首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A fast separation of alkali and alkaline earth metal cations and ammonium was carried out by capillary electrochromatography on monolithic octadecylsilica columns of 15 cm length and 100 μm inner diameter using water/methanol mixtures containing acetic acid as mobile phase. On-column contactless conductivity detection was used for quantification of these non-UV-absorbing species. The method was also extended successfully to the determination of small amines as well as of amino acids, and the separation selectivity was optimized by varying the composition of the mobile phase. Detection limits of about 1 μM were possible for the inorganic cations as well as for the small amines, while the amino acids could be quantified down to about 10 μM. The separation of 12 amino acids was achieved in the relatively short time of 10 min.  相似文献   

2.
Ahmed S  Atia NN  Mohamed NA 《Talanta》2011,84(3):666-672
A simple, reproducible and efficient dual separation mode high performance liquid chromatographic (HPLC) method was developed for simultaneous determination of antihypertensive drug combinations including; hydrochlorothiazide (HCTZ), valsartan (VAL), amiloride (AML) and captopril (CAP). The newly developed Platinum™ column, which provides a dual-mode separation with its polar and non-polar sites, was used for rapid separation of these co-administered drugs. Good resolution was obtained when Platinum™ column was used compared with C18 column. Additionally, simple isocratic mode with mobile phase containing methanol and 0.02 mole L−1 phosphate buffer adjusted to pH 3.0 (45:55, v/v) was used for separation. The flow rate was 0.5 mL min−1 and effluent was monitored at 270 nm. All the investigated drugs were completely separated within less than 6 min. The linearity range obtained for the developed HPLC method was 0.5-100 μg mL−1 with detection limits of 0.13-1.2 μg mL−1 for all the studied drugs. The method was validated in accordance with the requirements of ICH guidelines and shown to be suitable for intended applications. The method was successfully used for determination of the studied drugs in pure form and pharmaceutical dosage forms without prior need for separation. The method is valuable for quality control laboratories for simultaneous determination of these co-administered antihypertensive drugs in binary, ternary and quaternary mixtures.  相似文献   

3.
Kang J  Yan J  Liu J  Qiu H  Yin XB  Yang X  Wang E 《Talanta》2005,66(4):1018-1024
In this paper a method was described about dynamic coating for resolving rhodamine B (RB) adsorption on a hybrid poly(dimethylsiloxane) (PDMS)/glass chip. The results showed that when the non-ionic surfactant Triton X-100 was higher than 0.5% (v/v) into the phosphate buffer, the adsorption of RB appeared. Besides, some separation conditions for RB were investigated, including concentration of Triton X-100, concentration and pH value of running buffer, separation voltage and detection site. Through comparing electroosmotic flow, plate numbers and other parameters, an acceptable separation condition was obtained. Under optimized conditions, the precisions of RB detection (R.S.D., n = 10) were 2.62% for migration time, 4.78% for peak height respectively. Additionally, RB concentration linearity response was excellent with 0.9996 of correlation coefficient between 1 and 100 μM, and a limit of detection (S/N = 3) was 0.2 μM. Finally, we separated rhodamine B isothiocyanate and lysine deriving from the fluorescent probe, and the result displayed that the dynamic coating method was applicable by CE separations using PDMS/glass chip.  相似文献   

4.
The gas chromatographic–mass spectrometric (GC–MS) separation of all 209 polychlorinated biphenyl (PCB) congeners was studied on an extremely efficient 80 m × 0.1 mm i.d. capillary column coated with a 0.1 μm film of poly(5%-phenyl methyl)siloxane stationary phase. The quality of the separation and the number of resolved and coeluting peaks were compared to predictions according to the statistical overlap theory (SOT) and to literature data on PCB separations obtained by one-dimensional and comprehensive two-dimensional GC (GC × GC) and GC–MS. Mass spectral and chemometric deconvolution procedures were used to resolve overlapping peaks. On the highly efficient column, 195 PCB congeners were resolved in 96 min separation time using spectral and chemometric deconvolution. This number is comparable to the best separations described in GC × GC–MS mode. The novel method was developed for spectral deconvolution of overlapped PCB congeners which was verified determining the most toxic, dioxin-like PCBs both in the model mixture of 209 PCBs as well as in the Aroclor 1242 and Aroclor 1254 formulations.  相似文献   

