首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
A simple and economical capillary electrophoresis method has been developed for the analysis of four model basic proteins by employing a polymeric ionic liquid (PIL), poly(1-vinyl-3-butylimidazolium) bromide, as the dynamic coating additive. When a small amount of PIL was present in the background electrolyte, a cationic coating on the inner surface of fused-silica capillary was established. These PIL modified capillaries not only generated a stable reversed electroosmotic flow, but also effectively eliminated the wall adsorption of proteins. Several important parameters such as the PIL concentration in the background electrolyte, pH values and concentrations of the background electrolyte were optimized to improve the separation of basic proteins. Consequently, under the optimum conditions, a satisfied separation of basic proteins with peak efficiencies ranging from 247,000 to 540,000 (plates m−1) had been accomplished within 11 min. The run-to-run RSDs (n = 3) of the migration times for the four basic proteins were all less than 0.37%.  相似文献   

2.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

3.
Capillary electrophoresis using 1-butyl-3-methylimidazolium tetrafluoroborate as background electrolyte for the separation and determination of 11 amino acids was studied. Several parameters, such as ionic liquid concentration, pH of background electrolyte and applied voltage, were optimized. Amino acids were derived with Sanger’s reagent (2,4-dinitrofluorobenzene) and the detection was performed by an ultraviolet absorption detector at 360 nm. Under selected conditions, 11 amino acids were completely separated within 16 min. The RSD values of integrated areas and migration times are <3.03 and <1.64%, respectively. The electroosmotic flow can be influenced by imidazolium cation, and the association between the imidazolium cation and the derived amino acids plays an important role in the separation mechanism. This method not only provides an approach for the separation and determination of amino acids, but is also an extension of the ionic liquid application to capillary electrophoresis.  相似文献   

4.
Ultrasound-assisted ionic liquid dispersive liquid-phase micro-extraction was developed for the determination of four aromatic amines such as 2,4-dichloroaniline, 1-naphthylamine, 6-chloroanline and N,N-dimethylaniline. High-performance liquid chromatography coupled with UV detector was used for the determination of aromatic amines. In the novel procedure, 1-hexyl-3-methylimidazolium hexafluorophosphate [C6MIM] [PF6] was dispersed into the aqueous sample solution as fine droplets by ultrasonication, and which promoted the analytes more easily migrate into the ionic liquid phase. Variable affecting such as the volume of [C6MIM] [PF6], sample pH, ultrasonication time, extraction time, centrifuging time have been investigated in detail. The proposed method has been found to have excellent detection sensitivity with limits of detection (LOD, S/N = 3) in the range of 0.17–0.49 μg L−1 and precisions in the range of 2.0–6.1% (RSDs, n = 6). This method has been also successfully applied to analyze the real water samples and good spiked recoveries over the range of 92.2–119.3% were obtained.  相似文献   

5.
A rapid and simple method for the determination of two phthalates and five polycyclic musks in water samples using dispersive liquid-liquid microextraction (DLLME) mated to chemometrics and coupled to GC-MS was developed. Volume of extraction (CCl4) and disperser solvent (MeOH), pH, ionic strength, extraction time, centrifugation time as well as centrifugation speed were optimized in a 27-4 Plackett-Burman design. The obtained significant factors were optimized by using a central composite design (CCD) and the quadratic model between the dependent and the independent variables was built. The optimum experimental conditions of the proposed method were: 250 μL carbon tetrachloride, 0.62 mL methanol, 7.5 min centrifugation time, natural pH containing 0% (w/v) NaCl, while keeping centrifugation speed fixed at 4000 rpm.The calculated calibration curves gave high-level linearity for all target analytes with correlation coefficients ranging between 0.9970 and 0.9992. The repeatability and reproducibility of the proposed method, expressed as relative standard deviation, varied between 2.6% to 9.7% and 5.7% to 12.2%, respectively. The obtained LOD values were in the range of 8-63 ng L−1.  相似文献   

