首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of fingolimod in human blood. The analyte and internal standard fingolimod-d4 were extracted from 300 μl of human blood using protein precipitation coupled with solid-phase extraction method. The chromatographic separation was achieved with a Kinetex biphenyl column (100 × 4.6 mm, 2.6 μm) under isocratic conditions at the flow rate of 0.8 ml/min and column temperature was maintained at 45°C. The detection of analyte and internal standard was carried out by tandem mass spectrometry, operated in positive ion and multiple reaction monitoring acquisition mode. The method was fully validated for its selectivity, precision, accuracy, linearity, stability, detection and quantification limit. The extraction recovery of fingolimod in human blood ranged from 98.39 to 99.54%. The developed method was linear over the concentration range of 5–2500 pg/ml with a detection limit of 1 pg/ml. The developed method was validated and successfully applied for pharmacokinetic study after oral administration of fingolimod capsules.  相似文献   

2.
FIM protein, which consists of 155 amino acids, was developed as a novel GLP-1 analog to reduce blood glucose, and pharmacodynamic results showed that it had a certain effect when used in treating Alzheimer's disease. The molecular weight of FIM is 16,304 Da. In theory, the concentration of FIM in biological samples should be determined by the ligand binding assay method or indirectly quantified using LC–MS/MS instrumentation. However, the above methods are complex and time-consuming. In this study, we successfully developed a simpler LC–MS/MS method for directly quantifying the intact FIM protein in monkey plasma for the first time. The chromatographic separation of FIM was achieved using an InertSustain Bio C18 column with a mobile phase of acetonitrile containing 0.1% formic acid (A)–water containing 0.1% formic acid (B) at a flow rate of 0.3 ml/min. Good linearity was observed in the concentration range of 5–500 ng/ml (r2 > 0.99). The intra- and inter-day precisions (expressed as relative standard deviation, RSD) of FIM were 2.30–12.8 and 7.30–13.2%, respectively. The intra- and inter-day accuracies (expressed as a relative error, RE) were −12.7–6.55 and − 10.1–0.892%, respectively. This method was successfully applied for a pharmacokinetic study of the FIM protein in four monkeys after subcutaneous administration.  相似文献   

3.
The first liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous quantification of p-aminohippuric acid and inulin, both typical biomarkers of kidney function. 5-(Hydroxymethyl)furfural, generated from inulin by acid and heat preparation, was used as an inulin substitute for the quantification. Acetaminophen was used as the internal standard. Solid-phase extraction was carried out with 5% methanol as the washing solution to optimize the retention of the analytes and to avoid obstruction of the orifice plate of the mass spectrometer caused by any unreacted inulin residue remaining from the sample preparation process. Chromatography separation was performed on a Symmetry C18 column and a mobile phase composed of 2 mM ammonium formate and 0.1% formic acid in water (solvent A) and 2 mM ammonium formate and 0.1% formic acid in acetonitrile (solvent B) (30:70, v/v). Detection was performed with a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization in the multiple reaction monitoring mode. The selected transitions were m/z 195.2 → 120.2, 127.1 → 109.1, and 152.1 → 110.0 for p-aminohippuric acid, inulin [measured as 5-(hydroxymethyl)furfural], and acetaminophen, respectively. The linearity ranged from 10 to 140 μg/mL and from 100 to 1,400 μg/mL for p-aminohippurric acid and inulin (r > 0.99), respectively. The precisions and accuracies were all within 12 and 11% for the lower limit of quantification and quality control samples, respectively. This application was proven to be reliable and accurate and was successfully applied to a renal function study.  相似文献   

4.
A rapid, sensitive, and selective liquid chromatography–tandem mass spectrometry method for the detection of tandospirone in human plasma is described. It was employed in a pharmacokinetic study. The analyte and internal standard diphenhydramine were extracted from plasma using liquid–liquid extraction, then separated on a Zorbax XDB C18 column using a mobile phase of methanol–water–formic acid (80:20:0.5, v/v/v). The detection was performed with a tandem mass spectrometer equipped with an electrospray ionization source. Linearity was established in the concentration range of 10.0-5,000 pg/ml. The lower limit of quantification was 10.0 pg/ml. The intraday and interday relative standard deviation across three validation runs over the entire concentration range was less than 13%. Accuracy determined at three concentrations (25.0, 200, and 4,000 pg/ml for tandospirone) ranged from 94.4 to 102.1%. Each plasma sample was chromatographed within 3.4 min. The method proved to be highly selective and suitable for bioequivalence evaluation of different formulations containing tandospirone and clinical pharmacokinetic investigation of tandospirone.  相似文献   

