首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
迟忠美  杨丽 《色谱》2022,40(6):509-519
目前使用的绝大多数药物为手性化合物,它们具有相似的物理和化学性质,但药理活性不同,且常以外消旋混合物的形式存在,因此对手性化合物的分离在生物、环境、食品和医药等领域一直备受关注。与广泛使用的液相色谱-质谱(LC-MS)相比,毛细管电泳-质谱(CE-MS)作为一种新型分离分析技术,具有分离效率高、样品和试剂消耗量低、选择性高和分离模式多样化等诸多优势,已经发展成为手性分析领域中有广阔应用前景的分析方法之一。CE-MS结合了CE的高分离效率和低样品消耗以及MS的高灵敏度和强结构解析能力,在蛋白质组学和代谢组学等领域发挥了重要作用。CE杰出的手性拆分能力与MS优势的结合,亦使CE-MS成为实现手性化合物高效分离分析的完美组合。在过去的十几年里,基于不同CE-MS分离模式的高性能手性分析体系层出不穷,如电动色谱-质谱(EKC-MS)、胶束电动色谱-质谱(MEKC-MS)和毛细管电色谱-质谱(CEC-MS)等,并成功应用于医药、生物、食品和环境科学等领域的手性化合物分析。该文主要综述了2011~2021年,CE-MS在手性化合物分析领域的技术、手性选择剂(如改性环糊精和聚合物表面活性剂等)的使用以及在医药等领域应用方面的研究进展,并讨论了不同手性分析模式的局限性,为未来的CE-MS手性分离分析技术发展及应用提供借鉴。  相似文献   

2.
CE hyphenated to ESI-MS (CE-ESI-MS) is a well-established technique to analyze charged analytes in complex samples. Although various interfaces for CE-MS coupling are commercially available, the development of alternatives which combine sensitivity, simplicity, and robustness remains a topic of research. In this work, a nanoflow sheath liquid CE-MS interface with two movable capillaries inside a glass emitter is described. The setup enables a separation mode and a conditioning mode to guide the separation capillary effluent either into the electrospray or to the waste, respectively. This enables to exclude parts of the analysis from MS detection and unwanted matrix components reaching the mass spectrometer, comparable to divert valves in LC-MS coupling. Also, this function improves the overall robustness of the system by reduction of particles blocking the emitter. Preconditioning with electrospray interfering substances and even the application of coating materials for every analysis is enabled, even while the separation capillary is built into the interface with running electrospray. The functionality is demonstrated by analyses of heavy matrix bioreactor samples. Overall, this innovation offers a more convenient installation of the interface, improved handling with an extended lifetime of the emitter tips and additional functions compared to previous approaches, while keeping the higher sensitivity of nanoflow CE-MS-coupling.  相似文献   

3.
Environmental samples such as soil solutions contain inorganic ions such as NH4(+), K(+), Na(+), NO3(-), and PO4(3-) in high concentrations, which must be removed prior to capillary electrophoresis-mass spectrometry analysis to obtain accurate results. However, the separation of these inorganic ions from ionic metabolites, which are the target compounds in capillary electrophoresis-mass spectrometry analysis, is difficult because the physicochemical properties of the inorganic ions are similar to those of the ionic metabolites. In this study, we used various solid-phase extraction (SPE) columns for the purification of the samples containing inorganic ions in high concentrations. We found that cation-exchange SPE columns successfully filtered out the inorganic ions while retaining most of the organic compounds, which were easily collected with high recovery rates. In addition, 17 cationic metabolites in the soil solution were quantified by CE-MS analysis following the SPE purification process. The results suggest that our method can be used to analyze other environmental samples containing inorganic ions in high concentrations.  相似文献   

4.
The purpose of this study was to develop a simple and sensitive CE‐UV method to quantify erlotinib and metabolites in urine. Following liquid–liquid extraction, erlotinib, and metabolites were separated with a BGE whose composition was phosphate buffer (pH 2.5, 65 mM) with 0.5% Tween 20. The applied voltage was 22 kV, capillary temperature 25°C and the sample injection was performed in the hydrodynamic mode. All the analyses were carried out in a fused silica capillary with an internal diameter of 75 μm and a total length of 37 cm. The detection of target compounds was performed at 240 nm. The calibration was linear in the range 0.15–20 mg/L for erlotinib and metabolites. Inter‐and intraday imprecision were less than 4%. This simple, sensitive, accurate, and cost‐effective method can be used in routine clinical practice to monitor erlotinib concentrations in urine from nonsmall cell lung cancer patients.  相似文献   

