首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Luo Y  Zhang Q  Qin J  Lin B 《Electrophoresis》2007,28(24):4769-4771
Hydrostatic pressure sample injection method is able to minimize the number of electrodes needed for a microchip electrophoresis process; however, it neither can be applied for electrophoretic DNA sizing, nor can be implemented on the widely used single-cross microchip. This paper presents an injector design that makes the hydrostatic pressure sample injection method suitable for DNA sizing. By introducing an assistant channel into the normal double-cross injector, a rugged DNA sample plug suitable for sizing can be successfully formed within the cross area during the sample loading. This paper also demonstrates that the hydrostatic pressure sample injection can be performed in the single-cross microchip by controlling the radial position of the detection point in the separation channel. Rhodamine 123 and its derivative as model sample were successfully separated.  相似文献   

2.
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip CE separations. The PDMS devices used for the evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3?psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~ 100?pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure, and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1?Hz to > 2?Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4-cm-long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations for multiplexing CE separations and for sample-limited bioanalyses are discussed.  相似文献   

3.
Reproducible and representative sample injection in microchip electrophoresis has been a bottleneck for quantitative analytical applications. Electrokinetic sample injection is the most used because it is easy to perform. However, this injection method is usually affected by sample composition and the bias effect. On the other hand, these drawbacks are overcome by the hydrodynamic (HD) sample injection, although this injection mode requires HD flow control. This review gives an overview of the basic principles, the instrumentation designs, and the performance of HD sample injection systems for microchip electrophoresis.  相似文献   

4.
The stacking of a cationic analyte (i.e., rhodamine B) at the interface between a sample reservoir and channel in a microchip electrophoresis device is described for the first time. Stacking at negative polarity was by micelle to solvent stacking where the dye was prepared in a micellar solution (5 mM sodium dodecyl sulfate in 25 mM phosphoric acid, pH 2.5) and the channel was filled with high methanol content background solution (70% methanol in 50 mM phosphoric acid, pH 2.5). The injection of the stacked dye into the channel was by simple reversal of the voltage polarity with the sample solution and background solution at the anodic and cathodic reservoirs of the straight channel, respectively. The enrichment of rhodamine B at the interface and injection of the stacked dye into the channel was clearly visualized using an inverted fluorescence microscope. A notable sensitivity enhancement factor of up to 150 was achieved after 2 min at 1 kV of micelle to solvent stacking. The proposed technique will be useful as a concentration step for analyte mixtures in simple and classical cross‐channel microchip electrophoresis devices or for the controlled delivery of enriched reagents or analytes as narrow plugs in advanced microchip electrophoresis devices.  相似文献   

5.
Microchip electrophoresis (MCE) has been advanced remarkably by the applications of several separation modes and the integration with several chemical operations on a single planer substrate. MCE shows superior analytical performance, e.g., high-speed analysis, high resolution, low consumption of reagents, and so on, whereas low-concentration sensitivity is still one of the major problems. To overcome this drawback, various online sample preconcentration techniques have been developed in MCE over the past 15 years, which have successfully enhanced the detection sensitivity in MCE. This review highlights recent developments in online sample preconcentration in MCE categorized on the basis of "dynamic" and "static" methods. The dynamic techniques including field amplified stacking, ITP, sweeping, and focusing have been easily applied to MCE, which provide effective enrichments of various analytes. The static techniques such as SPE and filtration have also been combined with MCE. In the static techniques, extremely high preconcentration efficiency can be obtained, compared to the dynamic methods. This review provides comprehensive tables listing the applications and sensitivity enhancement factors of these preconcentration techniques employed in MCE.  相似文献   

