首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid, sensitive, and simple ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) method for the determination of udenafil and its active metabolite, DA-8164, in human plasma and urine using sildenafil as an internal standard (IS) was developed and validated. Udenafil, DA-8164 and IS from a 100 microL aliquot of biological samples were extracted by protein precipitation using acetonitrile. Chromatographic separation was carried on an Acquity UPLC BEH C(18) column (50 x 2.1 mm, i.d., 1.7 microm) with an isocratic mobile phase consisting of acetonitrile and containing 0.1% formic acid (75:25, v/v) at flow rate of 0.4 mL/min, and total run time was within 1 min. Detection and quantification was performed by the mass spectrometer using multiple reaction-monitoring mode at m/z 517 --> 283 for udenafil, m/z 406 --> 364 for DA-8164 and m/z 475 --> 100 for IS. The assay was linear over a concentration range of 1-600 ng/mL with a lower limit of quantification of 1 ng/mL in both human plasma and urine. The coefficient of variation of this assay precision was less than 13.7%, and the accuracy exceeded 92.0%. This method was successfully applied for pharmacokinetic study after oral administration of udenafil 100 mg to healthy Korean male volunteers.  相似文献   

2.
A high-performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of muraglitazar, a novel alpha/gamma, dual PPAR activator, in monkey plasma. The method utilized trazodone as the internal standard (IS). The extraction scheme involved a simple protein precipitation procedure with the use of a mixture of acetonitrile and methylene chloride. Separation was carried out on a BDS Hypersil C(18) analytical column (2 x 50 mm, 3 microm) and an effective chromatographic separation of muraglitazar (3.31 min) and trazadone (2.27 min) was achieved at a ssow rate of 0.3 mL/min. The mobile phase, used in an isocratic mode, consisted of 90% A (acetonitrile: 0.1% formic acid, 50:50 v/v) and 10% B (acetonitrile: 0.1% formic acid, 95:5 v/v). Detection of muraglitazar and trazodone was by positive ion turbo-ion spray mass spectrometry in the SIM mode. The mass spectrometer was programmed to admit the protonated molecules at m/z 372.0 (IS) and m/z 517.1 (muraglitazar). The standard curve, which ranged from 2 to 500 ng/mL, was fitted to a 1/x weighted linear regression model. The between run precision and within-run precision values of the assay was within 6.2% RSD. The assay accuracy was within 10.0% of the nominal values of the range of QC samples (6.0-400 ng/mL). At the lower limit of quantitation (LLQ) of 2 ng/mL, the deviation of the predicted concentrations from the nominal value of LLQ samples (n = 6) were within +/-16.6%. Muraglitazar was stable in monkey K(3)EDTA plasma for at least three freeze-thaw cycles. The processed samples (spiked samples) were stable for 48 h in auto-sampler at 10 degrees C. The average extraction recoveries of muraglitazar and IS were 83.3 and 91.9%, respectively. The assay was applied to delineate the pharmacokinetic disposition of muraglitazar in monkeys following a single oral dose.  相似文献   

3.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

4.
Hu W  Xu Y  Liu F  Liu A  Guo Q 《Biomedical chromatography : BMC》2008,22(10):1108-1114
A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers.  相似文献   

5.
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human plasma, a new synthetic hydroxymethylglutaryl-coenzyme A reductase inhibitor. The analyte and internal standard (IS; cilostazol) were extracted by simple one-step liquid/liquid extraction with ether. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The chromatographic separation was performed on an Atlantis C18 column (2.1 mm x 150 mm, 5.0 microm) with a mobile phase consisting of 0.2% formic acid/methanol (30:70, v/v) at a flow rate of 0.20 mL/min. The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 482 --> 258 and m/z 370 --> 288. The areas of peaks from the analyte and the IS were used for quantification of rosuvastatin. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification (LLOQ) was 0.2 ng/mL and the assay exhibited a linear range of 0.2-50.0 ng/mL and gave a correlation coefficient (r) of 0.9991 or better. Quality control samples (0.4, 8, 25 and 40 ng/mL) in six replicates from three different runs of analysis demonstrated an intra-assay precision (RSD) 7.97-15.94%, an inter-assay precision 3.19-15.27%, and an overall accuracy (relative error) of < 3.7%. The method can be applied to pharmacokinetic or bioequivalence studies of rosuvastatin.  相似文献   