5.
A new straightforward method based on cloud-point extraction (CPE) was developed to determine osthole in rat plasma by reversed phase high-performance liquid chromatography with ultraviolet detection using a photodiode array detector. The non-ionic surfactant Triton X-114 was chosen as the extract solvent. Variable parameters affecting the CPE efficiency were evaluated and optimized. A Zorbax SB-C18 column was used for elution separation at 25 °C with detection wavelength at 322 nm. Under the optimum conditions, the method was shown to be reproducible and reliable with intra-day precision below 7.62%, inter-day precision below 6.37%, and accuracy within ±5.02% and mean extraction recovery more than 90.4%, which were all calculated using a range of spiked samples at three concentrations of 0.5, 5.0 and 15.0 μg mL−1 for osthole in plasma. The calibration curve for the analyte was linear in the range from 0.1 to 20 μg mL−1 with the correlation coefficients greater than 0.9981. Limit of detection (S/N = 3) was less than 0.03 μg mL−1and limit of quantification (S/N = 10) was less than 0.1 μg mL−1. After strict validation, the method was successfully applied to the pharmacokinetic study of osthole in rats after oral and intravenous administration, respectively.  相似文献   

6.
A new method for sensitive and fast screening of melamine (MEL) in milk products was developed with a low-cost disposable microfluidic device coupled with ultraviolet (UV) detection. This method avoided the need of sample pretreatment prior to the separation process, thus was simple and green. Due to the advantages of the device and fracture sampling technique, milk sample could be directly sampled through the fracture to achieve baseline separation from amino acids, and proteins in the sample did not interfere with the detection. Using 20 mM phosphate running buffer (pH 9.0), a sampling time of 3 s at +180 V and a separation voltage of +1800 V (240 V/cm), this method could detect MEL in milk within 75 s. At the detection wavelength of 202 nm, the linear range for MEL was from 1.0 to 100 μg mL−1 with a detection limit of 0.23 μg mL−1 (S/N = 3). The novel protocol had been successfully used to screen MEL in milk samples with recovery more than 82%. The environmentally friendly methodology for pretreatment-free sensitive screening of MEL provided promising applications in monitoring the quality of different foods.  相似文献   

7.
CE methods have been developed for the analysis of organic and peroxide-based explosives. These methods have been developed for deployment on portable, in-field instrumentation for rapid screening. Both classes of compounds are neutral and were separated using micellar electrokinetic chromatography (MEKC). The effects of sample composition, separation temperature, and background electrolyte composition were investigated. The optimised separation conditions (25 mM sodium tetraborate, 75 mM sodium dodecyl sulfate at 25 °C, detection at 200 nm) were applied to the separation of 25 organic explosives in 17 min, with very high efficiency (typically greater than 300,000 plates m−1) and high sensitivity (LOD typically less than 0.5 mg L−1; around 1–1.5 μM). A MEKC method was also developed for peroxide-based explosives (10 mM sodium tetraborate, 100 mM sodium dodecyl sulfate at 25 °C, detection at 200 nm). UV detection provided LODs between 5.5 and 45.0 mg L−1 (or 31.2–304 μM), which is comparable to results achieved using liquid chromatography. Importantly, no sample pre-treatment or post-column reaction was necessary and the peroxide-based explosives were not decomposed to hydrogen peroxide. Both MEKC methods have been applied to pre-blast analysis and for the detection of post-blast residues recovered from controlled, small scale detonations of organic and peroxide-based explosive devices.  相似文献   

8.
A simple, accurate, precise, rapid and sensitive stability-indicating capillary electrophoresis (CE) method was optimized and validated for the simultaneous determination of norfloxacin and its inactive decarboxylated degradant in pharmaceuticals. The univariant method was used to optimize electrophoretic factors including injection time, separation voltage and column temperature. Electrolyte concentration and pH were optimized using the factorial design and response surface methods. The optimum conditions obtained were: 10 mmol l− 1 phosphate at pH 2.5, hydrodynamic injection time of 8 s at pressure 0.5 p.s.i., separation voltage 25 kV and column temperature 25 °C. The separation was carried out into a fused-silica capillary column (31.2 cm length × 50 μm i.d.) with detection at 301 and 285 nm for the intact drug and the degradant, respectively using a diode array detector. For both analytes, the method enjoys wide dynamic range (1-50 μg ml− 1) with good detectability (limits of detection 0.11 μg ml− 1). In addition, acceptable accuracy (recovery > 95%); and good repeatability and intermediate precision (RSD < 3.5%) were obtained.  相似文献   

