1.
软骨藻酸(domoic acid,DA)是一种由海洋硅藻产生的生物毒素,具有强烈的神经毒性,近海水环境中的DA严重威胁海洋渔业生物和人类健康,因此对近海水环境中的DA进行有效监测至关重要.该文基于固相萃取-液相色谱-串联质谱联用技术(SPE-LC-MS/MS),建立了适用于海水中痕量、超痕量DA的检测方法.针对近海水生...  相似文献   

2.
This paper describes a rapid gas chromatographic/mass spectrometric (GC/MS) screening method for the detection of drugs of abuse and/or their metabolites in urine. Synthetic stimulants, opiates, cocaine metabolites, cannabinoids--and specifically the acid metabolite of tetrahydrocannabinol (THC-COOH)--can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, and assayed as trimethylsilyl derivatives by GC/MS in SIM (selected ion monitoring) mode. All the analytes show a good linearity (R2 > 0.99 for most of the considered substances) in the range 25-1000 ng/mL, with a good reproducibility of both the retention times (CV% <0.7) and the relative abundances of the characteristic diagnostic ions (CV% <13). The limit of detection (LOD) of the method is 25 ng/mL of target compound in human urine for most of the substances investigated, 3 ng/mL for THC-COOH, and 10 ng/mL for norbuprenorphine. Validation of the method allows its application to different fields of forensic analytical toxicology, including antidoping analysis.  相似文献   

3.
A fast liquid chromatographic/mass spectrometric (LC/MS/MS) screening method for the detection, in urine, of synthetic glucocorticoids, stimulants (formoterol, modafinil and mesocarb), anti-oestrogens (finasteride, exemestane, anastrozole, letrozole and formestane) and synthetic anabolic steroids (stanozolol, gestrinone and tetrahydrogestrinone) is described. All these drugs (and/or their urinary metabolites) can be simultaneously extracted by a single liquid/liquid extraction step, at alkaline pH, after enzymatic hydrolysis with beta-glucuronidase, and assayed in 7 min by LC/MS/MS using electrospray ionization in positive ion mode and multiple reaction monitoring as the acquisition mode. All compounds show good reproducibility of both the retention times (CV% <2%) and the relative abundances (CV% <10%). The limits of detection for the anti-oestrogens, glucocorticoids and steroids are in the range of 1-30 ng/mL, and for the stimulants are in the range of 100-200 ng/mL, thus satisfying the minimum required performance limits of the World Anti-Doping Agency.  相似文献   

4.
A new analytical approach, based on derivatization with 2,2,2-trichloroethyl chloroformate and gas chromatography/mass spectrometry (GC/MS), was investigated for qualitative and quantitative analyses of a large range of amphetamine-related drugs and ephedrines in plasma, urine and hair samples. Sample preparation involved alkaline extraction of analytes from biological samples using Extrelut columns, after addition of the internal standard 3,4-methylenedioxypropylamphetamine (MDPA), and subsequent derivatization to produce 2,2,2-trichloroethylcarbamates. GC/MS analyses, in splitless mode using a slightly polar 30-m capillary column, were performed with quadrupole or ion trap instruments. MS acquisition modes were electron ionization (EI) in full-scan or selected ion monitoring (SIM) modes (quadrupole), and full-scan MS or MS/MS modes with chemical ionization (CI) conditions (ion trap). EI spectra of 2,2,2-trichloroethylcarbamates showed variably abundant molecular ions as well as abundant diagnostic fragment ions, both characterized by ion clusters reflecting the isotope distribution of three chlorine atoms in the derivatized molecules. CI spectra showed abundant protonated molecules. Quantitative studies using EI SIM conditions gave recoveries in the range 74-89%, linear response over ranges of 10-2000 ng/mL (plasma and urine) and 0.20-20 ng/mg (hair), with corresponding limits of detection in the ranges 2-5 ng/mL and 0.1-0.2 ng/mg. Potential applications (following full method validation) include clinical and forensic toxicology, as well as doping control.  相似文献   