6.
A capillary zone electrophoresis method using only 1-alkyl-3-methylimidazolium-based ionic liquids as background electrolyte for the simultaneous determination of five anthraquinone derivatives including aloe-emodin, emodin, chrysophanol, physcion and rhein in Rhubarb species was described. Ion association constants, Kass, between anthraquinone anions and imidazolium cations were determined by analyzing the electrophoretic mobility change of anthraquinone anions using a non-linear least-squares method and factors contributing to ion associability were systematically clarified. For method optimization, several parameters such as ionic liquids concentration, background electrolyte pH and applied voltage, on the separation were evaluated and the optimum conditions were obtained as follows: 90 mM 1-butyl-3-methylimidazolium tetrafluoroborate (pH 11.0) with an applied voltage of 20 kV. Under these conditions, the method has been successfully applied to the determination of anthraquinones in extracts of two kinds of Rhubarb plants (R. palmatum and R. hotaoense) within 12 min. The method proposed herein was shown to be much simpler than the previously reported methods.  相似文献   

7.
The beneficial effects of several ionic liquids (ILs) as mobile phase additives in high-performance liquid chromatography with electrochemical detection for the determination of six heterocyclic aromatic amines (HAs) have been evaluated for first-time. The studied ionic liquids were 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF4), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF4) and 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF4). Several chromatographic parameters have been evaluated in the presence or absence of ILs, or using ammonium acetate as the most common mobile phase additive, with three different C18 stationary phases. The effect of the acetonitrile content was also addressed. In general, best resolution, lower peak-widths (up to 72.1% lower) and lower retention factors are obtained when using ILs rather than ammonium acetate as mobile phase additives. The main improvement was obtained in the baseline noise, being 360% less noisy for BMIm-BF4, 310% for HMIm-BF4, and 227% for MOIm-BF4, when compared to ammonium acetate at +1000 mV. Different chromatographic methods using the best conditions for each IL were also evaluated and compared. Finally, the best chromatographic conditions using 1 mM of BMIm-BF4 as mobile phase additive, the Nova-Pak® C18 column, 19% (v/v) of acetonitrile content in the mobile phase, and +1000 mV in the ECD, have been applied for the chromatographic analysis of six HAs contained in meat-based infant foods. The whole extraction method of meat-based infant foods using focused microwave-assisted extraction and solid-phase extraction has also been optimized. Extraction efficiencies up to 89% and detection limits ranged between 9.30 and 0.165 ng g−1 have been obtained under optimized conditions.  相似文献   

8.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

9.
An in-vial liquid–liquid microextraction method was developed for the selective extraction of the phenolic acids (caffeic, gallic, cinnamic, ferulic, chlorogenic, syringic, vanillic, benzoic, p-hydroxybenzoic, 2,4-dihydroxybenzoic, o-coumaric, m-coumaric and p-coumaric) in vegetable oil samples. The optimised extraction conditions for 20 g sample were: volume of diluent (n-hexane), 2 mL; extractant, methanol: 5 mM sodium hydroxide (60:40; v/v); volume of extractant, 300 μL (twice); vortex, 1 min; centrifugation, 5 min. Recoveries for the studied phenolic acids were 80.1–119.5%. The simultaneous determination of the phenolic acid extracts was investigated by capillary electrophoresis (CE). Separations were carried out on a bare fused-silica capillary (50 μm i.d. × 40 cm length) involving 25 mM sodium tetraborate (pH 9.15) and 5% methanol as CE background electrolyte in the normal polarity mode, voltage of 30 kV, temperature of 25 °C, injection time of 4 s (50 mbar) and electropherograms were recorded at 200 nm. The phenolic acids were successfully separated in less than 10 min. The validated in-vial LLME-CE method was applied to the determination of phenolic acids in vegetable oil samples (extra virgin olive oil, virgin olive oil, pure olive oil, walnut oil and grapeseed oil). The developed method shows significant advantages over the current methods as lengthy evaporation step is not required.  相似文献   

