首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ionic liquid-based dispersive liquid-liquid micro-extraction (IL-DLLME) was coupled with high-performance liquid chromatography-ultraviolet (HPLC-UV) for the determination of four phthalate esters, including butyl benzyl phthalate, di-n-butyl phthalate, dicyclohexyl phthalate and bis(2-ethylhexyl) phthalate in water samples. The mixture of ionic liquid (IL) and dispersive solvent was rapidly injected into 10 mL aqueous sample. Then, IL phase was separated by centrifugation and was determined by high-performance liquid chromatography-ultraviolet. The factors influencing the extraction efficiency, such as type and volume of IL, disperse solvent, extraction time, centrifuging time and ionic strength, were investigated and optimized. Under the optimized conditions, the extraction recoveries by the proposed ionic liquid-based dispersive liquid-liquid micro-extraction for the four phthalates ranged from 83.0 to 91.7%. The relative standard deviations were between 7.8 and 15%. The limits of quantification for four phthalates were between 10.6 and 28.5 μg/L. The proposed method was successfully applied for the analysis of PAEs in tap, lake and treated wastewater samples.  相似文献   

2.
Ultrasound-assisted ionic liquid dispersive liquid-phase micro-extraction was developed for the determination of four aromatic amines such as 2,4-dichloroaniline, 1-naphthylamine, 6-chloroanline and N,N-dimethylaniline. High-performance liquid chromatography coupled with UV detector was used for the determination of aromatic amines. In the novel procedure, 1-hexyl-3-methylimidazolium hexafluorophosphate [C6MIM] [PF6] was dispersed into the aqueous sample solution as fine droplets by ultrasonication, and which promoted the analytes more easily migrate into the ionic liquid phase. Variable affecting such as the volume of [C6MIM] [PF6], sample pH, ultrasonication time, extraction time, centrifuging time have been investigated in detail. The proposed method has been found to have excellent detection sensitivity with limits of detection (LOD, S/N = 3) in the range of 0.17–0.49 μg L−1 and precisions in the range of 2.0–6.1% (RSDs, n = 6). This method has been also successfully applied to analyze the real water samples and good spiked recoveries over the range of 92.2–119.3% were obtained.  相似文献   

3.
Ionic liquid-based dispersive liquid-liquid microextraction was developed for the extraction and preconcentration of aromatic amine from environmental water. A suitable mixture of extraction solvent (100 μL, 1-butyl-3-methylimidazolium hexafluorophoshate) and dispersive solvent (750 μL, methanol) were injected into the aqueous samples (10.00 mL), forming a cloudy solution. After centrifuging, enriched analytes in the sediment phase were determined by HPLC-UV. The effect of various factors, such as the extraction and dispersive solvent, sample pH, extraction time and salt effect were investigated. Under optimum conditions, enrichment factors for 2-anilinoethanol, o-chloroaniline and 4-bromo-N,N-dimethylaniline were above 50 and the limits of detection (LODs) were 0.023, 0.015 and 0.026 ng/mL, respectively. Their linear ranges were 0.8-400 ng/mL for 2-anilinoethanol, 0.5-200 ng/mL for o-chloroaniline and 0.4-200 ng/mL for 4-bromo-N,N-dimethylaniline, respectively. Relative standard deviations (RSDs) were below 5.0%. The relative recoveries from samples of environmental water were in the range of 82.0-94.0%. Compared with other methods, dispersive liquid-liquid microextraction is simple, rapid, sensitive and economical.  相似文献   