6.
A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 microL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 microL injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-microm particles (4.6 mmx50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4-->297 (4-oxo-retinoic acids), 301.2-->205 (retinoic acids), 305.0-->209 (IS) and 269.2-->93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples.  相似文献   

7.
A simple, sensitive, selective, and rapid high-performance liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of naratriptan, using sumatriptan as internal standard (IS). The method included liquid-liquid extraction of naratriptan and IS with methyl-tert-butyl ether and dichloromethane mixture from 100 μL human plasma. The chromatographic separation is achieved on ACE C18 (50 mm × 2.1 mm, 5 μm) analytical column under isocratic conditions, using 0.1% acetic acid and acetonitrile (15:85, v/v) at a flow-rate of 0.4 mL/min. The precursor → product ion transitions for naratriptan (m/z 336.10 → 98.06) and IS (m/z 296.09 → 251.06) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and positive ion mode. The linearity of the method for naratriptan is determined in the range of 103-20690 pg/mL with the analysis time of 1.5 min. The method is fully validated according to USFDA guidelines. A systematic post-column infusion study is conducted for ion-suppression due to endogenous matrix components. The process efficiency of analyte (96%) and IS (93%) from spiked plasma samples was consistent and reproducible. The application of the method is demonstrated by a bioequivalence study of 2.5 mg naratriptan tablet formulation in 31 healthy volunteers under fasting conditions.  相似文献   

8.
A rapid and sensitive quantitative assay method was developed for determining ribavirin pharmacokinetic in human plasma. The chromatographic separation was achieved within 4.5 min using a SinoChrom ODS-BP column (4.6 x 150 mm, 5 microm) with acetonitrile-water (1 mmol/L ammonium acetate buffer, 0.1% formic acid; 15:85, v/v) at a constant flow rate of 0.8 mL/min. The MRM pairs were m/z 245.2 --> m/z 113.1 for ribavirin and m/z 226.1 --> m/z 152.1 for acyclovir (internal standard), respectively, with dwell times of 200 ms for each transition. The results showed calibration curve for ribavirin was linear over a concentration range of 1-1000 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL ribavirin. Twenty healthy volunteers received a 300 mg oral dose of ribavirin. Blood samples were then collected up to 120 h postdosing. All plasma data were comodeled for ribavirin by using noncompartmental modeling. The single dose of ribavirin was well tolerated and no serious adverse effects occurred. The mean time to maximum concentration was about 1.25 h. The mean maximum concentration of drug in plasma for oral ribavirin was 250 ng/mL. The mean elimination half-life was 43.6 h. The present study describes a simple, specific, sensitive HPLC-MS/MS method for measuring plasma drug concentration and analyzing human pharmacokinetics of ribavirin.  相似文献   

9.
An improved liquid chromatographic tandem mass spectrometric method for the determination of glimepiride in human plasma has been developed and fully validated. The article describes in detail the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using liquid--liquid extraction with a mixture of 1-chlorobutane-isopropanol-ethyl acetate (88:2:10, v/v/v). The chromatographic separation was performed on a reversed-phase Hypersil ODScolumn (250 x 4.6 mm i.d.; 5 microm particle size) using a mobile phase consisting of formic acid 0.05 M-acetonitrile (28:72, v/v), pumped at a flow rate of 0.3 ml min(-1) heated to 25 degrees C. The analytes were detected using an API 3000 triple quadrupole mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. Tandem mass spectrometric detection enabled the quantitation of glimepiride down to 0.50 ng mL(-1). Calibration graphs were linear (r better than 0.998, n=1), in concentration range 0.50--1000 ng mL(-1), and the intra- and inter- day RSD values were less than 10.37 and 11.55% for glimepiride. The method was successfully applied to a kinetic study in order to assess the main pharmacokinetic parameters of glimepiride.  相似文献   