6.
This review highlights recent developments and applications of on-line sample preconcentration techniques to enhance the detection sensitivity in microchip electrophoresis (MCE); references are mainly from 2008 and later. Among various developed techniques, we focus on the sample preconcentration based on the changes in the migration velocity of analytes in two or three discontinuous solutions system, since they can provide the sensitivity enhancement with relatively easy experimental procedures and short analysis times. The characteristic features of the on-line sample preconcentration applied to microchip electrophoresis (MCE) are presented, categorized on the basis of "field strength-" or "chemically" induced changes in the migration velocity. The preconcentration techniques utilizing field strength-induced changes in the velocity include field-amplified sample stacking, isotachophoresis and transient-isotachophoresis, whereas those based on chemically induced changes in the velocity are sweeping, transient-trapping and dynamic pH junction.  相似文献   

7.
Various analytical techniques have been developed over the years to analyse a large diversity of biomolecules with a constant push towards ultra-sensitive detection. CE is at the forefront of the most powerful analytical tools available to date when considering its superior efficiency and resolution; however, the technique suffers from poor sensitivity as a result of the short path length at the detection site and small injection volumes (typically <1% capillary length). One of the approaches to abate the inherent problem is to employ clever chemistry using sample focusing techniques whereby a large sample plug can be injected, preconcentrated and separated, producing excellent sensitivity and efficiency at the detector. This particular review will focus on the use of dynamic pH junction as a means of improving sensitivity in CE and focuses on the use of a change in analyte ionisation due to different pHs between the sample and electrolyte. The review provides a fundamental discussion of the mechanisms, buffer and sample conditions required to concentrate various analytes and a comprehensive list of published works in tabular format for easy identification of suitable conditions for new applications. The review further encompasses the use of dynamic pH junction in CE and its involvement in combination with other preconcentrations techniques to produce high sensitivity enhancements recorded between the years 1990-2010.  相似文献   

8.
Long Z  Liu D  Ye N  Qin J  Lin B 《Electrophoresis》2006,27(24):4927-4934
Microfluidic devices integrating membrane-based sample preparation with electrophoretic separation are demonstrated. These multilayer devices consist of 10 nm pore diameter membranes sandwiched between two layers of PDMS substrates with embedded microchannels. Because of the membrane isolation, material exchange between two fluidic layers can be precisely controlled by applied voltages. More importantly, since only small molecules can pass through the nanopores, the integrated membrane can serve as a filter or a concentrator prior to microchip electrophoresis under different design and operation modes. As a filter, they can be used for separation and selective injection of small analytes from sample matrix. This has been effectively applied in rapid determination of reduced glutathione in human plasma and red blood cells without any off-chip deproteinization procedure. Alternatively, in the concentrator mode, they can be used for online purification and preconcentration of macromolecules, which was illustrated by removing primers and preconcentrating the product DNA from a PCR product mixture.  相似文献   

9.
Hirokawa T  Takayama Y  Arai A  Xu Z 《Electrophoresis》2008,29(9):1829-1835
Aiming to achieve high-performance analysis of DNA fragments using microchip electrophoresis, we developed a novel sample injection method, which was given the name of floating electrokinetic supercharging (FEKS). In the method, electrokinetic injection (EKI) and ITP preconcentration of samples was performed in a separation channel, connecting two reservoir ports (P3 and P4) on a cross-geometry microchip. At these two stages, side channels, crossing the separation channel, and their ports (P1 and P2) were electrically floated. After the ITP-stacked zones passed the cross-part, they were eluted for detection by using leading ions from P1 and P2 that enabled electrophoresis mode changing rapidly from ITP to zone electrophoresis (ZE). Possible sample leakage at the cross-part toward P1 and P2 was studied in detail on the basis of computer simulation using a CFD-ACE+ software and real experiments, through which it was validated that the analyte recovery to the separation channel was almost complete. The FEKS method successfully contributed to higher resolution and shorter analysis time of DNA fragments on the cross-microchip owing to more rapid switching from ITP status to ZE separation in comparison with our previous EKS procedure realized on a single-channel microchip. Without any degradation of resolution, the achieved LODs were on average ten times better than using conventional pinched injection.  相似文献   