10.
In this work, a new stir cake sorptive extraction (SCSE) using polymeric ionic liquid monolith as sorbent was prepared. The sorbent was obtained by in situ copolymerization of an ionic liquid, 1-allyl-3-methylimidazolium bis[(trifluoro methyl)sulfonyl]imide (AMII) and divinylbenzene (DB) in the presence of N,N-dimethylformamide. The influence of the content of ionic liquid and the porogen in the polymerization mixture on extraction performance was studied thoroughly. The physicochemical properties of the polymeric ionic liquid were characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The usefulness of SCSE–AMIIDB was demonstrated by the enrichment of trace benzimidazole anthelmintics. Several parameters affecting the extraction efficiency were investigated, and under the optimized conditions, a simple and effective method for the determination of trace benzimidazoles residues in water, milk and honey samples was established by coupling SCSE–AMIIDB with high performance liquid chromatography/diode array detection (SCSE–AMIIDB–HPLC/DAD). Results indicated that the limits of detection (S/N = 3) for target compounds were 0.020–0.072 μg L−1, 0.035–0.10 μg L−1 and 0.026–0.076 μg L−1 in water, milk and honey samples, respectively. In addition, an acceptable reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations (RSD) of less than 9% and 11%, respectively. Finally, the established AMII–SCSE–HPLC/DAD method was successfully applied for the determination of benzimidazoles residues in milk, honey and environmental water samples. Recoveries obtained for the determination of benzimidazole anthelmintics in spiking samples ranged from 70.2% to 117.6%, with RSD below 12% in all cases.  相似文献   

11.
A simple dispersive liquid-liquid microextraction methodology based on the application of 1-hexylpyridinium hexafluorophosphate [HPy][PF6] ionic liquid (IL) as an extractant solvent was proposed for the preconcentration of trace levels of zinc as a prior step to determination by flame atomic absorption spectrometry (FAAS). Zinc was complexed with 8-hydroxyquinoline (oxine) and extracted into ionic liquid. Some effective factors that influence the microextraction efficiency such as pH, oxine concentration, amount of IL, ionic strength, temperature and centrifugation time were investigated and optimized. In the optimum experimental conditions, the limit of detection (3 s) and the enhancement factor were 0.22 μg L−1 and 71, respectively. The relative standard deviation (RSD) for six replicate determinations of 13 μg L−1 Zn was 1.92%. In order to validate the developed method, a certified reference material (NIST SRM 1549) was analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the trace determination of zinc in water and milk samples.  相似文献   

12.
In this study, a simple, rapid, and highly efficient liquid-phase microextraction method based on solidification of floating organic droplet was coupled with high performance liquid chromatography-photo diode array detection (HPLC-PDA) for determination of ketoconazole, clotrimazole, and miconazole as antifungal drugs. Central composite design (CCD) was used for optimization of several factors affecting the extraction efficiency. The optimized conditions were established to be 550 rpm for stirring rate, 35 min for extraction time, 57 °C for extraction temperature, 8.5 for solution pH, 10 μl for organic solvent volume, and 7% (w/v) of NaCl for ionic strength. Limit of detections (LODs) of the extraction method ranged from 0.01 to 0.1 μg L−1 and the linear dynamic ranges (LDRs) ranged from 0.1 to 300 μg L−1 for the three antifungal drugs. Relative standard deviations (RSDs) of the proposed method were 5-11%. Preconcentration factors in the range of 306-1350 were obtained at extraction time of 35 min. Finally, performance of the proposed method was evaluated for the extraction and determination of the drugs’ levels in microgram per liter in samples and satisfactory results were obtained.  相似文献   

13.
In this study, headspace single-drop microextraction (HS-SDME) coupled with gas chromatography-flame ionization detection (GC-FID), was employed to determine short-chain fatty acids (SCFAs) in ruthenium tetroxide (RuO4) oxidation products of asphaltenes. Several significant parameters, such as drop solvent type, drop volume, sample solution ionic strength, agitation speed, extraction time, and ratio of headspace volume to sample volume were optimized. Under optimum extraction conditions (i.e., a 3-μL drop of 1-butanol, 20 min exposure to the headspace of a 6 mL aqueous sample placed in a 10 mL vial, stirring at 1000 rpm at room temperature, and 30% (w/v) NaCl content), the reproducibility and accuracy of the method have been tested and found to be satisfactory. The analysis of a real asphaltene sample using this method proved that HS-SDME can be a promising tool for the determination of volatile SCFAs in complex matrices.  相似文献   

