首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The enrichment and processing of proteomic samples prior to multi-dimensional chromatography remain a challenge in ‘gel-free’ proteomics. We previously reported the development of a microfluidic device called the “proteomic reactor” that relied on enriching proteins by using strong cation exchange (SCX) followed by trypsin digestion in an interstitial volume as little as 50 nL. Here, we report a novel proteomic reactor that is based on polymeric strong anion exchange (SAX) material to analyse proteomic samples. We also compare the performance of the SAX proteomic reactor to our previously reported SCX proteomic reactor for analysing complex yeast proteomes. Our results indicate that the SAX protein reactor preferentially identifies more acidic peptides and proteins compared to the SCX reactor. We show that the SAX and SCX reactors are complementary and that their combination increases the number of unique peptides and proteins identified by 50%. Furthermore, we show that the number of protein identified can be increased further by up to 40% using different proteolytic enzymes on the proteomic reactor.  相似文献   

2.
Comprehensive proteomic analyses necessitate efficient separation of peptide mixtures for the subsequent identification of proteins by mass spectrometry (MS). However, digestion of proteins extracted from cells and tissues often yields complex peptide mixtures that confound direct comprehensive MS analysis. This study investigated a zwitterionic hydrophilic interaction liquid chromatography (ZIC‐HILIC) technique for the peptide separation step, which was verified by subsequent MS analysis. Human serum albumin (HSA) was the model protein used for this analysis. HSA was digested with trypsin and resolved by ZIC‐HILIC or conventional strong cation exchange (SCX) prior to MS analysis for peptide identification. Separation with ZIC‐HILIC significantly improved the identification of HSA peptides over SCX chromatography. Detailed analyses of the identified peptides revealed that the ZIC‐HILIC has better peptide fractionation ability. We further demonstrated that ZIC‐HILIC is useful for quantitatively surveying cell surface markers specifically expressed in undifferentiated embryonic stem cells. These results suggested the value of ZIC‐HILIC as a novel and efficient separation method for comprehensive and quantitative proteomic analyses. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
张政  唐涛  杨三东  孙元社  李彤  张维冰 《色谱》2017,35(5):526-532
基于蛋白质的尺寸及带电性质,将凝胶过滤色谱(GFC)与离子交换色谱(IEC)两种分离模式结合,采用双捕集柱接口构建了GFC/2×IEC二维液相色谱(2-D LC)分离系统,同时考虑离子交换色谱分离蛋白质对等电点范围的限制,进一步结合中心切割平行柱的方法实现对蛋白质的全二维分离。为与后续蛋白质在线酶解、多肽分离及质谱鉴定匹配,系统中采用常规柱以保证蛋白质质谱鉴定对样品量的要求,3种常规分离柱分别选用凝胶过滤色谱柱TSK-GEL G3000SW_(XL)(300 mm×7.8 mm,5μm)、强阴离子交换色谱柱Hypersil SAX(100 mm×4.6 mm,10μm)和强阳离子交换色谱柱Hypersil SCX(100 mm×4.6 mm,10μm)。最终以酵母细胞蛋白质提取液为样品,对构建的二维系统加以评价,在总蛋白质浓度13.5 mg/mL、上样体积100μL的条件下,将第一维分离等时间切割17次,并将切割馏分全部导入第二维继续分离,二维系统在148 min内获得的总峰容量达到884。说明所构建的系统可以用于蛋白质的在线全二维分离。  相似文献   

4.
In this study, the advantages of carrying out the analysis of peptides and tryptic digests of proteins under gradient elution conditions at pH 6.5 by reversed-phase liquid chromatography (RP-HPLC) and in-line electrospray ionisation mass spectrometry (ESI-MS) are documented. For these RP separations, a double endcapped, bidentate anchored n-octadecyl wide pore silica adsorbent was employed in a capillary column format. Compared to the corresponding analysis of the same peptides and protein tryptic digests using low pH elution conditions for their RP-HPLC separation, this alternative approach provides improved selectivity and more efficient separation of these analytes, thus allowing a more sensitive identification of proteins at different abundance levels, i.e. more tryptic peptides from the same protein could be confidently identified, enabling higher sequence coverage of the protein to be obtained. This approach was further evaluated with very complex tryptic digests derived from a human plasma protein sample using an online two-dimensional (2D) strong cation-exchange (SCX)-RP-HPLC-ESI-MS/MS system. Again, at pH 6.5, with mobile phases of different compositions, improved chromatographic selectivities were obtained, concomitant with more sensitive on-line electrospray ionisation tandem mass spectrometric (ESI-MS/MS) analysis. As a consequence, more plasma proteins could be confidently identified, highlighting the potential of these RP-HPLC methods with elution at pH 6.5 to extend further the scope of proteomic investigations.  相似文献   

