首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Determination of phosphorus in small amounts of protein samples by ICP–MS   总被引:3,自引:0,他引:3  
Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.  相似文献   

2.
Isotope-dilution analysis in combination with GC-ICP-MS detection has been applied to the determination of butyltin species in environmental samples. Different spikes containing the isotopically labeled butyltin species have been synthesized in the laboratory after optimization of the reaction conditions. The isotopic compositions of the tin species in the different spike solutions were determined by GC-ICP-MS after derivatization by aqueous ethylation with sodium tetraethylborate. Reverse isotope-dilution analysis was used for quantitation of the spike solutions by means of natural MBT, DBT, and TBT standards. The mixed spikes were used for simultaneous analysis of MBT, DBT and TBT in the certified reference materials, PACS-2, CRM 462, and CRM 646, with satisfactory results. The excellent agreement of the different speciation results obtained by use of the different spikes is a good indicator of the precision, accuracy, and reliability which can be achieved by using isotope-dilution analysis for trace metal speciation.Application of a double spike containing (119)Sn-enriched MBT (79.7 At%), (118)Sn-enriched DBT (86.7 At%), and (119)Sn-enriched TBT (83.1 At%) also enabled evaluation of the conditions resulting in quantitative extraction of the species from the solid matrix, in combination with possible alterations depending on the different extraction procedures used (mechanical shaking, ultrasounds, and microwaves). Mathematical equations used for this purpose computed the correct species concentrations directly and, additionally, the decomposition factors (from TBT to DBT and from DBT to MBT) after precise measurement of the (119)Sn/(120)Sn and (118)Sn/(120)Sn ratios for all butyltin species by GC-ICP-MS.  相似文献   

3.
A method has been developed for the simultaneous determination of antifouling pesticides and some of their degradation products, e.g. dichlofluanid, diuron, demethyldiuron, 1-(3,4-dichlorophenyl)urea, sea-nine, Irgarol 1051 and one of its metabolites (2-methylthio-4-tert-butylamino-s-triazine) in marine sediments. The determination of these compounds in sediment samples was performed by means of methanolic ultrasonic extraction then clean-up on an Isolute ENV+ solid phase extraction (SPE) cartridge. The resulting extract was then analyzed by reversed-phase high-performance liquid chromatography coupled with atmospheric-pressure chemical-ionization mass spectrometry in negative and positive ion modes (HPLC–APCI–MS). Recovery ranged from 54–109% for the antifouling agents and their degradation products. The determination limits for the different compounds varied between 0.2 and 1.6 μg kg–1 dry sediment. The analytical procedure was successfully applied to the determination of these pesticides and their degradation products in marine sediment samples from different marinas of the Catalan coast. The compounds detected were: diuron, dichlofluanid, demethyldiuron, sea-nine, and Irgarol 1051. The highest concentrations were those of diuron and Irgarol 1051 – 136 and 88 μg kg–1, respectively.  相似文献   

4.
This study focused on the detection/identification of possible selenium metabolites in human urine. Organoselenium compounds not commercially unavailable were synthesized and characterized by electrospray mass spectrometry. Separation of selenomethionine, methylselenomethionine, trimethylselonium, selenoethionine, and selenoadenosylmethionine was achieved by ion-pairing HPLC with a mobile phase of 2 mmol L–1 hexanesulfonic acid, 0.4% acetic acid, 0.2% triethanolamine (pH 2.5), and 5% methanol. The column effluent was introduced on-line to inductively coupled plasma–mass spectrometry for selenium-specific detection (77Se and 78Se). For selenium speciation in urine, solid-phase extraction was carried out using C18 cartridges modified with hexanesulfonic acid. Selective retention of cationic species was observed from acidified urine (perchloric acid, pH 2.0). After elution with methanol, evaporation, and dissolution in the mobile phase, the sample was introduced to the HPLC–ICP–MS system and the chromatographic peaks were assigned by adding standards. The species identified in urine were selenomethionine, trimethylselonium ion, and selenoadenosylmethionine. The last species was detected for the first time and our results suggest that selenomethionine might enter the metabolic pathway of its sulfur analog in the activated methylation cycle.Kazimierz Wrobel and Katarzyna Wrobel are on the leave from the Institute of Scientific Research, University of Guanajuato, L. de Retana No. 5, 36000 Guanajuato, Gto., Mexico  相似文献   