14.
In this work, a method for simultaneous determination of amfepramone, fenproporex, sibutramine and fluoxetine was developed by capillary zone electrophoresis with capacitively coupled contactless conductivity detection (C4D) using a homemade capillary electrophoretic system. The optimized conditions for the separation of the pharmaceuticals by CZE were as follows: 50 mmol L− 1 phosphate buffer (pH 5.0) in 50/50 (v/v) mixture of water/acetonitrile as the working electrolyte, 15 kV separation voltage, 25 °C separation temperature, hydrodynamic injection by gravity using 20 cm injection height and 60 s injection time. The detection by C4D was carried out by using a homemade detector, which employs a sinusoidal wave generator operating at 600 kHz frequency and 2 Vpp wave amplitude. The optimized and validated CZE-C4D method was applied for the determination of the studied pharmaceuticals as adulterants in phytotherapeutic formulations commercialized in Brazil for slimming purposes.  相似文献   

15.
A field-amplified sample injection (FASI) technique was elaborated for fast and sensitive determination of selected central nervous system drugs in human urine samples. Factors affecting the sensitivity enhancement, such as background electrolyte (BGE) and the analytical matrix composition were optimized and discussed. Pseudo-isotachophoresis (p-ITP) mechanism contribution in preconcentration mechanism was discussed. All separations were performed in uncoated fused silica capillaries 50 μm × 57 cm at 22 kV. The optimized analytical matrix was composed of 0.25 mM HCOOH in 90% (v/v) methanol, while BGE contained 45 mM TRIS/HCl (pH 2.20). The head-column injection was performed in 0.25 mM HCOOH water solution (3 s, 3.45 kPa). Sample was introduced into the capillary by electrokinetic injection (70 s, 5 kV) followed by short BGE plug (3 s, 3.45 kPa). Seven psychiatric drugs (olanzapine, prochlorperazine dimaleate, trifluoperazine dihydrochloride, perphenazine, promazine hydrochloride, clomipramine hydrochloride, and chlorprothixene hydrochloride) were separated in about 6 min. The elaborated method was additionally supported with dispersive liquid–liquid microextraction (DLLME) technique which in summary with FASI provided about 8000–13,000-fold sensitivity enhancement in comparison to the capillary zone electrophoresis (CZE) method with standard hydrodynamic injection (5 s, 3.45 kPa).  相似文献   

16.
Lihong Liu  Zhide Hu 《Talanta》2007,71(1):155-159
A simple, rapid, and accurate method for the separation and determination of alpinetin and cardamonin in Alpinia katsumadai Hayata was developed by combination of flow injection (FI)-micellar electrokinetic chromatography (MEKC) for the first time. The analysis was carried out using an unmodified fused-silica capillary (50 μm i.d.; total length 13.6 cm; effective length 10.3 cm) and direct ultraviolet (UV) detection at 214 nm. The sample throughput was 11-24 samples per hour using the background electrolyte (BGE) containing 4 mM sodium borate-8 mM NaH2PO4 (pH 8.1)-8 mM sodium dodecyl sulfate (SDS)-19% (v/v) ethanol. The repeatabilities (n = 4) reached relative standard deviation values (R.S.D.) of 3.0% and 2.5% for the peak areas and 2.5% and 3.1% for peak heights of alpinetin and cardamonin, respectively. Regression equations revealed linear relationships (r2: 0.9993-0.9994) between the peak area of each analyte and the concentration. Recoveries were in the range 90-92% and 99-105% for alpinetin and cardamonin, respectively.  相似文献   