10.
A selective, sensitive and high-throughput ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method has been developed and validated for the quantification of HIV-protease inhibitors ritonavir (RTV), lopinavir (LPV) and indinavir (IDV) in human plasma. Sample clean-up involved protein precipitation of both drugs and fluconazole used as internal standard from 100 μL human plasma. All the analytes were chromatographically separated on a Waters Acquity UPLC BEH C18 (2.1 × 50 mm, 1.7 μm particle size) analytical column using 0.1% formic acid and methanol (40:60, v/v) as the mobile phase. The parent → product ion transitions for ritonavir (m/z 721.40→ 296.10), lopinavir (m/z 629.40→ 447.40) and indinavir (m/z 614.4→ 421.0) IS (m/z 307.10 → 220.10) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive ion mode. The method was validated over the concentration range of 30-15,000 ng/mL for LPV and IDV and 3-1500 ng/mL for RTV. The method was successfully applied to a pilot bioequivalence study in 36 healthy human subjects after oral administration of lopinavir 200 mg and ritonavir 50 mg tablet formulation under fasting conditions.  相似文献   

11.
A new method for the determination of anti-diabetic drugs metformin and rosiglitazone based on the use of capillary electrophoresis with electrospray mass spectrometry was developed. The proposed method allowed their separation within 11 min by using 50 mM formic acid at +20 kV. Positive electrospray ionization and selected ion monitoring [M+H](+) of metformin (m/z=130) and rosiglitazone (m/z=358) were performed. Several important experimental parameters influencing electrospray ionization of metformin and rosiglitazone were studied. The final composition of sheath liquid was water/methanol/formic acid (50:49.5:0.5, v/v/v), at a flow rate of 2 μL/min. The developed method was applied for the determination of metformin and rosiglitazone simultaneously in human serum after protein precipitation with acetonitrile. The limits of detection of developed method were 4.42 and 2.14 ng/mL for rosiglitazone and for metformin, respectively, which is sufficient for therapeutic serum concentration levels monitoring for both studied drugs.  相似文献   

12.
A sensitive and rapid liquid chromatographic/tandem mass spectrometric method was developed and validated for the determination of sertraline in human plasma. The analyte and internal standard (IS, diphenhydramine) were extracted with 3 mL of diethyl ether/dichloromethane (2:1, v/v) from 0.25 mL plasma, then separated on a Zorbax Eclipse XDB C18 column using methanol/water/formic acid (75:25:0.1, v/v/v) as the mobile phase. The triple quadrupole mass spectrometry was applied via an atmospheric pressure chemical ionization (APCI) source for detection. The fragmentation pattern of the protonated sertraline was elucidated with the aid of product mass spectra of isotopologous peaks. Quantification was performed using selected reaction monitoring of the transitions of m/z 306 --> 159 for sertraline and m/z 256 --> 167 for the IS. The method was linear over the concentration range of 0.10-100 ng/mL. The intra-day and inter-day precisions, expressed by relative standard deviation, were both less than 6.7%. Assay accuracies were within +/-6.9% as terms of relative error. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.10 ng/mL with a precision of 8.3% and an accuracy of 9.6%. The validated method has been successfully applied for the pharmacokinetic study and bioequivalence evaluation of sertraline in 18 healthy volunteers after a single oral administration of 50 mg sertraline hydrochloride tablets.  相似文献   

