1.
Summary Reproducibility of the Kovats retention indices of alkylbenzenes was studied on conventional “PONA” fused-silica capillary columns coated with crosslinked dimethyl silicone phase, with a film thickness of 0.5 μm. The data were compared with those obtained on conventional OV-101 columns. The tested PONA columns showed reproducible chromatographic properties, capacity ratios and high efficiencies. Having a standard deviation of s=0.03 i.u. of the retention indices on a single column, the column-to-columns differences were found to be up to 0.3 i.u. Higher indices were determined for crosslinked columns, the difference being in most cases about one i.u.  相似文献   

2.
Summary In order to determine the applicability of retention indices, based on the alkylarylketone scale, as the basis of a reproducible method of reporting retentions, the separation of ten barbiturates and a set of column test compounds were examined on an octadecylsilyl bonded silica (ODS-Hypersil) column with methanol-buffer pH 8.5 as eluent. The effects on the capacity factors and retention indices, on changing the eluent composition, pH, ionic strength and temperature, showed that the retention indices of the barbiturates were much less susceptible to minor changes in the eluent than the capacity factors. For non-ionised compounds the retention indices were virtually independent of the experimental conditions. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

3.
4.
This paper deals with the separation of alkanes, naphthenes, and aromatic compounds in naphtha and reformate, on a newly developed apolar high resolution GC column. The selectivity of this apolar phase has been compared with those of squalane, DB-1, and SE-30. A total of 95 hydrocarbons were reliably identified, mostly by GC-MS. Repeated measurements of Kováts retention indices are presented as evidence for the reproducible manufacture of fused silica columns coated with this phase.  相似文献   

5.
The long-term reproducibility of the separation of basic drugs by high-performance liquid chromatography using a silica column with a methanol-high-pH eluent was examined. The relative capacity factors of specific tertiary amines changed systematically compared with the other drugs on storage of the columns for 1 year. The changes were enhanced on storing the column in mobile phase and were accelerated by prolonged washing with water. A comparison of freshly packed columns suggested that similar changes also occurred with the dry silica on storage. These effects may be a contributor to previously observed batch-to-batch differences in the silica.  相似文献   

6.
Abstract

The effect of column dimensions on resolution, sample capacity, mobile-phase use and efficiency using both constant flow-rate and constant linear velocity was studied. The four columns selected have the same length (238 mm), but different diameters (column A: 4.6 mm; column B: 4.0 mm; column C: 3.2 mm and column D: 2.1 mm). It was observed that at constant floworate the reduced plate height was the lowest for columns B and C, higher for column A and highest for column D. On the other hand increasing the injected quantity while keeping injected volume constant revealed columns B and C to have a better efficiency only at the low concentrations. Column A with the largest diameter was superior at high concentrations and thus offers the best loadability. Column D offered, as expected, poor loadability. Examination of the columns at the same calculated linear velocity, showed no appreciable changes in efficiency for the four columns. Preferable detection limits and big solvent savings were obtained when small column diameters were used.  相似文献   

7.
Summary Wall-coated, open-tubular (capillary) columns prepared from different diameter tubing, with different liquid phase film thickness, are compared with each other and with packed and support-coated open-tubular columns. The comparison is based on the variation of the phase ratio and the capacity factor, and includes column efficiency (HETP, theoretical plate number), resolution, retention time, and sample capacity. Problems associated with the evaluation of the sample capacity are outlined. The influence of temperature on column performance is discussed in detail. Finally, the possibilities of short, wide-bore open-tubular columns prepared with a thick liquid-phase film are demonstrated.Parts of this paper were presented at the 35th Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Atlantic City NJ, March 5–9, 1984, and at the 20th International Symposium on Advances in Chromatography, New York NY, April 16–18, 1984.  相似文献   

8.
In reversed-phase liquid chromatography (RPLC), the comparison of experimental results obtained from different columns is a complex problem. A correspondence factor analysis (CFA) and a linear solvation energy relationship (LSER) were applied on retention data to characterize second-order intermolecular interactions responsible for retention on a set of RPLC columns. Seven octadecyl-C18 columns with different packing materials are obtained from different manufacturers and one octyl-C8 column. The retention data were determined under isocratic conditions using a methanol–water (65:35, v/v) mobile phase. The chromatographic retention indices based on alkan-2-ones and alkyl aryl ketones retention index scales are calculated using a multiparametric least-squares regressions iterative method. The CFA and LSER results permitted to highlight that the retention indices were appropriate for studying the second-order retention mechanisms on the eight chromatographic systems investigated and exhibited the best reproducibility. Although many earlier studies have reported the use of chemometric methods to characterize chemical factors affecting retention in RPLC using retention factors as retention parameters, this is the first study based on retention indices.  相似文献   

9.
Summary Glass capillary columns were prepared from non-deactivated and deactivated glass and coated with (2-methyl-4-[trans-4-n-propyl-cyclohexylcarbonyloxy]-benzoic acid-[4-n-heptyloxy-phenylester]) as the liqud phase, in different film thicknesses. The columns were tested using substances of different structures and polarities. It was verified that the capacity factors, retention indices and selectivity significantly depend on the thickness of the liquid crystalline stationary phase film and the quality of the tube, particularly in the case of columns with thin films. Trasition temperatures (melting and clearing point) of the liquid crystal are also dependent on these two factors.Dedicated to Professor J. F. K. Huber on the occasion of the his 60th birthday.  相似文献   