17.
A new frontal electroelution approach that can be used for the preconcentration of amino acids in in-line solid-phase extraction-capillary electrophoresis (SPE-CE) has been developed. A single capillary was employed featuring a short monolithic SPE column created inside the capillary via photo-initiated, free-radical polymerisation of 3-sulfopropyl methacrylate and butyl methacrylate monomers. A weak electrolyte of dilute H2SO4, pH 2.9, was found to promote adsorption of the amino acids onto the SPE column. Elution of the amino acids was achieved using a dual solvation/ion-exchange transient boundary mobilised via EOF by using a strong electrolyte containing 62.5 mM ethylenediamine, pH 2.9 with H2SO4 and 40% (v/v) acetonitrile. Using these two electrolytes, tryptophan was adsorbed onto the SPE column in weak electrolyte and eluted via a frontal electroelution mechanism in the strong electrolyte. Injections up to 20 min, corresponding to over 14 column volumes (or 1400% of the capillary volume) of sample provided quantitative extraction of tryptophan from the weak electrolyte and were eluted without any loss in efficiency. This represents a practical increase of approximately 300-fold when compared to a typical hydrodynamic injection occupying 5% of the capillary volume.  相似文献   

18.
The enantiomeric purity determination of a synthetic intermediate of new 3,4-dihydro-2,2-dimethyl-2H-1-benzopyrans, i.e. 4-amino-2,2-dimethyl-6-ethoxycarbonylamino-3,4-dihydro-2H-1-benzopyran, was successfully carried out using an anionic cyclodextrin (CD) derivative combined with a chiral ionic liquid (IL). In order to obtain high resolution and efficiency values, the addition of a chiral IL, i.e. ethylcholine bis(trifluoromethylsulfonyl)imide (EtChol NTf2), to the background electrolyte containing heptakis(2,3-di-O-methyl-6-O-sulfo)-β-CD (HDMS-β-CD) was found to be essential. A simultaneous increase in separation selectivity and enantioresolution seems to indicate a synergistic effect of HDMS-β-CD and EtChol NTf2. The best enantioseparation of the key intermediate was achieved using a methanolic solution of 0.75 M formic acid, 10 mM ammonium formate, 1.5 mM HDMS-β-CD and 5 mM EtChol NTf2. Levamisole was selected as internal standard. The optimized conditions allowed the determination of 0.1% of each enantiomer in the presence of its stereoisomer using the method of standard additions. The NACE method was then fully validated with respect to selectivity, response function, trueness, precision, accuracy, linearity and limits of detection and quantification.  相似文献   

19.
Cao J  Dun WL 《Talanta》2011,84(1):155-159
In this report, a novel means for the separation and sweeping of flavonoids (quercetin, rutin, calycosin, ononin and calycosin-7-O-β-d-glucoside) by microemulsion electrokinetic chromatography using mixed anionic and cationic surfactants as modified pseudostationary phase was presented. The optimized background electrolyte consisted of 0.5% (w/v) ethyl acetate, 2.0% (w/v) SDS, 9 mM DTAC, 4.0% (w/v) 1-butanol and 10 mM sodium borate or 25 mM phosphoric acid. We systematically investigated the separation and preconcentration conditions, including the concentrations of surfactant, types of sweeping, sample matrix, the effect of high salt or acetonitrile, and sample injection volume. It was found that the use of mixed surfactants significantly enhanced the separation efficiency through the change of the efficient electrophoretic mobility of analytes. Compared with normal sample injection, 185-508-fold sensitivity enhancement in terms of limit of detection was achieved through effective sweeping of large sample volume at 50 mbar pressure (up to 45% capillary length). At last, the proposed method was suitable for the determination of Radix Astragali sample.  相似文献   

20.
Room temperature ionic liquids can be considered as environmentally benign solvents with unique physicochemical properties. Ionic liquids can be used as extractant phases in SDME, being compatible with chromatographic systems. A single-drop microextraction method was developed for separation and preconcentration of mercury species (MeHg+, EtHg+, PhHg+ and Hg2+), which relies on the formation of the corresponding dithizonates and microextraction of these neutral chelates onto a microdrop of an ionic liquid. Afterwards, the separation and determination were carried out by high-performance liquid chromatography with a photodiode array detector. Variables affecting the formation and extraction of mercury dithizonates were optimized. The optimum conditions found were: microextraction time, 20 min; stirring rate, 900 rpm; pH, 11; ionic liquid type, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]); drop volume, 4 μL; and no sodium chloride addition. Limits of detection were between 1.0 and 22.8 μg L−1 for the four species of mercury, while the repeatability of the method, expressed as relative standard deviation, was between 3.7 and 11.6% (n = 8). The method was finally applied to the determination of mercury species in different water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号