首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel approach for the determination of seven fungicides (metalaxyl-M, penconazole, folpet, diniconazole, propiconazole, difenoconazole and azoxystrobin) in wine samples is presented. Analytes were extracted from the matrix and transferred to a small volume of a high density, water insoluble solvent using solid-phase extraction (SPE) followed by dispersive liquid–liquid microextraction (DLLME). Variables affecting the performance of both steps were thoroughly investigated (metalaxyl-M was not included in some optimisation studies) and their effects on the selectivity and efficiency of the whole sample preparation process are discussed. Under optimised conditions, 20 mL of wine were first concentrated using a reversed-phase sorbent and then target compounds were eluted with 1 mL of acetone. This extract was mixed with 0.1 mL of 1,1,1-trichloroethane (CH3CCl3) and the blend added to 10 mL of ultrapure water. After centrifugation, an aliquot (1–2 μL) of the settled organic phase was analyzed by gas chromatography (GC) with electron capture (ECD) and mass spectrometry (MS) detection. The method provided enrichment factors (EFs) around 200 times and an improved selectivity in comparison to use of SPE as single sample preparation technique. Moreover, the yield of the global process was similar for red and white wine samples and the achieved limits of quantification (LOQs) (from 30 to 120 ng L−1 and from 40 to 250 ng L−1, for GC–ECD and GC–MS, respectively) were low enough for the determination of target species in commercial wines. Among compounds considered in this work, metalaxyl-M and azoxystrobin were found in several wines at concentrations from 0.8 to 32 ng mL−1.  相似文献   

2.
In this work, a reliable and selective procedure for the determination of thirteen fungicides in red and white wine samples is proposed. Solid-phase extraction (SPE) and liquid chromatography (LC) tandem mass spectrometry (MS/MS), based on a hybrid quadrupole time-of-flight (QTOF) system, were used as sample preparation and determination techniques, respectively. Extraction and purification of target analytes was carried out simultaneously by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Fungicides were determined operating the electrospray source in the positive ionization mode, with MS/MS conditions adjusted to obtain at least two intense product ions per compound, or registering two transitions per species when a single product was noticed. High selective MS/MS chromatograms were extracted using a mass window of 20 ppms for each product ion. Considering external calibration as quantification technique, the overall recoveries (accuracy) of the procedure ranged between 81% and 114% for red and white wine samples (10-20 mL), spiked at different concentrations between 5 and 100 ng mL(-1). Relative standard deviations of the above data stayed below 12% and the limits of quantification (LOQs) of the method, calculated for 10 mL of wine, varied between 0.1 ng mL(-1) for cyprodinil (CYP) and 0.7 ng mL(-1) for myclobutanil (MYC). The optimized method was applied to seventeen commercial wines produced in Spain and obtained from local supermarkets. Nine fungicides were determined, at levels above the LOQs of the method, in the above samples. The maximum concentrations and the highest occurrence frequencies corresponded to metalaxyl (MET) and iprovalicarb (IPR).  相似文献   

3.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed for the determination of 14 parent triazole fungicides and 8 of their metabolites found in apples, peaches, flour, raw water, and tap water. The triazole fungicides chosen for this multiresidue method development project included propiconazole, fenbuconazole and its RH-9129 and RH-9130 metabolites, cyproconazole, difenoconazole, tebuconazole and its HWG 2061 metabolite, hexaconazole, bromuconazole (both stereoisomers), epoxiconazole, tetraconazole, triticonazole and its RPA-404886 and RPA-406341 metabolites, triadimefon, triadimenol, and myclobutanil. Of special concern to the U.S. Environmental Protection Agency were the metabolites common to all triazole fungicides: free triazole, 1,2,4-triazole (T), and its 2 conjugates: triazolylalanine (TA) and triazolylacetic acid (TAA). These metabolites were the primary focus of this project. All samples we cleaned up by a combination of C18 solid-phase extraction (SPE), mixed-mode cationic SPE, and mixed-mode anionic SPE columns. A triple-stage quadrupole mass spectrometer, equipped with electrospray ionization in the positive-ion mode, was used to determine the compounds of interest. T, TA, and TAA were quantitated using isotopically labeled internal standards (IS), in which the 1,2,4-triazole ring had been synthesized by using 13C and 15N (IS_T, IS_TA, and IS_TAA). These isotopically labeled internal standards were necessary to correct for matrix effects. The T, TA, and TAA metabolites were quantitated at the 25-50 parts-per-billion (ppb) level in food commodities and at 0.50 ppb in water. Recoveries were 70-101% from apples, 60-121% from peaches, 57-118% from flour, 75-99% from raw water, and 79-99% from tap water.  相似文献   