5.
A simple, sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of atorvastatin and its active metabolites ortho-hydroxyatorvastatin and para-hydroxyatorvastatin in human plasma using rosuvastatin as internal standard (IS). Following simple liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 559/440 for atorvastatin, m/z 575/466 for ortho-hydroxyatorvastatin, m/z 575/440 for para-hydroxyatorvastatin and m/z 482/258 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for atorvastatin and its two metabolites in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of atorvastatin, ortho-hydroxyatorvastatin, para-hydroxyatorvastatin and the IS from spiked plasma samples were 54.2 +/- 3.2, 50.1 +/- 3.8, 65.2 +/- 3.6 and 71.7 +/- 2.7%, respectively. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

6.
Acetaminophen (APAP) is a widely used analgesic and antipyretic drug. It is mainly metabolized by phase 1 and 2 reactions in the liver, and thus it could be involved in many drug–drug interactions. Therefore, the study of APAP metabolism is important in toxicological and pharmacokinetic studies. The objective of this study was to develop a rapid and sensitive method for the determination of APAP and its six metabolites in rat plasma for the pharmacokinetic studies. APAP and its metabolites were separated through a Capcell Pak MGII C18 column and quantitated with a 16 min run in a triple‐quadruple mass spectrometer. The mobile phases were composed of 0.1% formic acid in either 95% water or 95% acetonitrile and analysis was performed twice in positive and negative modes. Validations such as accuracy, precision, recovery, matrix effect and stability were found to be within acceptance criteria of validation guidelines, indicating that the assay was applicable to the determination of the plasma concentrations of drug and its six metabolites. In conclusion, we developed an LC‐MS/MS method for the quantitative analysis of APAP and its six metabolites in rat plasma, and this method appears to be useful for pharmacokinetic/toxicokinetic studies of APAP and its metabolites in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
梁玉  张丽华  张玉奎 《色谱》2020,38(10):1117-1124
蛋白质组学研究在生物学、精准医学等方面发挥着重要的作用。然而研究面临的巨大挑战来自生物样品的复杂性,因此在质谱(MS)鉴定技术不断革新的同时,发展分离技术以降低样品复杂度尤为重要。毛细管电泳(CE)技术具有上样体积小、分离效率高、分离速度快等优势,其与质谱的联用在蛋白质组学研究中越来越受到关注。低流速鞘流液和无鞘流液接口的发展及商品化推动了CE-MS技术的发展。目前毛细管区带电泳(CZE)、毛细管等电聚焦(CIEF)、毛细管电色谱(CEC)等分离模式已与质谱联用,其中CZE-MS应用最广泛。目前被广泛采用的蛋白质组学研究策略主要是基于酶解肽段分离鉴定的"自下而上(bottom-up)"策略。首先,CE-MS技术对酶解肽段的检测灵敏度高达1 zmol,已成功应用于单细胞蛋白质组学;其次,毛细管电泳技术与反相液相色谱互补,为疏水性质相近的肽段(尤其是翻译后修饰肽段)的分离鉴定提供了新的途径。基于整体蛋白质分离鉴定的自上而下"top-down"策略可以直接获得更精准、更完整的蛋白质信息。CE技术在蛋白质大分子的分离方面具有分离效率高、回收率高的优势,其与质谱的联用提高了整体蛋白质的鉴定灵敏度和覆盖度。非变性质谱(native MS)是一种在近生理条件下从完整蛋白质复合物水平上进行分析的质谱技术。CE与非变性质谱联用已被尝试用于蛋白质复合体的分离鉴定。该文引用了与CE-MS和蛋白质组学应用相关的93篇文献,综述了以上介绍的CE-MS的研究进展以及在蛋白质组学分析中的应用优势,并总结和展望了其应用前景。  相似文献   

8.
Liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was employed to investigate the in vitro metabolism of emodin. Emodin was incubated with rat liver microsomes in the presence of a NADPH-generating system, followed by extraction with ethyl acetate. After separation on a reversed-phase C18 analytical column with a linear gradient elution of methanol and 0.1% formic acid in water, negative electrospray ionization tandem mass spectrometry experiments were performed. As a result, the parent drug and its six metabolites were detected from rat liver microsomal incubations. The identification of the metabolites and elucidation of their structure were performed by comparing the changes in molecular masses (DeltaM), retention times and MS(2) spectral patterns of metabolites with those of parent drug. Besides three mono-hydroxylated metabolites (omega-hydroxyemodin, 2-hydroxyemodin, 4-hydroxyemodin), three other metabolites were identified, which were emodic acid, 3-carbomethoxy-6-methoxy-1,8-dihydroxyanthraquinone and physcion, respectively.  相似文献   