5.
Microchip-based proteomic analysis requires proteolytic digestion of proteins in microdevices. Enzyme reactors in microdevices, fabricated in glass, silicon, and PDMS substrates, have recently been demonstrated for model protein digestions. The common approach used for these enzyme reactors is employment of a syringe pump(s) to generate hydrodynamic flow, driving the proteins through the reactors. Here we present a novel approach, using electroosmotic flow (EOF) to electrokinetically pump proteins through a proteolytic system. The existence of EOF in the proteolytic system packed with immobilized trypsin gel beads was proven by imaging the movement of a neutral fluorescent marker. Digestions of proteins were subsequently carried out for 12 min, and the tryptic peptides were analyzed independently using capillary electrophoresis (CE) and MALDI-TOF mass spectrometry (MS). The results from CE analysis of the tryptic peptides from the EOF-driven proteolytic system and a conventional water bath digestion were comparable. MALDI-TOF MS was used to identify the parent protein and the tryptic peptides using MS-Fit database searching. The potential utility of the EOF-driven proteolytic system was demonstrated by direct electro-elution of proteins from an acrylamide gel into the proteolytic system, with elution and tryptic digestion achieved in a single step. The EOF-driven proteolytic system, thus, provides a simple way to integrate protein digestion into an electrophoretic micro total analysis system for protein analysis and characterization.  相似文献   

6.
We have developed an on-line strong cation exchange (SCX)-ESI-MS/MS platform for the rapid identification of proteins contained in mixtures. This platform consists of a SCX precolumn followed by a nanoflow SCX column on-line with an electrospray ion trap mass spectrometer. We also used this platform to study the dynamics of peptide separation/extraction by SCX, in particular to understand the parameters affecting the performance of SCX in multidimensional chromatography. For example, we have demonstrated that the buffer typically used for tryptic digestion of protein mixtures can have a detrimental effect on the chromatographic behaviour of peptides during SCX separations, thereby affecting certain peptide quantitation approaches that rely on reproducible peptide fractionation. We have also demonstrated that band broadening results when a step (discontinuous) gradient approach is used to displace peptides from the SCX precolumn, reducing the separation power of SCX in multidimensional chromatography. In contrast, excellent chromatographic peak shapes are observed when a defined (continuous) gradient is used. Finally, using a tryptic digest of a protein extract derived from human K562 cells, we observed that larger molecular weight peptides are identified using this on-line SCX approach compared to the more conventional reverse phase (RP) LC/MS approach. Both methods used in tandem complement each other and can lead to a greater number of peptide identifications from a given sample.  相似文献   

7.
Steiner F  Scherer B 《Electrophoresis》2005,26(10):1996-2004
Peptide separations are regarded as a promising application of capillary electrochromatography (CEC) and, at the same time, a suitable model to elucidate its mixed separation mechanism when charged analytes are involved. In this paper, studies on the separation of small peptides (2-4 amino acids) on a Spherisorb octadecyl silane (ODS) phase at acidic pH and on a strong anion exchange (SAX)/C18 mixed mode phase at weakly basic pH are reported. For the ODS phase a comparison of CEC, capillary zone electrophoresis (CZE) and high-performance liquid chromatography (HPLC) under identical buffer/eluent conditions is presented. The predicted retention factors for CEC under the assumption of simple superposition of HPLC retention and CZE migration matched the measured results for the peptides that had small retention factors in HPLC. For both types of stationary phases, a variation of the acetonitrile content in the mobile phase led to a wide range of retention factors, including negative values when co-electroosmotic migration was dominant. Though both the ODS and the SAX/C18 phase offer unique advantages, the SCX/C18 phase at pH 9 provides more flexibility to alter separation selectivity for the selected peptides.  相似文献   

8.
通过在肽段的N端引入磺酸基,从而使含组氨酸的肽段与其他肽段在pH<3.0的条件下产生电荷差异,建立了一种基于强阳离子交换色谱(SCX)结合生物质谱富集鉴定含组氨酸肽段的方法,并以含有组氨酸的标准蛋白质为模型,进行了方法学考察。结果表明,经N端磺酸化后,含组氨酸的肽段能有效地被阳离子交换色谱富集,且在肽的N端引入磺酸基促进了肽的裂解,使之产生简单而信息丰富的二级质谱图,从而得到完美的质谱鉴定结果。这说明磺化修饰结合强阳离子交换色谱用于含组氨酸肽段的富集鉴定是可行的,且具有在蛋白质组研究中应用的潜力。  相似文献   