9.
Mikus P  Valásková I  Havránek E 《Talanta》2005,65(4):1031-1037
A capillary electrophoresis method has been developed for the separation and determination of terbinafine (TER) in various pharmaceutically relevant matrices. Capillary zone electrophoresis (CZE) separation and UV absorbance photometric detection were carried out in a 160 mm capillary tube with a 300 μm i.d., hydrodynamically (membrane) closed. The influences of pH, carrier cation and counterion on migration parameters of TER were studied and the following conditions were selected: a 20 mmol l−1 glycine running buffer adjusted to pH 2.7 with acetic acid, 0.2% (w/v) methylhydroxyethylcellulose (m-HEC) as an electro-osmotic flow (EOF) suppressor, a 250 μA driving current, and 20 °C. The optimized separation conditions were convenient for the determination of TER in commercial tablets and spray and in dialyzates. Here, the dialysis was used to investigate in vitro permeation of TER through the skin from the gel. The samples of dialyzates were examined with and without simple extraction procedure and the results were compared. A permeation profile of the drug present in the gel of given composition was obtained analyzing pretreated samples. The proposed electrophoretic method was successfully validated. It was suitable for the simple, sensitive, rapid and highly reproducible assay of TER. CZE analysis was completed within 5.5 min. The detection limit of TER was 1.73 μmol l−1 at a 224 nm detection wavelength. The intra- and inter-laboratory precisions over the concentration range 6.0-60.0 μmol l−1 were between 0.32-0.69% and 1.04-1.44% including R.S.D. of migration times and peak areas, respectively. The mean absolute recoveries of drugs from samples were found to be 98.34 (tablets) and 99.47% (spray). It is suggested that there are potentialities to determine TER present in unpretreated complex samples, as CZE in a hydrodynamically closed separation system may be easily on-line combinable with purification and preconcentration CE modes (e.g., isotachophoresis, ITP).  相似文献   

10.
Zhang J  Hu Z  Chen X 《Talanta》2005,65(4):986-990
A new capillary electrophoresis (CE) method with laser-induced fluorescence (LIF) detection was developed for the rapid separation and sensitive detection of glutathione (GSH) and glutathione disulfide (GSSH) after derivatization by 4-chloro-7-nitrobenzo-2-oxa-1,3-diazol (NBD-Cl). The derivatization and separation conditions were investigated in detail and the optimums were obtained. Under the optimum experiment conditions, linear relationships between the peak height and concentrations of the analytes in normal and second-derivative electrophoregrams were obtained (0.22-45.00 μM). The detection limits for glutathione and glutathione disulfide in normal and second-derivative electrophoregrams were 0.046 and 0.012 μM and 0.046 and 0.014 μM, respectively. The method was applied to the analysis of glutathione and glutathione disulfide in human plasma and tobacco leaves with satisfactory results.  相似文献   

11.
Nanocrystalline graphite-like pyrolytic carbon film (PCF) electrode fabricated by a non-catalytic chemical vapor deposition (CVD) process was used for the simultaneous electrochemical sensing of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The electrode was studied with respect to changes in electrocatalytic activity caused by a simple and fast electrochemical pretreatment. The anodized electrode exhibited excellent performance compared to many chemically modified electrodes in terms of detection limit, linear dynamic range, and sensitivity. Differential pulse voltammetry (DPV) was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Under optimum conditions, the detection limits were 2.9 μM for AA, 0.04 μM for DA, and 0.03 μM for UA with sensitivities of 0.078, 5.345, and 6.192 A M−1, respectively. The peak separation was 219 mV between AA and DA and 150 mV between DA and UA. No electrode fouling was observed and good reproducibility was obtained in all the experiments. The sensor was successfully applied for the assay of DA in an injectable drug and UA in human urine by using standard addition method.  相似文献   

