首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the present study, an analytical method using capillary electrophoresis with on-line preconcentration technique was developed for rapid determination of melamine in infant formula. Both stacking and sweeping preconcentration techniques had been investigated for the comparison of their effectiveness in melamine analysis. The limit of detection of melamine standard was 0.5 ng/mL for the field amplified sample stacking (FASS) technique and 9.2 ng/mL for the sweeping technique. Although the FASS technique provided better concentration efficacy than the sweeping technique, the matrix effect was more profound with the former. Matrix effect was evaluated by comparing the enhancement factor (EF) of melamine standard and post-extraction spiked infant formula solution. The EF was changed from 429.86 ± 9.81 to the level less than 133.31 with significant peak distortion in the FASS system, and it was remained unchanged in the sweeping system. Sweeping-micellar electrokinetic chromatography (sweeping-MEKC) was demonstrated to be most suitable for real sample analysis. Under optimum sweeping-MEKC conditions, melamine content in infant formulas could be determined within 6 min. The developed solid phase extraction (SPE) procedures coupled with the sweeping-MEKC method was subjected to method validation. Run-to-run repeatability (n = 3) and day-to-day reproducibility (n = 3) of peak area were within 3.6% and 4.8% RSD, respectively. The accuracy was tested by spiking 0.5 and 2 μg/mL of melamine standard in the melamine contaminated milk powder provided by the European Commission, and the recoveries were 93.4 ± 0.5% and 98.7 ± 0.4%, respectively. Results of this study show a great potential for the sweeping-MEKC method as a tool for the fast screening of melamine in infant formulas.  相似文献   

2.
The quantification of the HIV integrase inhibitor raltegravir in blood plasma is described using solid phase extraction (SPE) coupled with an accurate high-performance liquid chromatography assay with ultraviolet (UV) detection. The method was validated over the range of 20-10,000 ng/mL using simple sample preparation and chromatography. The SPE method was optimized to be selective and highly efficient. The buffer’s ionic strength and pH were optimized for retaining RAL and the internal standard on the column, the percentage of methanol was optimized in the cleaning step to remove unwanted plasma contaminants, and the type and amount of acid was optimized for complete elution of the compounds. This method has no interference with other potentially co-administered antiretrovirals or common drugs. Average recoveries for the extraction method were consistently high: 90% for raltegravir and 90% for the internal standard diazepam. This method was found to be accurate and precise. Within day (n = 6) and between day (n = 18) accuracies ranged from 97.5 to 104.4%. Within-day (n = 6) and between-day (n = 18) precision ranged from 1.4 to 3.8%, and from 2.4 to 7.9%, respectively. This is the first published method to use simple UV technology and reliable SPE extraction methodology for the quantification of raltegravir in human plasma. This method can be easily implemented in most bioanalytical laboratories.  相似文献   

3.
The number of cases of invasive fungal infections (IFIs) has risen significantly in recent years; therefore, this study developed a sensitive and effective sweeping-micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of the three most frequently used triazole antifungal drugs for the treatment of IFIs, which included voriconazole, itraconazole, and posaconazole. Due to the diverse lipophilicity of the tested drugs, the analytical conditions that resulted in good resolution between itraconazole and posaconazole caused the peak for voriconazole to split. The splitting phenomenon was resolved by incorporating a high-salt stacking mechanism into the sweeping-MEKC method. The optimum background electrolyte was composed of 25 mM phosphoric acid solution (pH 2.2), 100 mM sodium dodecyl sulfate, 13 % acetonitrile, and 13 % tetrahydrofuran. The best peak shape of voriconazole was obtained when the conductivity ratio between the sample matrix and background electrolyte was 2.3. Compared to the conventional MEKC mode, the enhancement factor of the sweeping-MEKC method was 66 for itraconazole, 55 for posaconazole, and 43 for voriconazole. The sweeping-MEKC method was validated in terms of precision, accuracy, linearity, specificity, selectivity, and sensitivity. The linearity ranges of the method covered the commonly used therapeutic ranges of the three drugs. The developed sweeping-MEKC method was successfully applied to the analysis of clinical samples, thus demonstrating its applicability for clinical use.  相似文献   

