首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This work describes the preparation and characterization of six stationary phases for high-performance liquid chromatography (HPLC) obtained by deposition of poly(dimethylsiloxane) (PDMS) in HPLC silica particles, followed by immobilization using different processes (thermal treatments, thermal treatment + microwave irradiation, self-immobilization + gamma irradiation and self-immobilization + microwave irradiation). The chromatographic parameters of all the phases were evaluated with a mixture of test compounds having varied natures (acid, basic and neutral). The stability of one of these phases was evaluated in both a neutral mobile phase and a higher pH mobile phase used at an elevated temperature, with promising results.  相似文献   

2.
Complex analyses of polar compounds, especially basic ones, require more selective stationary phases. The present paper describes a stationary phase prepared by thermal immobilization of poly(methyltetradecylsiloxane) onto chromatographic silica (PMTDS-SiO(2)). This stationary phase presents hydrophobic and ion-exchange interactions that confer both high retention and unique selectivities for basic solutes. The influence of ion-exchange interactions is confirmed by the increase in retention factors of basic solutes when the mobile-phase pH changes from acidic to neutral and by the decrease in retention factors when the mobile-phase pH changes from neutral to alkaline. The ion-exchange properties of the stationary phase are enriched in neutral mobile phase (pH 7-7.5) using soft Lewis bases such as tricine and tris as buffers but are suppressed in both acidic (pH 2.5-6) and highly alkaline mobile phases (pH≤10). Increasing both temperature and flow rate permits more rapid separations while maintaining the selectivity. The stability of the stationary phase is evaluated with acid, neutral and alkaline mobile phases.  相似文献   

3.
Reversed-phase packing materials were prepared from HPLC silica and from zirconized HPLC silica support particles having sorbed poly(methyloctylsiloxane) (PMOS) as the stationary phase. Portions of zirconized material were subjected to 80 kGy of ionizing radiation. Columns prepared from these packing materials were subjected to 5000 column volumes each of neutral and alkaline (pH 10) mobile phases, with periodic tests to evaluate chromatographic performance. It was shown that the PMOS stationary phase sorbed onto zirconized silica requires an immobilization treatment (such as gamma irradiation) for long term stability while prior surface zirconization of the silica support surface greatly improves the chromatographic stability of the stationary phase when using alkaline mobile phases.  相似文献   

4.
5.
Compared to conventional C18 phases, polar‐modified phases have distinct differences with regards to chromatographic behavior. In the present study, ODS phases and polar‐modified phases were synthesized. The columns containing these new packings demonstrated satisfactory stability under both acidic (pH 1.5) and basic (pH 10) conditions. We evaluated the selectivity differences between alkyl and polar‐modified alkyl RP columns by using a range of neutral analytes. The polar‐modified alkyl phases showed excellent peak shapes for almost all compounds. We also compared the selectivity differences between them for separating nucleotides by using 100% aqueous mobile phase and tricyclic antidepressants in the intermediate pH mobile phases. The results demonstrated that polar‐modified phases display a significantly reduced hydrophobic nature and a significantly reduced silanol activity compared to the conventional C18 phases.  相似文献   

6.
A novel polydentate C18 silica column was evaluated at an elevated temperature under acidic, basic, and neutral mobile phase conditions using ACN and methanol as the mobile phase organic modifier. The temperature range was 40-200 degrees C. The mobile phase compositions were from 0 to 80% organic-aqueous v/v and the mobile phase pH levels were between 2 and 12. The maximum operating temperature of the column was affected by the amount and type of organic modifier used in the mobile phase. Under neutral conditions, the column showed good column thermal stability at temperatures ranging between 120 and 200 degrees C in methanol-water and ACN-water solvent systems. At pH 2 and 3, the column performed well up to about 160 degrees C at two fixed ACN-buffer compositions. Under basic conditions at elevated temperatures, the column material deteriorated more quickly, but still remained stable up to 100 degrees C at pH 9 and 60 degrees C at pH 10. The results of this study indicate that this novel C18 silica-based column represents a significant advancement in RPLC column technology with enhanced thermal and pH stability when compared to traditional bonded phase silica columns.  相似文献   