4.
Metalaxyl-M and azoxystrobin have been used to control various fungal diseases on scallion and other crops. In view of the adverse toxic effects of both on the mammalian liver, it is necessary to conduct a cumulative risk assessment of their dietary exposure to consumers. The residues of metalaxyl-M and azoxystrobin on scallion were determined by a quick, easy, cheap, effective, rugged, and safe method (QuEChERS) combined with high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS). The half-lives were about 1.15 and 3.89 days, respectively, and the final residues after a seven-day harvest interval were <0.001–0.088 mg/kg and 0.190–4.687 mg/kg, respectively. The cumulative dietary risk quotient of the two fungicides to Chinese consumers calculated by the probability model is 13.94%~41.25%. According to the results of the contribution analysis, the risk posed by azoxystrobin is much greater than that of metalaxyl-M. Although metalaxyl-M and azoxystrobin do not pose a cumulative risk to Chinese consumers, the risk to children and adolescents is significantly higher than that to adults. This suggests that in future research, more consideration should be given to the cumulative risk of compounds to vulnerable groups.  相似文献   

5.
固相萃取-气相色谱/质谱法同时测定涂料中的8种有机锡   总被引:6,自引:0,他引:6  
建立了一种固相萃取(SPE)前处理、气相色谱-质谱(GC-MS)法同时测定涂料中8种有机锡的方法。样品采用阳离子交换固相萃取小柱净化,最佳固相萃取条件为:固相萃取小柱分别用5mL甲醇、7mL洗脱液(氯化铵、甲醇、冰乙酸的混合溶液)预洗,10mL甲醇活化;将用甲醇稀释的涂料样品上样后,用5mL甲醇淋洗,抽干2min,7mL乙酸-氯化铵甲醇溶液(10:90,V/V)洗脱溶液洗脱。洗脱液用四乙基硼化钠溶液衍生后,气相色谱-质谱法进行定性定量分析。结果表明:以标准加入法计算回收率,在1.68%-16.84%添加范围内,平均回收率在85%-105%之间,相对标准偏差均小于12%。  相似文献   

6.
Recently, a mixed-mode solid-phase extraction (SPE) procedure was developed for rapid extraction and cleanup for determination of the fungicides thiabendazole and carbendazim in various fruit juices. This paper reports the application of that sample preparation procedure to the liquid chromatographic/mass spectrometric determination of these fungicides in apple juice with detection by positive electrospray ionization mass spectrometry (ESI/MS). Response was linear for sample concentrations from 2 to 500 microg/L (ppb). Recoveries averaged 74% (9% RSD) for carbendazim and 93% (9% RSD) for thiabendazole. After SPE cleanup, no matrix supression was observed for the ESI+ response for either compound studied. The method was applied to the analysis of incurred residues in 4 store-bought apple juices; carbendazim levels ranged from 10 to 70 microg/L and thiabendazole levels ranged from less than 2 to 130 microg/L.  相似文献   