4.
A simple and reliable co-electroosmotic capillary electrophoresis system for the fast determination of aromatic acids has been developed by employing poly (1-vinyl-3-butylimidazolium bromide) as the background electrolyte modifier. The polymeric ionic liquid was synthesized by the conventional radical polymerization. The reversed electroosmotic flow was obtained by adding a small amount of the polymeric ionic liquid (0.0006%, w/v) to the electrolyte. To further improve the resolution of aromatic acids, conditions including the concentration of polymeric ionic liquid and pH of background electrolytes were optimized. All eight aromatic acids were baseline resolved in one measurement in a short time (less than 3.5 min) under optimized conditions, 100 mM NaH2PO4 buffer containing 0.006% (w/v) polymeric ionic liquid, pH 6.0. Separation efficiencies were in the range from 355,000 to 943,000 (plates/m). Satisfactory reproducibility on the basis of the migration time of analytes was achieved. RSDs (n = 3) were less than 0.33% except the p-aminobenzoic acid (0.9%). The applicability of the present method has been demonstrated for the determination of water-soluble aromatic acids in a common drug for external use.  相似文献   

5.
In the present study, we have developed a method based on pressurized liquid extraction (PLE) and liquid chromatography with fluorescence detection (LC-FLD) for the determination of residues of fluoroquinolones (FQs) in infant food products. PLE extraction has been optimized by the application of experimental design methodologies. Initially, a fractional factorial design (FFD) was used to screen the significance of four extraction parameters: solvent composition, temperature, pressure and number of cycles. The most significant factors, identified by ANOVA analysis, were the solvent composition, temperature and pressure, which were further optimized with the aid of a face centred design (FCD) and the desirability function. The optimized operating PLE conditions were as follows: ACN/o-phosphoric acid 50 mM pH 3.0 (80:20, v/v), 80 °C, 2000 psi and three extraction cycles of 5 min. Under these conditions, recoveries of the target FQs varied between 69% and 107% with RSDs below 9%. The whole method was validated according to the Commission Decision 2002/657/EC guidelines. The proposed method has been successfully applied to the analysis of different infant food products bought in local supermarkets and pharmacies. The results showed the presence of residues of enrofloxacin in a non-compliant baby food sample corresponding to a chicken-based formulation, which were also confirmed and quantified by LC–MS/MS analysis.  相似文献   

6.
An ion chromatography method with non-suppressed conductivity detection was developed for the simultaneous determination of dimethylamine (DMA), trimethylamine (TMA) and trimethylamine-n-oxide (TMAO) in aquatic products. They were separated by means of cation-exchange chromatography using a 3.0 mmol/L methanesulfonic acid solution as eluent and an IonPac CS17 column (250 mm × 4 mm i.d.) as the separation column. Detection limits of dimethylamine, trimethylamine and trimethylamine-n-oxide were 0.06, 0.08 and 0.10 mg/L, respectively. The relative standard deviations (RSDs) of peak area were less than 3.53%. The recoveries were between 93.7% and 104.1%. Unlike traditional methods, this validated method is inexpensive and stable.  相似文献   

7.
Electro membrane extraction (EME) as a new microextraction method was applied for extraction of sodium diclofenac (SDF) as an acidic compound from wastewater, urine, bovine milk and plasma samples. Under applied potential of 20 V during the extraction, SDF migrated from a 2.1 mL of sample solution (1 mM NaOH), through a supported liquid membrane (SLM), into a 30 μL acceptor solution (10 mM NaOH), exist inside the lumen of the hollow fiber. The negative electrode was placed in the donor solution, and the positive electrode was placed in the acceptor solution. 1-octanol was immobilized in the pores of a porous hollow fiber of polypropylene as SLM. Then the extract was analyzed by means of high-performance liquid chromatography (HPLC) with UV-detection for quantification of SDF. Best results were obtained using a phosphate running electrolyte (10 mM, pH 2.5). The ranges of quantitation for different samples were 8–500 ng mL−1. Intra- and inter-day RSDs were less than 14.5%. Under the optimized conditions, the preconcentration factors were between 31 and 66 and also the limit of detections (LODs) ranged from 2.7 ng mL−1 to 5 ng mL−1 in different samples. This procedure was applied to determine SDF in wastewater, bovine milk, urine and plasma samples (spiked and real samples). Extraction recoveries for different samples were between 44–95% after 5 min of extraction.  相似文献   