5.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
The performance of gas chromatography coupled with tandem mass spectrometry (GC/MS/MS) was tested for the simultaneous determination of twelve pyrethroid insecticides. First, a comparison of two different ionization modes, electron ionization (EI) and negative chemical ionization (NCI), was carried out using MS and MS/MS. NCI-MS/MS provided the best results in terms of selectivity and sensitivity giving very low detection limits of 0.11 to 450 fg injected. The reliability of the method was confirmed through the evaluation of quality parameters such as accuracy (70-100%), and repeatability and reproducibility, with coefficients of variation below 15% and 10%, respectively. The applicability of the GC/MS/MS method to real samples and influence of matrix effects were evaluated through the analysis of spiked water, sediment and milk at 0.25 ng L(-1) , 5 ng g(-1) dry weight (dw) and 25 ng g(-1) (dw), respectively, of each pyrethroid insecticide considered. Using GC/NCI-MS/MS, matrix spectral interferences were minimized providing method limits of detection (MLODs) of 0.05-2.59 ng L(-1) , 0.10-87.7 pg g(-1) dw, 2.29-1071 pg g(-1) lipid weight (lw) for water, sediment and milk, respectively. To the best of our knowledge, the MLOD values found in our study were better than those reported in previous studies; in particular for sediment and food samples, they were one order of magnitude lower.  相似文献   

7.
The aims were to develop a liquid chromatographic (LC) method with ultraviolet detection (UVD) for O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) O-oximes of common aldehydes and ketones, and to define the steric limits of the synthetic reaction used to make the PFBHA O-oxime standards for gas chromatographic (GC) and LC methods. Ten new O-oximes were synthesized with the new optimized method, and their purities were demonstrated by GC/electron-capture detection (ECD), GC/mass spectrometry (MS), ultraviolet spectroscopy, infrared spectroscopy, and proton and 13C-nuclear magnetic resonance spectroscopy. Ketones substituted at both beta-carbons relative to the carbonyl carbon, like diisobutyl ketone and 2,4-hexanedione, showed lower synthetic yields by wet chemistry methods. A new C18 reverse-phase LC method with UVD at 200 nm and acetonitrile-water in both the isocratic and gradient-elution modes was then developed to sensitively resolve a mixture of 13 pure PFBHA O-oximes. The detection limit was near 100 ng O-oxime/mL or about 14-50 ng aldehyde/mL and the least quantifiable limits were near 500 ng/mL or about 70-250 ng aldehyde/mL, with lower limits for glyoxal, methylglyoxal, benzaldehyde, and acetophenone. Carbonyl compounds in 500 mL water samples were then determined in distilled water and tap water by gradient elution. Vapors of n-valeraldehyde and acrolein generated in gas bags at concentrations near occupational guidelines were also sampled, desorbed, and then determined by either isocratic or gradient elution at 200 or 254 nm within 30-45 min.  相似文献   

8.
建立了尿中2,4-滴(2,4-D)、2,4-滴丙酸(2,4-DP)2、甲4氯(MCPA)和2甲4氯丙酸(MCPP)4种苯氧羧酸类除草剂的气相色谱-质谱(GC-MS)分析方法。尿样加氯化钠饱和,酸化后用乙醚萃取,萃取物进行特丁二甲硅烷基(TBDMS)衍生化后分析。尿中4种除草剂的浓度在3~3 000 ng/mL范围内工作曲线的线性关系良好,检出限在1 ng/mL以下,3、100和1 000 ng/mL水平加标回收率在97.0%~102.2%之间,精密度在6.2%~14.2%之间。该法灵敏,可用于中毒者和职业接触者尿中苯氧羧酸类除草剂的分析。  相似文献   

9.
This paper describes a fast gas chromatographic/mass spectrometric (GC/MS) screening method for the detection, in urine, of 36 xenobiotics (30 synthetic anabolic steroids, four narcotics, one diuretic and one stimulant) excreted free or as glucuro-conjugates in urine and detectable as trimethylsilyl (TMS) derivatives. These drugs (and/or their urinary metabolites) can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, after enzymatic hydrolysis with beta-glucuronidase and then assayed as TMS derivatives by GC/MS using electron ionisation (EI) and single ion monitoring (SIM) acquisition mode. The total time needed for the GC run is less than 8 min. Good reproducibility of the retention times (CV% <1) and the relative abundances of the diagnostic fragment ions (CV% <10) was observed for all target analytes. The sensitivity of the method is sufficient to match the requirements of the World Anti-Doping Agency (WADA) for the accredited laboratories, with limits of detection (LODs) that are lower than the corresponding WADA minimum required performance limits (MRPLs) for all target compounds.  相似文献   

10.
A micro‐SPE technique was developed by fabricating a rather small package including a polypropylene membrane shield containing the appropriate sorbent. The package was used for the extraction of some triazine herbicides from aqueous samples. Solvent desorption was subsequently performed in a microvial and an aliquot of extractant was injected into GC‐MS. Various sorbents including aniline‐ortho‐phenylene diamine copolymer, newly synthesized, polypyrrole, multiwall carbon nanotube, C18 and charcoal were examined as extracting media. Among them, conductive polymers exhibited better performance. Influential parameters including extraction and desorption time, desorption solvent and the ionic strength were optimized. The developed method proved to be rather convenient and offers sufficient sensitivity and good reproducibility. The detection limits of the method under optimized conditions were in the range of 0.01–0.04 ng/mL. The RSDs at a concentration level of 0.1 ng/mL were obtained between 4.5 and 9.3% (n=5). The calibration curves of analytes showed linearity in the range of 0.05–10 ng/mL. The developed method was successfully applied to the extraction of selected triazines from real water samples. The whole procedure showed to be conveniently applicable and quite easy to manipulate.  相似文献   