10.
Lacharme F  Gijs MA 《Electrophoresis》2006,27(14):2924-2932
We propose two variants of a new injection technique for use in electrophoresis microchips, called "front gate pressure injection" and "back gate pressure injection", that both enable a controlled and reproducible sample introduction with reduced bias compared to electrokinetic gated injection. A continuous flow of a test solution of fluorescein/rhodamine B in 20 mM Tris/boric acid buffer (pH 8.6) sample test solution is electrokinetically driven near to the entrance of the separation channel, using a single voltage (3 kV) that is constant in time. A sample plug is injected in the separation channel by a pressure pulse of the order of 0.1 s. The latter is generated using the mechanical deflection of a PDMS membrane that is loosely placed on a dedicated chip reservoir. The analysis of the peak area ratio of the separated compounds demonstrates a nearly constant sample composition when using pressure-based injection. A small remaining injection bias for the shortest membrane deflection times can be attributed to a dilution effect of the charged compound due to the presence of an electrical field transverse to the sample flow boundary in the channel junction.  相似文献   

11.
Surface modification in microchip electrophoresis   总被引:1,自引:0,他引:1  
Belder D  Ludwig M 《Electrophoresis》2003,24(21):3595-3606
Different approaches and techniques for surface modification of microfluidic devices applied for microchip electrophoresis are reviewed. The main focus is on the improved electrophoretic separation by reducing analyte-wall interactions and manipulation of electroosmosis. Approaches and methods for permanent and dynamic surface modification of microfluidic devices, manufactured from glass, quartz and also different polymeric substrates, are described.  相似文献   

12.
Micro free flow electrophoresis (µFFE) is a valuable technique capable of high throughput rapid microscale electrophoretic separation along with mild operating conditions. However, the stream flow separation nature of free flow electrophoresis affects its separation performance with additional stream broadening due to sample stream deflection. To reduce stream broadening and enhance separation performance of µFFE, we presented a simple microfluidic device that enables injection bandwidth control. A pinched injection was formed in the reported µFFE system using operating buffer at sample flow rate ratio (r) setting. Initial bandwidth at the entrance of separation chamber can be shrunk from 800 to 30 µm when r increased from 1 to 256. Stream broadening at the exit of separation chamber can be reduced by about 96% when r increased from 4 to 128, according to both theoretical and experimental results. Moreover, the separation resolution for a dye mixture was enhanced by a factor of 4 when r increased from 16 to 128, which corresponded to an 80% reduction in sample initial bandwidth. Furthermore, a similar enhancement on amino acids separation was obtained by using injection control in the reported µFFE device and readily integrated into online/offline sample preparation and/or downstream analysis procedures.  相似文献   

13.
Capillary electrophoresis on microchip   总被引:10,自引:0,他引:10  
Capillary electrophoresis and related techniques on microchips have made great strides in recent years. This review concentrates on progress in capillary zone electrophoresis, but also covers other capillary techniques such as isoelectric focusing, isotachophoresis, free flow electrophoresis, and micellar electrokinetic chromatography. The material and technologies used to prepare microchips, microchip designs, channel geometries, sample manipulation and derivatization, detection, and applications of capillary electrophoresis to microchips are discussed. The progress in separation of nucleic acids and proteins is particularly emphasized.  相似文献   

14.
Zhang L  Yin X  Fang Z 《Lab on a chip》2006,6(2):258-264
A simple method for injecting well-defined non-biased sample plugs into the separation channel of a microfluidic chip-based capillary electrophoresis system was developed by a combination of flows generated by negative pressure, electrokinetic and hydrostatic forces. This was achieved by using only a single syringe pump and a single voltage supply at constant voltage. In the loading step, a partial vacuum in the headspace of a sealed sample waste reservoir was produced using a syringe pump equipped with a 3-way valve. Almost instantaneously, sample was drawn from the sample reservoir across the injection intersection to the sample waste reservoir by negative pressure. Simultaneously, buffer flow from the remaining two buffer reservoirs pinched the sample flow to form a well-defined sample plug at the channel intersection. In the subsequent separation stage, the vacuum in headspace of the sample waste reservoir was released to terminate all flows generated by negative pressure, and the sample plug at the channel intersection was electrokinetically injected into the separation channel under the potential applied along the separation channel. The liquid levels of the four reservoirs were optimized to prevent sample leakage during the separation stage. The approach considerably simplified the operations and equipment for pinched injection in chip-based CE, and improved the throughput. Migration time precisions of 3.3 and 1.5% RSD for rhodamine123 (Rh123) and fluorescein sodium (Flu) in the separation of a mixture of Flu and Rh123 were obtained for 56 consecutive determinations with peak height precisions of 6.2% and 4.4% RSD for Rh123 and Flu, respectively.  相似文献   