8.
Helena Hansson 《Talanta》2009,79(3):633-638
The utility of a dynamic hollow-fibre liquid phase microextraction method (optimized using a four-variable experimental design and response surface modelling) for extracting dinitrophenolic compounds from human plasma samples was evaluated. The investigated variables were donor phase salt concentration (10-400 mM), donor phase pH (2-6), acceptor phase pH (7-12), and donor/acceptor phase flow rates (30/7.5 to 70/17.5 μL min−1). Four dinitrophenol pesticides were used as model substances at concentrations of 0.1 μg mL−1 in spiked human plasma samples. Extraction efficiencies ranging from 42 to 77% with RSDs below 9 were achieved with the optimized method. The flow rate and acceptor pH were shown to strongly affect the extraction efficiency for all compounds, while the donor phase pH and salt concentration had minor effects. With a well-defined acceptor phase pH and flow rate the system exhibited high robustness. The limits of quantification for the investigated compounds, using the presented extraction method followed by liquid chromatography/electrospray ionization mass spectrometry in selected ion monitoring mode, ranged from 0.05 to 0.1 μg mL−1 plasma.  相似文献   

9.
A simple and economical capillary electrophoresis method has been developed for the analysis of four model basic proteins by employing a polymeric ionic liquid (PIL), poly(1-vinyl-3-butylimidazolium) bromide, as the dynamic coating additive. When a small amount of PIL was present in the background electrolyte, a cationic coating on the inner surface of fused-silica capillary was established. These PIL modified capillaries not only generated a stable reversed electroosmotic flow, but also effectively eliminated the wall adsorption of proteins. Several important parameters such as the PIL concentration in the background electrolyte, pH values and concentrations of the background electrolyte were optimized to improve the separation of basic proteins. Consequently, under the optimum conditions, a satisfied separation of basic proteins with peak efficiencies ranging from 247,000 to 540,000 (plates m−1) had been accomplished within 11 min. The run-to-run RSDs (n = 3) of the migration times for the four basic proteins were all less than 0.37%.  相似文献   

10.
A quantitative method of capillary electrophoresis with sample stacking induced by moving reaction boundary (MRB) was developed for sensitive determination of oxymatrine (OMT) and matrine (MT) in rat plasma. The experimental conditions were optimized firstly. Below are the optimized experimental conditions: 20 mM sodium formate solution (HCOONa, adjusted to pH 10.70 by ammonia) as sample solution, 3 min 14 mbar sample injection, 40 mM formic buffer (HCOOH-HCOONa, pH 2.60) as stacking buffer, 7 min 14 mbar injection of stacking buffer, 100 mM HCOOH-HCOONa (pH 4.80) as separation buffer, 73 cm capillary (effective length 64 cm), 21 kV voltage, 210 nm wavelength. Under the optimized conditions, higher than 60-fold sensitivity improvement of the stacking was simply achieved as compared with capillary zone electrophoresis, and the detectable limits obtained for OMT and MT were 0.26 and 0.19 μg mL−1, respectively. Then, numerous demonstrations were carefully performed for the methodological validations of OMT and MT in rate plasma, including high specificity of method, good linearity (r = 0.9993 for OMT, r = 0.9991 for MT), fair wide linear concentration range (1.30-65.00 μg mL−1 for OMT, 0.84-42.00 μg mL−1 for MT), low limit of detection (1.03 μg mL−1 for OMT, 0.38 μg mL−1 for MT), less than 5% intra- and inter-day variance value, and higher than 96% recovery of OMT and MT in plasma. The developed method could be used for the trace analyses of OMT and MT in plasma and was finally used for the investigation on pharmacokinetic study of OMT in rat plasma.  相似文献   