9.
Capillary electrophoresis-mass spectrometry was applied to the separation of several anionic dyes containing copper(II), chromium(III), or cobalt(III) as part of the dye molecule. The dyes were separated using a 110 cm x 50 microm uncoated fused-silica capillary and a 5 mM ammonium acetate buffer (pH 9) containing 40% acetonitrile. Excellent separation efficiencies (N = 500,000 plates/column) and low detection limits of 20-50 pg (selected ion monitoring, S/N = 10) were achieved. Mass spectra were acquired at different cone voltages. At low cone voltages (low collision energies), sensitivity was maximized and the mass spectra contained only signals of the (multiply charged) molecular ions and low levels of sodium ion and proton adducts. At higher cone voltages, the 2:1 (ligand:metal) chromium and cobalt dyes showed losses of one of the two dye ligands, accompanied by a reduction of the metal. The copper dyes showed signals due to loss of SO2 and SO3-, but no release of metal. Azo cleavage, otherwise typical of azo dyes, was not observed with the metallized dyes.  相似文献   

10.
The caffeine content of foods and beverages varies considerably, interfering with our ability to obtain valid interpretations in many human studies with regard to the mechanism of action(s) of caffeine and/or its metabolites. The rate of metabolism of caffeine and other xanthine drugs also varies greatly from one individual to another. Therefore, it is extremely important to develop accurate, reliable analytical methods to quantify caffeine and its metabolites in simple and complex matrixes. A simple method is described for the separation and characterization of caffeine and its major metabolites employing capillary electrophoresis (CE) coupled to ultraviolet-absorption and mass spectrometry (MS) detection. After optimization of the electrophoresis separation conditions, a reliable separation of caffeine and 11 of its major metabolites was achieved in 50 mM ammonium carbonate buffer, pH 11.0. The volatile aqueous electrolyte system used with a normal electroosmotic flow polarity also provided an optimal separation condition for the characterization of the analytes by MS. The CE method achieved baseline resolution for all 12 compounds in less than 30 min. The CE-MS method is suitable for use as a routine procedure for the rapid separation and characterization of caffeine and its metabolites. The usefulness of this method was demonstrated by the extraction, separation, and identification of caffeine and its 11 metabolites from normal urine samples. The urine specimens were first acidified to obtain optimum binding efficiency to the sorbents of the off-line, solid-phase extraction procedure employed here, and an acidified eluent solvent was employed for the desorption step to maximize the recovery of the bound analytes.  相似文献   

11.
Heroin metabolites including morphine, codeine, and 6-acetylmorphine were determined by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI–sweep-MEKC). Liquid–liquid extraction was used for urine pretreatment. An uncoated fused silica capillary (Ld = 30 cm, 50 μm ID) was filled with phosphate buffer (50 mM, pH 2.5) containing 30% methanol, then high conductivity buffer (100 mM phosphate, 41.3 kPa for 18 s) was followed. Samples were injected electrokinetically (20 kV, 300 s). The sweeping and separation were performed at −25 kV using phosphate buffer (20 mM, pH 2.5) and 80 mM sodium dodecyl sulfate. The baseline separation was done within 10 min. During method validation, the calibration curves were linear over a range of 50–500 ng/mL (r ≧ 0.994). The RSD and RE values in intra-day and inter-day assays were all below 20%, which showed good precision and accuracy. Their detection limits were 10 ng/mL (S/N = 3). The optimized method was applied to determine real urine samples from addicts. These samples were confirmed by liquid chromatography/mass spectrometry.  相似文献   

12.
Summary The use of HPLC-NMR-MS for the detection and identification of the metabolites of ibuprofen present in a solid phase extract of human urine is described. Gradient reversed-phase HPLC was used to separate the components present in the extract, which were then characterised by a combination of stopped-flow1H NMR and on line electrospray-MS. This approach led to the rapid identification of the known phase 1 human metabolites of ibuprofen, including hydroxy- and carboxy- metabolites, together with their respective glucuronide conjugates. In addition a probable artefact resulting from the dehydration of one of the side chainhydroxylated glucuronides was also identified.  相似文献   