10.
The gas chromatographic separation of fatty acid methyl esters (FAMEs) on ionic liquid stationary phases was investigated. Seven commercially available ionic liquid columns were tested using a test mixture containing 37 fatty acid methyl esters. The influence of column temperature on the elution order was studied using five different temperature programs. Retention times were highly reproducible. Similar retention behavior was observed for the IL59, IL60, and IL61 columns. The peak pair C18:1 cis/trans was not baseline resolved on these columns, whose stationary phases are highly similar. C18:2 cis/trans, C18:3 n6/n3, and C20:3 n6/n3 were baseline separated on all columns. Baseline separation of the complete test mix was only obtained on the IL82 column using a heating rate of 5 K/min. In general, retention times decreased with increasing column polarity but unsaturated FAMEs were retained stronger compared to their saturated counterparts. Except for the IL59 column, retention crossover was observed when the temperature program was changed.  相似文献   

11.
In reversed phase liquid chromatography, the retention indices of benzene and nine mono substituted benzenes with different functionality based on the alkan-2-ones and alkyl aryl ketones retention index standards have been determined by the application of two new mathematical adaptation methods, viz. a multiparametric least-squares regression iterative method based on the determination of the adjusted retention times and a local cubic interpolation method directly using the total retention times. The two methods were applied to two types of columns. The first group includes four octadecyl-C18 columns with different packing materials obtained from different manufacturers, while the second comprises an octyl-C8 column. The retention indices have been extensively studied using either methanol–water or acetonitrile–water mobile phase systems. The influences of the concentration of the organic modifier in the mobile phase (methanol or acetonitrile), the column temperature, and the column packing material on retention indices of the set of the ten monoaromatics studied were also investigated. The calculated multiparametric retention indices values, those obtained by the local cubic interpolation and Kováts’ methods are compared. Good agreement was observed between the retention indices calculated by the three methods.  相似文献   

12.
黄维雄 《色谱》2020,38(4):399-408
近年来,开管离子色谱(OTIC)的研究已取得重大进展,尤其是兼容OH-淋洗液的OTIC柱的成功研制使OTIC梯度洗脱得以实现。该文介绍了各种OTIC柱的制备和表征方法,涵盖早期的二氧化硅开管柱和新近出现的有机聚合物基质开管柱,对静电乳胶附聚的OTIC柱的一系列表征方法进行了系统阐述,包括开管柱柱容量的实验测定和理论计算方法、固定相相同时填充柱与开管柱之间的联系、柱效改善方法以及开管柱均一性表征等。  相似文献   

13.
Abstract

As continuation of our study on the characterization of column packings in normal-phase HPLC analysis, the retention indices of ten fat-soluble vitamins on aminopropyl and cyanopropyl bonded silica columns were systematically estimated using binary solvents containing ethyl acetate (EtOAc), tetrahydrofuran (THF) or 2-propanol (PrOH) in n-hexane. A linear relationship between the logarithm of the capacity ratio and that of the solvent composition was confirmed. The retentivity and selectivity for these chemically bonded packing columns were determined as follows: the amino-type column has stronger and cyano-type column weaker retentivity than the bare silica column for n-hexane-EtOAc or THF binary systems. Specific adsorption of tocopherol derivatives containing phenolic hydroxyl groups on the amino column was observed. To obtain high efficiency in the separation of fat soluble vitamins, peak sharpness and asymmetry factors were measured using three columns and three binary solvents. The bare silica and PrOH binary solvent generally gave superior peak shape for all vitamin samples.  相似文献   

14.
The effects of the pressure drop across the column on retention and efficiency in SFC have been studied. Numerical methods are described which enable the prediction of hold-up time and pressure drop in both packed and open tubular columns. Predictions of both hold-up time and pressure drop are in good agreement with experimental data. The density gradient along the column can be calculated using the numerical methods and a procedure is described which enables the calculation of the overall capacity factors of the solutes from the density profile in the column. Significant variations of the capacity factor are observed along the column. The effect of the density gradient along the column on local diffusivity and dispersion is studied. The column efficiency in systems with significant pressure drops is affected by changes in: the linear velocity of the mobile phase; the diffusion coefficients; and the capacity factors of the solutes along the column. The overall efficiency of the chromatographic system can be calculated if, as is the case for open tubular columns, adequate plate height equations are available.  相似文献   