11.
The first version of nano-injection device for capillary gas chromatography (cGC) based on inkjet microchip was developed. The nano-injector could accurately control the injection volume in nano-liter, even pico-liter range. Its configuration and mechanism were discussed in detail. Adopting photolithography and plasma etching technology, we firstly fabricated the inkjet microchip and stuck to a piezoelectric device to eject droplets. Then, a special feedback tube was added to make it function as a nano-injector for cGC, which was an important design to compensate pressure difference between the evaporation chamber of cGC and the sample extrusion chamber of inkjet microchip. The injected volume can be precisely controlled by the number of injected droplets. Excellent precision (RSDs were below 10.0%, n = 5) was observed for the injection of ethanol at elevated pressure. Minimum injection volume was about 1.25 nL at present. Additionally, good repeatability of the calibration curves for the hydrocarbons ethanolic solution (the RSDs of all components were below 5.30%, n = 5) confirmed its feasibility in quantitative analysis regardless of concentration. These results suggested that it can be an accurate nano-injector for cGC.  相似文献   

12.
I.-Lin Tsai  Churn-Shiouh Gau 《Talanta》2009,77(3):1208-1216
In-hospital deaths caused by the infection of methicillin-resistant Staphylococcus aureus (MRSA) are on the increase worldwide. Teicoplanin is a potent glycopeptide antibiotic against MRSA. A rapid and cost-saving micellar electrokinetic chromatography (MEKC) method combined with solid phase extraction (SPE) was developed and then validated to quantify teicoplanin in patient serum in this work. The method includes the following steps: (1) pretreatment of the serum samples with 10 M urea to denature proteins, (2) application of SPE by using an OASIS HLB cartridge to clean up and concentrate the serum samples, and (3) use of MEKC for sample analysis. Under the optimized conditions, the SPE recovery of teicoplanin is higher than 90%. The six major components of teicoplanin could be baseline-separated from one another and endogenous materials in 12 min with a background electrolyte composed of 20 mM sodium tetraborate buffer pH 8.8, 40 mM sodium dodecyl sulfate, and 11% (v/v) ACN. The relative standard deviation (R.S.D.) of the peak area ratios for method repeatability (n = 6) and intermediate precision (inter-day, n = 3) were found to be lower than 4.18% and 5.30%, respectively. The calibration curves were linear between the chromatographic response and total teicoplanin concentration over the range of 5 μg/mL to 55 μg/mL. Limit of detection (LOD) for each of the six components was found to be lower than 0.06 μg/mL. Pearson’s correlation revealed that a good correlation (r = 0.98) was obtained between the SPE-MEKC method and the fluorescence polarization immunoassay (FPIA) method. The developed method can be used to quantitatively determine serum teicoplanin concentration in patients for dose monitoring and clinical research.  相似文献   

13.
A phenylboronic acid-silica hybrid monolithic column for capillary liquid chromatography (cLC) was prepared through one-pot process by using 4-vinylphenylboronic acid (VPBA) and alkoxysilanes simultaneously. The effects of the molar ratio of tetramethyloxysilane/γ-methacryloxypropyltrimethoxysilane (TMOS/γ-MAPS), amount of VPBA, and the volume of diethylene glycol (DEG) on the morphologies, permeabilities and pore properties of the prepared VPBA-silica hybrid monolithic columns were studied in detail. A relatively uniform monolithic structure with high porosity was obtained with optimized ingredients. A series of cis-diol-containing compounds, alkylbenzenes, amides, and anilines were utilized to evaluate the retention behaviors of the VPBA-silica hybrid monolithic column. The result demonstrated that the prepared VPBA-silica hybrid monolithic column exhibited multiple interactions including hydrophobicity, hydrophilicity, as well as cation exchange apart from the expected affinity interaction. The run-to-run, column-to-column and batch-to-batch reproducibility of the VPBA-silica hybrid monolith were satisfactory with the relative standard deviations (RSDs) less than 1.63% (n = 5), 2.02% (n = 3) and 2.90% (n = 5), respectively, indicating the effectiveness and practicability of the proposed method. In addition, the VPBA-silica hybrid monolithic column was further applied to the separation of proteins and tryptic digest of bovine serum albumin (BSA), respectively. The successful applications suggested the potential of the VPBA-silica hybrid monolith in proteome analysis.  相似文献   