9.
Luo Q  Gu Y  Wu SL  Rejtar T  Karger BL 《Electrophoresis》2008,29(8):1604-1611
This study expands the capabilities for ultratrace proteomic analysis of our previous work by incorporating on-line sample desalting using a triphasic (RP/strong cation exchange (SCX)/micro-SPE) trapping column connected to a 3.2 m x 10 microm id poly(styrene-divinylbenzene) (PS-DVB) porous layer open tubular (PLOT) column. To minimize extra sample handling steps, C18 RP packing was incorporated in the capillary tubing upstream of the SCX column for the on-line desalting. For the micro-SPE column, a 50 microm id PS-DVB monolithic column was positioned downstream of the SCX column. High-performance separation was achieved on the PLOT column at a mobile phase flow rate of 20 nL/min. The sensitivity and high resolution capability of the new multidimensional platform was evaluated using an in-gel tryptic digested sample of a cervical cancer (SiHa) cell line. For the injected amount of 1200 cells ( approximately 500 ng), over 2700 peptides covering greater than 850 unique proteins were identified from the triphasic SCX/PLOT/MS analysis of a single SDS gel section (>40 kDa). The 2-D LC/MS platform demonstrated good separation performance, such that more than 85% of the identified peptides were detected from only one salt fraction. In a triplicate analysis of the above >40 kDa gel section, 4497 peptides and 1209 unique proteins were identified when applying stringent filtering criteria, with a false-positive rate of 2.4%. When all three SDS-PAGE gel sections of the lysed SiHa cells were analyzed, 5047 peptides and 1857 unique proteins (false-positive rate 1.8%), including cancer-related proteins such as MAP kinases, were identified.  相似文献   

10.
朱金霞  卜春苗  龚波林 《色谱》2006,24(2):129-134
采用分散聚合法制备小颗粒种子及“一步种子溶胀聚合”法成功地制备了粒径为3.0 μm的无孔单分散亲水性交联聚甲基丙烯酸环氧丙酯树脂,其表面经水解、环氧化、再水解后与氯磺酸反应,制备了一种新型的强阳离子交换色谱填料(SCX)。详细考察了该填料对标准蛋白质的分离性能及流动相中盐的种类、有机溶剂、流速等对蛋白质保留的影响。实验结果表明,在流速为4 mL/min时,采用线性梯度洗脱,1.0 min内可快速分离4种标准蛋白质,蛋白质的保留符合阳离子交换色谱规律。将SCX应用于快速纯化鸡蛋清中的溶菌酶和猪心中的细胞色素-C,取得了较好的效果。  相似文献   

11.
In this study, two mixed‐mode chromatography stationary phases (C8SAX and C8SCX) were evaluated and used to establish a two‐dimensional liquid chromatography system for the separation of traditional Chinese medicine. The chromatographic properties of the mixed‐mode columns were systematically evaluated by comparing with other three columns of C8, strong anion exchanger, and strong cation exchanger. The result showed that C8SAX and C8SCX had a mixed‐mode retention mechanism including electrostatic interaction and hydrophobic interaction. Especially, they were suitable for separating acidic and/or basic compounds and their separation selectivities could be easily adjusted by changing pH value. Then, several off‐line 2D‐LC systems based on the C8SAX in the first dimension and C8SAX, C8SCX, or C8 columns in the second dimension were developed to analyze a traditional Chinese medicine—Uncaria rhynchophylla. The two‐dimensional liquid chromatography system of C8SAX (pH 3.0) × C8SAX (pH 6.0) exhibited the most effective peak distribution. Finally, fractions of U. rhynchophylla prepared from the first dimension were successfully separated on the C8SAX column with a gradient pH. Thus, the mixed‐mode stationary phase could provide a platform to separate the traditional Chinese medicine in practical applications.  相似文献   