15.
Optimisation of peak capacity is an important strategy in gradient liquid chromatography (LC). This can be achieved by using either long columns or columns packed with small particles. Monolithic columns allow the use of long columns at relatively low back-pressure. The gain in peak capacity using long columns was evaluated by the separation of a tryptic bovine serum albumin digest with an LC–UV–mass spectrometry (MS) system and monolithic columns of different length (150 and 750 mm). Peak capacities were determined from UV chromatograms and MS/MS data were used for Mascot database searching. Analyses with a similar gradient slope for the two columns produced ratios of the peak capacities that were close to the expected value of the square root of the column length ratio. Peak capacities of the short column were 12.6 and 25.0 with 3 and 15 min gradients, respectively, and 29.7 and 41.0 for the long column with 15 and 75 min gradients, respectively. Protein identification scores were also higher for the long column, 641 and 750 for the 3- and 15-min gradients with the short column and 1,376 and 993 for the 15- and 75-min gradients with the long column. Thus, the use of long monolithic columns provides improved peptide separation and increased reliability of protein identification.  相似文献   

16.
Chromatographic properties of silica-, zirconia- and alumina-based columns with octadecyl-, polyethylene glycol- and pentafluorophenylpropyl-bonded stationary phases were tested. Selectivities of nine columns for LC were characterized using chromatographic methods including Walters, Engelhardt, Tanaka and Galushko hydrophobicity and silanol activity tests, measurements of methylene selectivity in various aqueous-methanol and aqueous-acetonitrile mobile phases and of gradient lipophilic capacity as a measure of the effect of the sample hydrophobicity on gradient-elution separations. A semi-empirical interaction indices model, assuming a predominant role of the solvophobic interactions of test compounds with different polarities, was compared with the linear free energy relationships approach taking into account selective polar interactions. The interaction indices model was applied to both non-polar stationary phases bonded on silica, alumina and zirconia supports, and to the non-modified adsorbents in the normal-phase LC. The retention data of isomeric naphthalene disulfonic acids were used to compare the attractive and repulsive ionic interactions of the columns in purely aqueous mobile phases. The results of the hydrophobicity and polarity tests were consistent, and allowed column characterization and classification. Silanol activity was important with octadecyl silica columns, but was relatively insignificant with bonded polyethylene glycol and pentafluorophenylpropyl phases on silica gel support. Polar interactions with the alumina and zirconia support materials significantly affect the retention.  相似文献   

17.
The procedure for calculating linear temperature programmed indices as described in part 1 has been evaluated using five different nonpolar columns, with OV-1 as the stationary phase. For fourty-three different solutes covering five different classes of components, including n-alkanes and alkyl-aromatic compounds, both isothermal and temperature programmed indices were determined. The isothermal information was used to calculate temperature programmed indices. For several linear programmed conditions accuracies better than 0.51T-units were usually obtained. The results are compared with published procedures. It is demonstrated that isothermal retention information obtained on one column can be transferred to another column with the same stationary phase but different column dimensions and/or phase ratio. The temperature programmed indices calculated in this way also have an accuracy better than 0.51T-u. The temperature accuracy and precision of the GC-instrumentation used was of the order of 0.1°C. All calculations can be run with a Basic-programmed microcomputer.  相似文献   

18.
Four methacrylate ester‐based monolithic columns for capillary liquid chromatography (CLC) were prepared by radical polymerization with ammonium peroxodisulfate (3 columns) and by thermal initiation (1 column). The polymerization mixture consisted of butyl methacrylate (BMA) and ethylene glycol dimethacrylate (EDMA), propan‐1‐ol, butane‐1,4‐diol, water, and ammonium peroxodisulfate as initiator. It was necessary to add N,N,N′,N ′‐tetramethylethylenediamine (TEMED) to the polymerization mixture to activate the reaction. The amount of initiator and activator was optimized to attain quantitative polymerization. The reproducibility of three columns prepared at ambient temperature was studied. The most efficient column with HETP of 29 μm for uracil was compared to the monolithic column prepared by thermal initiation with α,α′‐azobisisobutyronitrile (AIBN). The efficiencies of all the test columns were characterized by van Deemter curves. Their total porosities were calculated from the retention time of uracil. Walters indices of hydrophobicity (HI) were calculated from the retention factors of anthracene and benzene. The columns prepared by both methods are comparable in their selectivities and efficiencies. They show the same characteristics because their total porosities and Walters indices of hydrophobicity are consistent. However, the preparation of monoliths using ammonium peroxodisulfate was less demanding, because polymerization was possible at ambient temperature.  相似文献   

19.
Direct conversion of isothermal to temperature programmed indices is not possible. In this work it is shown that linear temperature programmed retention indices can only be calculated from isothermal retention data if the temperature dependence of both the distribution coefficients and the column dead time are taken into account. Procedures are described which allow calculation of retention temperatures and from these, accurate programmed retention indices. Within certain limits the initial oven temperature and programming rate can be chosen freely. The prerequisite for this calculation is the availability of reliable isothermal retention data (retention times, retention factors, relative retention times, or retention indices) at two different temperatures for one column. The use of compiled isothermal retention indices at two different temperatures for the calculation of retention temperatures and thus temperature programmed indices is demonstrated. For the column for which programmed retention indices have to be determined, the isothermal retention times of the n-alkanes and the column dead time as a function of temperature have to be known in addition to the compiled data for a given stationary phase. Once the programmed retention indices have been calculated for a given column the concept allows the calculation of temperature programmed indices for columns with different specifications. The characteristics which can be varied are: column length, column inner diameter, phase-ratio, initial oven temperature, and programming rate.  相似文献   

20.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   