5.
A rapid, selective and sensitive ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was developed to detect meloxicam in human plasma. A triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source was used in positive ion mode. Protein precipitation with acetonitrile was used for sample preparation. Meloxicam and 13C6-meloxicam internal standard were analyzed on an Acquity CSH C18 column with a mobile phase of acetonitrile and water in 0.1% formic acid using a gradient program for separation. The retention time of meloxicam was 1.1 min and the total run time was only 2.0 min. Detection was performed in multiple reaction monitoring mode using an electrospray ionization source with optimized mass spectrometry parameters. The calibration curves were linear in the range 10.0–3.00 × 103 ng/ml (r ≥ 0.99). The within-run and between-run RSDs were ≤14.8%. The within-run and between-run REs ranged from −4.6 to 10.7%. There was no significant matrix effect, and the recovery rate was high. This method was fully validated, including reinjection reproducibility in human plasma. The method was applied to the pharmacokinetic study. All of the incurred sample reanalysis methods met the criteria.  相似文献   

6.
A new, sensitive and fast method for the simultaneous determination of pyrazinamide, isoniazid, streptomycin, ethambutol, and rifampicin in human plasma was developed and validated. The method required only 100 μL of plasma and one step for sample preparation by protein precipitation. The drugs were separated by using a hydrophilic interaction liquid chromatography (HILIC) column. The mobile phase was methanol and water (0.1 % formic acid and 5 mM ammonium acetate, pH 3.0?±?0.1) in a ratio of 65:35 (v/v), which was eluted at an isocratic flow rate of 0.5 mL/min. Tandem mass spectrometry was performed with a triple-quadrupole tandem mass spectrometer. By use of the HILIC column, the detection was free of ion-pair reagents in the mobile phase, with no significant matrix effects. The total run time was less than 2 min for each sample. The method was validated by evaluating its selectivity, sensitivity, linearity, accuracy, and precision according to US Food and Drug Administration guidelines. The lower limit of quantification was 4.0 ng/mL for pyrazinamide, isoniazid, and rifampicin, 0.5 ng/mL for ethambutol, and 10.0 ng/mL for streptomycin. The intraday precision and interday precision were less than 9 %, with the accuracy ranging between ?9.3 and 7.3 %. The method was successfully applied to therapeutic drug monitoring of 33 patients with tuberculosis after administration of standard antituberculosis drugs. The method has been proved to meet the high-throughput requirements in therapeutic drug monitoring.
Scatter plots of 2-h plasma drug concentration of patients after receiving a standard medication. (The lower line and the upper line represent the low and high levels of the expected plasma concentrations of the antituberculosis drugs in tuberculosis patients. Open triangles female, age 0–20 years; closed triangles male, age 0–20 years; open diamonds female, age 21–40 years; closed diamonds male, age 21–40 years; open squares female, age 41–60 years; closed squares male, age 41–60; open circles female, age 61–80 years; closed circles male, age 61–80 years)  相似文献   

7.
A novel method for identification and quantification of microcystin-RR (MC-RR) and its metabolites (MC-RR-GSH and MC-RR-Cys) in the fish liver was developed and validated. These analytes were simultaneously extracted from fish liver using water containing EDTA with 5% acetic acid, followed by a mixed-mode cation-exchange SPE (Oasis MCX) and subsequently determined by liquid chromatography–electrospray ionization ion trap mass spectrometry (LC–ESI-ITMS). Extraction parameters including volume and pH of eluting solvents, were optimized. Best recoveries were obtained by using 10 mL of 15% ammonia solution in methanol. The mean recoveries at three concentrations (0.2, 1.0, and 5.0 μg g−1 dry weight [DW]) for MC-RR, MC-RR-GSH and MC-RR-Cys were 93.6–99%, 68.1–73.6% and 90.0–95.2%, respectively. Method detection limit (MDL) were 4, 7 and 5 ng g−1 DW for MC-RR, MC-RR-GSH and MC-RR-Cys, respectively. Limits of quantification (LOQs) for MC-RR, MC-RR-GSH and MC-RR-Cys were calculated to be 10, 18 and 13 ng g−1 DW, respectively. Finally, this method was successfully applied to the identification and quantification of MC-RR, MC-RR-GSH and MC-RR-Cys in the liver of bighead carp with acute exposure of MCs.  相似文献   