12.
High-resolution liquid chromatography separation is essential to in-depth proteomic profiling of complex biological samples. Herein, we established an ion-pair reversed-phase×reversed-phase two-dimensional liquid chromatography (IPRP×RP 2DLC) strategy for comprehensive proteomic analysis. Both RPLC separation dimensions were performed at low pH, with trifluoroacetic acid(TFA) and formic acid(FA) as mobile phase addictive, respectively. As the good separation resolution offered by ion-pairing effect of TFA, the fractionation efficiency was greatly improved with 74.0% peptides identified in just one fraction. Comparing with conventional high pH RP fractionation, the overall separation rate of IPRP was about 1.6 times that of high-pH RP, which increased the number of identified peptides by 21%. Further, 2169 proteins and 8540 peptides were confidently identified from crude serum sample by our IPRP×RP 2DLC strategy, exhibiting great potential in clinical proteomics in the future.  相似文献   

13.
李鹏章  王粤博 《化学进展》2012,(9):1785-1793
磷酸化作用是最重要的蛋白质翻译后修饰方式之一,它是蛋白质组学的一个重要分支,在细胞识别、细胞信息传递、基因表达和新陈代谢等方面发挥着重要作用。采用适当方法对磷酸化肽进行分析有助于我们更好地了解生理病理机制。但是直接进行质谱分析时磷酸化肽的信号强度会受到无机盐以及大量非磷酸化肽的抑制,选择性差。为解决这一难题,在质谱分析前要对磷酸化肽进行选择性富集。本文回顾了几种常用的磷酸化肽富集方法,介绍了每种方法的发展状况和常用材料,其中包括固定金属离子亲和色谱法、金属氧化物富集法、强阴阳离子交换色谱法和MALDI靶板富集法。最后总结了各种富集方法的优缺点,对有效的磷酸化肽富集策略进行了前景展望。  相似文献   

14.
The chromatographic behavior of a kind of nucleoside peptides, polyoxins, was investigated in this study. Molecular simulation technique was used to elucidate the temperature‐dependent peak sharpening of polyoxins. There was a relatively small energy barrier between the global minimum conformer and the local minimum conformer of polyoxin A and the high temperature helped to quickly cross the energy barrier and accelerate the conformational transformation for getting the global minimum, so that stationary phase could not identify these two conformations and presented a sharp peak. Two kinds of mixed‐mode columns, strong cation exchange or strong anion exchange ligands bonded with C18 (C18SCX and C18SAX) were used to improve separation selectivity of four polyoxins (A, K, F, H). The electrostatic attraction was necessary to increase the retention to ensure that the alkyl chain can give better play to its hydrophobic effect. Therefore, four polyoxins were well separated on C18SCX at pH 2 and they were also well separated on C18SAX at pH 7. In the small‐scale purification of polyoxins, the sample loading of the C18SCX was five times than that of the C18SAX and the purity of the collected four polyoxins was all over 90%.  相似文献   

15.
为了在短时间内获得相对含量高的磷酸化肽段,以标准磷酸化蛋白质为模型对强阳离子交换色谱(SCX)分离磷酸化肽段体系的缓冲溶液和梯度设置进行了研究,并用酵母酶切肽段混合物考察了该路线在较复杂的样品中的应用。实验结果表明优化后的体系能够在30 min内分离出磷酸肽段,而且非磷酸化肽段的干扰很少,这样便相对提高了磷酸化肽段在质谱仪中的响应强度,重要的是该体系可以对复杂样品进行很好的分离。这说明SCX用于规模化磷酸化肽段富集的策略是可行的。本研究为磷酸化蛋白质组学规模化分析提供了实用技术。  相似文献   

16.
Wu F  Sun D  Wang N  Gong Y  Li L 《Analytica chimica acta》2011,698(1-2):36-43
Three surfactant-assisted shotgun methods using acid labile surfactants, sodium-3-[(2-methyl-2-undecyl-1,3-dioxolan-4-yl)-methoxyl]-1-propanesulfonate (RapiGest) and 3-[3-(1,1-bisalkyloxyethyl)pyridin-1-yl]propane-1-sulfonate (PPS), and sodium dodecyl sulfate (SDS) were investigated for their applicability to membrane proteome analysis. It is shown that RapiGest is a preferred reagent for handling membrane proteomes of Escherichia coli and MCF7 cells for liquid chromatography tandem mass spectrometry (LC MS/MS) analysis of tryptic digests. The RapiGest method allowed identification of more peptides and proteins than the SDS and PPS methods and there was no apparent bias for the type of peptides and proteins identified by the RapiGest and SDS methods, while a slightly higher proportion of hydrophilic peptides and proteins were identified by the PPS method. The performance of the SDS and PPS methods is similar in terms of the numbers of peptides and proteins identified. Since the SDS method required the removal of SDS using a technique such as strong-cation exchange (SCX), we further investigated the effect of SCX on sample loss through analyzing the digest of an enriched E. coli membrane fraction as well as a standard protein, bovine serum albumin (BSA). The results showed that extensive sample loss (as much as 62%) was encountered during the SCX cleaning step. We then applied the RapiGest method in combination with two-dimensional LC MS/MS to characterize the E. coli membrane proteome. In total, 1626 unique proteins (5799 unique peptides) were identified with a peptide false discovery rate of 2.4%. About 60% of the identified proteins with known cellular locations were found to be membrane proteins. Among them, about 75% were integral membrane proteins. This work represents one of the most comprehensive profiles of E. coli membrane proteome generated by a proteomic technique.  相似文献   