5.
Human liver biopsy samples, collected from 52 individuals, were analysed by inductively coupled plasma–mass spectrometry (ICP–MS) and total reflection X-ray fluorescence (TXRF) spectrometry in a retrospective study (i.e. patient selection and liver biopsy were not for the purpose of element analysis). The freeze-dried samples (typically 0.5–2 mg dry weight) were digested in a laboratory microwave digestion system and solutions with a final volume of 1 mL were prepared. The concentrations of Cr, Mn, Fe, Ni, Cu, Zn, Rb, and Pb were determined by use of a Thermo Elemental X7 ICP–MS spectrometer. TXRF measurements were performed with an Atomika Extra IIA spectrometer. Yttrium was employed as an internal standard, prepared by dissolution of 5N-purity yttria (Y2O3) in our laboratory. The accuracy was tested by analysis of NIST 1577a Bovine Liver certified reference material. The concentrations of Fe, Cu, Zn, and Rb determined in human liver biopsy samples were in good agreement with data published by other authors. The distribution of nickel in the samples was surprisingly uneven—nickel concentrations ranged from 0.7 to 12 μg g−1 (dry weight) in 38 samples and in several samples were extremely high, 36–693 μg g−1. Analysis of replicate procedural blanks and control measurements were performed to prevent misinterpretation of the data. For patients with steatosis (n=14) Ni concentrations were consistently high except for two who had levels close to those measured for the normal group. As far as we are aware no previous literature data are available on the association of steatosis with high concentration of nickel in human liver biopsies taken from living patients. This paper was presented in part at the 2005 European Winter Conference on Plasma Spectrochemistry Budapest, Hungary.  相似文献   

6.
7.
Zhang  Chunhua  Wu  Huiqin  Huang  Xiaolan  Zhu  Zhixin  Luo  Huitai  Huang  Fang  Lin  Xiaoshan 《Chromatographia》2012,75(9-10):499-511

A sensitive and selective method for simultaneous determination of 29 toxic alkaloids in human blood and 31 in urine using high-performance liquid chromatography–electrospray ionization-tandem mass spectrometry was developed and validated. The samples were diluted with 0.1 mol L−1 HCl, and the target alkaloids were purified by solid phase extraction. The separation of 31 alkaloids was carried out on a C18 column using a gradient mobile phase with 10 mmol L−1 ammonium formate in water with 0.1% formic acid and methanol at the rate of 0.25 mL min−1. The triple-quadrupole mass spectrometer equipped with an electrospray source in the positive mode was set up in the dynamic multiple reactions monitoring mode (dynamic MRM) to detect the ion transitions of 31 alkaloids. The calibration curves were linear over a range of 0.5–400, 1–400, or 4–400 μg L−1 for target alkaloids in human blood and urine, and the correlation coefficients (r 2) was higher than 0.9943. The limit of determination and limit of quantification were 0.2–1 and 0.5–4 μg L−1 for blood and urine, respectively. The only exceptions were sanguinarine and chelerythrine in human blood. All the target alkaloids were stable under the test condition. In addition, the solvent effect and reconstituted solution were investigated. The method was validated and proved to be accurate and precise over the studied concentrations and suitable for poisoning diagnosis and forensic toxicology.

  相似文献   

8.
9.
Quantification of chromium in whole blood has been performed by ICP–quadrupole MS. The spectrometer was equipped with a dynamic reaction cell (DRC) with ammonia as reaction gas. The rejection parameter q (RPq) of the DRC and the flow rate of ammonia (NH3) were optimized and set at 0.7 and 0.6 mL min−1, respectively. Blood was diluted 1:51 (v/v) with an aqueous solution containing 0.1 mg L−1 NH4OH, 0.1 g L−1 EDTA, 5 mg L−1 n-butanol, and 0.1‰ Triton X100. Non-spectral matrix effects observed when using the DRC were confirmed by use of vanadium. External calibration with blank and standard solutions prepared in purified water led to biased results for quality control samples. Standard addition calibration was therefore used and its validity verified. By comparing the slopes and calculating residues, it was proved that the plot obtained with standard additions and the plot obtained from blood samples of different concentrations were aligned down to 0.05 μg L−1 after dilution.  相似文献   