13.
A simple, sensitive and reliable LC–MS/MS method was developed and validated for the quantification of anemoside B4, a potential antiviral constituent isolated from Pulsatilla chinensis in rat plasma, tissue, bile, urine and feces. All biological samples were prepared by protein precipitation method, and ginsenoside‐Rg1 was chosen as the internal standard (IS). The analyte and IS were separated using a C18 column (2.1 × 50 mm, 1.8 μm) and a mobile phase consisting of 0.1% formic acid in water (v /v) and acetonitrile running at a flow rate of 0.2 mL/min for 5 min. The multiple reaction monitoring transitions were monitored at m /z 1219.5–749.5 for anemoside B4 and 845.4–637.4 for ginsenoside‐Rg1 in electrospray ionization negative mode. The calibration curve was linear in the range of 10–2000 ng/mL for all biological matrices with a lower limit of quantification of 10 ng/mL. The validated method was successfully applied to a pharmacokinetics, tissue distribution and excretion study. These preclinical data will be beneficial for further development of anemoside B4 in future studies.  相似文献   

14.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

15.
The current study aims to develop a specific and sensitive LC-MS/MS method for determination of bis(7)-tacrine (B7T) in rat plasma. A 100 microL plasma sample was extracted with ethyl acetate. B7T and the internal standard (IS), pimozide, in the samples were then analyzed with LC-MS/MS in positive electrospray ionization condition. Chromatographic separation of B7T and IS was achieved in a C(18) reversed-phase HPLC column (150 x 2.1 mm i.d.) by isocratic elution with a mobile phase consisting of 0.05% formic acid in water and acetonitrile (1:1, v/v) at a flow rate of 0.35 mL/min. Multiple-reaction monitoring (MRM) mode was employed to measure the ion transitions: m/z 247 to 197 for B7T and m/z 462 to m/z 328 for IS, respectively. The method was linear over the studied ranges of 100-5000 and 10-100 ng/mL. The intra-day and inter-day variations of the analysis were less than 6.8% with standard errors less than 9.0%. The detection limit of B7T in rat plasma was 1 ng/mL. The developed method was successfully applied to the pharmacokinetic study of B7T after intravenous administration of 1 mg/kg B7T and further proved to be readily utilized for determination of B7T in rat plasma samples.  相似文献   

16.
Betahistine is widely used for the treatment of vertigo. Owing to first‐pass metabolism, 2‐pyridyl acetic acid (2PAA, major metabolite of betahistine) was considered as surrogate for quantitation. A specific and sensitive LC–MS/MS method was developed and validated for quantitation of 2PAA using turbo‐ion spray in a positive ion mode. A solid‐phase extraction was employed for the extraction of 2PAA and 2PAA d6 (IS) from human plasma. Chromatographic separation of analytes was achieved using an ACE CN, 5 μm (50 × 4.6 mm) column with a gradient mobile phase comprising acetonitrile–methanol (90:10% v /v) and 0.7% v/v formic acid in 0.5 mm ammonium trifluoroacetate in purified water (100% v/v). The retention times of 1.15 and 1.17 min for 2PAA and internal standard, respectively, were achieved. Quantitation of 2PAA and internal standard was achieved by monitoring multiple reaction monitoring transition pairs (m /z 138.1 to m /z 92.0 and m /z 142.1 to m /z 96.1, respectively). The developed method was validated for various parameters. The calibration curves of 2PAA showed linearity from 5.0 to 1500 ng/mL, with a lower limit of quantitation of 5.0 ng/mL. The bias and precision for inter‐ and intra‐batch assays were <10%. The developed method was used to support clinical sample analysis.  相似文献   