4.
In the present study, dispersive liquid-liquid microextraction (DLLME) using an ionic liquid (IL) as the extractant was successfully developed to extract four benzophenone-type UV filters from the different water matrices. Orthogonal array experimental design (OAD), based on five factors and four levels (L(16)(4(5))), was employed to optimize IL-dispersive liquid-liquid microextraction procedure. The five factors included pH of sample solution, the volume of IL and methanol addition, extraction time and the amount of salt added. The optimal extraction condition was as follows. Sample solution was at a pH of 2.63 in the presence of 60 mg/mL sodium chloride; 30 μL IL and 15 μL methanol were used as extractant and disperser solvent, respectively; extraction was achieved by vortexing for 4 min. Using high-performance liquid chromatography-UV analysis, the limits of detection of the target analytes ranged between 1.9 and 6.4 ng/mL. The linear ranges were between 10 or 20 ng/mL and 1000 ng/mL. This procedure afforded a convenient, fast and cost-saving operation with high extraction efficiency for the model analytes. Spiked waters from two rivers and one lake were examined by the developed method. For the swimming pool water, the standard addition method was employed to determine the actual concentrations of the UV filters.  相似文献   

5.
In this work, a simple, rapid and sensitive sample pretreatment technique, dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD), has been developed to determine carbamate (carbaryl) and organophosphorus (triazophos) pesticide residues in water and fruit juice samples. Parameters, affecting the DLLME performance such as the kind and volume of extraction and dispersive solvents, extraction time and salt concentration, were studied and optimized. Under the optimum extraction conditions (extraction solvent: tetrachloroethane, 15.0 μL; dispersive solvent: acetonitrile, 1.0 mL; no addition of salt and extraction time below 5 s), the performance of the proposed method was evaluated. The enrichment factors for the carbaryl and triazophos were 87.3 and 275.6, respectively. The linearity was obtained in the concentration range of 0.1-1000 ng mL−1 with correlation coefficients from 0.9991 to 0.9999. The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.3 to 16.0 pg mL−1. The relative standard deviations (RSDs, for 10 ng mL−1 of carbaryl and 20 ng mL−1 of triazophos) varied from 1.38% to 2.74% (n = 6). The environmental water (at the fortified level of 1.0 ng mL−1) and fruit juice samples (at the fortified level of 1.0 and 5.0 ng mL−1) were successfully analyzed by the proposed method, and the relative recoveries of them were in the range of 80.4-114.2%, 89.8-117.9% and 86.3-105.3%, respectively.  相似文献   

6.
In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4-aminobiphenyl in aqueous matrices. After extraction the ionic liquid (IL) phase was injected directly into the high performance liquid chromatography (HPLC) system for determination. Some parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. The limits of detection (LOD, S/N = 3) for the four analytes were in the range of 0.45-2.6 μg L^-1. The relative standard deviations (R.S.D., n = 6) were in the range of 6.2-9.8%. This method was applied for the analysis of the real water samples. The recoveries ranged from 93.4 to 106.4%. The main advantages of the method are high speed, high recovery, good repeatability and volatile organic solvent-free.  相似文献   

7.
A rapid dispersive liquid-liquid micro-extraction (DLLME) methodology based on the application of 1-hexylpyridinium hexafluorophosphate [C6py][PF6] ionic liquid (IL) as an extractant solvent was applied for the pre-concentration of trace levels of cobalt prior to determination by flame atomic absorption spectrometry (FAAS). 1-Phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) was employed as a chelator forming a Co-PMBP complex to extract cobalt ions from aqueous solution into the fine droplets of [C6py][PF6]. Some effective factors that influence the micro-extraction efficiency include the pH, the PMBP concentration, the amount of ionic liquid, the ionic strength, the temperature and the centrifugation time which were investigated and optimized. In the optimum experimental conditions, the limit of detection (3s) and the enrichment factor were 0.70 μg L−1 and 60, respectively. The relative standard deviation (RSD) for six replicate determinations of 50 μg L−1 Co was 2.36%. The calibration graph using the pre-concentration system was linear at levels 2–166 μg L−1 with a correlation coefficient of 0.9982. The applicability of the proposed method was evaluated by the determination of trace amounts of cobalt in several water samples.   相似文献   

8.
A novel method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. A mixture of extraction solvent (41 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) were rapidly injected into 5.0 mL aqueous sample for the formation of cloudy solution, the analytes in the sample were extracted into the fine droplets of CCl4. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 5 to 5000 ng mL−1 for target analytes. The enrichment factors for DMP, DEP and DnBP were 45, 92 and 196, respectively, and the limits of detection were 1.8, 0.88 and 0.64 ng mL−1, respectively. The relative standard deviations (R.S.D.) for the extraction of 10 ng mL−1 of phthalate esters were in the range of 4.3-5.9% (n = 7). Lake water, tap water and bottled mineral water samples were successfully analyzed using the proposed method.  相似文献   