10.
A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP–MS). High resolution (HR) ICP–MS was used to examine the influence of polyatomic interferences on the detection of the 52Cr+ and 53Cr+ isotopes. If there was strong interference with m/z 52 for plastic materials, it was possible to use quadrupole ICP–MS for m/z 53 if digestions were performed with HNO3+H2O2. This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH4+/NH3 buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC–ICP–MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc–nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient. In the case of painted metallic plate, because of a reactive matrix towards Cr(VI), its extraction without degradation was difficult to perform.  相似文献   

11.
Six related substances were detected in diosmin bulk drug substances and products by a newly developed gradient reverse-phase high performance liquid chromatography (RP-HPLC) with UV detection. The chromatographic system consisted of an Intersil Wondasil TM ODS (C 18) column (250 × 4.6 mm; 5 μm). The mobile phase consisted of water/acetic acid 66:6 v/v (solvent A) and methanol (solvent B) using a gradient program at a flow rate of 0.8 mL min?1 with 345 nm detection and an injection volume of 20 μL. In addition, the linearity, quantitation limit (QL), accuracy, selectivity, robustness and precision were determined. Good linearity was obtained over the concentration range 0.5–200 μg mL?1 with the coefficient of determination (r 2) of 0.999. The QL was 0.125 μg mL?1 (relative standard deviation <2.0 %). The major impurities have been resolved and identified using two analytical systems, HPLC and HPLC/electrospray ionization-mass spectrometry operated in a negative ion mode. One of these impurities marked as 7-hexopyranosidal diosmetin was unknown and has not been reported previously. Based on mass spectrometry data the structure of the new impurity was proposed as 5-hydroxy-2-(3-hydroxy-4-methoxyphenyl)-4-oxo-4H-chromen-7-yl hexopyranoside. The newly developed RP–LC method for quantitative determination of diosmin-related substances was found to be precise, accurate, robust and specific. It has been successfully employed for the quality evaluation of different sources of raw material and generic formulations of diosmin.  相似文献   

12.
A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL?1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.  相似文献   

13.
A simple, sensitive, selective and rapid liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous separation and quantitation of atenolol and chlorthalidone in human plasma using metoprolol and hydrochlorothiazide as internal standard. Following solid phase extraction, the analytes were separated by an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction-monitoring mode (atenolol in positive and chlorthalidone in the negative ion mode). The limit of quantitation for this method was 10 and 15 ng mL?1 and the linear dynamic range was generally 10–2,050 ng mL?1 and 15–3,035 ng mL?1 for atenolol and chlorthalidone, respectively.  相似文献   

14.
A simple and rapid LC–MS–MS assay was developed and validated for the quantitative determination of pitavastatin in human plasma. Sample pretreatment involved simple protein precipitation by addition of acetonitrile. Separation was on an Agilent 1.8 μm Zorbax SB-C18 column (150 mm × 4.6 mm) at 25 °C using isocratic elution with methanol–0.1% formic acid in water (85:15, v/v) at a flow rate of 0.4 mL min?1. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 422.0 → 290.1 for pitavastatin, and m/z 330.1 → 192.1 for paroxetine (IS). LC–MS–MS was found to improve the quantitation of pitavastatin in plasma and was successfully applied in pharmacokinetic studies.  相似文献   

15.
The simultaneous determination of Gd3+ and Gd-DTPA (DTPA: diethylenetriamino-pentaacetic acid), often used as contrast agent, is described. The proposed approach combines size-exclusion chromatography (SEC) and inductively coupled plasma–mass spectrometry (ICP–MS) for element-selective detection in order to determine also high-molecular Gd-complexes if present. This method was applied to the analysis of urine samples of a patient to whom Gd-DTPA was intravenously administered. The results showed that no conversion or adsorption of Gd-DTPA could be observed in any sample, even free Gd3+ could not be detected. Urine excretion behaviour was monitored and it was proved that Gd-DTPA was almost completely (>99%) excreted by urination within one day. Traces of Gd-DTPA could be measured in hair samples, but extraction with tetramethylammonium hydroxide (TMAH) resulted in degradation of Gd-DTPA.  相似文献   