12.
A method based on capillary electrophoresis with electrochemical detection has been developed for the separation and determination of mannitol, sucrose, glucose, and fructose in Ligustrum lucidum Ait. for the first time. Effects of several important factors such as the concentration of NaOH, separation voltage, injection time, and detection potential were investigated to acquire the optimum conditions. The detection electrode was a 300 μm diameter copper disc electrode at a working potential of +0.65 V (versus saturated calomel electrode (SCE)). The four analytes can be well separated within 13 min in a 40 cm length fused-silica capillary at a separation voltage of 12 kV in a 75 mM NaOH aqueous solution. The relation between peak current and analyte concentration was linear over about three orders of magnitude with detection limits (S/N = 3) ranging from 1 to 2 μM for all analytes. The proposed method has been successfully applied to monitor the mannitol and sugar contents in the plant samples at different growth stages with satisfactory assay results.  相似文献   

13.
In this work, a method based on capillary electrophoresis with amperometric detection and far infrared-assisted extraction has been developed for the determination of rutin, gentisic acid, and quercetin in the leaves of Lycium barbarum Linn. The effects of detection potential, irradiation time, and the voltage applied on the infrared generator were investigated to acquire the optimum analysis conditions. The detection electrode was a 300-μm-diameter carbon disc electrode at a detection potential of +0.90 V. The three analytes could be well separated within 12 min in a 40 cm length fused-silica capillary at a separation voltage of 12 kV in a 50 mM borate buffer (pH 9.2). The relation between peak current and analyte concentration was linear over about 3 orders of magnitude with the detection limits (S/N = 3) of 0.31, 0.48, and 0.78 μM for rutin, gentisic acid, and quercetin, respectively. The proposed method has been applied to determine the three bioactive constituents in real plant samples.  相似文献   

14.
Ye F  Xie Z  Wu X  Lin X 《Talanta》2006,69(1):97-102
A simple and rapid pressurized isocratic capillary electrochromatography (pCEC) method has been developed to separate six pyrethroid pesticides. The effects of pH of buffer, organic solvent content, buffer concentrations and applied voltage on the separation of six pyrethroids were investigated. Under the optimized conditions, the pCEC method developed allows baseline separation of a complex mixture of six pyrethroids in <20 min. The method is applied to the analysis of these pesticide residues in Chinese cabbage. The limits of quantification (LOQ) ranged from 0.5 to 0.8 μg/ml (corresponding to 0.05 and 0.08 mg/kg in the vegetable sample), with relative standard deviations (R.S.D.) <5.0%. Mean values of recoveries for six pyrethroids ranged from 89.6 to 96.3%, respectively.  相似文献   

15.
Jihai Zhou 《Talanta》2009,79(2):189-1249
A CPE-HPLC (UV) method has been developed for the determination of Prometryne. In this method, non-ionic surfactant Triton X-114 was first used to extract and pre-concentrate Prometryne from water and soil samples. The separation and determination of Prometryne were then carried out in an HPLC-UV system with isocratic elution using a detector set at 254 nm wavelength. The parameters and variables that affected the extraction were also investigated and the optimal conditions were found to be 0.5% of Triton X-114 (w/v), 3% of NaCl (w/v) and heat-assisted at 50 °C for 30 min. Using these conditions, the recovery rates of Prometryne ranged from 92.84% to 99.23% in water and 85.48% to 93.67% in soil, respectively, with all the relative standard deviations less than 3.05%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.5 μg L−1 and 11.0 μg L−1 in water and 4.0 μg kg−1 and 13.0 μg kg−1 in soil, respectively. Thus, we developed a method that has proven to be an efficient, green, rapid and inexpensive approach for extraction and determination of Prometryne from soil samples.  相似文献   