7.
Reversed phase high performance liquid chromatography (RPLC) is currently the method of choice for the analysis of basic compounds. However, with traditional silica materials, secondary interactions between the analyte and residual silanols produce peak tailing which can negatively affect resolution, sensitivity, and reproducibility. In order to reduce these secondary interactions, which comprise ion exchange, hydrogen bonding, and London forces interactions, chromatographic analyses can be carried out at low or high pH values where silanol groups and basic compounds are mostly uncharged. The chromatographic behaviour of a particular bidentate stationary phase, Zorbax Extend C18, was studied with a set of basic and neutral compounds. Thanks to a higher chemical stability than traditional silica based supports, analyses were carried out with a high pH mobile phase, which represents a good alternative to the acidic mobile phases generally used to reduce ion exchange interactions. The performance of this bidentate stationary phase was also compared with that of other supports and it was proved that it is advantageous to work with high pH mobile phases when analyzing basic compounds.  相似文献   

8.
As part of our program to develop more stable cyano (CN) high-performance liquid chromatography (HPLC) column packings, we have evaluated hydrolytic stability as a function of ligand connectivity, chain length, and side group steric protection and the pH of the mobile phase. Three accelerated tests were used to evaluate stability: (1) A non-HPLC screening test measuring carbon loss in refluxing MeOH-100 mM KH2PO4 pH 4.5 (1:1, v/v) solution; (2) a continuous flow HPLC test measuring capacity factor maintenance in 1% trifluoroacetic acid in water (pH 1.02) at 80 degrees C; and (3) a continuous flow HPLC test measuring column efficiency maintenance in 50 mM triethylamine in water (pH 10.00) at 50 degrees C. The stability of the CN phases was found to be dependent on both ligand chemical structure and the pH of the test conditions. The starting screen test of intermediate pH was least able to differentiate the CN phases based on structure, because two different degradation mechanisms appear to offset each other (acid induced siloxane bond cleavage vs. base induced silica dissolution). A trifunctional and a sterically protected CN phase were notably stable under the acidic test conditions, but had poor stability under basic conditions. Conversely, chain extension afforded poor stability under acidic conditions, but did afford improved stability at higher pH. In total, the data indicate that good CN column stability can be achieved by using a trifunctional or a sterically protected phase in acidic mobile phases. However, as mobile phases of intermediate or higher pH are employed, shorter column lifetimes can be expected due to an accelerated dissolution of the underlying silica substrate. Materials were also compared chromatographically using a mixture of non-polar, polar, and basic analytes under reversed-phase conditions.  相似文献   

9.
Lipophilicity was evaluated using a novel RP-HPLC stationary phase (Discovery-RP-Amide-C16) with and without 1-octanol added to the mobile phase. A set of 46 drugs and flavonoids characterized by a broad structural diversity and a wide log Poct range (-0.69 to 5.70) was selected for this study. This set consists of neutral solutes and solutes with acidic or ampholytic functionalities which were maintained neutral at pH 2.5 or 4. In our conditions, the addition of 1-octanol in the mobile phase proved a key factor to derive a lipophilicity index log k(w) highly correlated with log Poct for all investigated solutes. 1-Octanol improved the correlation between log Poct and log k(w) mainly by influencing the retention behavior of the solutes with log Poct values below +3. This study brings additional evidence that under proper experimental conditions of stationary and mobile phases, RP-HPLC is a very useful method to obtain log Poct values.  相似文献   