16.
The determination of trace elements in pure quartz glass samples has been performed by coupling an ICP quadrupole mass spectrometer with the LINA-Spark-Atomizer, an IR laser ablation system dedicated to direct bulk and surface analysis of solid samples. Linear calibration curves were obtained for nine elements (Na, Al, Ca, Ti, Cr, Mn, Zr, Ba, and Pb) in the ng g–1 range with detection limits of less than 10 ng g–1 for Ca, Cr, Mn, Zr, Ba, and Pb and in the range of 120–220 ng g–1 for Na, Al, and Ti. The distance between the laser focal point and the sample surface has a significant influence on signal intensity and precision, both of which can be improved by a factor of approximately two by focusing the laser 15 mm behind the sample surface. Aerosol moistening reduced the standard deviation of the signal intensity by a factor of 2–4. Signal instability, which resulted from different ablation rates or variations in the transmission of the mass spectrometer, were compensated by use of the simultaneously measured SiAr+ ion as an internal standard. Under these conditions precision was usually better than 5% RSD. The results were compared with those obtained by use of a commercial LA–ICP–MS system. With this instrumentation linear calibration curves were achieved for three elements only (Al, Ti, and Pb), showing that LA–ICP–MS is less appropriate for bulk analysis in the ng g–1 range.  相似文献   

17.
A method for the analysis of several macrolide and ionophore antibiotics as well as tiamulin in liquid manure was developed. Reversed-phase liquid chromatography and atmospheric pressure chemical ionisation (APCI) tandem mass spectrometry was used for detection.High-performance liquid chromatographic (HPLC) separation of the antibiotics was achieved in 35 min. The analytes were extracted with ethyl acetate and the extracts were cleaned up by solid-phase extraction on a diol SPE cartridge. Recovery experiments with spiked liquid manure concentrations varying from 6 to 2,000 microg kg(-1) gave constant recovery rates. The recovery rates for the macrolides erythromycin, roxithromycin and oleandomycin were 75-94%, that for the ionophore salinomycin was 119%, while that for the pleuromutilin tiamulin was 123%, when using a macrolide internal standard. The relative standard deviation was found to be 15-36% and the limits of detection were 0.4-11.0 micro g kg(-1).The maximum concentrations found in manure samples were 43 micro g kg(-1) for tiamulin and 11 micro g kg(-1) for salinomycin.  相似文献   

18.
A rapid method was developed for the determination of pentachloronitrobenzene (PCNB) and its metabolites pentachloroaniline, pentachlorothioanisole residues in ginseng. Extraction and clean-up were carried out in a single step and analysis was accomplished by gas chromatography–mass spectrometry with multiple reaction monitoring. The main parameters affecting extraction yield and selectivity, such as type and amount of dispersant material, clean-up co-sorbent and extraction solvent were evaluated. The best results were obtained using 1 g ginseng, 2 g florisil as dispersant sorbent, 0.5 g neutral alumina as clean-up co-sorbent, and subsequent extraction with 10 mL acetone–n-hexane (5:5, v/v) with assisted sonication and repeated with another 5 mL of the same solvent mixture. The method was validated by analysis of ginseng samples fortified at different concentration levels (0.01–0.10 mg kg?1). Average recoveries (n = 5) ranged from 85 to 95% with relative standard deviation between 2.5 and 11.2%. Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. The detection limits ranged from 0.2 to 0.9 µg kg?1 in ginseng. The method was applied to the analysis of PCNB and its metabolite residues in commercial ginseng samples.  相似文献   

19.
A simple and specific method for the simultaneous determination of eleutherosides B and E in powdered rhizomes of Eleutherococcus senticosus extract and in solid and liquid dietary supplements was developed and validated. E. senticosus extracts, often mixed with other plants or herbal extracts, are widely used in food supplements because of the tonic and adaptogenic activities referred to the eleutherosides B and E. In this study, samples were analyzed by a liquid chromatography-electrospray tandem mass spectrometry (LC–ESI-MS/MS) method operated in single reaction monitoring (SRM). Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. LOD and LOQ values were fixed at 3 μg L?1 and 10 μg L?1, respectively, whereas linearity was established within 10–1,000 μg L?1 range for both compounds. Good precision was obtained for both eleutherosides in terms of intra-day precision (RSD % lower than 4 %) and inter-day precision (RSD % lower than 6 %). Good percentage recoveries were obtained for both eleutherosides (91.5–103.6 %). Finally, the developed method was successfully applied to analyze a number of solid and liquid commercial dietary supplements containing E. senticosus extracts, also mixed with other herbal extracts.  相似文献   

20.
Determination of chlormequat in pig serum and sow milk by LC–MS/MS   总被引:1,自引:0,他引:1  
Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC–MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol–water–acetic acid, centrifuged, filtrated and determined by LC–MS/MS. The mean recoveries were in the range 80–110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g−4.0 ng/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号