7.
A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction (PPT/SPE) procedure has been investigated. A mixture of acetonitrile and methanol along with formic acid was used to precipitate plasma proteins prior to selectively extracting the basic drug. After vortexing and centrifugation, the supernatants were directly loaded onto an unconditioned Oasis MCX microElution 96-well extraction plate, where the protonated drug was retained on the negatively charged sorbent while interfering neutral lipids, steroids or other endogenous materials were washed away. Normal wash steps were deemed unnecessary and not used before sample elution. The sample extracts were analyzed under both conventional and high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) conditions to examine the feasibility of the PPT/SPE procedure for human plasma sample clean-up. For the conventional LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 x 50 mm column with gradient elution (k' = 5.5). The mobile phase contained 0.1% formic acid in water and 0.1% formic acid in acetonitrile. For the high-speed LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 x 10 mm guard column with gradient elution (k' = 2.2, Rt = 0.26 min). The mobile phase contained 0.1% formic acid in water and 0.001% trifluoroacetic acid in acetonitrile. Detection for both conventional and high-speed LC/MS/MS methods was by positive ion electrospray tandem mass spectrometry on a ThermoElectron Finnigan TSQ Quantum Ultra, where enhanced resolution (RP 2000; 0.2 amu) was used for high-speed LC/MS/MS. The standard curve, ranging from 0.5 to 100 ng/mL, was fitted to a 1/x weighted quadratic regression model.This combined PPT/SPE procedure effectively eliminated time-consuming sorbent conditioning and wash steps, which are essential for a conventional mixed-mode SPE procedure, but retained the advantages of both PPT (removal of plasma proteins) and mixed-mode SPE (analyte selectivity). The validation results demonstrated that this PPT/SPE procedure was well suited for both conventional and high-speed LC/MS/MS analyses. In comparison with a conventional mixed-mode SPE procedure, the simplified PPT/SPE process provided comparable sample extract purity. This simple sample clean-up procedure can be applied to other basic compounds with minor modifications of PPT solvents.  相似文献   

8.
A liquid chromatography method using diode array-fluorescence detection and atmospheric pressure chemical ionization mass spectrometry (LC-DAD-FLD and LC–APCI-MS/MS) was developed to quantify the levels of tryptophan (TRP), kynurenine (KYN), kynurenic (KYNA) and xanthurenic (XA) acids in honey. This procedure involved isolating the compounds of interest via solid-phase extraction (SPE) with mixed-mode polymeric cartridges. Chromatographic separation of the analytes was performed in isocratic mode on a Synergi 4μ Hydro-RP 80Å (150 × 4.60 mm i.d.) analytical column at 30 °C. The mobile phase of 20 mM ammonium formate (pH 4) and methanol was passed at a flow rate of 0.5 mL/min. In replicate sets of spiked honey samples, the average analyte recoveries ranged from 60 to 98% for TRP, 55 to 120% for KYN, 65 to 106.5 for KYNA and 56 to 114% for XA. Detection limits ranged from 4 to 36 μg/kg for LC-DAD-FLD to 0.2 and 1.0 μg/kg for LC–APCI-MS/MS. A strong matrix effect was found when MS/MS was employed, necessitating calibration using the standard addition method on matrix-matched standards for each honey type. The method was used to quantify each of the compounds of interest in 17 honey samples of distinct botanical origins.  相似文献   

9.
This project evaluated solid-phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine the trace amount of rosiglitazone in human urine. The analytical performance of four modes of LC-MS and tandem MS operation (atmospheric pressure chemical ionization (APCI), electrospray ionization (ESI), positive and negative ionization) was compared for two mass spectrometers, a triple-quadrupole and a quadrupole ion trap instrument. Rosiglitazone was extracted from urine using a SPE cartridge of 50mg C8 sorbent and acetonitrile used as the eluting solvent. Samples were then separated on a RP18 column interfaced with a tandem mass spectrometer. The recovery of rosiglitazone was greater than 91.2%. The urine assay combining SPE and LC-APCI-MS/MS of triple-quadrupole was proved a very selective and sensitive method for determination of trace rosiglitazone. The assay was linear over a wide range, with a lower limit of quantification of 0.1 ng/mL using 1 mL of urine. The intra- and inter-day precisions were <9.8% and <7.9%, respectively, and the accuracies were in the range 91.0-103.6%. The rosiglitazone concentration profile in human urine was also determined. The results of this study reveal the adequacy of SPE-LC-APCI-MS/MS method for analyzing rosiglitazone from diabetic patients' urines. The concentrations of rosiglitazone were detected to range from 760 to 164 pg/mL.  相似文献   