11.
《Analytical letters》2012,45(15):2311-2317
The present work describes the methodology and validation of gas chromatography with flame ionization (FID) and mass spectrometric (MS) detection after derivatization with N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) for determination of atenolol with an internal standard (metoprolol) in pharmaceutical preparations. The linearity was established over the concentration range of 0.5–20 μg/mL for GC/FID and 12.5–500 ng/mL for GC/MS method. The intra- and inter-day relative standard deviation was less than 4.72 and 5.80%, respectively. Limit of quantification was determined as 500 ng/mL and 12.5 ng/mL for GC/FID and GC/MS, respectively. No interference was found from tablet excipients at the selected assay conditions. Developed GC/FID and GC/MS methods in this study are accurate, sensitive, and precise and can be easily applied to Tensinor tablet as pharmaceutical preparation.  相似文献   

12.
气质联机分析蔬菜中农药多残留及基质效应的补偿   总被引:22,自引:0,他引:22  
摘要建立了蔬菜中52种农药化合物的气相色谱\|质谱检测方法, 考察了基质效应和分析保护剂在方法中的应用, 评价了3种分析保护剂组合的加入对补偿基质效应的影响, 确定了最佳配比. 样品前处理采用乙腈提取, 用PSA(Primary-secondary amine)固相材料分散净化技术, 用气质联机在选择离子监测模式下分析检测. 该方法在0.01~1.00 mg/L范围内线性关系良好, 相关系数大于0.98, 最低检测浓度除溴氰菊酯和异菌脲外均在0.2~9.4 mg/kg之间, 各化合物添加回收率为81.8%~119.5%, 相对标准偏差为0.8%~17.6%.  相似文献   

13.
A method is described that permits the measurement of the levels of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in human liver, kidney, adipose tissue, brain, basal ganglia, hypophysis, thyroid, gonads, pancreas, lung, skeletal muscle and blood, even in subjects not occupationally exposed to these compounds. The purification of samples involved the use of trifunctional (tC18) and strong anion-exchange (SAX) solid-phase extraction cartridges, and the analysis utilized a high-performance liquid chromatograph coupled to a single quadrupole mass spectrometer (LC/MS). The analyses were conducted on a mixed-bed reversed-phase column by gradient runs using 3 mM ammonium acetate/methanol mixtures at different proportions as the mobile phase. The detector was used in electrospray negative ion mode by recording simultaneously the ions m/z 413.0 (PFOA) and 499.0 (PFOS). Perfluorononanoic acid (PFNA), added to the samples before the purification, was used as the internal standard (ion monitored = m/z 463.6). The recovery rates of the extraction procedure ranged from 79.6 to 95.6% (CV% 1.7-7.4%) for PFOA, from 79.7 to 100.8% (CV% = 1.2-7.1) for PFOS, and from 89.1 to 102.3% (CV% = 0.9-5.2 %) for PFNA. The calibration curves were linear up to at least 400 ng of analytes per gram of tissue. The detection limits (signal-to-noise ratio = 3) were 0.1 ng/g for both PFOA and PFOS measured in all tissues except adipose tissue, where the limits were about 0.2 ng/g. The content of analytes in tissues varied from 0.3 to 3.8 ng/g (respectively: basal ganglia and lung) for PFOA, and from 1.0 to 13.6 ng/g (respectively: skeletal muscle and liver) for the linear isomer of PFOS. The method is suitable to evaluate the content of PFOA and PFOS in different tissues taken from the general population exposed to very low concentrations of these pollutants.  相似文献   