16.
A new separation method based on a novel reversed-phase sequential injection chromatography (SIC) technique was used for simultaneous determination of ambroxol hydrochloride and doxycycline in pharmaceutical preparations in this contribution.The coupling of short monolith with SIA system results in an implementation of separation step to until no-separation low-pressure method.A Chromolith® Flash RP-18e, 25-4.6 mm column (Merck, Germany) and a FIAlab® 3000 system (USA) with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-water (20:90, v/v), pH 2.5 adjusted with 98% phosphoric acid, flow rate 0.48 ml min−1, UV detection was at 213 nm.The validation parameters have shown good results: linearity of determination for both compounds including internal standard (ethylparaben) >0.999; repeatability of determination (R.S.D.) in the range 0.5-5.4% at three different concentration levels, detection limits in the range 0.5-2.0 μg ml−1, and recovery from the pharmaceutical preparation in the range 99.3-99.9%. The chromatographic resolution between peak compounds was >5.0 and analysis time was <9 min under the optimal conditions. The method was found to be applicable for routine analysis of the active compounds ambroxol hydrochloride and doxycycline in various pharmaceutical preparations.  相似文献   

17.
N. Shokoufi 《Talanta》2007,73(4):662-667
A new combination method, employing thermal lens spectrometry (TLS) after cloud point extraction (CPE), has been developed for the preconcentration and determination of rhodium. TLS and CPE methods have good matching conditions for the combination because TLS is a suitable method for the analysis of low volume samples obtained after CPE.Rhodium was complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a complexing agent in an aqueous medium and concentrated by octylphenoxypolyethoxyethanol (Triton X-114) as a surfactant. After the phase separation at 50 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into a quartz micro cell and the analyte was determined by laser induced-thermal lens spectrometry (LI-TLS). The single laser TLS was used as a sensitive method for the determination of Rhodium-PAN complex in 20 μL of the sample. Under optimum conditions, the analytical curve was linear for the concentration range of 0.5-50 ng mL−1 and the detection limit was 0.06 ng mL−1. The enhancement factor of 450 was achieved for 10 mL samples containing the analyte and relative standard deviations were lower than 5%. The developed method was successfully applied to the extraction and determination of rhodium in water samples.  相似文献   

18.
Gra?yna Chwatko 《Talanta》2009,79(2):229-234
Thiosulfate is a sulfate analogue with a thiosulfur substituent and is found in human samples. Its concentration in urine is increased in some diseases and after exposure to hydrogen sulfide gas. We have developed a sensitive, simple and cheap method for thiosulfate determination in urine. The method is based on precolumn derivatization with 2-chloro-1-methylquinolinium tetrafluoroborate followed by reversed-phase liquid chromatography separation and ultraviolet detection of 1-methyl-2-thioquinolone at 375 nm. The calibration curve for thiosulfate was linear in the tested range 0.5-50 μmol L−1 with correlation coefficient better than 0.999. The analytical recovery and relative standard deviation values for precision within the calibration range were from 90.1% to 104.2% and from 2.39% to 5.59%, respectively. The lower limit of detection and quantitation were 0.3 and 0.5 μmol L−1, respectively. The mean (range) concentration of thiosulfate normalized against creatinine for apparently healthy seven women and six men was 2.21 (1.45-2.77) and 2.51 (1.36-4.89) mmol mol−1 creatinine, respectively. We monitored thiosulfate in urine samples from one volunteer for 24 h. The urinary excretion of thiosulfate was 21.4 μmol per 24 h. This method can be used for routine clinical monitoring thiosulfate in urine. Cysteine and cysteinylglycine can be measured concurrently, if needed.  相似文献   

19.
A novel solid-phase microextraction (SPME) fiber coating was prepared with siloxane-modified polyurethane acrylic resin by photo-cured technology. The ratio of two monomers was investigated to obtain good microphase separation structure and better extraction performance. The self-made fiber was then applied to organophosphorus pesticides (OPPs) analysis and several factors, such as extraction/desorption time, extraction temperature, salinity, and pH, were studied. The optimized conditions were: 15 min extraction at 25 °C, 5% Na2SO4 content, pH 7.0 and 4 min desorption in GC inlet. The self-made fiber coating exhibited better extraction efficiency for OPPs, compared with three commercial fiber coatings. Under the optimized conditions, the detection limits of 11 OPPs were from 0.03 μg L−1 to 0.5 μg L−1. Good recoveries and repeatabilities were obtained when the method was used to determine OPPs in ecological textile.  相似文献   

20.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号