10.
In this investigation, capillary electrochromatography (CEC) with a novel stationary phase proved useful for the separation of neutral and acidic glycosphingolipids (GSLs). Four different gangliosides, namely G(M1a), G(D1a), G(D1b) and G(T1b), served as the acidic GSLs model solutes. The following four GSLs: galactosylceramide (GalCer), lactosylceramide (LacCer), globotriaosylceramide (Gb3Cer) and globotetraosylceramide (Gb4Cer) served as the typical neutral GSLs. The stationary phase, octadecyl sulfonated silica (ODSS), consisted of octadecyl functions bonded to a negatively charged layer containing sulfonic acid groups. Porous and non-porous ODSS stationary phases were examined. The retention behavior of the acidic and neutral GSLs was examined over a wide range of elution conditions, including the nature of the electrolyte and organic modifier and the pH of the mobile phase. The porous ODSS stationary phase yielded the separation of the four different gangliosides using a hydro-organic eluent of moderate eluent strength whereas the non-porous ODSS stationary phase permitted the separation of the four neutral GSLs with a mobile phase of relatively high eluent strength.  相似文献   

11.
Human growth hormone (hGH), a polypeptide of 191 amino acids, contains three methionine residues, two of which are susceptible to oxidation by both chemical and photochemical means (Met14 and Met125). To date, no method has existed for resolving the various mono- and di-oxidation products. We report on the resolution of these oxidized variants and native hGH at weakly (pH 3.5) acidic pH. Although all of the oxidized species can be resolved at pH 3.5, use of low pH and neutral pH mobile phases confer some advantages. For example, the Met14 oxidized variant (MetSO-14) and native hGH are best resolved at neutral pH and the mono-oxidized variants (MetSO-125 and MetSO-14) are best resolved at low pH. The effect of organic modifier on the separation of the oxidized variants was also evaluated. 1-Propanol was more effective than acetonitrile in the separation of MetSO-14 and native hGH while acetonitrile was more effective than 1-propanol in the separation of MetSO-125 and MetSO-14. In summary, mobile phase pH and organic modifier were shown to be important parameters in the separation of oxidized hGH variants.  相似文献   

12.
分别用乙二胺、二乙胺、三乙胺将自制的以甲基丙烯酸缩水甘油酯(GMA)为单体、乙二醇二甲基丙烯酸酯(EDMA)为交联剂的整体柱修饰为弱、强阴离子交换整体柱。考察了该整体柱的性能,选择出分离蛋白质(牛血清白蛋白、溶菌酶和谷胱甘肽)的最佳实验条件,并在最佳分离条件下考察了这些蛋白质在整体柱上的色谱行为和该整体柱对纤维素降解酶的分离纯化情况。实验结果表明,该整体柱性能良好,可以实现对纤维素降解酶的快速分离与纯化。同时,实验也证明采用梯度洗脱可以实现对某些蛋白质的分离纯化。  相似文献   

13.
Effects of high-pH environments on a stationary phase prepared by gamma-radiation immobilization of poly(methyloctylsiloxane) on titanium-grafted silica were investigated by HPLC testing with standard sample mixtures. The HPLC parameters indicate good stationary phase stability to 10000 column volumes each of mobile phases with pH of 7, 9 and 12. At pH 13, the efficiency decreases slowly, although reasonably good separations are still possible until increasing flow resistance no longer allows easy passage of the mobile phase.  相似文献   

14.
A novel stationary phase prepared by the thermal immobilization of poly(dimethylsiloxane) onto the surface of silica (PDMS–SiO2) has been described, evaluated and compared with 229 commercially available RP-LC stationary phases using the Tanaka column classification protocol. The phase exhibited many unique chromatographic properties and, based on the phases in the database, was most similar to the fluoroalkylated phases (aside from the obvious lack of fluoro selectivity imposed by the C–F dipole). The phase exhibited classic reversed-phase behaviour in acid mobile phase conditions and mixed-mode reversed-phase/cation-exchange retention behaviour in neutral mobile phase conditions. The phase exhibited acceptable stability at both low and intermediate pH, conditions which should impart optimum chromatographic selectivity to the phase. Retention of basic analytes was shown to occur by a “three site model” as proposed by Neue. This new PDMS–SiO2 stationary phase is extremely interesting in that the dominancy of its hydrophobic and ion-exchange interactions can be controlled by the influence of mobile phase pH, buffer type and concentration. The PDMS–SiO2 stationary phase may provide a complementary tool to reversed-phase and HILIC stationary phases. The present results highlight the fact that the type of buffer, its concentration and pH can not only affect peak shape but also retention, selectivity and hence chromatographic resolution. Therefore, in method development and optimization strategies it is suggested that more emphasis should be given to the evaluation of these mobile phase operating parameters especially when basic solutes are involved.  相似文献   