9.
A new method was developed for determination of methomyl in water samples by combining a dispersive liquid-liquid microextraction (DLLME) technique with HPLC-variable wavelength detection (VWD). In this extraction method, 0.50 mL of methanol (as dispersive solvent) containing 20.0 microL of tetrachloroethane (as extraction solvent) was rapidly injected by syringe into a 5.00-mL water sample containing the analyte, thereby forming a cloudy solution. After phase separation by centrifugation for 2 min at 4000 rpm, the enriched analyte in the settled phase (8 +/- 0.2 microL) was at the bottom of the conical test tube. A 5.0-microL volume of the settled phase was analyzed by HPLC-VWD. Parameters such as the nature and volume of the extraction solvent and the dispersive solvent, extraction time, and the salt concentration were optimized. Under the optimum conditions, the enrichment factor could reach 70.7 for a 5.00-mL water sample and the linear range, detection limit (S/N = 3), and precision (RSD, n = 6) were 3-5000 ng/mL, 1.0 ng/mL, and 2.6%, respectively. River and lake water samples were successfully analyzed by the proposed method. Comparison of this method with solid-phase extraction, solid-phase microextraction, and single-drop microextraction, indicates that DLLME combined with HPLC-VWD is a simple, fast, and low-cost method for the determination of methomyl, and thus has tremendous potential in trace analysis of methomyl in natural waters.  相似文献   

10.
Xu X  Su R  Zhao X  Liu Z  Li D  Li X  Zhang H  Wang Z 《Talanta》2011,85(5):2632-2638
A simple method based on simultaneous microwave-assisted derivatization and ionic liquid-based dispersive liquid-liquid microextraction (IL-based DLLME) is proposed for the derivatization, extraction and preconcentration of formaldehyde in beverage samples prior to the determination by high-performance liquid chromatography (HPLC). Formaldehyde was in situ derivatized with 2,4-dinitrophenylhydrazine (DNPH) and simultaneously extracted and preconcentrated by using microwave-assisted derivatization and IL-based DLLME in a single step. Several experimental parameters, including type and volume of extraction solvent, type and volume of disperser, microwave power and irradiation time, volume of DNPH, pH of sample solution, and ionic strength were evaluated. When the microwave power was 120 W, formaldehyde could be derivatized and extracted simultaneously only within 90 s. Under optimal experimental conditions, good linearity was observed in the range of 0.5-50 ng/mL with the correlation coefficient of 0.9965, and the limit of detection was 0.12 ng/mL. The proposed method was applied to the analysis of different beverage samples, and the recoveries of formaldehyde obtained were in the range of 84.9-95.1% with the relative standard deviations lower than 8.4%. The results showed that the proposed method was a rapid, convenient and feasible method for the determination of formaldehyde in beverage samples.  相似文献   

11.
The liquid-liquid microextraction (LLME) was developed for extracting sudan dyes from red wine and fruit juice. Room temperature ionic liquid was used as the extraction solvent. The target analytes were determined by high-performance liquid chromatography. The extraction parameters were optimized. The optimal conditions are as follows: volume of [C(6)MIM][PF(6)] 50 μL; the extraction time 10 min; pH value of the sample solution 7.0; NaCl concentration in sample solution 5%. The extraction recoveries for the analytes in red wine and fruit samples are 86.79-108.28 and 68.54-85.66%, whereas RSDs are 1.42-5.12 and 1.43-6.19%, respectively. The limits of detection and quantification were 0.428 and 1.426 ng/mL for sudan I, 0.938 and 3.127 ng/mL for sudan II, 1.334 and 4.445 ng/mL for sudan III, 1.454 and 4.846 ng/mL for sudan IV, respectively. Compared with conventional liquid-liquid extraction (CLLE) and ultrasonic extraction (UE), when LLME was applied, the sample amount was less (LLME: 4 mL; CLLE: 10 mL; UE: 10 mL), the extraction time was shorter (LLME: 15 min; CLLE: 110 min; UE: 50 min) and the extraction solvent amount was less (LLME: 0.05 mL IL; CLLE: 15 mL hexane; UE: 20 mL hexane). The proposed method offers a simple, rapid and efficient sample preparation for determining sudan dyes in red wine and fruit juice samples.  相似文献   