14.
In the present work, the separations of calixarene derivatives have been investigated using both high-performance liquid chromatography (HPLC) and nonaqueous capillary electrophoresis (NACE) techniques. HPLC-1 method with LC-318 (pore size = 300 Å) column and MeCN mobile phase was optimized for the separation of calixarenes. At the flow-rate of 1 ml/min p-nitrocalix[6]arene, calix[4]arene and calix[6]arene could be well baseline and symmetrically separated within 5 min. For the separation of p-tert-butylcalix[n]arenes (n = 4, 6, 8), HPLC-2 and NACE methods have been optimized. The optimal conditions in HPLC-2 method included NH2 column and MeCN mobile phase, and p-tert-butylcalix[n]arenes (n = 4, 6, 8) were baseline separated within 10 min at 0.8 min/min. The optimal conditions for NACE method employed MeCN-H2O (8:2, v/v) as the nonaqueous medium and 120 mM Tris/HCl (pH 9.0) as the buffer, and p-tert-butylcalix[n]arenes (n = 4, 6, 8) were successfully baseline resolved within 16 min. With the detection at 280 nm, the calibration lines were linear in the ranges of 1-200 μg/ml for calixarene derivatives by HPLC-1 and HPLC-2 methods, and of 2.5-200 μg/ml for p-tert-butylcalix[n]arenes (n = 4, 6, 8) by NACE method, respectively. The detection limits (S/N = 3) and recoveries ranged from 0.5 to 1.4 μg/ml and from 98.1 to 102.4% by both HPLC-1 and HPLC-2 methods, and from 1.3 to 2.0 μg/ml and from 97.9 to 105.1% by NACE method, respectively. The intra-day reproducibility of the methods was determined with satisfactory results. The proposed HPLC and NACE methods were accurate and reproducible, and could be utilized to separate and determine calixarene derivatives.  相似文献   

15.
A simple and sensitive sweeping micellar electrokinetic chromatography method coupled with UV laser-induced native fluorescence detection has been developed for quantitative analysis of biogenic amines in biofluids. The background electrolyte comprised 30 mmol L−1 phosphoric acid and 20 mmol L−1 sodium dodecyl sulfate. The concentration limits of detection of analytes using sweeping-micellar electrokinetic chromatography (sweeping-MEKC) were in the range 7–100 nmol L−1, which were 250–3600-fold improvement for dopamine, DOPA and epinephrine compared with conventional capillary zone electrophoresis. An improvement of approximately 20-fold was observed for all analytes compared with typical micellar electrokinetic chromatography conditions. Baseline separation was achieved for the all analytes within 12 min and migration-time and peak-area repeatability were better than RSD 0.35% and 5.68%, respectively. The developed method was applied to measure the biogenic amines in biofluids extracted from wheat phloem sap, human plasma and human urine.  相似文献   

16.
In this study, a porous polypropylene frit was coated with polydimethylsiloxane (PDMS) as extraction medium, based on the home-made PDMS-frit, a rapid, simple and sensitive sorptive extraction method was established for analysis of potential biomarkers of lung cancer (hexanal and heptanal) in human serum samples. In the method, derivatization and extraction occurred simultaneously on the PDMS-frit, then the loaded frit was ultrasonically desorbed in acetonitrile. Polymerization, derivatization–extraction and desorption conditions were optimized. Under the optimal conditions, satisfactory results were gained, a wide linear application range was obtained in the range of 0.002–5.0 μmol L−1 (R > 0.997) for two aldehydes, the detection limits (S N−1 = 3) were 0.5 nmol L−1 for hexanal and 0.4 nmol L−1 for heptanal. The relative standard deviations (RSDs, n = 5) of the method were below 7.9% and the recoveries were above 72.7% for the spiked serum. All these results hint that the proposed method is potential for disease markers analysis in complex biological samples.  相似文献   