15.
Summary A global LSER model that relates HPLC retention to mobile phase composition and pH is tested for a varied group of solutes, both neutral and ionizable, in a polymeric column and methanol-water mobile phases. It is compared to the local LSER model developed only for a given mobile phase, i.e., a fixed organic modifier content, and to the global LSER model set only for neutral solutes. The global LSER model for neutral and ionizable solutes requires a few supplementary parameters over the other models tested, but it accounts for retention under any experimental conditions for a given column and methanol-water mobile phases, describing properly the interactions established in the HPLC system (hydrophobicity, hydrogen-bond acidity and basicity, dipolarity/polarizability…). This paper is number 13 of a series with the same general title: “Retention of Ionizable Compounds on HPLC” published in various journals.  相似文献   

16.
Retention factor, column efficiency and asymmetry factor were recorded for nine basic compounds on a number of RP-HPLC columns using phosphate and a variety of (MS-compatible) volatile mobile phase buffers of acid and neutral pH, in order to assess any effects of the buffer on performance. With formic or acetic acid, some phases gave partial or complete solute exclusion effects (reduced or negative k) compared with results using phosphate buffers at low pH. Despite its possible suppression of mass spectrometer sensitivity, trifluoroacetic acid was useful in enhancing retention times of relatively hydrophilic protonated bases, due to ion-pair effects. Peak shape was relatively poor on some pure silica-based ODS phases at pH 7 compared with results at acid pH. At low pH and at pH 7, ammonium and potassium phosphate gave very similar k, but the former may be preferable due to its volatile cation. Improved peak shapes, attributed to superior silanol masking effects, were obtained with ammonium phosphate at pH 7, but not at acid pH. Ammonium acetate gave acceptable peak shape at pH 7, but due to very limited buffer capacity, poor results were obtained for solutes having a pKa close to the mobile phase pH. Due to its instability, ammonium hydrogen carbonate is not a viable alternative buffer at pH 7.  相似文献   

17.
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on phenylhexylsiloxane- and pentafluorophenylpropylsiloxane-bonded superficially porous silica stationary phases (Kinetex Phenyl-Hexyl and Kinetex F5) for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation exchange) are important for the retention of weak bases for acetonitrile–water mobile phases, but virtually absent for the same compounds for methanol–water mobile phases. The selectivity of the Kinetex Phenyl-Hexyl stationary phase for small neutral compounds is similar to an octadecylsiloxane-bonded silica stationary phase with similar morphology Kinetex C-18 for both methanol–water and acetonitrile–water mobile phase compositions. The Kinetex Phenyl-Hexyl and XBridge Phenyl stationary phases with the same topology but different morphology are selectivity equivalent, confirming that solvation of the interphase region can be effective at dampening selectivity differences for modern stationary phases. Small selectivity differences observed for XTerra Phenyl (different morphology and topology) confirm previous reports that the length and type of space arm for phenylalkylsiloxane-bonded silica stationary phases can result in small changes in selectivity. The pentafluorophenylpropylsiloxane-bonded silica stationary phase (Kinetex F5) has similar separation properties to the phenylhexylsiloxane-bonded silica stationary phases, but is not selectivity equivalent. However, for method development purposes, the scope to vary separations from an octadecylsiloxane-bonded silica stationary phase (Kinetex C-18) to “phenyl phase” of the types studied here is limited for small neutral compounds. In addition, selectivity differences for the above stationary phases are enhanced by methanol–water and largely suppressed by acetonitrile–water mobile phases. For bases, larger selectivity differences are possible for the above stationary phases if electrostatic interactions are exploited, especially for acetonitrile-containing mobile phases.  相似文献   