15.
Wu XZ  Zhang LH  Onoda K 《Electrophoresis》2005,26(3):563-570
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH-. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.  相似文献   

16.
A procedure for separation and quantitation of methylmercury by capillary electrophoresis using sample stacking as the injection technique is presented. The CE conditions have been optimized in order to separate the methylmercury from the excess cysteine peak and to concentrate large volumes of sample obtaining a low detection limit. Under the proposed operational conditions, the detection limit (S/N = 3) was 12 ng g and the limit of quantitation (S/N = 10) was 20 ng g−1 with a linear range of 20–100 ng g−1 (as methylmercury in samples). The method was tested using different reference materials with a certified methylmercury content.  相似文献   

17.
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split–flow sampling interface integrated on the micro-chip. The microfluidic system measured 20×70×3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 μm I.D.×60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h−1 throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 μl and carrier flow-rate of 2.0 ml min−1. Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8–80 s, at separation lengths of 25–35 mm and electrical field strengths of 250–1500 V cm−1, with plate heights in the 0.7–3 μm range.  相似文献   

18.
Guchardi R  Schwarz MA 《Electrophoresis》2005,26(16):3151-3159
Sensitivity is a crucial point in the development applications for medicine or environmental samples in which the analytes are present in the nanomolar range. Besides further technical development of detection systems, the multiplex sample injection technique can be applied for enhancing the signal-to-noise ratio. Hadamard transform is easily applied to microchip electrophoresis due to the fact that sample injection is generally achieved through cross, double-tee, or tee injector structures. This paper reports the first demonstration of a modified Hadamard transform electrophoresis on a microchip by using an amperometric detector. Contrary to the previous Hadamard applications, the resolution (number of points per unit of time) of electropherograms obtained is independent of the number of injections.  相似文献   

19.
Optimization of geometry and surface modification of microchip input reservoirs were performed to achieve uninterferenced pressure-induced sample injection of multiple samples into microreactors using a single syringe pump. Nine samples of 3.5 microL were pipetted onto input reservoirs and loading of PCR mixture into 260 nL microreactors was achieved followed by successful PCR amplification, confirming that no cross-contamination occurs during injection.  相似文献   

20.
Jiang L  Lu Y  Dai Z  Xie M  Lin B 《Lab on a chip》2005,5(9):930-934
This paper presents the development of a mini-electrochemical detector for microchip electrophoresis. The small size (3.6 x 5.0 cm2, W x L) of the detector is compatible with the dimension of the microchip. The use of universal serial bus (USB) ports facilitates installation and use of the detector, miniaturizes the detector, and makes it ideal for lab-on-a-chip applications. A fixed 10 M ohm feedback resistance was chosen to convert current of the working electrode to voltage with second gain of 1, 2, 4, 8, 16, 32, 64 and 128 for small signal detection instead of adopting selectable feedback resistance. Special attention has been paid to the power support circuitry and printed circuit board (PCB) design in order to obtain good performance in such a miniature size. The working electrode potential could be varied over a range of +/-2.5 V with a resolution of 0.01 mV. The detection current ranges from -0.3 x 10(-7) A to 2.5 x 10(-7) A and the noise is lower than 1 pA. The analytical performance of the new system was demonstrated by the detection of epinephrine using an integrated PDMS/glass microchip with detection limit of 2.1 microM (S/N = 3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号