17.
Based on TiO2-nanoparticles coating fabricated by a one-step anodization method on titanium wire substrate, a novel phenyl functionalized solid-phase microextraction (SPME) fiber coating was prepared by simple and rapid in situ chemical assembling technique between the fiber surface titanol groups and trichlorophenylsilane reaction. The as-fabricated fiber exhibited good extraction capability for some UV filters and was employed to determine the ultraviolet (UV) filters in combination with high performance liquid chromatography–UV detection (HPLC–UV). The main parameters affecting extraction performance were investigated and optimized. Under the optimized conditions, the developed method was applied to detect several UV filters at trace concentration levels with only 8 mL of sample volume. They were determined in the range from 0.005 to 25 μg L−1 with detection limits (S/N = 3) from 0.1 to 50 ng L−1. The relative standard deviations (RSDs) for single fiber repeatability varied from 4.6 to 6.5% (n = 5) and fiber-to-fiber reproducibility (n = 5) ranged from 5.5 to 9.1%. The linear ranges spanned two-four magnitudes with correlation coefficients above 0.9990. Five real water samples including four Yellow River water samples and one rain water sample were determined sensitively with good recoveries ranging from 86.2 to 105.5%. The functionalized fiber coating performed good reproducible manner, high mechanical strength, good stability and long service life. Moreover, this study proposed an efficient sample pretreatment method for the determination of UV filters from environmental water samples.  相似文献   

18.
Microemulsion electrokinetic chromatography (MEEKC) was developed for quantitative analysis of avermectins, such as abamectin, doramectin and ivermectin, in commercial formulations, using the microemulsion buffer containing a 50 mM phosphate buffer at pH 2.5, 1.1% (v/v) n-octane as oil droplets, 180 mM sodium dodecylsulphate as surfactant, 890 mM 1-butanol as co-surfactant and 30% (v/v) ethanol as organic co-solvent. High accuracy and precision of the method were obtained. The contents of avermectins in commercial formulations determined by MEEKC were found to be insignificantly different with those determined by high performance liquid chromatography (HPLC). Therefore, MEEKC can be used an alternative method to HPLC for quantitative determination of avermectins.  相似文献   

19.
An efficient micellar electrokinetic chromatography (MEKC) method has been developed for the analysis of nine anthraquinones and bianthrones in rhubarb. A chemometric approach was used to search for the optimum conditions of separation. Those factors which were found to be significant with a screening design were further optimized with a central composite face-centered (CCF) design. Acetonitrile concentration was found to be the most influential, not only in resolution, but also in analysis time and peak asymmetry. With the optimized conditions: 15 mM sodium tetraborate/15 mM sodium dihydrogenphosphate buffer, 30 mM sodium deoxycholate, pH 8.6, 17 vol.% acetonitrile and 28 kV, nine tested analytes were baseline-separated within 14 min. The method was validated to analyze the rhubarb material. Solid-phase extraction (SPE) was manipulated to remove interfering substances. Five anthraquinones and two glycosidic bianthrones were detected and quantificated. The method should be suitable for determining these major active principles in rhubarb crude drugs.  相似文献   

20.
The coupling of Ru(bpy)32+ based electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) was developed for the simultaneous determination of the two major active ingredients (atropine and scopolamine) in Flos daturae. Parameters related to the separation and detection were discussed and optimized. It was proved that 20 mM phosphate buffer at pH 8.48 could achieve the most favorable resolution, and the high sensitivity of detection was obtained by maintaining the detection potential at 1.2 V. Under the optimized conditions: ECL detection at 1.2 V, 20 mM phosphate buffer at pH 8.48, 5 mM Ru(bpy)32+ and 50 mM phosphate buffer at pH 7.48 in the detection reservoir, detection limits of 5 × 10−8 mol/l for atropine and 1 × 10−6 mol/l for scopolamine were obtained. Relative standard derivations of the ECL intensity and the migration time were 5.16 and 0.71% for atropine and 5.07 and 1.22% for scopolamine, respectively. Developed method was successfully applied to determine the amounts of both alkaloids in Flos daturae. A baseline separation for atropine and scopolamine was achieved within 11 min.  相似文献   