8.
There is substantial evidence that circulating estrogens promote the proliferation of breast cancer. Consequently, adjuvant hormonal treatment strategies targeting estrogen action have been established. Such hormonal therapies include selective estrogen receptor modulators, such as tamoxifen, which interfere at the estrogen receptors directly, or non-steroidal aromatase inhibitors, such as anastrozole and letrozole, which inhibit estrogen synthesis through blocking the aromatase, a key enzyme of estrogen production. Despite considerable therapeutic success, in several cases, the use of these drugs is limited by side effects that have been described to significantly impair the adherence of patients to endocrine treatment. However, objective data concerning patient adherence and its clinical relevance are limited. One promising approach to check patient-reported adherence is drug monitoring in human plasma. Therefore, a liquid chromatography–tandem mass spectrometry method to determine the plasma concentrations of tamoxifen, anastrozole, and letrozole has been developed and fully validated according to guidelines for clinical and forensic toxicology. The validation criteria evaluated were selectivity, linearity, accuracy and precision, limit of quantification, recovery and matrix effects, sample stability, and carryover. The six-point calibration curves showed linearity over the range of concentrations from 25 to 500 ng/ml for tamoxifen, 5 to 200 ng/ml for anastrozole, and 10 to 300 ng/ml for letrozole. The intra- and inter-day precision and accuracies were always better than 15%. The validated procedure was successfully applied to a clinical study (Patient-Reported Outcomes in Breast Cancer Patients undergoing Endocrine Therapy, PRO-BETh). A major aim of PRO-BETh study is the comprehensive evaluation of adherence to treatment in pre- and post-menopausal women with breast cancer. Plasma samples of 310 breast cancer patients undergoing anti-estrogen therapy were analyzed. Eight samples did not contain a quantifiable amount of drug, strongly indicating non-adherence of the corresponding patients to adjuvant breast cancer treatment. Furthermore, plasma concentrations at the lower end of the observed plasma level distribution might represent a hint but not a confirmation for non-adherence in terms of non-daily and irregular intake of the prescribed drug.  相似文献   

9.
A sensitive and specific method for the quantitative determination of zearalenone (ZEN) and its major metabolites (α-zearalenol (α-ZEL), β-zearalenol (β-ZEL), α-zearalanol (α-ZAL), β-zearalanol (β-ZAL) and zearalanone (ZAN)) in animal plasma using liquid chromatography combined with heated electrospray ionization (h-ESI) tandem mass spectrometry (LC–MS/MS) and high-resolution Orbitrap® mass spectrometry ((U)HPLC–HR–MS) is presented. The sample preparation was straightforward, and consisted of a deproteinization step using acetonitrile. Chromatography was performed on a Hypersil Gold column (50 mm × 2.1 mm i.d., dp: 1.9 μm, run-time: 10 min) using 0.01% acetic acid in water (A) and acetonitrile (B) as mobile phases.  相似文献   