17.
A liquid chromatography-electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous quantitation of nicorandil and its denitrated metabolite, N-(2-hydroxyethyl)-nicotinamide, in rat plasma. After a liquid-liquid extraction step, chromatographic separation was performed on a ShinPack C(18) column with an isocratic mobile phase composed of methanol and 2 mM aqueous ammonium acetate containing 0.03% (v/v) formic acid (33:67 v/v). Procainamide was used as an internal standard (IS). Selected reaction monitoring was performed using the transitions m/z 212 → m/z 135, m/z 166 → m/z 106 and m/z 236 → m/z 163 to quantify nicorandil, its denitrated metabolite and IS, respectively. Calibration curves were constructed over the range of 5-15,000 ng.ml(-1) for both nicorandil and its metabolite. The mean relative standard deviation (RSD%) values for the intra-run precision were 5.4% and 7.3% and for the inter-run precision were 8.5% and 7.3% for nicorandil and its metabolite, respectively. The mean accuracy values were 100% and 95% for nicorandil and its metabolite, respectively. No matrix effect was detected in the samples. The validated method was successfully applied to a pharmacokinetic study after per os administration of nicorandil in rats.  相似文献   

18.
The aim of this study was to improve and validate a more stable and less time‐consuming method based on liquid chromatography and tandem mass spectrometry (LC‐ MS/MS) for the quantitative measurement of imatinib and its metabolite N‐ demethyl‐imatinib (NDI) in human plasma. Separation of analytes was performed on a Waters XTerra RP18 column (50 × 2.1 mm i.d., 3.5 μm) with a mobile phase consisting of methanol–acetonitrile–water (65:20:15, v /v/v) with 0.05% formic acid at a flow‐rate of 0.2 mL/min. The Quattro MicroTM triple quadruple mass spectrometer was operated in the multiple‐reaction‐monitoring mode via positive electrospray ionization interface using the transitions m /z 494.0 → 394.0 for imatinib, m /z 479.6 → 394.0 for NDI and m /z 488.2 → 394.0 for IS. The method was linear over 0.01–10 μg/mL for imatinib and NDI. The intra‐ and inter‐day precisions were all <15% in terms of relative standard deviation, and the accuracy was within ±15% in terms of relative error for both imatinib and NDI. The lower limit of quantification was identifiable and reproducible at 10 ng/mL. The method was sensitive, specific and less time‐consuming and it was successfully applied in gastrointestinal stromal tumor patients treated with imatinib.  相似文献   

19.
A simple, rapid and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of angiotensin‐converting enzyme inhibitor, moexipril, in human plasma. Benazepril was used as an internal standard (IS). Analyte and IS were extracted from the human plasma by liquid–liquid extraction technique using ethyl acetate. The reconstituted samples were chromatographed on a C18 column by using a mixture of methanol and 0.1% formic acid buffer (85:15, v/v) as the mobile phase at a flow rate of 0.5 mL/min. The calibration curve obtained was linear (r ≥ 0.99) over the concentration range of 0.2–204 ng/mL. The multiple reaction‐monitoring mode was used for quantification of ion transitions at m/z 499.4/234.2 and 425.2/351.1 for moexipril and IS, respectively. The results of the intra‐ and inter‐day precision and accuracy studies were well within the acceptable limits. A run time of 2.0 min for each sample made it possible to analyze more than 400 plasma samples per day. The proposed method was found to be applicable to clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and specific LC–MS/MS assay for determination of β ‐eudesmol in rat plasma was developed and validated. After liquid–liquid extraction with ethyl ether , the analyte and IS were separated on a Capcell Pak C18 column (50 × 2.0 mm, 5 μm) by isocratic elution with acetonitrile—water–formic acid (77.5:22.5:0.1, v /v/v) as the mobile phase at a flow rate of 0.4 mL/min. An ESI source was applied and operated in positive ion mode; a selected reaction monitoring scan was used for quantification by monitoring the precursor–product ion transitions of m/z 245.1 → 163.1 for β ‐eudesmol and m/z 273.4 → 81.2 for IS. Good linearity was observed in the concentration range of 3–900 ng/mL for β ‐eudesmol in rat plasma. Intra‐ and inter‐day precision and accuracy were both within ±14.3%. This method was applied for pharmacokinetic studies after intravenous bolus of 2.0 mg/kg or intragastric administration of 50 mg/kg β ‐eudesmol in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号