10.
建立了同时测定全血、尿液和肝组织等生物样品中18种氨基甲酸酯类农药的在线固相萃取/液相色谱-线性离子阱质谱(On-line SPE/LC-LIT/MS)分析方法。样品经乙腈处理,稀释和离心后直接进样。经Waters OasisHLB在线SPE柱富集纯化,以BETASIL C18柱为分析柱,甲醇-水(均含0.1%甲酸)为流动相进行梯度洗脱;使用电喷雾电离(ESI)正离子模式测定,扫描方式为选择反应监测(SRM)和连续反应监测(CRM)。18种农药在考察的质量浓度范围内线性关系良好(权重因子1/X),相关系数为0.994 3~0.999 4;在全血和尿液中的检出限为0.1~5 ng/m L,在肝组织中的检出限为0.1~5 ng/g;3个加标水平的回收率为90.2%~114.5%,相对标准偏差(n=4)为0.5%~7.5%。该方法简单准确,灵敏度高,能够满足生物样品中18种氨基甲酸酯类农药的快速分析要求。  相似文献   

11.
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) is described for the separation and determination of six cytokinin nucleotides in coconut water. The best CZE separation for the six cytokinin nucleotide standards was achieved using a 25 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) methanol with an applied gradient separation voltage (25 kV for 32 min, and then a linear gradient to 30 kV in 5 min, finally 30 kV to the end of separation) in less than 60 min. MS/MS with multiple reaction monitoring (MRM) detection was carried out to obtain sufficient selectivity and sensitivity for the cytokinin nucleotides. The combined use of on-line sample stacking and CZE-MS/MS achieved limits of detection (LODs) in the range of 0.06-0.19 microM for the six cytokinin nucleotides at a signal-to-noise ratio of 3. Furthermore, a novel dual-step SPE procedure was developed for the pre-concentration and purification of cytokinin nucleotides using Oasis HLB and Oasis MAX cartridges. The recoveries of the cytokinin nucleotides after the dual-step SPE were in the range of 44-71%. The combination of off-line SPE, on-line sample stacking and CZE-MS/MS approach was successfully applied to screen for endogenous cytokinin nucleotides present in coconut water sample. trans-Zeatin riboside-5'-monophosphate (ZMP) was detected and quantified in coconut water by CZE-MS/MS after SPE and on-line sample stacking.  相似文献   

12.
A sensitive microElution solid-phase extraction (SPE) liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of M+4 stable isotope labeled cortisone and cortisol in human plasma. In this method, M+4 cortisone and M+4 cortisol were extracted from 0.3 mL of human plasma samples using a Waters Oasis HLB 96-well microElution SPE plate using 70 microL methanol as the elution solvent, and chromatographed on a Waters Symmetry C18 column (4.6 x 50 mm, 3.5 microm). M+9 cortisone and M+9 cortisol were used as the internal standards. A PE Sciex API 4000 tandem mass spectrometer interfaced with the liquid chromatograph via a turboionspray source was used for mass analysis and detection. The selected reaction monitoring (SRM) of precursor --> product ion transitions were monitored at m/z 365.2 [M+H](+) --> 167.0 and at m/z 367.3 [M+H](+) --> 125.1 for M+4 cortisone and M+4 cortisol, respectively. The lower limit of quantitation was 0.1 ng mL(-1) and the linear calibration range was from 0.1 to 100 ng mL(-1) for both analytes. This method demonstrated to be very reproducible and reliable.  相似文献   