10.
Because norcantharidin (NCTD) is unstable and subject to ring opening and hydrolysis, the diacid metabolite of norcantharidin (DM-NCTD) is the stable form of NCTD found in normal saline solution. Conversion of NCTD to DM-NCTD is almost 100 %, making it possible to determine and investigate the pharmacokinetics of DM-NCTD converted from NCTD. In this paper, a sensitive, simple and selective liquid chromatographic–tandem mass spectrometric method was developed and validated for determination of DM-NCTD in beagle plasma. DM-NCTD was detected in multiple-reaction monitoring (MRM) mode by using the dehydrated ion 169.3 as precursor ion and its product ion 123.1 as the detected ion. Ribavirin was used as internal standard and detected in MRM mode by use of precursor ions, resulting in a product ion transition of m/z 267.1?→?135.1. This method was successfully used for a pharmacokinetic study of DM-NCTD in beagles after intravenous administration of DM-NCTD in normal saline solution at doses of 0.39, 0.78, and 1.6 mg kg?1. DM-NCTD had dose-dependent kinetics across the dosage range investigated, with enhanced T 1/2α and AUC0-12 and apparently decreasing V d and CL with increasing dosage. After single-dose administration, T 1/2α ranged from 0.20 to 0.55 h, AUC0-12 from 1.81 to 43.6 μg mL?1 h?1, V d from 228 to 55.9 mL kg?1, and CL from 220 to 36.5 mL kg?1 h?1 (P?<?0.01). The results indicated nonlinear pharmacokinetic behavior of DM-NCTD in beagles, suggesting that the risk of DM-NCTD in normal saline solution intoxication may be non-proportionally increased at higher doses.
Figure
Determination and pharmacokinetic study of the diacid metabolite of norcantharidin  相似文献   

11.
This work describes a liquid chromatography–electrospray tandem mass spectrometry method for detection of desmopressin in human plasma in the low femtomolar range. Desmopressin is a synthetic analogue of the antidiuretic hormone arginine vasopressin and it might be used by athletes as a masking agent in the framework of blood passport controls. Therefore, it was recently added by the World Anti-Doping Agency to the list of prohibited substances in sport as a masking agent. Mass spectrometry characterization of desmopressin was performed with a high-resolution Orbitrap-based mass spectrometer. Detection of the peptide in the biological matrix was achieved using a triple-quadrupole instrument with an electrospray ionization interface after protein precipitation, weak cation solid-phase extraction and high performance liquid chromatography separation with an octadecyl reverse-phase column. Identification of desmopressin was performed using three product ions, m/z 328.0, m/z 120.0, and m/z 214.0, from the parent ion, m/z 535.5. The extraction efficiency of the method at the limit of detection was estimated as 40% (n = 10), the ion suppression as 5% (n = 10), and the limit of detection was 50 pg/ml (signal-to-noise ratio greater than 3). The selectivity of the method was verified against several endogenous and synthetic desmopressin-related peptides. The performance and the applicability of the method were tested by analysis of clinical samples after administration of desmopressin via intravenous, oral, and intranasal routes. Only after intravenous administration could desmopressin be successfully detected.  相似文献   

12.
Dabigatran etexilate mesylate (DABE), a prodrug, quickly changes into dabigatran (DAB) after its oral administration. Accordingly, detecting DABE in plasma is practically unmanageable. An ultraperformance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) technique was developed and validated to compute free DAB in participants. For the first time, the central composite design, a type of response surface methodology, was applied for optimizing variables affecting the cleavage of glucuronide bond. In addition, the pharmacokinetic parameters of generic medication (okanadab) were determined, and the obtained outcomes were compared with those of the branded drug (pradaxa). The sample preparation was done using methanol as a protein precipitant and the separation was achieved using an ACQUITY UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm). The elution was isocratically conducted using 10 mM ammonium formate:methanol (72:28, v/v) as a mobile phase and the flow rate was 0.25 mL/min. Multiple reaction monitoring and positive electrospray ionization were used. The determination was performed within 1 min, and the calibration growth curve was established over a range of 1.19–475 ng/mL using DAB-d3 as a tagged internal standard. Bioequivalence research was validated following the US Food and Drug Administration (US FDA) guidelines for bioanalytical procedures and acceptable outcomes were achieved. The outcomes for okanadab and pradaxa did not differ significantly.  相似文献   