14.
建立了在线液相-气相二维色谱测定卷烟主流烟气中4-(N-甲基亚硝胺基)-1-(3-吡啶基)-1-丁酮(NNK)的方法。 NNK 的分析在在线凝胶气质联用仪上进行,采用自行装填的微型碱性氧化铝柱,并把仪器上的凝胶柱换成氧化铝柱,用于 NNK 的分析。捕集有主流烟气总粒相物的剑桥滤片用二氯甲烷提取,以 D4-NNK 为内标,提取液经微型氧化铝柱分离,含 NNK 的部位切割进入气相色谱,排干溶剂后启动气相色谱升温经毛细管柱进行分离,用质谱检测。本方法将烟气国标方法 NNK 测定中的氧化铝柱色谱净化和气相色谱-质谱分析在线连接起来,可不经样品前处理净化直接进样分析;每次进样可达40μL,是常规气相色谱-质谱分析最大进样量(2.0μL)的20倍,显著提高了分析灵敏度。方法线性范围达1.2~120 ng/ mL,相关系数为r=0.9998,回收率为93.9%~96.0%;检出限和定量限分别为0.25 ng/ mL 和0.9 ng/ mL,样品分析结果与中国烟草总公司企业标准方法进行对比,结果相符合。  相似文献   

15.
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.  相似文献   

16.
A direct injection liquid chromatography–electrospray ionization–tandem mass spectrometric method (LC‐ESI‐MS/MS) was developed and validated for the rapid and simple determination of 13 phenylalkylamine derivatives. Eight deuterium‐labeled compounds were prepared for use as internal standards (ISs) to quantify the analytes. Urine samples mixed with ISs were centrifuged, filtered through 0.22 µm filters and then injected directly into the LC‐ESI‐MS/MS system. The mobile phase was composed of 0.2% formic acid and 2 mM ammonium formate in distilled water and 0.2% formic acid and 2 mM ammonium formate in acetonitrile. The analytical column was a Capcell Pak MG‐II C18 (150 × 2.0 mm i.d., 5 µm, Shiseido). Separation and detection of the analytes were accomplished within 10 min. The linear ranges were 5–750 ng/mL (ephedrine and fenfluramine), 10–750 ng/mL (3,4‐methylenedioxyamphetamine, phendimetrazine, methamphetamine, 3,4‐methylenedioxyethylamphetamine and benzphetamine), 20–750 ng/mL (norephedrine, amphetamine, phentermine and ketamine) and 30–1000 ng/mL (3,4‐methylenedioxymethamphetamine and norketamine), with determination coefficients, R2, ≥ 0.9967. The intra‐day and inter‐day precisions were within 19.1%. The intra‐day and inter‐day accuracies ranged from ?16.0 to 18.7%. The lower limits of quantification for all the analytes were lower than 26.5 ng/mL. The applicability of the method was examined by analyzing urine samples from drug abusers (n = 30). Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A rapid and sensitive gas chromatographic method using flame ionization detection (GC–FID) has been developed and validated for five process related non-chromophoric impurities viz, 2-(2-chloroethoxy)ethanol (2-CEE), piperazine, 2-(piperazin-1-yl)ethanol (HEP), 2-[2-(piperazin-1-yl)ethoxy]ethanol (HEEP), 2,2-[piperazine-1,4-diylbis(ethane-2,1-diyloxy)]diethanol (DEEP) observed during the process development of quetiapine hemifumarate, an antipsychotic drug is presented. All five non-chromophoric impurities ranging from 0.05 to 0.1% were detected using DB-5 (30 m × 0.53 mm, 5 μm) column with a good peak separation. The method was fully validated according to the ICH Q2 (R1) guidelines. The investigated validation protocols showed that the method has acceptable specificity, accuracy, linearity, precision, robustness and high sensitivity with detection limits and quantitation limits ranging from 0.001 to 0.01% and 0.004 to 0.03%, respectively. These non-chromophoric impurities generated during the process were identified by GC–MS and are characterized by MS, 1H NMR and FT-IR spectroscopy.  相似文献   

18.
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS(3)-SRM) without solid-phase extraction (SPE) pre-purification and concentration procedures. To increase the selectivity of the method, MS(3) was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R(2)) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS(3)-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods.  相似文献   

19.
Retrospective detection and identification of markers of chemical warfare agents are important aspects of verification of the Chemical Weapons Convention. Alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs) are important markers of nerve agents. We describe the development and optimization of a new gas chromatography/mass spectrometry (GC/MS) injection port fluorination method for the derivatization of AAPAs and APAs. The process involved the injection of acids with trifluoroacetic anhydride in GC/MS, where acids are converted into their corresponding volatile fluorides. Various reaction conditions such as fluorinating agent, injection port temperature and splitless time were optimized. The maximum reaction efficiency of the acids with trifluoroacetic anhydride was observed at 230 degrees C injection port temperature with a splitless time of 2 min. APAs showed best analytical efficiencies at 400 degrees C injection port temperature, while the other conditions were similar to those of AAPAs. The linearities of response for APAs and AAPAs were in the range of 1-25 and 5-100 microg mL(-1), respectively, with limits of detection ranging from 500 pg to 800 ng mL(-1).  相似文献   

20.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   