12.
The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 μL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals.Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 μg L−1 with a detection limit of 0.5 μg L−1. The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 μg L−1 of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 μg L−1 ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.  相似文献   

13.
This review aims to provide an overview of homogeneous liquid-liquid extraction (HLLE) and dispersive liquid-liquid microextraction (DLLME) methods and their potential use in inorganic analysis. Relevant applications to the determination of metal ions, metalloids and organometals are included. The phase separation mechanisms of these unconventional solvent extraction techniques are discussed. The new trends in the field of miniaturization and automation are presented, while proposing future trends and potential new areas for their application.  相似文献   

14.
A novel method for the determination of five carbamate pesticides(metolcarb,carbofuran,carbaryl,isoprocard and diethofencard)in water samples was developed by dispersive liquid-liquid microextraction(DLLME)coupled with high performance liquid chromatography-diode array detector(HPLC-DAD).Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results.Under the optimum conditions for the method,the calibration curve was linear in the c...  相似文献   

15.
A novel, simple and environmentally friendly procedure for copper determination has been developed. The method is based on the formation of an ion associate of Cu(I) with 1,3,3-trimethyl-2-[5-(1,3,3-trimethyl-1,3-dihydroindol-2-ylidene)-penta-1,3-dienyl]-3H-indolium (DIDC) in the presence of chloride ions as ligand, followed by dispersive liquid-liquid microextraction (DLLME) of the formed ion associate into organic phase and UV-Vis spectrophotometric detection. The following experimental conditions were used: pH 3, 0.24 mol L− 1 chloride ions, 0.06 mmol L− 1 DIDC. The effect of the nature of the extraction solvent, auxiliary solvent and disperser solvent used was studied. A mixture of amyl acetate, tetrachloromethane, and methanol in a 1:1:3 v/v/v ratio was selected for the DLLME procedure. The absorbance of the coloured extracts at 640 nm wavelength obeys Beer's law in the range 0.020-0.090 mg L− 1 of Cu. The limit of detection calculated from a blank test (n = 10) based on 3s is 0.005 mg L− 1 of Cu. The developed procedure was applied to the analysis of water samples. The suggested DLLME is compared with two procedures previously reported from our laboratory based on (1) conventional liquid-liquid extraction, and (2) sequential injection extraction performed in a dual-valve sequential injection system. The advantages and disadvantages of each method are discussed.  相似文献   

16.
In this article, a new ligandless dispersive liquid-liquid microextraction method has been developed for preconcentration of trace quantities of silver as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, like, extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, the calibration curve was linear in the range of 5.0 ng mL−1 to 2.0 μg mL−1 of silver with R2 = 0.9995 (n = 9) and detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 in original solution. The relative standard deviation for eight replicate determination of 0.5 μg mL−1 silver was ±1.5%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of silver in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of silver in standard and water samples with satisfactory results.  相似文献   

17.
An efficient and environmental friendly ionic liquid based dispersive liquid-liquid microextraction procedure was optimized for determination of rifaximin in rat serum by reverse phase high-performance liquid chromatography. The effect of ionic liquids, dispersive solvents, extractant/disperser ratio, and salt concentrations on sample recovery and enrichment factors were studied. Among the five ionic liquids studied in the present investigation, 1-butyl-3-methylimidazolium hexafluorophosphate was found to be most effective for extraction of rifaximin. The recovery was found to be more than 98% using 1-butyl-3-methylimidazolium hexafluorophosphate and methanol as extraction and dispersive solvents, at an extractant/disperser ratio of 0.43. The recovery was further enhanced to 99.5% by the addition of 5.0% NaCl solution. A threefold enhancement in detection limit was achieved when compared to protein precipitation. The ionic liquid containing the extracted rifaximin was directly injected into HPLC system. The linear relationship was observed in the range of 0.03-10.0 μg/mL with the correlation coefficient (r(2) ) 0.9998. Limits of detection and quantification were found to be 0.01 and 0.03 μg/mL, respectively. The relative standard deviation was 2.5%. The method was validated and applied to study pharmacokinetics of rifaxmin in rat serum.  相似文献   