13.
Penindolone (PND) is a novel influenza A virus dual inhibitor that blocks hemagglutinin-mediated adsorption and membrane fusion. A sensitive and specific ultra-performance liquid chromatography–tandem mass spectrometry method was developed and validated to determine PND in rat plasma. Plasma sample preparation was a simple deproteinization with acetonitrile followed by centrifugation. Chromatographic separation was performed on a C18 column with a gradient mobile phase of acetonitrile–water containing 0.1% formic acid. Detection was carried out by electrospray ionization in negative ion multiple reaction monitoring mode. Linear detection responses were obtained for PND ranging from 1 to 1,000 ng/ml. The intra- and inter-day precision (relative standard deviations, RSD) were within 6.5%, and accuracy (relative error, RE) was within ±11.0%. The extraction recovery data for PND and internal standard (IS) were >96.0%. PND was proved to be stable during the sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic and bioavailability studies for PND in rats. The results showed the existence of twin peaks, gender difference and nonlinear pharmacokinetics for PND. In addition, two oxidation metabolites and three glucuronidation metabolites of PND were detected by ultra-high-performance liquid chromatography–high resolution mass spectrometry.  相似文献   

14.
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 μm, 50 mm × 2.1 mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0–103.4%, with the RSD < 15%. The calibration curves for alkylphenols were linear within the range of 0.01–0.4 μg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 μg/kg.  相似文献   

15.
This paper describes the development and validation of an analytical methodology to determine eight perfluorinated compounds (PFCs) in edible fish using pressurized liquid extraction (PLE) with water and solid-phase extraction (SPE) with an ion-exchanger as extraction and pre-concentration procedures, followed by liquid chromatography–quadrupole-linear ion trap mass spectrometry (LC–QqLIT–MS). The rapidity and effectiveness of the proposed extraction procedure were compared with those most commonly used to isolate PFCs from fish (ion-pairing and alkaline digestion). The average recoveries of the different fish samples, spiked with the eight PFCs at three levels (the LOQ, 10 and 100 μg kg−1 of each PFC), were always higher than 85% with relative standard deviation (RSD) lower than 17%. A good linearity was established for the eight PFCs in the range from 0.003–0.05 to 100 μg kg−1, with r > 0.9994. The limits of quantification (LOQs) were between 0.003 and 0.05 μg kg−1, which are well below those previously reported for this type of samples. Compared with previous methods, sample preparation time and/or LOQs are reduced. The method demonstrated its successful application for the analysis of different parts of several fish species. Most of the samples tested positive, mainly for perfluoropentanoic acid (PFPA), perfluorobutane sulfonate (PFBS) and perfluorooctanoic acid (PFOA) but other of the eight studied PFCs were also present.  相似文献   

16.
This study used reversed-phase liquid chromatography–tandem mass spectrometry and supercritical fluid chromatography–tandem mass spectrometry for determination of the stereoisomers of chlorfenvinphos and dimethylvinphos in tobacco. Tobacco samples were extracted and purified with a modified quick, easy, cheap, effective, rugged, and safe technique using spherical carbon. The performance of both methodologies was comprehensively compared in terms of methods validation parameters (separation efficiency, linearity, selectivity, recovery, repeatability, sensitivity, matrix effect, etc.). Under optimized conditions, the calibration curves of the stereoisomers of chlorfenvinphos and dimethylvinphos in the range of 10–500 ng/mL showed excellent linearity with R2 ≥ 0.997 in both methods. The adequate recoveries of analytes from three different spiked tobaccos were obtained using reversed-phase liquid chromatography–tandem mass spectrometry (86.1–95.7%) as well as supercritical fluid chromatography–tandem mass spectrometry (86.5–94.0%). The relative standard deviations for spiked samples were all below 7.0%. Compared with supercritical fluid chromatography–tandem mass spectrometry, lower matrix effects and LODs can be obtained in reversed-phase liquid chromatography–tandem mass spectrometry.  相似文献   