13.
A rapid and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of buprenorphine and its three metabolites (buprenorphine glucuronide, norbuprenorphine and norbuprenorphine glucuronide) as well as naloxone and its metabolite naloxone glucuronide in the rat plasma. A hydrophilic interaction chromatography column and a mobile phase containing acetonitrile and ammonium formate buffer (pH 3.5) were used for the chromatographic separation. Mass spectrometric detection was achieved by an electrospray ionization source in the positive mode coupled to a triple quadrupole mass analyzer. The calibration curves for the six analytes displayed good linearity over the concentration range 1.0 or 5.0–1000 ng/mL. The intra and inter‐day precision (CV) ranged from 2.68 to 16.4% and from 9.02 to 14.5%, respectively. The intra‐ and inter‐day accuracy (bias) ranged from −14.2 to 15.2% and from −9.00 to 4.80%, respectively. The extraction recoveries for all the analytes ranged from 55 to 86.9%. The LC–MS/MS method was successfully applied to a pharmacokinetic study of buprenorphine–naloxone combination in rats.  相似文献   

14.
15.
The metabolism of tanshinone IIA was studied in rats after a single-dose intravenous administration. In the present study, 12 metabolites of tanshinone IIA were identified in rat bile, urine and feces with two LC gradients using LC-MS/MS. Seven phase I metabolites and five phase II metabolites of tanshinone IIA were characterized and their molecular structures proposed on the basis of the characteristics of their precursor ions, product ions and chromatographic retention time. The seven phase I metabolites were formed, through two main metabolic routes, which were hydroxylation and dehydrogenation metabolism. M1, M4, M5 and M6 were supposedly tanshinone IIB, hydroxytanshinone IIA, przewaquinone A and dehydrotanshinone IIA, respectively, by comparing their HPLC retention times and mass spectral patterns with those of the standard compounds. The five phase II metabolites identified in this research were all glucuronide conjugates, all of which showed a neutral loss of 176 Da. M9 and M12 were more abundant than other identified metabolites in the bile, which was the main excretion path of tanshinone IIA and the metabolites. M12 was the main metabolite of tanshinone IIA. M9 and M12 were proposed to be the glucuronide conjugates of two different semiquinones and these semiquinones were the hydrogenation products of dehydrotanshinone IIA and tanshinone IIA, respectively. This hydrogenized reaction may be catalyzed by the NAD(P)H: quinone acceptor oxidoreductase (NQO). The biotransformation pathways of tanshinone IIA were proposed on the basis of this research.  相似文献   

16.
The composition of wine is determined by a complex interaction between environmental factors, genetic factors (i.e., grape varieties), and winemaking practices (including technology and storage). Metabolomics using NMR spectroscopy, GC-MS, and/or LC-MS has shown to be a useful approach for assessing the origin, authenticity, and quality of various wines. Nonetheless, the use of additional analytical techniques with complementary separation mechanisms may aid in the deeper understanding of wine's metabolic processes. In this study, we demonstrate that CE-MS is a very suitable approach for the efficient profiling of polar ionogenic metabolites in wines. Without using any sample preparation or derivatization, wine was analyzed using a 10-min CE-MS workflow with interday RSD values for 31 polar and charged metabolites below 3.8% and 23% for migration times and peak areas, respectively. The utility of this workflow for the global profiling of polar ionogenic metabolites in wine was evaluated by analyzing different cool-climate Polish wine samples.  相似文献   

17.
Chen C  Yan H  Shen B  Zhuo X 《色谱》2012,30(5):445-451
建立了同时检测全血中青霉素G及其2种主要代谢产物青霉噻唑酸和脱羧青霉噻唑酸的超高效液相色谱-电喷雾串联质谱分析方法。血样经简单的蛋白沉淀提取后,目标化合物经BEH C18色谱柱(50 mm×2.1 mm, 1.7 μm),以含0.1%甲酸溶液-乙腈为流动相,梯度洗脱分离后,选用正离子电喷雾多反应监测(MRM)模式检测。方法检出限(信噪比(S/N)为3计)为0.1~2.0 ng/mL,定量限(S/N=10)为0.5~5.0 ng/mL。各被测物的线性相关系数均大于0.9974,准确度为92.3%~105.5%,日内精密度小于10%。考察了不同储存温度(18、4、-18、-80 ℃)下全血中青霉素G及其代谢物的稳定性,结果表明随着储存温度升高和时间的延长,青霉素G的质量浓度下降明显。应用建立的方法检测了给予20 mg/kg青霉素G后的大鼠血液样本,血液中青霉素G原形药物在给药后0.5 h即消除完全(低于检出限),而其代谢物的体内消除时限可延长至36 h。所建方法对司法鉴定的适用性得到了进一步扩大,同时对食品残留检测也具有一定的参考价值。  相似文献   