18.
吴翠琴  雷金妹  李韵灵  王韵靓  陈迪云  龚剑 《色谱》2014,32(12):1362-1367
建立了一种基于离子液体的分散液液微萃取技术结合柱前荧光衍生高效液相色谱(IL-DLLME-HPLC-FL)对8种磺胺类药物进行检测的方法,并成功应用于实际环境水样的分析。实验考察了萃取参数对磺胺萃取效率的影响及衍生产物的稳定性。最佳实验条件:以40 μL [C6MIM]PF6]为萃取剂,0.1 mL丙酮为分散剂,对pH=4且不含NaCl的水溶液进行不超声的分散液液微萃取,并衍生化反应6 h。结果表明:在最佳实验条件下,该法在0.2~10 μg/L和10~500 μg/L两个浓度范围内线性良好,线性相关系数r ≥0.9989;检出限为0.08~0.5 μg/L (S/N=3)。对实验室自来水、湖水、珠江水、池塘水分别加标5、50、200 μg/L的回收率为87.2%~101.4%,相对标准偏差为3.7%~6.2%。该法环保、简便,可用于测定实际水样中磺胺类药物。  相似文献   

19.
In this article, a novel method termed as temperature-assisted ionic liquid dispersive liquid-liquid microextraction (TA IL-DLLME) combining high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones in Radix et Rhizoma Rhei samples. The ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) was used to replace volatile organic solvent as an extraction solvent for the extraction of anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) from Radix et Rhizoma Rhei. Several important parameters influencing the extraction efficiency of TA IL-DLLME such as the type and volume of extraction solvent and disperser solvent, sample pH, extraction time, extraction temperature, centrifugation time as well as salting-out effects were optimized. Under the optimal conditions, the spiked recovery for each analyte was in the range of 95.2-108.5%. The precisions of the proposed method were varied from 1.1% to 4.4% (RSD). All the analytes exhibited good linearity with correlation coefficients (r2) ranging from 0.9986 to 0.9996. The limits of detection for all target analytes were ranged from 0.50 to 2.02 μg L−1 (S/N = 3). The experimental results indicated that the proposed method was successfully applied to the analysis of anthraquinones in Radix et Rhizoma Rhei.  相似文献   

20.
Sereshti H  Khojeh V  Samadi S 《Talanta》2011,83(3):885-890
In this study, dispersive liquid-liquid microextraction (DLLME) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed for simultaneous preconcentration and trace determination of chromium, copper, nickel and zinc in water samples. Sodium diethyldithiocarbamate (Na-DDTC), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters of DLLME such as volume of extraction and disperser solvents, pH, concentration of salt and concentration of the chelating agent were studied by a (2f−1) fractional factorial design to identify the most important parameters and their interactions. The results showed that concentration of salt and volume of disperser solvent had no effect on the extraction efficiency. In the next step, central composite design was used to obtain optimum levels of effective parameters. The optimal conditions were: volume of extraction solvent, 113 μL; concentration of the chelating agent, 540 mg L−1; and pH, 6.70. The linear dynamic range for Cu, Ni and Zn was 1-1000 μg L−1 and for Cr was 1-750 μg L−1. The correlation coefficient (R2) was higher than 0.993. The limits of detection were 0.23-0.55 μg L−1. The relative standard deviations (RSDs, C = 200 μg L−1, n = 7) were in the range of 2.1-3.8%. The method was successfully applied to determination of Cr, Cu, Ni and Zn in the real water samples and satisfactory relative recoveries (90-99%) were achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号