17.
A simple LC–tandem mass spectrometry (MS/MS) method to determine ebastine and carebastine (active metabolite) in human plasma was developed and validated. Analytes and internal standards were precipitated by protein precipitation and separated on Synergi Hydro-RP 80A column (4 μm, 50 mm × 2.0 mm; Phenomenex) by gradient elution with mobile phase A comprising 0.1% formic acid in 5 mm ammonium acetate (NH4Ac) and B comprising 100% methanol at a flow rate 0.4 mL/min. Ions were detected in positive multiple reaction monitoring mode, and they exhibited linearity over concentration range 0.01–8.0 and 1.00–300 ng/mL for ebastine and carebastine, respectively. A clinical pharmacokinetic study was conducted in healthy Chinese volunteers under fasting and fed conditions after a single oral administration of 10 mg ebastine. The maximum plasma concentration (Cmax), time to Cmax (Tmax) and elimination half-life for ebastine were 0.679 ± 0.762 ng/mL, 1.67 ± 1.43 h and 7.86 ± 6.18 h, respectively, whereas these for carebastine were 143 ± 68.4 ng/mL, 5.00 ± 2.00 h and 17.4 ± 4.97 h, respectively under fasting conditions; the corresponding values under fed conditions were 4.13 ± 2.53 ng/mL, 3.18 ± 1.09 h and 21.6 ± 7.77 h for ebastine and 176 ± 68.4 ng/mL, 6.14 ± 2.0 h and 20.0 ± 4.97 h for carebastine.  相似文献   

18.
A sensitive and robust liquid chromatography–tandem mass spectrometry (LC-MS/MS) method allowing the rapid screening and confirmation of thyreostatic drugs in bovine blood plasma was developed and validated according to Commission Decision 2002/657/EC, chapter 3.1.3 “alternative validation”, by applying a matrix-comprehensive in-house validation concept. Decision limit CCα, detection capability CCβ, recovery, repeatability, within-laboratory reproducibility and the uncertainty of measurement were calculated. Furthermore, a factorial effect analysis was carried out to identify factors that have a significant influence on the method. Factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and duration of sample preparation) were systematically varied on two levels during the validation study. Subsequently, the extent to which these factors influence the measurement results of the individual analytes was examined.  相似文献   

19.
To evaluate the potential relationship between cancer and polyamine metabolome, a UHPLC–MS/MS method has been developed and validated for simultaneous determination of polyamine precursors, polyamines, polyamine catabolite in human plasma and urine. Polyamine precursors including l-ornithine, lysine, l-arginine and S-adenosyl-l-methionine; polyamines including 1,3-diaminopropane, putrescine, cadaverine, spermidine, spermine, agmatine, N-acetylputrescine, N-acetylspermine and N-acetylspermidine; polyamine catabolite including γ-aminobutyric acid had been determined. The analytes were extracted from plasma and urine samples by protein precipitation procedure, and then separated on a Shim-pack XR-ODS column with 0.05% heptafluorobutyric acid (HFBA) in methanol and 0.05% HFBA in water. The detection was performed on UHPLC–MS/MS system with turbo ion spray source in the positive ion and multiple reaction-monitoring mode. The limits of quantitation for all analytes were within 0.125–31.25 ng mL−1 in plasma and urine. The absolute recoveries of analytes from plasma and urine were all more than 50%. By means of the method developed, the plasma and urine samples from hepatic cancer patients and healthy age-matched volunteers had been successfully determined. Results showed that putrescine and spermidine in hepatic cancerous plasma were significant higher than those in healthy ones, while spermidine, spermine and N-acetylspermidine in hepatic cancerous urine were significant higher than those in healthy ones. The methods demonstrated the changes of polyamine metabolome occurring in plasma and urine from human subjects with hepatic cancer. It could be a powerful manner to indicate and treat hepatic cancer in its earliest indicative stages.  相似文献   

20.
A fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method was developed to study five endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol) in water. Different columns were tested; the chromatographic separation of the analytes was optimized on a Pinnacle DB biphenylic column with a water–acetonitrile gradient elution, which allowed the separation of the selected endocrine-disrupting compounds (EDCs) in less than 6 min. Quantitative analysis was performed in selected reaction monitoring (SRM) mode; two transitions were chosen for each compound, using the most abundant for quantitation. Calibration curves using bisphenol A-d 16 as internal standard were drawn, showing good correlation coefficients (0.9993–0.9998). All figures of merit of the method were satisfactory; limits of detection were in the low pg range for all analytes. The method was then applied to the determination of the analytes in real water samples: to this aim, polar organic chemical integrative samplers (POCIS) were deployed in the influent and in the effluent of a drinking water treatment plant in Liguria (Italy). The EDC level was rather low in the influent and negligible in the outlet, reflecting the expected function of the treatment plant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号