13.
建立了蔬菜、水果中啶酰菌胺、氟啶酰菌胺、环氟菌胺、嘧菌胺、双炔酰菌胺和硅噻菌胺6种新型酰胺类杀菌剂残留量的液相色谱-串联质谱(liquid chromatography-tandem mass spectrometry, LC-MS/MS)检测方法。试样经乙腈提取、Florisil固相萃取柱净化、以乙腈和水为流动相梯度洗脱、结合新型核壳型填料色谱柱(Poroshell 120 EC-C18)分离,采用电喷雾正离子扫描、多反应监测模式质谱检测,外标法定量。结果表明:固相萃取结合新型色谱柱分离解决了酰胺类农药分析中基质效应强的难点问题。6种杀菌剂在0.5~100 μg/L范围内线性关系良好,相关系数(r)≥0.9990;对7种蔬菜及3种水果进行0.5、5和50 μg/kg 3个加标水平的回收试验,回收率为65%~124%,相对标准偏差(RSD, n=5)为1%~18%; 6种杀菌剂的方法检出限(S/N≥3)为0.10~0.17 μg/kg。该净化、分离模式显著降低了蔬菜、水果中6种新型酰胺类农药的基质效应,方法简单准确,可满足蔬菜和水果中啶酰菌胺等6种新型酰胺类杀菌剂残留检测的要求。  相似文献   

14.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

15.
建立了采用固相萃取-液相色谱-串联质谱同时测定麦冬、玄参、延胡索中7种甲氧基丙烯酸酯类杀菌剂残留量的方法。样品经乙酸乙酯提取,氨基固相萃取柱净化后,经C18色谱柱分离,以甲醇和1.0‰甲酸溶液为流动相梯度洗脱,电喷雾正离子模式离子化,选择反应监测方式监测,串联质谱测定,外标法定量。结果显示,各目标物在1或2个数量级浓度范围内的线性关系良好,相关系数均大于0.996。醚菌胺、啶氧菌酯和肟菌酯的定量限为2 μg/kg,嘧菌酯和吡唑醚菌酯的定量限为4 μg/kg, Z-苯氧菌胺和醚菌酯的定量限为10 μg/kg。各杀菌剂的回收率为60.4%~110%,相对标准偏差为1.2%~17%。该方法能满足麦冬、玄参、延胡索中7种目标杀菌剂残留量的检测。  相似文献   

16.
Xu Q  Wang M  Yu S  Tao Q  Tang M 《The Analyst》2011,136(23):5030-5037
A simple, rapid and sensitive method for the determination of diethylstilbestrol (DES), dienestrol (DE) and hexestrol (HEX) was developed by using the Nylon 6 nanofibers mat-based solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS). These estrogens were separated within 8 min by LC using an ODS column and methanol/water (80/20, v/v) at a flow rate of 1.0 mL min(-1). Electrospray ionization conditions in the negative ion mode were optimized for MS detection of the estrogens. Under the optimum SPE conditions, all target analytes in 50 mL environmental water samples can be completely extracted by 1.5 mg Nylon 6 nanofibers mat at flow rate of 3.0 mL min(-1) and easily eluted by passage of 500 μL mobile phase. By using the novel SPE-LC/MS method, good linearity of the calibration curve (r(2) ≥ 0.9992) was obtained in the concentration range from 0.10 ng L(-1) to 1.0 mg L(-1) (except for DE which was 0.20 ng L(-1) to 1.0 mg L(-1)) for all analytes examined. The limits of detection (S/N = 3) of the three estrogens ranged from 0.05 ng L(-1) to 0.10 ng L(-1). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several water samples were collected from Jinchuan River and Xuanwu Lake, and in Jinchuan River water DES was detected at 0.13 ng L(-1). The recoveries of estrogens spiked into tap water were above 98.2%, and the relative standard deviations were below 4.78%.  相似文献   