18.
Abstract

Retention volume of proteins increased or decreased with increasing phosphate buffer or neutral electrolyte concentrations in the mobile phase. This variation suppressed or accelerated by changing pH values in the mobile phase. The behavior of proteins can be interpreted by knowing isoelectric points (pI) of proteins and pKa value of the residual silanol groups on the surface of diol-bonded porous glasses. Positively charged surface of proteins below pH 8.0 (cytochrome c, lysozyme) retarded the elution by the ion-adsorption effects and negatively charged proteins around pH 7.0 (egg albumin, bovin serum albumin) eluted earlier than expected by the ion-exclusion effects. These effects suppressed by increasing phosphate buffer and neutral electrolyte concentrations in the mobile phase. Size-exclusion separation was attained in the mobile phase over 0.1 M phosphates and 0.1 M NaCl concentrations at pH 7.0. Mcllvaine buffer and Gomori buffer showed opposite action to proteins for retention comparing with Soerensen phosphate buffer. Potassium thiocyanate showed the different action for retention of proteins comparing with other neutral electrolytes and acted like sodium dodecyl sulphonate.  相似文献   

19.
Zhang M  El Rassi Z 《Electrophoresis》2000,21(15):3126-3134
In this work, a commercially available diol-silica stationary phase was converted in situ to a chiral stationary phase by dynamically coating it with hydroxypropyl-beta-cyclodextrin (HP-beta-CD). This stationary phase was shown useful for the capillary electrochromatography (CEC) separation of neutral and anionic enantiomers such as some organochlorine pesticides and dansyl amino acids, respectively. The inclusion of HP-beta-CD in the mobile phase to produce the in situ chiral stationary phase allowed the rapid separation of the anionic dansyl amino acid enantiomers at relatively low electroosmotic flow (EOF). The formation of host-guest complexes between the dansyl amino acids and the neutral HP-beta-CD in the mobile phase lowered the actual charge-to-mass ratios of the anionic solutes, thus speeding up their transport by the EOF across the packed capillary column. Several parameters affecting enantioseparation were investigated, including the concentration of HP-beta-CD, ionic strength, pH, and organic modifier content of the mobile phase.  相似文献   

20.
The endogenous potent vasodilators and inhibitors of platelet aggregation S-nitrosoglutathione (GSNO) and S-nitroglutathione (GSNO2) are frequently analyzed by high-performance liquid chromatography (HPLC) using mobile phases of acidic pH. These systems are associated with problems stemming from rapid and considerable artifactual formation of GSNO from glutathione (GSH) and ubiquitous nitrite. We describe a novel ion-pairing HPLC method with UV absorbance detection at 334 nm for the highly specific and interference-free analysis of GSNO and GSNO2 in the presence of high GSH and nitrite concentrations. Complete avoidance of artifactual formation of GSNO was accomplished by using the anion-pairing agent tetrabutylammoniumhydrogen sulphate in the mobile phase that enables analysis of GSNO at neutral pH, at which GSH and nitrite do not react to form GSNO. This HPLC system was used to study formation of GSNO2 from GSH and peroxynitrite under physiological conditions. We found by this HPLC system that peroxynitrite (0-300 microM) reacts with GSH (0-5 mM) to form GSNO2 at a mean yield of 2%. Analysis of the same samples by a cation-pairing HPLC system with acidic mobile phase (pH 2.0) revealed, however, GSNO plus GSNO2 formation of the order of 20% due to on column reaction of GSH with peroxynitrite-derived nitrite to form GSNO. Ammonium sulfamate is frequently used to remove nitrite from thiol-containing solutions under acidic conditions. By means of the anion-pairing HPLC system it is demonstrated that nitrite removal by this method is incomplete even when ammonium sulfamate is used at high concentrations. These findings underscore the absolute requirement of neutral pH conditions for the analysis of GSNO. The novel anion-pairing HPLC method should be useful to provide reliable data on formation, reaction and metabolism of GSNO and GSNO2 in biological fluids using various detectors including mass spectrometers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号