18.
Non-aqueous capillary electrophoresis (NACE) background electrolytes are most often composed of a mixture of methanol and acetonitrile (ACN) with soluble ammonium salts added as electrolyte. In this study on NACE-MS, we used a mixture of glacial acetic acid and ACN giving rise to an acidic background electrolyte (BGE) with a very low dielectric constant. Impressive changes in selectivity and resolution were observed for structurally closely related indole alkaloids including diastereomers upon addition of ammonium formate as electrolyte and upon variation of the solvent ratio. In order to obtain best separation and MS detection conditions and to reveal the influence of the parameters of the BGE on separation and detection and vice versa of the MS parameters on separation, an optimization strategy was employed using a design of experiments in a central composite design with response surface methodology. It was proven that at high electroosmotic flow conditions capillary electrophoretic separations and thus optimization can be realized without interference from the coupling to an MS system. Several significantly interacting parameters were revealed, which are not accessible with classical univariate optimization approaches. With this optimization, alkaloid mixtures from a plant extract of Mitragyna speciosa, containing a large number of diastereomeric compounds were successfully separated.  相似文献   

19.
This study developed a method for the simultaneous determination of erlotinib and its isomeric major metabolites, OSI‐413 and OSI‐420, in human plasma using an isocratic liquid chromatography–tandem mass spectrometry. Plasma specimens deproteinized with acetonitrile were separated using a 3‐µm particle size octadecylsilyl column. The m/z values of the precursor and product ions for the analytes were as follows: erlotinib, 394.2/278.2; and OSI‐413 and OSI‐420, 380.2/278.2. The total run time was 21 min and no peaks interfering with the analytes and internal standard (d6‐erlotinib) in human plasma were observed. The calibration curves of erlotinib, OSI‐413 and OSI‐420 were linear over the concentration ranges of 10–3000, 2–500 and 2–100 ng/mL, respectively. The pretreatment recovery ratios were >86.1%. The intra‐ and inter‐assay precisions and accuracies were <12.7 and 89.0–108.9% for all analytes. This validated method was applied to the determination of plasma samples in lung cancer patients receiving 150 mg of oral erlotinib. The plasma concentration ranges of erlotinib, OSI‐413 and OSI‐420 were 373–2354, 15.7–379 and 2.5–43.6 ng/mL, respectively. In conclusion, the present method can be helpful for evaluating the plasma exposures of erlotinib and its major isomeric metabolites in clinical settings. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
Pyrethroid insecticides are applied in the residential environment, as well as in agricultural crops, for insect control purpose. We developed and validated an accurate, sensitive, and reproducible analytical method to simultaneously detect seven pyrethroid metabolites, namely, 3‐(2,2‐dichlorovinyl)‐2,2‐dimethyl‐(1‐cyclopropane) carboxylic acid, 3‐(2,2‐dibromovinyl)‐2,2‐dimethyl‐(1‐cyclopropane) carboxylic acid, 3‐phenoxybenzoic acid, 4‐fluoro‐3‐phenoxybenzoic acid, 2‐methyl‐3‐phenylbenzoic acid, 4‐chloro‐α‐isoproply benzeneacetic acid, and 3‐(2‐chloro‐3,3,3‐trifluoroprop‐1‐enyl)‐2,2‐dimethylcyclopropanecarboxylic acid, in human urine. This method employs deconjugation with enzyme, SPE using Agilent C18 cartridges on a RapidTrace SPE workstation, derivatization using hexafluoro isopropanol and N,N′‐diisopropylcarbodiimide, and compounds separation and identification on GC–MS. The detection limits of seven metabolites were 0.02–0.08 ng/mL in urine. The recoveries of seven metabolites were 81–104%, 85–99%, and 83–99% in urine specimens fortified at 0.1, 0.4, and 3.2 ng/mL concentrations, respectively. The overall coefficient of variation was 4.3–10.8% in two quality control specimens which were repeatedly measured during a period of 2 months. This method was applied to urine samples collected from children living in Boston, MA. The median concentrations of six detected pyrethroid metabolites ranged from 0.06 to 0.86 ng/mL in urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