17.
An original analytical method has been developed for the determination of the antioxidants trans-resveratrol (t-RSV) and cis-resveratrol (c-RSV) and of melatonin (MLT) in red and white wine. The method is based on HPLC coupled to fluorescence detection. Separation was obtained by using a RP column (C8, 150 mm x 4.6 mm id, 5 mum) and a mobile phase composed of 79% aqueous phosphate buffer at pH 3.0 and 21% ACN. Fluorescence intensity was monitored at lambda = 386 nm while exciting at lambda = 298 nm, mirtazapine was used as the internal standard. A careful pretreatment of wine samples was developed, using SPE with C18 cartridges (100 mg, 1 mL). The calibration curves were linear over the following concentration ranges: 0.03-5.00 ng/mL for MLT, 3-500 ng/mL for t-RSV and 1-150 ng/mL for c-RSV. The LOD values were 0.01 ng/mL for MLT, 1 ng/mL for t-RSV and 0.3 ng/mL for c-RSV. Precision data, as well as extraction yield and sample purification results, were satisfactory. Thus, the method seems to be suitable for the analysis of MLT and resveratrol isomers in wine samples. Moreover, wine total polyphenol content and antioxidant activity were evaluated.  相似文献   

18.
A rapid and high-throughput isotope dilution LC-MS/MS method with online sample pre-concentration and clean-up using anionic mixed-mode SPE was described for the determination of closantel and rafoxanide in edible bovine and ovine tissues. Tissue samples were extracted with acetonitrile and acetone mixture (60:40, v/v). Sample pre-concentration, clean-up and analysis were completed simultaneously with the online MAX SPE LC-MS/MS system. Closantel-(13) C(6) and rafoxanide-(13) C(6) were used as the internal standards to improve the precision of the method. The method was validated with edible ovine and bovine tissues (muscle, kidney and liver) fortified at three different levels. The accuracy and RSD were 86-106% and ≤14%, respectively. This high-throughput method was suitable for routine quantitative analysis of closantel and rafoxanide in food safety surveillance samples.  相似文献   

19.
A multiresidue method is developed for the screening, quantification and confirmation of 43 pesticides, belonging to different chemical families of insecticides, acaricides, fungicides, herbicides and plant growth regulators, and 9 pesticide metabolites in four fruit and vegetable matrices. Pesticide residues are extracted from the samples with MeOH:H2O (80:20, v/v) 0.1% HCOOH, and then a cleanup step using OASIS HLB SPE cartridges is applied. The SPE eluate is concentrated and the final volume adjusted to 1 mL with MeOH:H2O (10:90, v/v) before injection into LC-MS/MS. Analyses are performed using electrospray ionization (ESI) and triple quadrupole (QqQ) analyzer. The method has been validated based on the SANCO European Guidelines for representative samples that were chosen to study the influence of different matrices: high water content (tomato), high acidic content (lemon), high sugar content (raisin) and high lipidic content (avocado). Special attention has been given to minimize the degradation of some pesticides into their metabolites and the losses observed in the evaporation step. Under the optimized conditions, the recoveries were, with a few exceptions, in the range 70-110% with satisfactory precision (CV < or = 15%). The quantification of analytes was carried out using the most sensitive transition for every compound and by "matrix-matched" standards calibration. The method can be used for the accurate determination of 52 pesticides and metabolites in one single determination step at the 0.01 mg/kg level. Confirmation of residues detected in samples is performed by an independent injection into the LC-MS/MS system by acquiring additional MS/MS transitions to that used for quantification. The acquisition of the highest number of available transitions is suggested for unequivocal confirmation of the analyte.  相似文献   

20.
Rapid screening of clenbuterol in urine was performed by combining desorption electrospray ionization (DESI) and tandem mass spectrometry (MS/MS). Optimization experiments were carried out including the selection of substrates, spray solutions, nebulizing gas pressures, high-voltage power supplies and flow rates of spray solution. The limit of detection (LOD), defined as the lowest quantity that can be detected, was 5.0 pg for the pure compound. Using DESI coupled with solid-phase extraction (SPE), the linear response range was from 10 to 400 ng/mL (R(2) = 0.993) and the concentration LOD for urine sample was 2.0 ng/mL. The analysis for one spiked urine sample was achieved within 4 min. In addition to the fast analysis speed, MS/MS provided structural information for the confirmation of clenbuterol. Urine samples from different people were investigated and the recoveries were within 100 +/- 20%. The developed method can potentially be used for screening of clenbuterol in doping control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号