithms, such as the filtered-x least mean square (FXLMS) algorithm, have been used with virtual sensing techniques. In this paper, a nonlinear ANC algorithm is developed for a virtual microphone by integrating the remote microphone technique with the filtered-s least mean square (FSLMS) algorithm. The proposed algorithm is evaluated experimentally in the cancellation of chaotic noise in a one-dimensional duct. The secondary paths evaluated experimentally exhibit non-minimum phase response and hence poor performance is obtained with the conventional FXLMS algorithm compared to the proposed FSLMS based algorithm. This is because the latter is capable of predicting the chaotic signal found in many physical processes responsible for noise. In addition, the proposed algorithm is shown to outperform the FXLMS based remote microphone technique under the causality constraint (when the propagation delay of the secondary path is greater than the primary path). A number of experimental results are presented in this paper to compare the performance of the FSLMS algorithm based virtual ANC algorithm with the FXLMS based virtual ANC algorithm. 相似文献
19.
Based on the analysis of active noise control system with multi-channel monopole secondary sources, a kind of compound secondary source is proposed in this paper. The proposed compound secondary source consists of two closely located monopole sources with their distance much smaller than a wavelength. The characteristics of the compound source are analyzed, and the performances of the active noise control system with the compound secondary sources on the monopole primary sound field and sound radiated by a plate are investigated both numerically and experimentally. It has been found that the proposed compound secondary sources control system can provide higher noise reduction for free field noise radiation control with the same number of control channels. It is shown that the better performance in noise reduction of the compound secondary sources control system is mainly due to the directivity of the secondary sources where the energy radiation pattern of the compound sources is similar to that of the primary sources. 相似文献
20.
Active Noise Control (ANC) problems are often affected by nonlinear effects, such as saturation and distortion of microphones and loudspeakers. Nonlinear models and specific adaptation algorithms must be employed to properly account for these effects. The nonlinear structure of the problem complicates the application of gradient-based Least Mean Squares (LMS) algorithms, due to the fact that exact gradient calculation requires executing nonlinear recursive filtering operations, which pose computational and stability issues. One favored solution to this problem consists in neglecting recursive terms in the gradient calculation, an approximation which is not always without consequences on the convergence performance. Besides, an efficient application of nonlinear models cannot avoid some form of model structure selection, to avoid the well-known effects of overparametrization and to reduce the computational load on-line. Unfortunately, the standard ANC setting configures an indirect identification problem, due to the presence of the secondary path in the control loop. In the nonlinear case, this destroys the linear regression structure of the problem even if the control filter is linear-in-the-parameters, thereby making it impossible to apply the many existing model selection methods for linear regression problems. A simple and computationally wise low demanding approach is here proposed for parameter estimation and model structure selection that provides an answer to the mentioned issues. The proposed method avoids altogether the use of the error gradient and relies on direct cost function evaluations. A virtualization scheme is used to assess the accuracy improvements when the model is subject to parametric or structural modifications, without directly affecting the control performance. Several simulation examples are discussed to show the effectiveness of the proposed algorithms. 相似文献