17.
In this study, a porous mixed-mode n-alkyl methacrylate-based monolith has been used in the separation of therapeutic peptides. While the sulfonic acid (SCX) moiety derived from 2-acrylamido-2-methyl-1-propanesulfonic acid supports the generation of a stable electroosmotic flow (EOF) at both acidic and basic pH values, the butyl ligands provide the nonpolar sites for chromatographic resolution. The performance of the monolith was evaluated regarding the influence of pH on chromatographic resolution of peptides. The suitability of the butylmethacrylate/SCX monolith for the analysis of therapeutic peptides containing basic centres, for example arginine, at moderately high pH 9.5 and the stability to repeat injections of a mixture of peptides was demonstrated. Separations with efficiencies as high as 5.0 x 10(5) plates/m were obtained and the migration behaviour of the peptides at both low (2.8) and high (9.5) pH values could be rationalised based on their charge, molecular mass/shape and relative hydrophobicities.  相似文献   

18.
SDS-free polyacrylamide gel electrophoresis is an effective alternative approach to peptide fractionation. Here we describe a discontinuous buffer system at acid pH that improves the separation of acidic peptides from tryptic digestion. MOPS and chloride act as trailing and leading ions, respectively, in this system, while histidine operates as counterion and buffers all solutions. In these electrophoretic conditions, peptides with pI below 5.5 migrate with low overall electrophoretic mobilities but high differences from one another, which allows for their efficient resolution. In silico analysis of several proteomes shows that the acid pH system allows a peptide simplification of 2.5-fold with respect to the total peptide mixture, and still a proteome coverage of about 95% is achievable. A straightforward method with a protocol including proteomic studies was achieved for SDS-PAGE of proteins, enzyme treatment and further peptide fractionation by SDS-free acid PAGE.  相似文献   

19.
An overview on the utilization of monoliths in proteomics technology will be given. Both silica- and polymer-based monoliths have broad use for microseparation of tryptic peptides in reversed-phase (RP) mode before identification by mass spectrometry (MS) or by MS/MS. For two-dimensional (2D) LC separation of peptides before MS or MS/MS analysis, a combination of ion-exchange, usually cation-exchange (CEX) chromatography with RP chromatography on monolithic supports can be employed. Immobilized metal ion affinity chromatography monoliths with immobilized Fe3+-ions are used for the isolation of phosphopeptides. Monoliths with immobilized affinity ligands are usually applied to the rapid separation of proteins and peptides. Miniaturized reactors with immobilized proteolytic enzymes are utilized for rapid on- or offline digestion of isolated proteins or protein mixtures prior to identification by LC-MS/MS. Monoliths also have broad potential for application in sample preparation, prior to further proteomic analyses. Monolithic supports with large pore sizes can be exploited for the isolation of nanoparticles, such as cells, organelles, viruses and protein aggregates. The potential for further adoption of monolithic supports in protein separation and enrichment of low abundance proteins prior to proteolytic digestion and final LC-MS/MS protein identification will be discussed.  相似文献   

20.
This work describes the use of mixed-mode stationary phases which exhibit both strong ion-exchange (either cation-exchange, SCX, or anion-exchange, SAX) and reversed-phase chromatographic characteristics in capillary electrochromatographic separations of pyrimidine derivatives. Different packing materials, namely C6, SCX/C6 and SAX/C6, were compared and the influence of the composition of the carrier electrolyte (concentration of acetonitrile and pH) on the retention behavior of the selected solutes was investigated. A separation of all eight pyrimidine derivatives could be obtained on a 6.5 cm column packed with the SAX/C6 stationary phase in less than 3 min, with good peak shapes and efficiencies in the range 39,000 to 81,000 plates per meter.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号